Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling system efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Night ventilation control strategies in office buildings

In moderate climates night ventilation is an effective and energy-efficient approach to improve the indoor thermal environment for office buildings during the summer months, especially for heavyweight construction. However, is night ventilation a suitable strategy for office buildings with lightweight construction located in cold climates? In order to answer this question, the whole energy-consumption analysis software EnergyPlus was used to simulate the indoor thermal environment and energy consumption in typical office buildings with night mechanical ventilation in three cities in northern China. The summer outdoor climate data was analyzed, and three typical design days were chosen. The most important factors influencing night ventilation performance such as ventilation rates, ventilation duration, building mass and climatic conditions were evaluated. When night ventilation operation time is closer to active cooling time, the efficiency of night ventilation is higher. With night ventilation rate of 10 ach, the mean radiant temperature of the indoor surface decreased by up to 3.9 C. The longer the duration of operation, the more efficient the night ventilation strategy becomes. The control strategies for three locations are given in the paper. Based on the optimized strategies, the operation consumption and fees are calculated. The results show that more energy is saved in office buildings cooled by a night ventilation system in northern China than ones that do not employ this strategy. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strong influence of convective heat transfer efficiency on the cooling benefits of green roof irrigation

Abstract By enhancing evapotranspiration (ET), green roofs provide cooling benefits for the urban environment and are recognized as a promising heat mitigation strategy. The evaporative cooling effects of green roofs strongly depend on the soil moisture conditions and thus irrigation may be needed to sustain the cooling benefits. It has been shown that the magnitude of cooling benefits offered by green roof irrigation varies spatially, but its controlling factors remain elusive. In this study, we combine a surface energy balance (SEB) model with global simulations generated by an improved Earth System Model to illustrate the key factors controlling the cooling benefits of green roof irrigation. We employ a simple irrigation scheme, which is only active when there is no ice in soil layers and when the soil moisture is below field capacity. As a result, most of the irrigation water leaves the green roof system via ET. We find that the magnitude and also the spatial variability of the cooling benefits of green roof irrigation are controlled by the irrigation amount, and a surface energy redistribution factor that encodes the efficiencies of different SEB components in transferring heat. Further analysis indicates that the enhancement of latent heat flux due to irrigation is largely balanced by the reduction of sensible heat flux on green roofs. Therefore, the amount of irrigation needed per unit decrease of green roof surface temperature is mainly controlled by the convective heat transfer efficiency. A lower convective heat transfer efficiency (e.g. under a lower wind speed) helps reduce the amount of irrigation needed per unit decrease of green roof surface temperature. This study highlights the importance of SEB in constraining the cooling benefits of green roof irrigation and provides valuable guidance for urban planners and policy makers in terms of heat mitigation and sustainable water management.

Wang, Linying (ORCID:0000000308769220)↗

Procurement Options for Low Temperature Geothermal Technologies at Federal Facilities

Federal agencies are moving towards more efficient and resilient facilities by increasingly implementing energy projects in an effort to meet federally mandated goals, agency needs, and administration priorities. Low temperature geothermal technologies, which include geothermal heat pumps (GHP) and district heating systems, can contribute to meeting these goals. These technologies provide facilities with heating and cooling while reducing facility energy use and improving resilience. However, in order to implement these solutions, federal facilities must identify and execute a strategy for the procurement of these technologies. Federal facilities have successfully completed energy efficiency projects using a variety of procurement options. The purpose of this document is to provide federal agencies with a comprehensive overview of the procurement options available for low temperature geothermal technologies and other energy efficiency projects. The procurement options discussed include third-party financing mechanisms such as energy saving performance contracts (ESPCs), ESPC energy sales agreements (ESPC ESAs), and utility energy service contracts (UESCs), as well as dedicated funds in the form of federal grants and appropriated funds.

15 GEOTHERMAL ENERGY↗

Cooling of Electric Motors Used for Propulsion on SCEPTOR

NASA is developing a suite of hybrid-electric propulsion technologies for aircraft. These technologies have the benefit of lower emissions, diminished noise, increased efficiency, and reduced fuel burn. These will provide lower operating costs for aircraft operators. Replacing internal combustion engines with distributed electric propulsion is a keystone of this technology suite, but presents many new problems to aircraft system designers. One of the problems is how to cool these electric motors without adding significant aerodynamic drag, cooling system weight or fan power. This paper discusses the options evaluated for cooling the motors on SCEPTOR (Scalable Convergent Electric Propulsion Technology and Operations Research): a project that will demonstrate Distributed Electric Propulsion technology in flight. Options for external and internal cooling, inlet and exhaust locations, ducting and adjustable cowling, and axial and centrifugal fans were evaluated. The final design was based on a trade between effectiveness, simplicity, robustness, mass and performance over a range of ground and flight operation environments.

Propulsion↗

New High-Strength Ni-based Alloys for High Temperature Service in Liquid Fluoride Salt Environments

The ever-increasing demand for higher system thermal efficiency necessitates the operation of power generation cycles and heat conversion systems for chemical processes at progressively higher temperatures. As the system operating temperature increases, fewer and fewer materials are available with the required mechanical properties and environmental compatibility. This dearth of materials is particularly acute in structural applications at temperatures above 700°C in liquid Fluoride Salt Cooled High-Temperature Reactors (FHRs) and Concentrated Solar Power (CSP) systems where liquid fluoride and/or liquid chloride salts are used for their high thermal capacity and low thermal conductivity to store and transport heat. It has been shown that fluorides and chlorides can degrade the properties of the material used for storage and transport due to corrosive effects thus affecting the performance and lifetime characteristics. Thus, materials used for storage and transport for fluoride/chloride-salt must at the minimum have good compatibility with the salt by exhibiting low corrosion rates at the required temperatures. In addition, since many of the components will be subject to stresses in service, they need to have sufficient strength to resist plastic deformation, and the resistance to time dependent creep deformation at these temperatures, and stress levels. Achieving the combination of these properties required for higher temperatures is particularly challenging considering traditionally, the expected lifetime of some of the components used in these systems are from 30 years (CSP) to 80 years (FHRs). Although 316 stainless steel and associated redox corrosion reduction techniques are being considered for use in the first generational systems, use of 316SS is limited to operating temperatures up to ~ 650°C, thereby resulting in lower reactor efficiencies. Hastelloy ® N, developed at ORNL in the 1950s-60s for molten salt service is currently the leading candidate FHR structural alloy but has inadequate creep properties at high temperatures. Using a computationally-guided approach, Oak Ridge National Laboratory had developed new high strength alloys strengthened by γ’ precipitates (about 2X the strength of Hastelloy ® N) in small laboratory-scale heats that show good resistance to corrosion by fluorides and improved creep rupture life at temperatures up to 850°C (U.S. Patent Application No. 13/833,357 entitled “High Strength Alloys for High Temperature Service in Liquid-Salt Cooled Energy Systems”- granted U. S. Patent No. 9,540,714).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress towards an Optimization Methodology for Combustion-Driven Portable Thermoelectric Power Generation Systems

Enormous military and commercial interests exist in developing quiet, lightweight, and compact thermoelectric (TE) power generation systems. This paper investigates design integration and analysis of an advanced TE power generation system implementing JP-8 fueled combustion and thermal recuperation. Design and development of a portable TE power system using a JP-8 combustor as a high temperature heat source and optimal process flows depend on efficient heat generation, transfer, and recovery within the system are explored. Design optimization of the system required considering the combustion system efficiency and TE conversion efficiency simultaneously. The combustor performance and TE sub-system performance were coupled directly through exhaust temperatures, fuel and air mass flow rates, heat exchanger performance, subsequent hot-side temperatures, and cold-side cooling techniques and temperatures. Systematic investigation of this system relied on accurate thermodynamic modeling of complex, high-temperature combustion processes concomitantly with detailed thermoelectric converter thermal/mechanical modeling. To this end, this work reports on design integration of systemlevel process flow simulations using commercial software CHEMCADTM with in-house thermoelectric converter and module optimization, and heat exchanger analyses using COMSOLTM software. High-performance, high-temperature TE materials and segmented TE element designs are incorporated in coupled design analyses to achieve predicted TE subsystem level conversion efficiencies exceeding 10%. These TE advances are integrated with a high performance microtechnology combustion reactor based on recent advances at the Pacific Northwest National Laboratory (PNNL). Predictions from this coupled simulation established a basis for optimal selection of fuel and air flow rates, thermoelectric module design and operating conditions, and microtechnology heat-exchanger design criteria. This paper will discuss this simulation process that leads directly to system efficiency power maps defining potentially available optimal system operating conditions and regimes. This coupled simulation approach enables pathways for integrated use of high-performance combustor components, high performance TE devices, and microtechnologies to produce a compact, lightweight, combustion driven TE power system prototype that operates on common fuels.

Heat Transfer↗

Unlocking large compressive strains in thin active elastocaloric layers

Elastocaloric cooling attracts broad interest and rapidly growing attention due to its potential for high efficiency and low environmental impact. While it is common knowledge that triggering reversible entropy and temperature changes with stress applied in compression prevents rapid failures of materials, realizing this regime in elastocaloric systems is highly challenging because nearly all geometries suited for efficient heat transfer are prone to buckling even under modest loads. This work describes a concept of a novel composite, where an active NiTi layer is embedded into a polymer support structure such that the elastocaloric material is entirely in compression when the assembly is subjected to bending. The active layer achieves 8.1 K temperature change at 2.5% compressive strain without buckling. After 10,000 cycles at 2% compressive strain, the composite maintains mechanical integrity without degradation of the elastocaloric effect. The results demonstrate that NiTi and, potentially, other elastocalorically active materials in geometries previously thought impossible can be successfully implemented in regenerative cooling systems operating in compression.

42 ENGINEERING↗

Power Electronics Thermal Management R&D: Annual Report

The objective for this project is to develop thermal management strategies to enable efficient and high-temperature wide-bandgap (WBG)-based power electronic systems (e.g., emerging inverter and DC-DC converter). Device- and system-level thermal analyses are conducted to determine the thermal limitations of current automotive power modules under elevated device temperature conditions. Additionally, novel cooling concepts and material selection will be evaluated to enable high-temperature silicon and WBG devices in power electronics components. WBG devices (silicon carbide [SiC], gallium nitride [GaN]) promise to increase efficiency, but will be driven as hard as possible. This creates challenges for thermal management and reliability.

30 DIRECT ENERGY CONVERSION↗

Methods and apparatus for cooling electronics

Methods and apparatus are provided for choosing an energy-efficient coolant temperature for electronics by considering the temperature dependence of the electronics' power dissipation. This dependence is explicitly considered in selecting the coolant temperature T.sub.0 that is sent to the equipment. To minimize power consumption P.sub.Total for the entire system, where P.sub.Total=P.sub.0+P.sub.Cool is the sum of the electronic equipment's power consumption P.sub.0 plus the cooling equipment's power consumption P.sub.Cool, P.sub.Total is obtained experimentally, by measuring P.sub.0 and P.sub.Cool, as a function of three parameters: coolant temperature T.sub.0; weather-related temperature T.sub.3 that affects the performance of free-cooling equipment; and computational state C of the electronic equipment, which affects the temperature dependence of its power consumption. This experiment provides, for each possible combination of T.sub.3 and C, the value T.sub.0* of T.sub.0 that minimizes P.sub.Total. During operation, for any combination of T.sub.3 and C that occurs, the corresponding optimal coolant temperature T.sub.0* is selected, and the cooling equipment is commanded to produce it.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of heat exchanger tubes on hydrodynamics and CO 2 capture of a sorbent-based fluidized bed reactor

In virtual design and scale up of pilot-scale carbon capture systems, the coupled reactive multiphase flow problem must be solved to predict the adsorber’s performance and capture efficiency under various operation conditions. This paper focuses on the detailed computational fluid dynamics (CFD) modeling of a pilot-scale fluidized bed adsorber equipped with vertical cooling tubes. Multiphase Flow with Interphase eXchanges (MFiX), an open-source multiphase flow CFD solver, is used for the simulations with custom code to simulate the chemical reactions and filtered models to capture the effect of the unresolved details in the coarser mesh for simulations with reasonable simulations and manageable computational effort. Previously developed two filtered models for horizontal cylinder drag, heat transfer, and reaction kinetics have been modified to derive the 2D filtered models representing vertical cylinders in the coarse-grid CFD simulations. The effects of the heat exchanger configurations (i.e., horizontal or vertical) on the adsorber’s hydrodynamics and CO2 capture performance are then examined. The simulation result subsequently is compared and contrasted with another predicted by a one-dimensional three-region process model.

bubbling bed↗

Hydrogen cooling options for MgB{sub 2}-based superconducting systems

With the arrival of MgB{sub 2} for low-cost superconducting magnets, hydrogen cooling has become an interesting alternative to costly liquid helium. Hydrogen is generally regarded as the most efficient coolant in cryogenics and, in particular, is well suited for cooling superconducting magnets. Cooling methods need to take into account the specific quench propagation in the MgB{sub 2} magnet winding and facilitate a cryogenically reliable and safe cooling environment. The authors propose three different multi-coolant options for MRI scanners using helium or hydrogen within the same design framework. Furthermore, a design option for whole-body scanners which employs technology, components, fueling techniques and safety devices from the hydrogen automotive industry is presented, continuing the trend towards replacing helium with hydrogen as a safe and cost efficient coolant.

42 ENGINEERING↗

Innovative Miniaturized Heat Pumps for Buildings: Modular Thermal Hub for Building Heating, Cooling and Water Heating

BEETIT Project: Georgia Tech is using innovative components and system design to develop a new type of absorption heat pump. Georgia Tech’s new heat pumps are energy efficient, use refrigerants that do not emit greenhouse gases, and can run on energy from combustion, waste heat, or solar energy. Georgia Tech is leveraging enhancements to heat and mass transfer technology possible in microscale passages and removing hurdles to the use of heat-activated heat pumps that have existed for more than a century. Use of microscale passages allows for miniaturization of systems that can be packed as monolithic full-system packages or discrete, distributed components enabling integration into a variety of residential and commercial buildings. Compared to conventional heat pumps, Georgia Tech’s design innovations will create an absorption heat pump that is much smaller, has higher energy efficiency, and can also be mass produced at a lower cost and assembly time.

ARPA-E↗

University of Hawai‘i, Shallow Geothermal Resources: Energy Technology Innovation Partnership Project (Final Report)

Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) have teamed up with the University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology. UH requested this analysis to evaluate opportunities in building cooling, energy efficiency, and emissions reduction applications in Hawai‘i. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that, over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, so sites with large enough values of these properties must be selected. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Primarily, closed-loop systems have been investigated. Other options considered are open-loop systems and using cool seawater as the chilling source. Project work investigated the feasibility of GHE technology at two scales. At the island scale, GIS layers of various attributes relevant for GHE were combined to develop an overall favorability map for employing GHE in Hawai‘i. At the local scale, a hydrogeologic model for the subsurface component of a closed-loop system was developed for the Stan Sheriff Center at the UH Manoa campus. This site is considered promising because the rock below and immediately downgradient of the borefield is highly permeable, consisting of a subsurface karst system (limestone containing high-permeability open channels), which is underlain by a thick, high-permeability fractured basalt. Moreover, the site is near the base of the Ko‘olau Range, providing a large hydraulic head gradient. Thus, groundwater flow through the site is expected to be large, enabling efficient removal of heated groundwater. A full-GHE-system model of the site was also developed, with a simplified representation of the subsurface, in which groundwater flow is not considered and heat transfer is purely by conduction. Using the building cooling load data provided by UH, simulation results show that with groundwater flow present, a GHE can operate successfully for at least 10 years, but with no groundwater flow, the subsurface begins to heat up after only one year of operation, making the GHE unviable within 2-6 years. The team also developed a techno-economic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air-conditioning system. The GHE system is advantageous economically if favorable tax incentives and interest rates can be obtained.

15 GEOTHERMAL ENERGY↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Multi-task deep reinforcement learning for intelligent multi-zone residential HVAC control

In this short communication, a data-driven deep reinforcement learning (deep RL) method is applied to minimize HVAC users’ energy consumption costs while maintaining users’ comfort. The applied deep RL method's efficiency is enhanced by conducting multi-task learning that can achieve an economic control strategy for a multi-zone residential HVAC system in both cooling and heating scenarios. The applied multi-task deep RL method is compared with a rule-based benchmark case and a single-task deep deterministic policy gradient algorithm to verify its effective and generalized application in optimizing HVAC operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power Profile Monitoring and Tracking Evolution of System-Wide HPC Workloads

The power & energy demands of HPC machines have grown significantly. Modern exascale HPC systems require tens of megawatts of combined power for computing resources and cooling facilities at full capacity. The current energy trend is not sustainable for future HPC systems, and there is a need to work toward the energy efficiency aspect of HPC performance. Energy awareness of the HPC applications at the job level is essential for running an efficient HPC system. This work aims to develop a pipeline to provide a production-level system-wide overview of the HPC workloads' power profile while handling evolving workloads exhibiting new power trends. We developed an open-set classification model for HPC jobs based on the properties of power profiles to continuously provide a system-wide holistic view of recently completed jobs. The pipeline helps continuously monitor the job-level power usage pattern of HPC and enables us to capture the new trends in applications' power behavior. We employed a comprehensive set of techniques to generate job-level data, custom-designed feature extraction methods to extract critical features from jobs' power profiles, clustering techniques powered by generative modeling, and open-set classification for identifying job profiles into known classes or an unknown set. With extensive evaluations, we demonstrate the effectiveness of each component in our pipeline. We provide an analysis of the resulting clusters that characterize the power profile landscape of the Summit supercomputer from more than 60K jobs executed in a year. The open-set classification classifies the known data sets into known classes with high accuracy and identifies unknown data noints with over 85% accuracy.

Karimi, Ahmad Maroof↗

A Hybrid Stochastic-Interval Operation Strategy for Multi-Energy Microgrids

Increasing deployment of distributed energy resources intensifies interactions among electric, gas, heating, and cooling systems. Inherent uncertainties ranging from internal parameters to external inputs also impose significant challenges on system operation. A coordinated scheduling method is, therefore, desired for facilitating efficient operation of multi-energy microgrids under multiple uncertainties. In this paper, a deterministic coordinated scheduling model is developed first with detailed modeling of system dynamics and device parameters to fully characterize complex interactions among multi-energy carriers. Then, a hybrid stochastic-interval method is proposed to account for heterogeneous uncertainties in decisions of operational strategies. Specifically, performance and efficiency uncertainties of distributed energy resources, and injection uncertainty of renewable sources and multienergy demands are characterized by interval-based uncertain operation regions and probability distributions, respectively. A scenario-based two-stage algorithm is developed to solve the problem so that multiple uncertainties are preserved in the entire decision-making process. Moreover, adjustable operational strategies are determined to hedge uncertainty by considering operators’ risk preferences. The validity of the proposed method is verified by comprehensive case studies on a test system.

hybrid stochastic-interval approach↗

FY18Q4 Quarterly Report: Radiation Enhanced Diffusion of Ag, Ag-Pd, Eu, and Sr in Neutron Irradiated PyC/SiC Diffusion Couples

An improved understanding of the diffusion of select fission product systems in materials representative of tristructural-isotopic (TRISO) coated particle fuel are being sought to improve the safety and efficiency of high temperature gas-cooled reactors. Novel diffusion couple samples have been produced to explore diffusion under neutron irradiation and at temperatures representative of safety testing conditions. An update on the status of the neutron irradiation study and high temperature thermal testing is discussed which build upon prior reporting

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗