Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Optoelectronic Control Of Phased-Array Antenna

Radiation patterns switched within microseconds. According to concept, digital beam-steering information destined for number of phased antenna elements transmitted in serial multiplex along optical fiber to optoelectronic integrated circuit (OEIC), demultiplexing information into parallel electronic channels to phase shifters associated with various elements. Because of small distances between elements of such arrays, compactness of optical fibers makes them attractive for distribution of beam-steering (phase-shifting) control signals. Also offers advantages of light weight, low attenuation, mechanical flexibility, large bandwidth, and immunity to both crosstalk and electromagnetic interference.

Bhasin, K. B.↗

Simulations and observations of heating of auroral ion beams

Two-dimensional three-velocity electrostatic particle simulations were used to determine the nonlinear evolution of the distributions of auroral ion beams and thereby to determine quantitatively signatures in the ion distributions produced by the ion-ion instability for a variety of plasma conditions in the auroral zone. The signatures determined from these simulations were compared with observations from DE 1, making it possible to characterize semiquantitatively the heating of the ionospheric ions, and to investigate the causes of variability seen in the observations of Reiff et al. (1988). A comparison of the simulation with observations showed features consistent with heating via the ion-ion instability including perpendicular heating in the supersonic regime and parallel heating in the subsonic regime, and a change in the heating between these regimes as the ratio of the H(+) beam speed to the local sound speed decreases.

Winglee, R. M.↗

Three-Dimensional Simulations of Electron Beams Focused by Periodic Permanent Magnets

A fully three-dimensional (3D) model of an electron beam focused by a periodic permanent magnet (PPM) stack has been developed. First, the simulation code MAFIA was used to model a PPM stack using the magnetostatic solver. The exact geometry of the magnetic focusing structure was modeled; thus, no approximations were made regarding the off-axis fields. The fields from the static solver were loaded into the 3D particle-in-cell (PIC) solver of MAFIA where fully 3D behavior of the beam was simulated in the magnetic focusing field. The PIC solver computes the time-integration of electromagnetic fields simultaneously with the time integration of the equations of motion of charged particles that move under the influence of those fields. Fields caused by those moving charges are also taken into account; thus, effects like space charge and magnetic forces between particles are fully simulated. The electron beam is simulated by a number of macro-particles. These macro-particles represent a given charge Q amounting to that of several million electrons in order to conserve computational time and memory. Particle motion is unrestricted, so particle trajectories can cross paths and move in three dimensions under the influence of 3D electric and magnetic fields. Correspondingly, there is no limit on the initial current density distribution of the electron beam, nor its density distribution at any time during the simulation. Simulation results including beam current density, percent ripple and percent transmission will be presented, and the effects current, magnetic focusing strength and thermal velocities have on beam behavior will be demonstrated using 3D movies showing the evolution of beam characteristics in time and space. Unlike typical beam optics models, this 3D model allows simulation of asymmetric designs such as non- circularly symmetric electrostatic or magnetic focusing as well as the inclusion of input/output couplers.

Kory, Carol L.↗

Directionality effects in the transfer of X-rays from a magnetized atmosphere: Beam pulse shape

A formalism is presented for radiation transfer in two normal polarization modes in finite and semiinfinite plane parallel uniform atmospheres with a magnetic field perpendicular to the surface and arbitrary propagation angles. This method is based on the coupled integral equations of transfer, including emission, absorption, and scattering. Calculations are performed for atmosphere parameters typical of X-ray pulsars. The directionality of the escaping radiation is investigated for several cases, varying the input distributions. Theoretical pencil beam profiles and X-ray pulse shapes are obtained assuming the radiation is emitted from the polar caps of spinning neutron stars. Implications for realistic models of accreting magnetized X-ray sources are briefly discussed.

Meszaros, P.↗

Excitation of long electrostatic solitary waves in ion beam neutralization process

Unusually long electrostatic solitary waves (ESWs) are discovered in a particle-in-cell simulation study of the process of ion beam neutralization by electron emission from a filament. These ESWs are long because the density perturbation responses to the potential wells created by the ESWs are very small. Notably, the density perturbation is small because the trapped (positive) and untrapped (negative) electron density perturbations nearly compensate each other because of a non-Maxwellian electron velocity distribution in the beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Faraday cup for measuring the longitudinal distribution of particle charge density in non-relativistic beams

A Fast Faraday cup includes a group of electrodes including a ground electrode having a through hole and a collector electrode configured with a blind hole that functions a collector hole. The electrodes are configured to allow a beam (e.g., a non-relativistic beam) to fall onto the ground electrode so that the through hole cuts a beamlet that flies into the collector hole and facilitates measurement of the longitudinal distribution of particle charge density in the beam. The diameters, depths, spacing and alignment of the collector hole and the through hole are controllable to enable the Fast Faraday day cup to operate with a fast response time (e.g., fine time resolution) and capture secondary particles.

Sun, Ding↗

Fast faraday cup for measuring the longitudinal distribution of particle charge density in non-relativistic beams

A Fast Faraday Cup includes a group of electrodes including a grounded electrode having a through hole and a collector electrode configured with a blind hole that functions a collector hole. The electrodes are configured to allow a beam (e.g., a non-relativistic beam) to fall onto the grounded electrode so that the through hole cuts a beamlet that flies into the collector hole and facilitates measurement of the longitudinal distribution of particle charge density in the beam. The diameters, depths, spacing and alignment of the collector hole and the through hole are controllable to enable the Fast Faraday day cup to operate with a fast response time (e.g., fine time resolution) and capture secondary particles.

Sun, Ding↗

Nonclassicality of vortex Airy beams in the Wigner representation

The Wigner distribution function (WDF) of a vortex Airy beam is calculated analytically. The WDF provides intuitive pictures of the intriguing features of vorticity in phase space. The nonclassical property of the vortex Airy beam and the Airy beam is analyzed through the negative parts of the WDF. The study shows that destructive interference of certain classical waves can mimic nonclassical lights such as those due to quantum effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

4D in-beam positron emission tomography for verification of motion-compensated ion beam therapy

Purpose: Clinically safe and effective treatment of intrafractionally moving targets with scanned ion beams requires dedicated delivery techniques such as beam tracking. Apart from treatment delivery, also appropriate methods for validation of the actual tumor irradiation are highly desirable. In this contribution the feasibility of four-dimensionally (space and time) resolved, motion-compensated in-beam positron emission tomography (4DibPET) was addressed in experimental studies with scanned carbon ion beams. Methods: A polymethyl methracrylate block sinusoidally moving left-right in beam's eye view was used as target. Radiological depth changes were introduced by placing a stationary ramp-shaped absorber proximal of the moving target. Treatment delivery was compensated for motion by beam tracking. Time-resolved, motion-correlated in-beam PET data acquisition was performed during beam delivery with tracking the moving target and prolonged after beam delivery first with the activated target still in motion and, finally, with the target at rest. Motion-compensated 4DibPET imaging was implemented and the results were compared to a stationary reference irradiation of the same treatment field. Data were used to determine feasibility of 4DibPET but also to evaluate offline in comparison to in-beam PET acquisition. Results: 4D in-beam as well as offline PET imaging was found to be feasible and offers the possibility to verify the correct functioning of beam tracking. Motion compensation of the imaged {beta}{sup +}-activity distribution allows recovery of the volumetric extension of the delivered field for direct comparison with the reference stationary condition. Observed differences in terms of lateral field extension and penumbra in the direction of motion were typically less than 1 mm for both imaging strategies in comparison to the corresponding reference distributions. However, in-beam imaging retained a better spatial correlation of the measured activity with the delivered dose. Conclusions: 4DibPET is a feasible and promising method to validate treatment delivery of scanned ion beams to moving targets. Further investigations will focus on more complex geometries and treatment planning studies with clinical data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Beam generation and planar imaging at energies below 2.40 MeV with carbon and aluminum linear accelerator targets

Purpose: Recent work has demonstrated improvement of image quality with low-Z linear accelerator targets and energies as low as 3.5 MV. In this paper, the authors lower the incident electron beam energy between 1.90 and 2.35 MeV and assess the improvement of megavoltage planar image quality with the use of carbon and aluminum linear accelerator targets. Methods: The bending magnet shunt current was adjusted in a Varian linear accelerator to allow selection of mean electron energy between 1.90 and 2.35 MeV. Linac set points were altered to increase beam current to allow experimental imaging in a practical time frame. Electron energy was determined through comparison of measured and Monte Carlo modeled depth dose curves. Planar image CNR and spatial resolution measurements were performed to quantify the improvement of image quality. Magnitudes of improvement are explained with reference to Monte Carlo generated energy spectra. Results: After modifications to the linac, beam current was increased by a factor greater than four and incident electron energy was determined to have an adjustable range from 1.90 MeV to 2.35 MeV. CNR of cortical bone was increased by a factor ranging from 6.2 to 7.4 and 3.7 to 4.3 for thin and thick phantoms, respectively, compared to a 6 MV therapeutic beam for both aluminum and carbon targets. Spatial resolution was degraded slightly, with a relative change of 3% and 10% at 0.20 lp/mm and 0.40 lp/mm, respectively, when reducing energy from 2.35 to 1.90 MV. The percentage of diagnostic x-rays for the beams examined here, ranges from 46% to 54%.Conclusion: It is possible to produce a large fraction of diagnostic energy x-rays by lowering the beam energy below 2.35 MV. By lowering the beam energy to 1.90 MV or 2.35 MV, CNR improves by factors ranging from 3.7 to 7.4 compared to a 6 MV therapy beam, with only a slight degradation of spatial resolution when lowering the energy from 2.35 MV to 1.90 MV.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-537: Comparison of Intra-Operative Soft X-Rays to Low Energy Electron Beams for Treatment of Superficial Lesions

Purpose: Superficial soft x-ray applicators have recently been designed for use with existing intra-operative radiotherapy systems. These applicators may be used in treating superficial lesions which are conventionally treated with electron beams. The purpose of this abstract is to compare dose distributions of an intra-operative 50kV x-ray unit with low energy electrons for the treatment of superficial lesions. Methods: Dosimetric parameters for 1 and 3-cm diameter Intrabeam superficial x-ray applicators were measured with EBT3 Gafchromic film in a solid water phantom. Depth dose distributions and profiles (d=2, 5, 10 and 15mm) were obtained by prescribing a dose of 400cGy at 5mm depth below the phantom surface. Corresponding dose profiles for 6-MeV electrons were acquired from a Varian Clinac 21EX at 100 SSD. H and D calibration curves were generated for each modality for 0-800cGy. Results: Dose coverage, penumbra, dose uniformity, surface dose, and dose fall-off were examined. Compared to electrons, Intrabeam lateral dose coverage at 5mm depth was 70% larger with a much sharper (1/4) penumbra. Electron isodose levels bulged with depth, whereas Intrabeam isodose levels exhibited a convex cone shape. The Intrabeam dose profiles demonstrated horns in the dose distribution up to a 5mm depth and an exponential dose fall-off. Relative surface dose was higher for the Intrabeam applicators. Treatment times were comparable for both modalities. Conclusions: The very small penumbra of Intrabeam at shallow depths could be useful in treating superficial lesions adjacent to critical structures. The exponential dose fall-off of Intrabeam makes it appealing in the sparing of structures beyond the lesion. However, for lesions past a depth of 5mm, electrons would be desirable as they penetrate farther and provide skin sparing. Intrabeam may be preferable for sites that are difficult to treat with electrons due to mechanical and physical limitations.

07 ISOTOPE AND RADIATION SOURCES↗

Application of MMIC modules in future multiple beam satellite antenna systems

Multiple beam antenna systems for advanced communication satellites operating in the 30/20 GHz frequency bands (30 GHz uplink, 20 GHz downlink) were developed. Up to twenty 0.3 deg HPBW fixed spot beams and six 0.3 deg HPBW scanning spot beams will be required. Array-fed dual reflector antenna systems in which monolithic microwave integrated circuit (MMIC) phase shift and amplifier modules are used with each radiating element of the feed array for beam pointing and power gain were developed. The feasibility of distributed power amplification and beam pointing with MMIC modules in the elements of an array and to develop a data base for future development were demonstrated. The technical discussion centers around the potential advantages of ""monolithic'' antennas for specific applications as compared to systems using high powered TWT's. These include: reduced losses in the beam forming network; advantage of space combining and graceful degradation; dynamic control of beam pointing and illumination contour; and possibilities for cost and weight reduction.

Smetana, J.↗

New Submount Requirement of Conductively Cooled Laser Diodes for Lidar Applications

New submount technology is essential for the development of conductively cooled high power diode laser. The simulation and experimental results indicate that thermal conductivity of submount for high power laser-diode must be at least 600 W/m/k or higher for stable operation. We have simulated several theoretical thermal model based on new submount designs and characterized high power diode lasers to determine temperature effects on the performances of laser diodes. The characterization system measures the beam power, output beam profile, temperature distribution, and spectroscopic property of high power diode laser. The characterization system is composed of four main parts: an infrared imaging camera, a CCD camera, a monochromator, and a power meter. Thermal characteristics of two commercial-grade CW 20-W diode laser bars with open heat-sink type were determined with respect to the line shift of emission spectra and beam power stability. The center wavelength of laser emission has a tendency to shift toward longer wavelength as the driving current and heat sink temperature are increased. The increase of heat sink temperature decreases the output power of the laser bar too. Such results lay the guidelines for the design of new submount for high power laser-diodes.

Mo, S. Y.↗

ToF-SIMS depth profiling of altered glass

Glass and mineral corrosion usually leads to the formation of morphologically and compositionally complex surface layers that can be characterized by various analytical techniques to infer rate control mechanisms. In this study, we investigate the capabilities and limitations of time-of-flight secondary ion mass spectrometry (ToF-SIMS) to better understand chemical processes of glass corrosion. In particular, we focus on the potential impact of the ToF-SIMS ion beam on the distribution of several elements of interest in alteration layers formed on International Simple Glass, a six-oxide reference glass altered in a solution enriched in alkalis and spiked with H 2 18 O. A thin flake of glass partially altered on both sides is analyzed entirely from one side to the other to determine whether atoms weakly bonded to the solid are displaced by the beams. We highlight the beam effect on cations weakly bonded to the silicate network (Li, Na, K, and B, Ca, Cs to a lesser extent) affecting the profile shape of these elements. No impact is observed on 18 O and H, but it is demonstrated that quantification of isotopic ratios is possible only for a limited range of isotopic enrichment.

36 MATERIALS SCIENCE↗

Direct plasma injection scheme with beam extraction in a radio frequency quadrupole linac cavity

Direct plasma injection scheme (DPIS) is a recently developed idea about beam injection into a radio frequency quadrupole (RFQ) linac to obtain high current pulsed heavy ion beam. Since a laser ion source is directly connected to an RFQ linac, a low energy beam transport is not needed. An ion beam is extracted at the edge of the cavity. We shifted the extraction position in the RFQ cavity to improve the beam loss problem due to beam diverging before arriving at the entrance of the RFQ electrode region. In this scheme, ion beam is extracted at the entrance of the RFQ electrode region and the extracted beam is immediately captured by a rf quadrupole electric field. A plasma electrode is inserted in the accelerator resonant cavity. It is required to avoid serious effect on the acceleration characteristics of the RFQ linac. The rf properties were measured using a network analyzer to verify the effect. The shifts of resonant frequency were negligibly small by inserting the electrode. The measurements of the electric field distribution along the beam axis in the RFQ linac showed that the plasma electrode had little effect on it. The result of beam acceleration experiment showed that the beam current was increased by about 20%. It was confirmed that the beam loss was reduced by this scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modification of a metal nanoparticle beam by a hollow electrode discharge

Treatment of nanoparticles (NPs) in complex environments, such as plasmas, is of interest for the fabrication of advanced nanomaterials with desired properties and also from a physical point of view. Here, the authors investigate the mutual interaction between silver NPs and a radio frequency (RF) plasma at different conditions by combining a cylindrical hollow electrode with a gas aggregation source. The investigation of the NP deposits and the morphology of the casted films shows that the applied RF discharge significantly changes the path of the NPs as well as the NP size distribution in the beam. Starting from a neutral NP beam, it is observed that most of the NPs leave the plasma region with negative charge(s), yet the fraction of positively charged NPs grows with power. Furthermore, the plasma characteristics are slightly influenced by the NP flux since the passing NPs collect the plasma charge carriers.

36 MATERIALS SCIENCE↗