Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Enhanced orbital gyrocompassing by the optical flow sensed by an Earth-pointing camera

A new method for improving the orbital gyrocompassing process involving the attitude angle estimation of an earth-pointing satellite in low-Earth orbit uses an electro-optical sensor for direct measurement of the satellite azimuth angle. Simulations have shown that this additional measurement drastically reduces the estimator convergence time, especially when the sun sensor is rendered ineffective, e.g., by high solar elevations. The azimuth-sensing method is based on estimation of the image shift between successive picture frames of an on-board, Earth-pointing, charge-coupled device (CCD) full-matrix camera. The shift-estimation algorithm is based on minimizing a cost function which expresses mean-squared differences in brightness patterns of selected areas of the two frames. An extensive evaluation program with a computer-controlled 2-axis light table and actual satellite images has demonstrated high robustness for a wide range of variation of parameters including image texture content; camera focal length; sampling rate; and number of pixels processed. It was shown to be possible to estimate the azimuth angle within 0.1-0.2 degrees, for a suitably chosen parameter set.

Topaz, Leora↗

CCD imaging instruments for planetary spacecraft applications

The development of new spacecraft camera systems to be used in conjunction with CCD sensors is reported. A brief overview of the science objectives and engineering constraints which influence the design of cameras for deep space is followed by a review of two current development programs, one leading to a line scan imager and the other to an area array frame camera. For each of these, a general description of the imager is given. It is evident that currently available CCDs fall short of requirements in some respects.

Reilly, T. H.↗

Elemental abundances of the B and A stars Gamma Geminorum, 7 Sextantis, HR 4817, and HR 5780

Fine analyses of the B and A stars, Gamma Geminorum, 7 Sextantis, HR 4817, and HR 5780 are performed. Although the data cover rather limited spectral regions, still useful results were obtained. The data were mostly obtained at the KPNO coude feed telescope with CCD TI No. 3, camera 5, and grating A. The He/H ratio of HR 4817 confirms the similarity of many abundance values with those of the peculiar Mn star 53 Tauri. For the most part Gamma Gem, 7 Sex, and HR 5780 have derived abundances similar to those of other normal sharp-lined stars of similar effective temperature.

Adelman, Saul J.↗

Searching for Lyman alpha emission from a possible Zel'dovich pancake

The detection of 2 x 10(exp 14) solar mass of neutral hydrogen at a redshift of 3.397 has been reported. Top-down theories of structure formation predict such a mass of hydrogen collapsing to form a protocluster of galaxies. We sought to observe this object in Lyman-alpha, which could be produced through ionization by the metagalactic ionizing radiation field or through internal ionization processes. On 29 Apr. 1992, the region of the reported HI emission for 1800 seconds with the 1.3 meter McGraw-Hill reflector at Michigan-Dartmouth-M.I.T. Observatory was observed. Because the H1 emission reported has a transverse scale of 300 sec, a 1/3.06 reducing camera and a Thomson CCD were used to obtain a field of view of about 600 sec by 840 sec. A filter 88 A wide, centered at 5354 A was used; Lyman-alpha emission at z = 3.4 is redshifted to 5347 A. In order to avoid saturating the CCD with a bright star in the field, nine 200 second exposures were taken. The combination of these images shows no obvious extended Lyman-alpha emission at a level of about 28 magnitudes per square arcsecond. The field observed also shows a distant cluster of galaxies. In order to determine if the cluster could in any way be associated with the cloud of neutral hydrogen at z = 3.4, we sought to estimate its redshift from the size and magnitude of the galaxies and of the cluster as a whole. Omega = 1 and H(sub O) = 50 km s(sup -1) Mpc(sup -1) were adopted; our redshift estimates range from z = 0.2 to z = 0.6. The cluster is clearly not associated with the HI cloud at z = 3.4.

Cox, Caroline↗

Contamination detection NDE for cleaning process inspection

In the joining of multilayer materials, and in welding, the cleanliness of the joining surface may play a large role in the quality of the resulting bond. No non-intrusive techniques are currently available for the rapid measurement of contamination on large or irregularly shaped structures prior to the joining process. An innovative technique for the measurement of contaminant levels in these structures using laser based imaging is presented. The approach uses an ultraviolet excimer laser to illuminate large and/or irregular surface areas. The UV light induces fluorescence and is scattered from the contaminants. The illuminated area is viewed by an image-intensified CCD (charge coupled device) camera interfaced to a PC-based computer. The camera measures the fluorescence and/or scattering from the contaminants for comparison with established standards. Single shot measurements of contamination levels are possible. Hence, the technique may be used for on-line NDE testing during manufacturing processes.

Marinelli, W. J.↗

Hyperspectral Imaging and Spectroscopy of Fluorescently Coupled Acyl-CoA: Cholesterol Acyltransferase in Insect Cells

A high-performance hyperspectral imaging module with high throughput of light suitable for low-intensity fluorescence microscopic imaging and subsequent analysis, including single-pixel-defined emission spectroscopy, was tested on Sf21 insect cells expressing green fluorescence associated with recombinant green fluorescent protein linked or not with the membrane protein acyl-CoA:cholesterol acyltransferase. The imager utilized the phenomenon of optical activity as a new technique providing information over a spectral range of 220-1400 nm, and was inserted between the microscope and an 8-bit CCD video-rate camera. The resulting fluorescence image did not introduce observable image aberrations. The images provided parallel acquisition of well resolved concurrent spatial and spectral information such that fluorescence associated with green fluorescent protein alone was demonstrated to be diffuse within the Sf21 insect cell, and that green fluorescence associated with the membrane protein was shown to be specifically concentrated within regions of the cell cytoplasm. Emission spectra analyzed from different regions of the fluorescence image showed blue shift specific for the regions of concentration associated with the membrane protein.

Malak, H.↗

Back in Time

Under a Jet Propulsion Laboratory SBIR (Small Business Innovative Research), Cambridge Research and Instrumentation Inc., developed a new class of filters for the construction of small, low-cost multispectral imagers. The VariSpec liquid crystal enables users to obtain multi-spectral, ultra-high resolution images using a monochrome CCD (charge coupled device) camera. Application areas include biomedical imaging, remote sensing, and machine vision.

Source record↗

Simultaneous Spectral Temporal Adaptive Raman Spectrometer - SSTARS

Raman spectroscopy is a prime candidate for the next generation of planetary instruments, as it addresses the primary goal of mineralogical analysis, which is structure and composition. However, large fluorescence return from many mineral samples under visible light excitation can render Raman spectra unattainable. Using the described approach, Raman and fluorescence, which occur on different time scales, can be simultaneously obtained from mineral samples using a compact instrument in a planetary environment. This new approach is taken based on the use of time-resolved spectroscopy for removing the fluorescence background from Raman spectra in the laboratory. In the SSTARS instrument, a visible excitation source (a green, pulsed laser) is used to generate Raman and fluorescence signals in a mineral sample. A spectral notch filter eliminates the directly reflected beam. A grating then disperses the signal spectrally, and a streak camera provides temporal resolution. The output of the streak camera is imaged on the CCD (charge-coupled device), and the data are read out electronically. By adjusting the sweep speed of the streak camera, anywhere from picoseconds to milliseconds, it is possible to resolve Raman spectra from numerous fluorescence spectra in the same sample. The key features of SSTARS include a compact streak tube capable of picosecond time resolution for collection of simultaneous spectral and temporal information, adaptive streak tube electronics that can rapidly change from one sweep rate to another over ranges of picoseconds to milliseconds, enabling collection of both Raman and fluorescence signatures versus time and wavelength, and Synchroscan integration that allows for a compact, low-power laser without compromising ultimate sensitivity.

Blacksberg, Jordana↗

Multiple Velocity Profile Measurements in Hypersonic Flows Using Sequentially-Imaged Fluorescence Tagging

Nitric-oxide planar laser-induced fluorescence (NO PLIF) was used to perform velocity measurements in hypersonic flows by generating multiple tagged lines which fluoresce as they convect downstream. For each laser pulse, a single interline, progressive scan intensified CCD (charge-coupled device) camera was used to obtain two sequential images of the NO molecules that had been tagged by the laser. The CCD configuration allowed for sub-microsecond acquisition of both images, resulting in sub-microsecond temporal resolution as well as sub-mm spatial resolution (0.5-mm horizontal, 0.7-mm vertical). Determination of axial velocity was made by application of a cross-correlation analysis of the horizontal shift of individual tagged lines. A numerical study of measured velocity error due to a uniform and linearly-varying collisional rate distribution was performed. Quantification of systematic errors, the contribution of gating/exposure duration errors, and the influence of collision rate on temporal uncertainty were made. Quantification of the spatial uncertainty depended upon the signal-to-noise ratio of the acquired profiles. This velocity measurement technique has been demonstrated for two hypersonic flow experiments: (1) a reaction control system (RCS) jet on an Orion Crew Exploration Vehicle (CEV) wind tunnel model and (2) a 10-degree half-angle wedge containing a 2-mm tall, 4-mm wide cylindrical boundary layer trip. The experiments were performed at the NASA Langley Research Center's 31-Inch Mach 10 Air Tunnel.

Bathel, Brett F.↗

VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

Camera↗

Restoration of HST images with missing data

Missing data are a fairly common problem when restoring Hubble Space Telescope observations of extended sources. On Wide Field and Planetary Camera images cosmic ray hits and CCD hot spots are the prevalent causes of data losses, whereas on Faint Object Camera images data are lossed due to reseaux marks, blemishes, areas of saturation and the omnipresent frame edges. This contribution discusses a technique for 'filling in' missing data by statistical inference using information from the surrounding pixels. The major gain consists in minimizing adverse spill-over effects to the restoration in areas neighboring those where data are missing. When the mask delineating the support of 'missing data' is made dynamic, cosmic ray hits, etc. can be detected on the fly during restoration.

Adorf, Hans-Martin↗

Thermal Design of the Instrument for the Transiting Exoplanet Survey Satellite

TESS observatory is a two year NASA Explorer mission which will use a set of four cameras to discover exoplanets. It will be placed in a high-earth orbit with a period of 13.7 days and will be unaffected by temperature disturbances caused by environmental heating from the Earth. The cameras use their stray-light baffles to passively cool the cameras and in turn the CCD's in order to maintain operational temperatures. The design has been well thought out and analyzed to maximize temperature stability. The analysis shows that the design keeps the cameras and their components within their temperature ranges which will help make it a successful mission. It will also meet its survival requirement of sustaining exposure to a five hour eclipse. Official validation and verification planning is underway and will be performed as the system is built up. It is slated for launch in 2017.

Thermal Engineering↗

Range and range rate system

A video controlled solid state range finding system which requires no radar, high power laser, or sophisticated laser target is disclosed. The effective range of the system is from 1 to about 200 ft. The system includes an opto-electric camera such as a lens CCD array device. A helium neon laser produces a source beam of coherent light which is applied to a beam splitter. The beam splitter applies a reference beam to the camera and produces an outgoing beam applied to a first angularly variable reflector which directs the outgoing beam to the distant object. An incoming beam is reflected from the object to a second angularly variable reflector which reflects the incoming beam to the opto-electric camera via the beam splitter. The first reflector and the second reflector are configured so that the distance travelled by the outgoing beam from the beam splitter and the first reflector is the same as the distance travelled by the incoming beam from the second reflector to the beam splitter. The reference beam produces a reference signal in the geometric center of the camera. The incoming beam produces an object signal at the camera.

Graham, Olin L.↗

Geometry of the Hubble Space Telescope Wide Field/Planetary Camera field

We present a solution for the relative positions and orientations of the four charge coupled device (CCD) chips on the Hubble Space Telescope (HST) Planetary Camera (PC). An accurate solution is required when matching HST images with ground-based images or with one another. The solution is accurate to about 2/3 PC pixel or about .03 sec, a tenfold improvement over the best previous solution. The CCDs are rotated relative to one another by up to 1 deg. The solution is based on images taken between December 1990 and June 1992 and is stable over that entire period. We also present a solution for the relative positions and orientations of the four CCD chips on the HST Wide Field Camera (WFC). This solution is accurate to about 1/2 WFC pixel or about .05 sec.

Gould, Andrew↗

Replacing a technology - The Large Space Telescope and CCDs

The technological improvements, design choices and mission goals which led to the inclusion of CCD detectors in the wide field camera of the Large Space Telescope (LST) to be launched by the STS are recounted. Consideration of CCD detectors began before CCDs had seen wide astronomical applications. During planning for the ST, in the 1960s, photographic methods and a vidicon were considered, and seemed feasible provided that periodic manual maintenance could be performed. The invention of CCDs was first reported in 1970 and by 1973 the CCDs were receiving significant attention as potential detectors instead of a vidicon, which retained its own technological challenges. The CCD format gained new emphasis when success was achieved in developments for planetary-imaging spacecraft. The rapidity of progress in CCD capabilities, coupled with the continued shortcomings of the vidicon, resulted in a finalized choice for a CCD device by 1977. The decision was also prompted by continuing commercial and military interest in CCDs, which was spurring the development of the technology and improving the sensitivities and reliability while lowering the costs.

Smith, R. W.↗

Method and apparatus for ultra-high-sensitivity, incremental and absolute optical encoding

An absolute optical linear or rotary encoder which encodes the motion of an object (3) with increased resolution and encoding range and decreased sensitivity to damage to the scale includes a scale (5), which moves with the object and is illuminated by a light source (11). The scale carries a pattern (9) which is imaged by a microscope optical system (13) on a CCD array (17) in a camera head (15). The pattern includes both fiducial markings (31) which are identical for each period of the pattern and code areas (33) which include binary codings of numbers identifying the individual periods of the pattern. The image of the pattern formed on the CCD array is analyzed by an image processor (23) to locate the fiducial marking, decode the information encoded in the code area, and thereby determine the position of the object.

Leviton, Douglas B.↗

Periodic Comet Shoemaker-Levy 9 (1993e)

Preliminary results of analysis of CCD photometry obtained with the Planetary Camera on the Hubble Space Telescope(HST) ... suggest that the deconvolved signal for the largest fragment in each nuclear condensation does not appear to depend strongly on the law employed to subtract the contribution from the dust cloud within about 0.35 arcsec around the brightest pixel.

CCD photometry planetary camera Hubble Space Teles↗

Television applications of interline-transfer CCD arrays

The design features and characteristics of interline transfer (ILT) CCD arrays with 190 x 244 and 380 x 488 image elements are reviewed, with emphasis on optional operating modes and system application considerations. It was shown that the observed horizontal resolution for a TV system using an ILT image sensor can approach the aperture response limit determined by photosensor site width, resulting in enhanced resolution for moving images. Preferred camera configurations and read out clocking modes for maximum resolution and low light sensitivity are discussed, including a very low light level intensifier CCD concept. Several camera designs utilizing ILT-CCD arrays are described. These cameras demonstrate feasibility in applications where small size, low-power/low-voltage operation, high sensitivity and extreme ruggedness are either desired or mandatory system requirements.

Hoagland, K. A.↗