Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Direct Power Control of Back to Back Modular Multilevel Converter with Advanced Grid Support Functions for Grid Forming Application

Possibility of using back-to-back modular multilevel converter system with a direct power control architecture has been investigated in this paper. The rectifier side is controlled to be in grid following mode whereas the inverter side is controlled in grid forming mode. Both the sides’ local controllers use Lyapunov energy function based architecture to accomplish the objective of active and reactive power control as well as maintaining a fixed user defined voltage over the dc bus on the rectifier side. Therefore, the proposed direct power control architecture has embedded dc bus control architecture to maintain fixed user defined value of the capacitors. Similar architecture is implemented on the inverter side to accomplish either voltage control during grid forming or power control during grid following. Advanced grid support functionalities based on IEEE-1547-2018 is implemented and utilized to generate the reference values for either the rectifier or the inverter sides. The overall system is modeled based on MATLAB/Simulink and PLECS domain and various important case studies to verify the efficacy of the overall system has been presented.

direct power control (DPC)↗

Big Data Analytic for Cascading Failure Analysis

With the challenges of increased grid dynamics and more variability of power generation from renewable energy sources, rapidly increasing complexity in the grid model, and abundant data from measurements and simulations, the requirements for computational analysis have also increased dramatically. Power system operators and engineers need to analyze more scenarios, extract meaningful information from a larger set of data, and respond more quickly when faced with these new challenges for large-scale applications, such as contingency analysis. This paper proposes a novel big data analysis approach for power system cascading analysis, prevention, and remediation. The developed techniques will be capable of cascading analysis, better assessment of the system’s vulnerability level, as well as proposing potential remediation. Case studies using IEEE 118-bus system and a 500-bus system, with a comparison against a commercial tool, validate the advantages of the developed big data approach: accurate prediction, and more importantly, faster and effective correction actions.The developed techniques could be further used for other power system applications.

big data, cascading analysis, corrective action, m↗

Distributed Learning of Mode Shapes in Power System Models

We address the problem of distributed estimation of eigenvectors for power system models using online phasor measurements. The power system is considered to be divided into a set of non-overlapping areas, each of which is equipped with a local estimator. Online measurements of bus voltage and current phasors are first used to generate estimates of the generator states in each area using decentralized Kalman filters. Thereafter, these estimates are used for identifying a reduced-order model of the system in a completely distributed way by sharing state information between the estimators over a strongly connected communication graph. The identified model is then utilized to estimate its right eigenvectors over the same distributed graph. Results are validated using a 50-bus power system model with four areas.

Gusrialdi, Azwirman↗

Graph Laplacian Spectrum and Primary Frequency Regulation: Preprint

We present a framework based on spectral graph theory that captures the interplay among network topology, system inertia, and generator and load damping in determining overall power grid behavior and performance. Specifically, we show that the impact of network topology on a power system can be quantified through the network Laplacian eigenvalues, and such eigenvalues determine the grid robustness against low frequency disturbances. Moreover, we can explicitly decompose the frequency signal along scaled Laplacian eigenvectors when damping-intertia ratios are uniform across buses. The insight revealed by this framework suggests why load-side participation in frequency regulation not only makes the system respond faster, but also helps lower the system nadir after disturbance. Finally, by presenting a new controller specifically tailored to suppress high frequency disturbances, we demonstrate that our results can provide useful guidelines in the controller design for load-side primary frequency regulation. We simulate the improved controller on the IEEE 39-bus New England interconnection system to illustrate its robustness against high frequency oscillation compared to both the conventional droop control and a recent controller design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing the Optimality of LinDist3Flow for Optimal Tap Selection of Step Voltage Regulators in Unbalanced Distribution Networks

The adoption of distributed energy resources such as photovoltaics (PVs) has increased dramatically during the previous decade. The increased penetration of PVs into distribution networks (DNs) can cause voltage fluctuations that have to be mitigated. One of the key utility assets employed to this end are step-voltage regulators (SVRs). It is desirable to include tap selection of SVRs in optimal power flow (OPF) routines, a task that turns out to be challenging because the resultant OPF problem is nonconvex with added complexities stemming from accurate SVR modeling. While several convex relaxations based on semi-definite programming (SDP) have been presented in the literature for optimal tap selection, SDP based schemes do not scale well and are challenging to implement in large-scale planning or operational frameworks. This paper deals with the optimal tap selection (OPTS) problem for wye-connected SVRs using linear approximations of power flow equations. Specifically, the LinDist3Flow model is adopted and the effective SVR ratio is assumed to be continuous- enabling the formulation of a problem called LinDist3Flow-OPTS, which amounts to a linear program. The scalability and optimality gap of LinDist3Flow-OPTS are evaluated with respect to existing SDP-based and nonlinear programming techniques for optimal tap selection in three standard feeders, namely, the IEEE 13-bus, 123-bus, and 8500-node DNs. For all DNs considered, LinDist3Flow-OPTS achieves an optimality gap of approximately 1% or less while significantly lowering the computational burden.

linear approximations↗

Network-Aware and Welfare-Maximizing Dynamic Pricing for Energy Sharing

The proliferation of behind-the-meter (BTM) distributed energy resources (DER) within the electrical distribution network presents significant supply and demand flexibilities, but also introduces operational challenges such as voltage spikes and reverse power flows. In response, this paper proposes a network-aware dynamic pricing framework tailored for energy-sharing coalitions that aggregate small, but ubiquitous, BTM DER downstream of a distribution system operator's (DSO) revenue meter that adopts a generic net energy metering (NEM) tariff. By formulating a Stackelberg game between the energy-sharing market leader and its prosumers, we show that the dynamic pricing policy induces the prosumers toward a network-safe operation and decentrally maximizes the energysharing social welfare. The dynamic pricing mechanism involves a combination of a locational ex-ante dynamic price and an ex-post allocation, both of which are functions of the energy sharing's BTM DER. The ex-post allocation is proportionate to the price differential between the DSO NEM price and the energy-sharing locational price. Simulation results using real DER data and the IEEE 13-bus test systems illustrate the dynamic nature of network-aware pricing at each bus, and its impact on voltage.

aggregates↗

Strym: A Python Package for Real-time CAN Data Logging, Analysis and Visualization to Work with USB-CAN Interface

In this report, we describe a data analysis tool developed for decoding and analyzing vehicle data obtained from a passenger vehicle’s onboard controller area network (CAN) bus. The tool developed in this paper provides a timeseries framework to perform domain-specific analysis at scale when interpreting data from a vehicle or a collection of vehicles in light of how to design intelligent vehicle applications. The tool, called Strym, exploits the CAN bus mechanism of modern vehicles to capture data using commercially available CAN-to-USB hardware Comma.ai Panda devices, managed through open-source software Libpanda. Strym permits the decoding of vendor-specific CAN messages in a vehicle-agnostic manner. Through this, a researcher can characterize data throughput, assess data quality, and perform analyses. Such analyses are useful in a number of research such as studying human driving behavior in mixed-autonomy, new driver models, rare-event detection, traffic flow estimation, and custom control of vehicles.

Performance evaluation, Smart cities, Intelligent ↗

Assessment of System Frequency Support Effect of PMSG-WTG Using Torque-Limit-Based Inertial Control

To release the 'hidden inertia' of variable-speed wind turbines for temporary frequency support, a method of torque-limit-based inertial control is proposed in this paper. This method aims to improve the frequency support capability considering the maximum torque restriction of a permanent magnet synchronous generator. The advantages of the proposed method are improved frequency nadir (FN) in the event of an under-frequency disturbance; and avoidance of over-deceleration and a second frequency dip during the inertial response. The system frequency response is different, with different slope values in the power-speed plane when the inertial response is performed. The proposed method is evaluated in a modified three-machine, nine-bus system. The simulation results show that there is a trade-off between the recovery time and FN, such that a gradual slope tends to improve the FN and restrict the rate of change of frequency aggressively while causing an extension of the recovery time. These results provide insight into how to properly design such kinds of inertial control strategies for practical applications.

17 WIND ENERGY↗

Control of SiC Based Integrated DC-DC Powertrain Charger for Electric Vehicles

In this paper, an automated controller for an integrated, reconfigurable dc-dc converter for plugin electric vehicles (EVs) is presented. The integrated converter combines both an interleaved boost converter and dual active bridge (DAB) converter, sharing magnetics and switching devices. The converter switches between operating modes using the existing battery management system (BMS) contactors. The integrated converter operates in isolated DAB mode during battery charging operation. During traction operation, the integrated converter is operated in interleaved boost mode for heavy load and DAB mode during light load, high voltage operation. An online transition algorithm is used to transition from interleaved boost mode to DAB mode with minimal bus distortion. The automated controller selects the operating mode and inverter bus voltage at different torque-speed conditions to get maximum overall traction drive efficiency. An experimental prototype of the integrated converter demonstrates the automated controller functionality.

Anwar, Saeed↗

Active SOC Balancing for a Multi-Chemistry Battery Pack with Reduced Number of Converters

In energy storage systems using second-life or multi-chemistry cells, an active state of charge (SOC) balancing system can prolong pack life and enhance performance by utilizing the healthier cells more than those which are heavily degraded. However, the high cost of the active balancing system, particularly in converter-based solutions, prevents their widespread usage. Considering this, existing research has proposed numerous balancing systems utilizing only one converter. However, such systems may compromise the balancing speed too much. Therefore, this work proposes two active balancing systems with a reduced number of converters for 14-16 series-connected cells. One system uses two converters for direct cell-to-cell balancing. The other uses a time-multiplexed approach to exchange energy via an auxiliary low-voltage (LV) bus using four converters. The proposed balancing systems are compared to two baseline systems, a single converter cell-to-cell balancing system, and a 14 converter balancing system with an auxiliary LV bus.

battery pack↗

Design, Optimization, and Validation of GaN-Based DAB Converter for Active Cell Balancing in BTMS Applications

This paper focuses on the design of a bidirectional dual active bridge (DAB) DC/DC converter that utilizes Gallium Nitride (GaN) switches as active components. In the existing literature, MOSFET-based DAB for active cell balancing is available, but GaN-based DAB converter for active cell balancing is still new. The proposed modular isolated GaN-based DAB converter is designed as an individual module of active cell balancing for behind-the-meter storage (BTMS) applications, targeting high-power charging stations. Modular isolated converters are connected to each cell (low voltage bus), and each cell is connected in series to build up a battery module. According to the reference current command of supervisory control, each DAB converter can transfer power back and forth through the high voltage (HV) bus to balance the State of Charge (SoC) between the cells. Each module DAB converter is designed at a 50 W power rating. Switch power and transformer losses are analyzed for different switching frequencies, showing the optimum switching frequency for minimum losses. Furthermore, the procedure to select the required gate driver and the PCB layout optimization are discussed. Finally, the DAB performance analysis of GaN-based DAB and Si-based DAB is provided for a battery module operating with a LiFeMnPO4 prismatic cell with 3.2V 20Ah rated values.

active cell balancing↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

Development of a Distribution Optimal Power Flow Federate for Open-Source OEDI-SI Platform

Increasing numbers of distributed generators in the electric power distribution networks require developing a control strategy to optimize solutions in real time. Linearized optimal distribution flow development has seen growth and acceptance in the distribution systems literature for efficiently modeling the \glspl{opf} for distribution systems. This paper examines the implementation and integration procedure for linearized optimal distribution flow federate to \gls{oedisi} platform. Specifically, we discuss i) the usage of the \gls{oedisi} platform, ii) obtaining a tractable solution using developed \gls{opf} federate, and iii) validation of solutions and bench-marking the \gls{oedisi} platform with developed \gls{opf} federate using OpenDSS. In brief, we demonstrate how a general linearized optimal distribution flow federate can be developed and integrated with a co-simulation environment to mimic real-world examples. The efficacy of the proposed method is demonstrated using the IEEE 123-bus test system under different scenarios to obtain a tractable solution and compare its results.

Sadnan, Rabayet↗

Bulk Grid Frequency Support Using Electrolyzers

Increasing renewable penetration in the bulk power systems has resulted in declining inertial response of the generation during system disturbances. This results in larger frequency deviations and oscillations during such events. This paper proposes a strategy for controlled dispatch of electrolyzers as loads to improve the system’s frequency response. A droop based controller with constraints based on electrolyzer operating limits has been developed to regulate its load. Consecutively, a localized frequency based control strategy has been developed to support the bulk system during disturbances. The impact of the electrolyzer support has been demonstrated using the 23-bus SAVNW system, and the 240-bus WECC system for baseline, 25% and 50% renewable penetration. The impact of changing droop settings and the available controllable electrolyzer capacities on the system’s frequency response has also been presented. Overall, the dispatchable electrolyzers helps improve (reduce) both the maximum frequency deviation and the settling times during common disturbances like loss of load/generation, and line faults. Systems with lower inertia were seen to benefit more from the controlled electrolyzer dispatch.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Sparse Linear Solvers for Large-scale Electromagnetic Transient Simulations

Linear solvers form the basis for electromagnetic transient (EMT) simulations. There is a need to speed up EMT simulations as larger regions are analyzed using EMT simulations. For the same, the performance of linear solvers plays an important role. Exploiting the sparsity of the matrices generated in EMT simulations could assist with speed-up. Scalability is also crucial as power grids expand, demanding solutions capable of accommodating the increasing system size. Recent studies from the North American Electric Reliability Corporation (NERC) increasingly emphasize that EMT simulation models of the power grid will grow larger with the inclusion of power electronics components. Parallelisms in sparsity patterns exploit modern central processing units (CPUs), multi-core CPUs, and graphics processing units (GPUs) architectures in sparse solver designs. Therefore, this paper explores publicly available existing linear solvers and investigates their efficiency in large-scale power grid simulations. A large-scale power grid is developed by increasing the size of the IEEE 39 bus test system to up to 39000 bus systems.

Hsu, Kuan-Chieh↗

EMT-TS Hybrid Simulation for Large Power Grids Considering IBR-Driven Dynamics

The escalating integration of inverter-based resources (IBRs) poses new challenges to power systems by introducing fast dynamics with higher frequencies, which may need to be simulated by an electromagnetic transient (EMT) program. As an alternative to conducting EMT simulations for the entire system, which is typically time consuming, hybrid simulation between EMT and phasor-domain transient stability (TS) can greatly reduce the computational burden while preserving the detailed fast dynamics in the EMT zone. This paper establishes an EMT-TS hybrid simulation platform using open-source tools, specifically ParaEMT, GridPACK, and HELICS, which are the EMT simulator, TS simulator, and interface framework, respectively. Case studies on the 240-bus Western Electricity Coordinating Council (WECC) system demonstrate that the developed ParaEMT-HELICS-GridPACK hybrid simulator can accurately capture both slow electromechanical and fast IBR-driven dynamics with a 2.4x speedup.

electromagnetic transient↗

Power System Decomposition for Practical Implementation of Bulk-Grid Voltage Control Methods

Power system algorithms such as AC optimal power flow and coordinated volt/var control of the bulk power system are computationally intensive and become difficult to solve in operational time frames. The computational time required to run these algorithms increases exponentially as the size of the power system increases. The solution time for multiple subsystems is less than that for solving the entire system simultaneously, and the local nature of the voltage problem lends itself to such decomposition. This paper describes an algorithm that can be used to perform power system decomposition from the point of view of the voltage control problem. Our approach takes advantage of the dominant localized effect of voltage control and is based on clustering buses according to the electrical distances between them. One of the contributions of the paper is to use multidimensional scaling to compute n-dimensional Euclidean coordinates for each bus based on electrical distance to perform algorithms like K-means clustering. A simple coordinated reactive power control of photovoltaic inverters for voltage regulation is used to demonstrate the effectiveness of the proposed decomposition algorithm and its components. The proposed decomposition method is demonstrated on the IEEE 118-bus system.

multidimensional scaling↗

Three-Phase AC Optimal Power Flow Based Distribution Locational Marginal Price

Designing market mechanisms for electricity distribution systems has been a hot topic due to the increased presence of smart loads and distributed energy resources (DERs) in distribution systems. The distribution locational marginal pricing (DLMP) methodology is one of the real-time pricing methods to enable such market mechanisms and provide economic incentives to active market participants. Determining the DLMP is challenging due to high power losses, the voltage volatility, and the phase imbalance in distribution systems. Existing DC Optimal Power Flow (OPF) approaches are unable to model power losses and the reactive power, while single-phase AC OPF methods cannot capture the phase imbalance. To address these challenges, in this paper, a three-phase AC OPF based approach is developed to define and calculate DLMP accurately. The DLMP is modeled as the marginal cost to serve an incremental unit of demand at a specific phase at a certain bus, and is calculated using the Lagrange multipliers in the three-phase AC OPF formulation. Extensive case studies have been conducted to understand the impact of system losses and the phase imbalance on DLMPs as well as the potential benefits of flexible resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗