Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configuration Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Comparison Between Numerical and Experimental Results on Mechanical Stirrer and Bubbling in a Cylindrical Tank - 13047

The process of vitrification in a cold crucible heated by direct induction is used in the fusion of oxides. Its feature is the production of high-purity materials. The high-level of purity of the molten is achieved because this melting technique excludes the contamination of the charge by the crucible. The aim of the present paper is to analyze the hydrodynamic of the vitrification process by direct induction, with the focus in the effects associated with the interaction between the mechanical stirrer and bubbling. Considering the complexity of the analyzed system and the goal of the present work, we simplified the system by not taking into account the thermal and electromagnetic phenomena. Based in the concept of hydraulic similitude, we performed an experimental study and a numerical modeling of the simplified model. The results of these two studies were compared and showed a good agreement. The results presented in this paper in conjunction with the previous work contribute to a better understanding of the hydrodynamics effects resulting from the interaction between the mechanical stirrer and air bubbling in the cold crucible heated by direct induction. Further works will take into account thermal and electromagnetic phenomena in the presence of mechanical stirrer and air bubbling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Dynamics of Carbon Steel in Small, Stagnant Volume under Radiation

The long term disposal of used nuclear fuel involves a deep geological repository (DGR) with the key barrier being the Used Fuel Container (UFC) consisting of a copper-coated carbon steel vessel. NWMO's Mark II design UFC is assembled by welding the semi-spherical head to a cylindrical body. Crevice is formed between the two parts along with the weld region. The objective of this research is to develop and validate a reliable corrosion model for long-term corrosion of CS under DGR condition. Water radiolysis produces chemically reactive species that affect corrosion rates and pathways. This work explores the synergistic effects of γ-radiation and solution properties on the dynamics of carbon steel corrosion. In Stage 1, corrosion rate is controlled by dissolution of iron to the solution phase. In Stage 2, the controlling processes are the growth of iron hydroxide gel. In Stage 3, the main iron redox reaction is the conversion between different iron oxides, and the overall corrosion rate is negligible. The concentration of Fe{sup 2+} (aq) near the metal surface reaches its solubility limit very quickly in a small, stagnant volume. Diffusion from crevice to bulk solution is more significant with larger crevice size. Porous, granular form of magnetite loosely attached to the metal surface is formed from Fe{sup 3+} in solution via reduction by H{sub 2}O{sub 2}. As a source of continuous formation of H{sub 2}O{sub 2}, radiation accelerates oxidation (Fe0 → Fe{sup 2+} → Fe{sup 3+}). Once the oxidation is almost complete, H{sub 2}O{sub 2} can act as a reducing reagent, reducing Fe{sup 3+} species back to Fe{sup 2+} forming more stable mixed Fe{sup 2+,3+} species (magnetite and maghemite)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Analysis for SRS Saltstone Disposal Unit Facility

Saltstone Disposal Units (SDU) are long term disposal units for low activity grout produced from the solidification of decontaminated non-hazardous salt waste at SRS. The unit is a cylindrical disposal vault of 150 ft. in diameter and 23 ft. in height. The total volume the SDU can hold is 3 million gallons of grout. The hydration process of the grout material produces heat from an exothermic chemical reaction. If the grout reaches temperatures higher than the maximum safety temperature of 95 deg. C, cracks can start forming leading to contamination of the environment. The purpose of this study is to develop the optimal baseline domain boundary conditions and to perform a sensitivity analysis with respect to the baseline modeling conditions. The following assumptions were made for the modeling calculations: - The system geometry is axisymmetric; - The system was at steady state; - Ambient temperature was set to 100 deg. F; - Air was assumed to be an incompressible ideal gas; - Radiation was neglected for a conservative estimation; - Natural convection for the SDU vapor space is assumed to be turbulent because Rayleigh number based on typical operating conditions is higher than 10{sup 8}; - Water tables were not taken into consideration. The following sensitivity analyses were performed to find the optimal domain boundary: - Mesh size sensitivity; - Soil depth sensitivity - Soil depth varied from 30 ft to 250 ft with a soil thickness of 90 ft; - Soil thickness sensitivity - Soil thickness varied from 30 ft to 270 ft with a soil depth of 180 ft; - Soil conductivity sensitivity - Soil thermal conductivity varied from 0.25 W/m-K to 1 W/m-K; - Ambient Temperature Sensitivity - Ambient temperature varied from 70 deg. F to 110 deg. F. For the thermal calculations, the temperature of the bottom of the soil was set to 17.4 deg. C. The heat flux on the roof of the building and surface of the earth is 163.2 W/m{sup 2}. The soil sides are set to be adiabatic. The sensitivity analysis shows that the mesh size has no effect on the numerical results. This is mainly due to a small convection zone and large conduction zones in the modeling domain. The optimal domain boundary was found to be a soil thickness of 90 ft and a soil depth of 150 ft. The different sensitivity analysis performed here shows the optimal boundary domain to be used for thermal calculations is a soil depth of 150 ft beneath the SDU and a soil thickness of 90 ft. Anything larger would produce similar solutions but at a longer computational time to solve. The maximum temperature was more sensitive to soil properties as shown here. While the ambient temperature affected the max temperature linearly. Most of the heat transfer takes place downward vertically between the SDU and the soil beneath it. Using the optimal domain boundary determined by the sensitivity analyses, the maximum thermal loading to keep the maximum grout temperature below 95 deg. C is 1.646 W/m{sup 3}.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

OVERVIEW OF ACTIVITIES BY THE U.S. DOMESTIC AGENCY

The U.S. Domestic Agency is now fully staffed and configured to provide the U.S. hardware, personnel, and cash contributions to the ITER Project. It has applied its resources to resolution of remaining technical design issues and to implementing systems that enable effective design and manufacture, with emphasis on risk management. Progress in the technical and project management areas is described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Configurable DERMS Test System in GridAPPS-D

Distributed Energy Resources and their increased penetration within the power grid are a suitable method to provide essential reliability services. In order to do so, they must operate in aggregate. Aggregation of a wide variety of systems with varying standards and protocols is a complex task, which could benefit from rules and standards to support interoperability. To this end, the Portland State University Power Lab has developed the Energy Grid of Things project, which includes a Distributed Energy Resource Management System to provide aggregation and demonstrate the usage of an Energy Services Interface: a set of rules governing the interface between resource owners and aggregator businesses. This thesis presents a Modeling Environment that provides a simulation and test platform reflecting the complex needs of an aggregator. A grid simulator is required that is able to reflect the effects of thousands of Distributed Energy Resources operating in tandem; furthermore, these effects must be communicated to external actors such as the Grid Operator, which provides grid service requests to the aggregator and requires feedback. The Modeling Environment provides all of this functionality by leveraging the GridAPPS-D platform to develop an interoperable class-based system that provides configurable simulations with modular input and output APIs. The Modeling Environment uses abstractions to allow any feasible type of input to be reflected within the model as a Distributed Energy Resource, and serves as a proof-of-concept for the development of aggregation simulation and testing within GridAPPS-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Selenite and selenate uptaken in ettringite: Immobilization mechanisms, coordination chemistry, and insights from structure

Although ettringite is a crucial material in terms of Se immobilization, the immobilization mechanisms, atomic configuration, and intercolumn structure of Se sorbed in ettringite are unclear. The immobilization mechanism of Se oxoanions was evaluated through structural insight into ettringite. It is contrasting between SeO{sub 3}{sup 2−} and SeO{sub 4}{sup 2−} in chemical property of the solid residues after immobilization. The oxoanion exchange with structural SO{sub 4}{sup 2−} is the main mechanism for immobilization of SeO{sub 4}{sup 2−}. In contrast, SeO{sub 3}{sup 2−} is easily immobilized to form inner-sphere complexes in ettringite. In addition, it is necessary to reveal the SeO{sub 3}{sup 2−} complexation sites for understanding the mechanisms in immobilization of SeO{sub 3}{sup 2−}. Based on the characterization results with the bond valence theory, the location sites of sorbed SeO{sub 3}{sup 2−} in ettringite structure were proposed. The results obtained in this work are relevant to the understanding of Se and its isotopes immobilized in cement or alkaline environments, especially for nuclear waste management. - Highlights: • The immobilization mechanisms of SeO{sub 3}{sup 2−} and SeO{sub 4}{sup 2−} in ettringite are different. • Sorption of SeO{sub 3}{sup 2−} will remove structural water molecules in ettringite. • SeO{sub 3}{sup 2−} could form some inner-sphere complexes in the ettringite structure. • The EXAFS and bond valence theory was applied to determine the sorption mechanism. • The atomic configuration of ettringite surface was proposed after sorption of SeO{sub 3}{sup 2−}.

36 MATERIALS SCIENCE↗

Economic analysis of municipal wastewater utilization for thermoelectric power production

The thermoelectric power industry in the U.S. uses a large amount of freshwater. The large water demand is increasingly a problem, especially for new power plant development, as availability of freshwater for new uses diminishes in the United States. Reusing non-traditional water sources, such as treated municipal wastewater, provides one option to mitigate freshwater usage in the thermoelectric power industry. The amount of freshwater withdrawal that can be displaced with non-traditional water sources at a particular location requires evaluation of the water management and treatment requirements, considering the quality and abundance of the non-traditional water sources. This paper presents the development of an integrated costing model to assess the impact of degraded water treatment, as well as the implications of increased tube scaling in the main condenser. The model developed herein is used to perform case studies of various treatment, condenser cleaning and condenser configurations to provide insight into the ramifications of degraded water use in the cooling loops of thermoelectric power plants. Further, this paper lays the groundwork for the integration of relationships between degraded water quality, scaling characteristics and volatile emission within a recirculating cooling loop model.

97 MATHEMATICS AND COMPUTING↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?

Variation in the electrical conductivity (EC) of water can reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. Broader application of open source (OS) EC sensors could provide an inexpensive method to measure water quality. While studies show that other water quality parameters can be robustly measured with sensors, a similar effort is needed to evaluate the performance of OS EC sensors. To address this need, we evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. We found a significant difference between OS sensor mean accuracy (3.08%) and all other sensors combined (9.23%). Our study also found that EC sensor precision decreased across all sensor configurations with increasing calibration standard EC. There was also a significant difference between OS sensor mean precision (2.85 μS/cm) and the mean precision of all other sensors combined (9.12 μS/cm). Cable length did not affect OS sensor precision. Furthermore, our results suggest that future research should include evaluating how performance is impacted by combining OS sensors with commercial data loggers as this study found significantly decreased performance in OS/commercial-hybrid sensor configurations. To increase confidence in the reliability of OS sensor data, more studies such as ours are needed to further quantify OS sensor performance in terms of accuracy and precision across different settings and OS sensor and data collection platform configurations.

54 ENVIRONMENTAL SCIENCES↗

Hanford Double Shell Waste Tank Corrosion Studies (Final Report FY2023)

For fiscal year (FY) 2023, the Savannah River National Laboratory (SRNL) focused on two experimental tasks related to Hanford Double Shell Tank (DST) chemistry and integrity. The first task focused on understanding risk of corrosion due to formation of either continuous layers or discrete patches of solids on the tanks’ inner sidewalls and bottoms. Differences in the conductivity between various layers of the tank (e.g., solids, liquid, etc.) could result in differences in the electrochemical potential of the tank metal at various locations. The electrochemical potential difference may result in a corrosion current between the coupled surfaces. In FY23, SRNL investigated test configurations and protocols that could evaluate the presence of a galvanic couple between the tank bottom and the tank wall.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Distributed Energy Resources to Supply Reactive Power for Dynamic Voltage Regulation

Abstract Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a DE source with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction of multiple DE at different locations under different load levels may have an impact to the control parameter setting for each individual DE control system. Future research is needed to find out the interaction of DEs to identify the optimal control parameter settings with the consideration of many factors such as system configuration, load variation, and so on

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed multi-input multi-output control theoretic method to manage heterogeneous systems

A processing unit includes a plurality of subsystem control modules. Each subsystem control module includes a set of one or more inputs that receives a set of one or more external signals and a set of one or more monitored outputs from a hardware subsystem corresponding to the subsystem control module, and a set of configuration outputs for controlling one or more configuration settings of the hardware subsystem. The subsystem control module determines the one or more configuration settings based on the set of monitored outputs and on one or more targets derived from the set of external signals.

Pothukuchi, Raghavendra Pradyumna↗

Middleware Case Study: MeDICi

In many application domains in science and engineering, data produced by sensors, instruments and networks is naturally processed by software applications structured as a pipeline . Pipelines comprise a sequence of software components that progressively process discrete units of data to produce a desired outcome. For example, in a Web crawler that is extracting semantics from text on Web sites, the first stage in the pipeline might be to remove all HTML tags to leave only the raw text of the document. The second step may parse the raw text to break it down into its constituent grammatical parts, such as nouns, verbs and so on. Subsequent steps may look for names of people or places, interesting events or times so documents can be sequenced on a time line. Each of these steps can be written as a specialized program that works in isolation with other steps in the pipeline. In many applications, simple linear software pipelines are sufficient. However, more complex applications require topologies that contain forks and joins, creating pipelines comprising branches where parallel execution is desirable. It is also increasingly common for pipelines to process very large files or high volume data streams which impose end-to-end performance constraints. Additionally, processes in a pipeline may have specific execution requirements and hence need to be distributed as services across a heterogeneous computing and data management infrastructure. From a software engineering perspective, these more complex pipelines become problematic to implement. While simple linear pipelines can be built using minimal infrastructure such as scripting languages, complex topologies and large, high volume data processing requires suitable abstractions, run-time infrastructures and development tools to construct pipelines with the desired qualities-of-service and flexibility to evolve to handle new requirements. The above summarizes the reasons we created the MeDICi Integration Framework (MIF) that is designed for creating high-performance, scalable and modifiable software pipelines. MIF exploits a low friction, robust, open source middleware platform and extends it with component and service-based programmatic interfaces that make implementing complex pipelines simple. The MIF run-time automatically handles queues between pipeline elements in order to handle request bursts, and automatically executes multiple instances of pipeline elements to increase pipeline throughput. Distributed pipeline elements are supported using a range of configurable communications protocols, and the MIF interfaces provide efficient mechanisms for moving data directly between two distributed pipeline elements.

99 GENERAL AND MISCELLANEOUS↗

Reconstruction framework advancements to support streaming for the ePIC detector at the EIC

The ePIC collaboration adopted the JANA2 framework to manage its reconstruction algorithms. This framework has since evolved substantially in response to ePIC’s needs. There have been three main design drivers: integrating cleanly with the Podio-based data models and other layers of the key4hep stack, enabling external configuration of existing components, and supporting timeframe splitting for streaming readout. The result is a unified component model featuring a new declarative interface for specifying inputs, outputs, parameters, services, and resources. This interface enables the user to instantiate, configure, and wire components via an external file. One critical new addition to the component model is a hierarchical decomposition of data boundaries into levels such as Run, Timeframe, PhysicsEvent, and Subevent. Two new component abstractions, Folder and Unfolder, are introduced in order to traverse this hierarchy, e.g. by splitting or merging. The pre-existing components can now operate at different event levels, and JANA2 will automatically construct the corresponding parallel processing topology. This means that a user may write an algorithm once, and configure it at runtime to operate on timeframes or on physics events. Overall, these changes mean that the user requires less knowledge about the framework internals, obtains greater flexibility with configuration, and gains the ability to reuse the existing abstractions in new streaming contexts.

Brei, Nathan [Thomas Jefferson National Accelerato↗

Field Demonstration of The Krauklis Seismic Wave In A Novel Mva Method For Geologic CO 2 Storage

The Energy & Environmental Research Center (EERC) conducted a feasibility study of a new, low-impact geophysics monitoring method designed to incrementally track the saturation front of CO 2 injected into a reservoir. The method leverages a new way of transmitting energy from the surface to the reservoir and employs a new subsurface signal called the Krauklis wave (K-wave) and other guided waves for seismic monitoring. The EERC partnered with Seismos, Inc., the company that holds the exclusive technology license for this method, to advance development of K-wave technology, and Denbury Onshore, LLC, to field-test the system. The system was field-tested at Denbury’s Bell Creek oil field, currently undergoing CO 2 -based enhanced oil recovery (EOR) in southeastern Montana. The K-wave system uses a wellhead-mounted source to propagate energy down the wellbore in the form of a tube wave and through the well perforations into the reservoir. Part of the energy transmitted through the perforations into the reservoir converts to slow moving K-waves and/or other guided waves that are expected to propagate through the formation to neighboring wells. The propagated signal would induce tube waves in the neighboring wells that return to the surface to be recorded with a wellhead-mounted receiver. The propagation time of the signal is directly affected by the presence of CO 2 between the wells, so the difference in transit time of the returning signal between pre- and postinjection data sets could be used to help define the lateral extent of a CO 2 saturation front. Objectives of the study were to demonstrate, validate, and evaluate the K-wave method’s ability to monitor the morphology of injected CO 2 and estimate saturation distribution. Results from the demonstration were to be compared to conventional 4-D surface seismic methods, dynamic reservoir simulations, and CO 2 breakthrough data to validate the technology and provide useful information that may result in improvements. Prior to mobilizing for the full-scale K-wave baseline survey, a field test was conducted to better understand wellhead hardware configurations and test the response from the Bell Creek reservoir using three wells. Useful operational information resulted but signal from the first-generation gas release/gas injection source was not recorded in neighboring wells. After the initial field test, numerical modeling of the K-wave method was initiated using parameters specific to the Bell Creek Field. Modeling results indicated that the fundamental concepts behind the K-wave method exhibited problems and revealed a significantly greater attenuation of the signal at the wellbore perforations than expected, totaling on the order of 10-8 from source well to receiver well over a 400-m well spacing. Modeling also showed that greater source frequency bandwidth was needed to produce guided waves within a 30-foot-thick reservoir layer such as that at Bell Creek and that reservoir layer seismic velocity would need to be slower than the velocities of the bounding layers in order to act as a wave guide opposite to what exists at Bell Creek. Modeling results prompted a second field test with a stronger, second-generation displacement source developed in the interim. Concurrent with the second field test, a 3-D seismic survey was acquired to serve as a baseline for project validation and to serve as a monitor data set for the portion of the project area where CO 2 injection had already commenced. The new source was tested using a four-well geometry and failed to produce a detectable signal, which appeared to confirm modeling results and indicated that the Bell Creek Field is not an ideal site for the K-wave test. It was concluded that a source with sufficient strength and bandwidth could not be built to overcome the factors discovered by the modeling within a reasonable amount of time. Several other sites undergoing CO 2 -based EOR were also evaluated; however, none of these sites was amenable because of geology, limitations of source and receiver hardware, or the advanced state of the CO 2 flood. In addition, two other configurations of the source and receiver layout were considered; however, these design modifications either changed the scope of the project or did not meet the goals of the Carbon Storage Program. In consultation with the U.S. Department of Energy (DOE) Project Manager and Technology Manager, a no-go decision was invoked to forego additional expenditures as the technology would not meet current project objectives. Project activities to date have moved the technology forward by developing modeling equations that can be applied elsewhere, advanced the state of wellhead sensors and sources, and spurred improvements to field operations. The 3-D seismic survey in the project area and the dynamic reservoir simulations done as part of this study have provided value for ongoing and future synergistic activities at Bell Creek related to DOE carbon storage goals.

54 ENVIRONMENTAL SCIENCES↗

Making Quality HPGe Gamma Ray Spectrum Measurements for Uranium: The Role of FRAM for Analysis, Quality Control and Enrichment Measurements, and Opportunities for Improved Quantification Documentation

Enrichment measurements are used in uranium safeguards verification and accountancy as both an attribute signature and in the interpretation of other nondestructive assay information, such as active interrogation for mass. Accurate and reliable assessments require quality information. The practices used to collect the raw data are therefore the crucial first step in managing the overall quality and uncertainty of the enrichment determination. This report discusses several topics associated with gamma-ray spectrum measurements of uranium using HPGe detectors. First a discussion of good data acquisition practices including physical setup, detector types and configurations, detector shielding and filtering, spectrum stabilization, and data acquisition protocols. Next is a discussion of analysis options to obtain isotopic composition and/or enrichment centered on the FRAM gamma ray isotopic analysis software. The report discusses the results of the development of a FRAM parameter file to perform classical Enrichment Meter Principle (EMP) analysis. Possible analysis and data acquisition issues (random summing, x-ray fluorescence peaks, peak interferences, shielding) that can affect FRAM analyses are also discussed. There is also a brief discussion of FRAM measurements in the field. Under the topic of uncertainty propagation and quantification in FRAM, uncertainty propagation verification methods and gaps in available uncertainty quantification data for uranium is covered. Suggestions are made for areas where ORNL can contribute to closing the identified uncertainty quantification gaps, and also to contributing nuclear data quality spectra to the research community.

61 RADIATION PROTECTION AND DOSIMETRY↗

Environmental Effects Assessment for Proposed Offshore Wind Farm off the Coast of Grays Harbor, Washington

Grays Harbor Wind LLC (GHW) is proposing to develop a floating offshore wind farm offshore of west Grays Harbor County, Washington (Grays Harbor). The proposed GHW Offshore Wind Project (Project) would entail construction, installation and operation of a 1,000-megawatt (MW) offshore wind farm consisting of approximately 75 floating units, each containing a floating foundation and wind turbine generator (WTG). The Project location is approximately 25 miles (21.7 nautical miles [nmi]) offshore west of Grays Harbor, at waters depths of 360 to 700 feet. The Pacific Northwest National Laboratory (PNNL) was contracted by Herrera Environmental Consultants, Inc. on behalf of GHW to carry out this preliminary scoping study to evaluate baseline conditions and potential effects on fish and marine mammals from development and operation of a floating offshore wind farm installed within a designated area off the coast of Washington1. Floating offshore wind units installed in an ocean environment as part of the Project would interact with marine wildlife. This Study report provides an initial data aggregation and analysis, using publicly available data, of the Project effects, both negative and positive, on the marine environment. The scope of this assessment is limited by the fact that the Project development is presently at the conceptual level. Data on marine organisms were aggregated and evaluated; however seabirds were evaluated by Herrera Environmental Consulting and, along with bats, were not included in the scope of this study. Significant additional work is necessary to characterize ocean, seafloor, and environmental conditions; select appropriate floating offshore wind technologies; identify construction methods and locations; and assess facility locations, including electrical interconnection. Data aggregation and analysis of seabirds and bats is also needed. Evaluation of the full range of potential environmental effects would be conducted following an award of a lease from the Bureau of Ocean Energy Management (BOEM) as part of the leasing, National Environmental Policy Act (NEPA)/State Environmental Policy Act (SEPA) environmental review and permitting processes. While this initial data aggregation and analysis uses best available public scientific information and current assumptions about the Project configuration, the effects discussed herein are based on the status of review to-date and may change as Project-specific details are developed.

17 WIND ENERGY↗