Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Reconfiguring band-edge states and charge distribution of organic semiconductor–incorporated 2D perovskites via pressure gating

Two-dimensional (2D) semiconductor heterostructures are key building blocks for many electronic and optoelectronic devices. Reconfiguring the band-edge states and modulating their interplay with charge carriers at the interface in a continuous manner have long been sought yet are challenging. Here, using organic semiconductor–incorporated 2D halide perovskites as the model system, we realize the manipulation of band-edge states and charge distribution via mechanical—rather than chemical or thermal—regulation. Compression induces band-alignment switching and charge redistribution due to the different pressure responses of organic and inorganic building blocks, giving controllable emission properties of 2D perovskites. We propose and demonstrate a “pressure gating” strategy that enables the control of multiple emission states within a single material. We also reveal that band-alignment transition at the organic-inorganic interface is intrinsically not well resolved at room temperature owing to the thermally activated transfer and shuffling of band-edge carriers. This work provides important fundamental insights into the energetics and carrier dynamics of hybrid semiconductor heterostructures.

42 ENGINEERING↗

Direct observation of chirality-induced spin selectivity in electron donor–acceptor molecules

The role of chirality in determining the spin dynamics of photoinduced electron transfer in donor-acceptor molecules remains an open question. Although chirality-induced spin selectivity (CISS) has been demonstrated in molecules bound to substrates, experimental information about whether this process influences spin dynamics in the molecules themselves is lacking. Here we used time-resolved electron paramagnetic resonance spectroscopy to show that CISS strongly influences the spin dynamics of isolated covalent donor–chiral bridge–acceptor (D-Bχ-A) molecules in which selective photoexcitation of D is followed by two rapid, sequential electron-transfer events to yield D •+ -Bχ-A •– . Exploiting this phenomenon affords the possibility of using chiral molecular building blocks to control electron spin states in quantum information applications.

Science & Technology - Other Topics↗

pnnl/ANIMATE

A data-driven performance verification framework, which conducts automated output-based verification of building performance (especially control requirements which be only verified via time-series output)

Lei, Jerry↗

Pacific Northwest National Laboratory Facility Radionuclide Emissions Units and Sampling Systems

Battelle–Pacific Northwest Division operates numerous research and development (R&D) laboratories in Richland, WA, including those associated with Pacific Northwest National Laboratory (PNNL) on the U.S. Department of Energy (DOE)’s Hanford Site and PNNL Site that have the potential for radionuclide air emissions. The National Emission Standard for Hazardous Air Pollutants (NESHAP 40 CFR 61, Subparts H and I) requires an assessment of all emission units that have the potential for radionuclide air emissions. Potential emissions are assessed annually by PNNL staff members. Sampling, monitoring, and other regulatory compliance requirements are designated based upon the potential-to-emit dose criteria found in the regulations. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled systems, a description of the buildings, exhaust units, control technologies, and sample extraction details is provided for each registered emission unit. Additionally, applicable stack sampler configuration drawings, figures, and photographs are provided. Deregistered emission unit details are provided as necessary for up to 5 years post closure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Isotope Production Scale-up at the University of Wisconsin-Madison

This project proposed to improve the infrastructure at the University of Wisconsin Medical Physics cyclotron facility, enabling it to double the production capability to provide Cu-64 and a list of other 3-d and 4-d subshell metals to a wider community of users on the national scale. A series of improvements and target developments were accomplished that have been shared with others through publications and conference presentations. At every step, the economic consequences were weighed: - shielded mini-cells were chosen by competitive bid, yielding the greatest value - separation chemistry was automated with a consistent approach of building remote modules, controlled by LabView, tailored to the above mini-cells, rather than purchasing extravagant “black boxes” from commercial vendors. - other major improvements needed, such as the five-port external beam line for our PETtrace cyclotron, or the Agilent 4200 micro-wave plasma atomic emission spectrometer, were acquired from internal funds that were freed up by this generous DOE award. All together, the symbiosis of these acquisitions has transformed our small-scale distribution efforts to a significant national presence in the PET radio metal community with a broadening network of users. This user base, in 30 labs across the country, promises to bring molecular imaging, with targeted peptides, antibodies and nanostructures labeled with our Cu-64, Zr-89 and other synthons to bear on a variety of diseases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Health Monitoring of Large-Scale Systems

This report details the progress made on the ASCR funded project Performance Health Monitoring for Large Scale Systems. A large-­scale application may not achieve its full performance potential due to degraded performance of even a single subsystem. Detecting performance faults, isolating them, and taking remedial action is critical for the scale of systems on the horizon. PHM aims to develop techniques and tools that can be used to identify and mitigate such performance problems. We accomplish this through two main aspects. The PHM framework encompasses diagnostics, system monitoring, fault isolation, and performance evaluation capabilities that indicates when a performance fault has been detected, either due to an anomaly present in the system itself or due to contention for shared resources between concurrently executing jobs. Software components called the PHM Control system then build upon the capabilities provided by the PHM framework to mitigate degradation caused by performance problems.

97 MATHEMATICS AND COMPUTING↗

Technical Analysis of Installed Micro-Combined Heat and Power Fuel-Cell System

Combined heat and power fuel cell systems (CHP-FCSs) provide consistent electrical power and hot water with greater efficiency and lower emissions than alternative sources. These systems can be used either as baseload, grid-connected, or as off-the-grid power sources. This report presents a technical analysis of 5 kWe CHP-FCSs installed in different locations in the U.S. At some sites as many as five 5 kWe system is used to provide up to 25kWe of power. Systems in this power range are considered “micro”-CHP-FCS. To better assess performance of micro-CHP-FCS and understand their benefits, the U.S. Department of Energy worked with ClearEdge Power to install fifteen 5-kWe PBI high temperature PEM fuel cells (CE5 models) in the commercial markets of California and Oregon. Pacific Northwest National Laboratory evaluated these systems in terms of their economics, operations, and technical performance. These units were monitored from September 2011 until June 2013. During this time, about 190,000 hours of data were collected and more than 17 billion data points were analyzed. Beginning in July 2013, ten of these systems were gradually replaced with ungraded systems (M5 models) containing phosphoric acid fuel cell technology. The new units were monitored until June 2014 until they went offline because ClearEdge was bought by Doosan at the time and the new manufacturer did not continue to support data collection and maintenance of these units. During these two phases, data was collected at once per second and data analysis techniques were applied to understand behavior of these systems. The results of this analysis indicate that systems installed in the second phase of this demonstration performed much better in terms of availability, consistency in generation, and reliability. The average net electrical power output increased from 4.1 to 4.9 kWe, net heat recovery from 4.7 to 5.4 kWth, and system availability improved from 94% to 95%. The average net system electric efficiency, average net heat recovery efficiency, and overall net efficiency of the system increased respectively from 33% to 36%, from 38% to 41%, and from 71% to 76%. The temperature of water sent to sit however reduced by about 16% from 51⁰C to 43 ⁰C. This was a control strategy and the temperature can be controlled depending on building heat demands. More importantly, the number of shutdowns and maintenance events required to keep the systems running at the manufacturer’s rated performance specifications were substantially reduced by about 76% (for 8 to 10 units running over a one-year period). From July 2012 to June 2013, there were eight CE5 units in operation and a total of 134 scheduled and unscheduled shutdowns took place. From July 2013 to June 2014, between two to ten units were in operation and only 32 shutdowns were reported (all unscheduled). In summary, the number of shutdowns reduced from 10 shutdowns per month on average for eight CE5units to an average of 2.7 shutdowns per month for M5 units (between two to ten units).

combined heat and power↗

Quantitative adaptation analytics for assessing dynamic systems of systems: LDRD Final Report

Our society is increasingly reliant on systems and interoperating collections of systems, known as systems of systems (SoS). These SoS are often subject to changing missions (e.g., nation- building, arms-control treaties), threats (e.g., asymmetric warfare, terrorism), natural environments (e.g., climate, weather, natural disasters) and budgets. How well can SoS adapt to these types of dynamic conditions? This report details the results of a three year Laboratory Directed Research and Development (LDRD) project aimed at developing metrics and methodologies for quantifying the adaptability of systems and SoS. Work products include: derivation of a set of adaptability metrics, a method for combining the metrics into a system of systems adaptability index (SoSAI) used to compare adaptability of SoS designs, development of a prototype dynamic SoS (proto-dSoS) simulation environment which provides the ability to investigate the validity of the adaptability metric set, and two test cases that evaluate the usefulness of a subset of the adaptability metrics and SoSAI for distinguishing good from poor adaptability in a SoS. Intellectual property results include three patents pending: A Method For Quantifying Relative System Adaptability, Method for Evaluating System Performance, and A Method for Determining Systems Re-Tasking.

99 GENERAL AND MISCELLANEOUS↗

Impact Noise Monitoring for Gelled Water Mitigation Test Series - North Pad

This report represents the 1st shot (in a series of 8) conducted on September 15, 2022. One 10 lb C4 charge (along with ~200g of Potassium Bromide (KBr)) was detonated inside 9920 North Pad Boom Box. Noise sampling was performed at several points on Site 9920 to characterize the noise mitigation provided by the block structure. This data will help inform safe locations for Members of the Workforce (MOWs) to be located during future testing with similar net explosive weights. During the test, all MOW/site visitors were bunkered inside Building 9926/Mobile Firing Control Point (MFCP) to prevent personnel exposure to any hazards associated with the testing

42 ENGINEERING↗

Investigating Hydrogen Isotope Exchange Reactions on Lithium Aluminate Pellets in TPBAR (FY22 Report)

We developed a novel operando Raman spectroscopy method for investigation of hydrogen (H) isotope exchange reactions in the lithium aluminate (γ-LiAlO 2 ) that allows modeling of tritium behaviors in high temperature and in an irradiated environment. The lithium aluminate pellet is a main component in the Tritium-Producing Burnable Absorber Rod (TPBAR). We used deuterium ( 2 H or D) as a surrogate to simulate tritium ( 3 H or T). We used a surface analysis tools in situ/operando Raman spectroscopy to observe the transformation OH and OD compositional changes. We also used ToF-SIMS to analyze the lithium aluminate pellet control sample to build the base line for future in situ/operando analysis. To conduct operando Raman spectroscopy, we developed a custom reaction cell with a detachable micro heater using microelectromechanical systems (MEMS) and 3D printing techniques. Multiple versions were developed and tested. Using the new reaction cell, we demonstrated operando Raman spectroscopy of water (H 2 O) and deuterated water (D 2 O) with nitrogen (N 2 ) exposure onto the lithium aluminate (LiAlO2) pellet specimen, respectively, using a wet gas injection setup. We also successfully developed a detachable microheater that can heat up to ~250°C for ~90 mins. The Raman spectra did not show clear H 2 O and D 2 O characteristic peaks, which indicates that introducing H 2 O and D 2 O onto the surface of the pellet is challenging due to its dense structure nature. Our efforts suggest that various improvements are needed, such as increasing reaction cell operating gas pressure and thinning pellet sample thickness, to obtain meaningful measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Demonstration of Model-Based Design for Digital Controller Using Formal Methods

This report describes work originally performed in FY19 that assembled a workflow enabling formal verification of high-consequence digital controllers. The approach builds on an engineering analysis strategy using multiple abstraction levels (Model-Based Design) and performs exhaustive formal analysis of appropriate levels – here, state machines and C code – to assure always/never properties of digital logic that cannot be verified by testing alone. The operation of the workflow is illustrated using example models and code, including expected failures of verification when properties are violated.

97 MATHEMATICS AND COMPUTING↗

Demonstration of the BNL Continuous Dual Trap Analyzer to Detect Perfluorocarbon Tracers for the Tag, Track and Location Program

The Tag, Track and Location System (TTL) Program is investigating methods of tracking an asset using perfluorocarbon tracers (PFT). The success of any TTL method requires sound detection/location instrumentation. Tracer Detection Technologies Corp (TDT), through a contract with the Office of Naval Research (ONR), is investigating different detection systems. The detections systems generally fall into two categories; proximity detectors and standoff detectors. Proximity detectors, as the name implies, need to be in close proximity (e.g., meter to 10's of meters) to the PFT source. Standoff detection searches for the PFT from a greater distance away from the source (e.g., 100's of meters to kilometers). Gas Chromatographs (GC) are generally considered a proximity detection systems, but in the case of PFTs should be considered for both proximity and standoff detection with the caveat that in standoff use the GC needs to be somewhere in the PFT plume, i.e., generally downwind of the source. With a properly sized PFT source, the right GC can afford fairly large standoff (distance from the source) distances; 100's of meters to kilometers downwind. Brookhaven National Laboratory (BNL) has such a GC system and offered to demonstrate the CDTA for TTL as a no cost addition to the TDTTTL project, of which BNL was a participant. BNL is a leading authority on the sampling, collection, release and detection of PFTs. In addition, the BNL team has extensive background in atmospheric dispersion, the application of PFTs to such studies and the development of applications utilizing PFTs such as building infiltration measurements, control room integrity determination, leak location and environmental investigations. This experience and expertise is essential in developing any PFT application were dispersion, dilution and overcoming environmental conditions and interferences are integral to success. BNL has developed sophisticated gas chromatography methods and instruments that allow detection of up to seven PFTs at part per quadrillion levels (1015) with sample times as short as 60 seconds. The Continuous Dual-Trap Analyzer (CDTA) was developed for leak hunting applications and can continuously sample the air for PFTs without interruption. Sample time can be as short as 60 seconds. The CDTA has been extensively used in the commercial sector to detect PFTs that have been introduced to leaking buried dielectric fluid-filled cables or leaking subsurface gas lines. The PFTs travel through the cable or pipe until they reach the leak site. PFTs then escape into the surrounding soil and permeate/diffuse to the surface where they can be detected with the CDTA. Typically a cable is tagged with ppm levels of PFTs resulting in ppt to ppq concentrations in the air at the leak site. The CDTA is proven to be rugged, reliable and has a proven track record of successful leak location. The application of the CDTA to PFT detection for TTL is identical to application for leak detection. The CDTA operator has a general idea, with a few miles of roadway, where the leak is located, but no specific knowledge of the location (it can be any where along the road). The CDTA is mounted in a Chevy Astro Van and is dispatched to the field. In the field the van is driven at nominally 15 mph along the road. The CDTA continuously samples the air outside the van (via a 1/4-inch plastic sample tube stuck out a side window) until a positive detection occurs. The van then covers the road section where the detection occurred at a slightly slower pace to pin-point the area where the leak is and to direct soil probe samples. The soil probe samples take soil gas samples every 10 yards or so and the samples are analyzed on the CDTA. The leak can be located to within a few feet in 95% of the cases. To date the CDTA has been successful in every leak hunt performed by BNL. One interesting case was a leak hunt that resulted in repeated negative detections. The confidence in the CDTA forced the utility to recheck its 'plumbing' which lead to the discovery that a valve was turned that shouldn't have been so that gas was being diverted rather than leaking (the pressure drop was due to this diversion of the gas to another line). For TTL application, a tagged item or person is known to be in a general area and can be located by detecting the PFT emanating from the tagging source. The CDTA can be deployed in the area and by sampling in a grid fashion (starting on the downwind side of the area of interest) can easily find even very small sources. The CDTA is a perfect match for this application and the leak hunt use basically a simulation of Track and Locate. No other PFT detection technology has the detection sensitivity, proven track record and ruggedness of the CDTA. For these reasons, BNL offered to demonstrate the CDTA for TTL as a no cost addition to the TTL lidar demonstration project. This report details the demonstration scenario and results.

36 MATERIALS SCIENCE↗

Pacific Northwest National Laboratory Facility Radionuclide Emission Points and Sampling Systems

Battelle—Pacific Northwest Division operates numerous research and development laboratories in Richland, Washington, including those associated with the Pacific Northwest National Laboratory (PNNL) on the Department of Energy’s Hanford Site that have the potential for radionuclide air emissions. The National Emission Standard for Hazardous Air Pollutants (NESHAP 40 CFR 61, Subparts H and I) requires an assessment of all effluent release points that have the potential for radionuclide emissions. Potential emissions are assessed annually. Sampling, monitoring, and other regulatory compliance requirements are designated based upon the potential-to-emit dose criteria found in the regulations. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission point system performance, operation, and design information. A description of the buildings, exhaust points, control technologies, and sample extraction details is provided for each registered or deregistered facility emission point. Additionally, applicable stack sampler configuration drawings, figures, and photographs are provided.

radionuclide air emission↗

Open Automated Demand Response Communications Specification (Version 1.0)

The development of the Open Automated Demand Response Communications Specification, also known as OpenADR or Open Auto-DR, began in 2002 following the California electricity crisis. The work has been carried out by the Demand Response Research Center (DRRC), which is managed by Lawrence Berkeley National Laboratory. This specification describes an open standards-based communications data model designed to facilitate sending and receiving demand response price and reliability signals from a utility or Independent System Operator to electric customers. OpenADR is one element of the Smart Grid information and communications technologies that are being developed to improve optimization between electric supply and demand. The intention of the open automated demand response communications data model is to provide interoperable signals to building and industrial control systems that are preprogrammed to take action based on a demand response signal, enabling a demand response event to be fully automated, with no manual intervention. The OpenADR specification is a flexible infrastructure to facilitate common information exchange between the utility or Independent System Operator and end-use participants. The concept of an open specification is intended to allow anyone to implement the signaling systems, the automation server or the automation clients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inflight optical measurement of antenna surfaces

A technology base was developed for a wide variety of applications oriented sensors to meet requirements for the fabrication, assembly, test, surface figure monitoring, and ultimately surface figure active control of large space antennas. An optical sensor technique is described which establishes an ideal centerline at each beam during fabrication or later during assembly. Deviations from the centerline, either in lateral deformation or in twist, are measured to produce limit warnings or to evoke active control at the building machine.

Neiswander, R. S.↗

Solar-heated swimming school--Wilmington, Delaware

Report describes operation, installation, and performance of solar-energy system which provides alternative to natural gas pool heating. System is comprised of 2,500 square feet of liquid flat-plate collectors connected to 3,600 galloon; gallongalloon storage tank, with microcomputer-based controls. Extension of building incorporates vertical-wall, passive collection system which provides quarter of heated fresh air for office.

Source record↗

Landsat-D data acquisition and processing

The Landsat-D system, in which S-band and X-band data links will provide real-time direct transmission of sensor data, is described. System performance objectives include input data quantity of 200 MSS scenes/day and 100 TM scenes/day by the Domestic Communication Satellite, and processing capability, in a pipeline mode, of 2.6 x 10 to the 11th input bits of sensor data per 16-hour day. Data processing techniques, including automated cloudcover assessment, control point library build system, radiometric calibration, and geometric correction are discussed.

Smith, P. L., Jr.↗