Search NASA⌕ Search

SEARCH · Search NASA

Results for “CyberSecurity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

The Mars 2020 Ground Data System Architecture

The Mars 2020 Mission’s primary objective is to collect 20 geographically unique samples during its prime mission of one and a quarter Martian years, or just over 2 Earth years. Mission planners determined the project needed to develop a system that would enable the operations team to analyze engineering and science data, make science decisions, select viable rover targets at a millimeter resolution and validate an uplink bundle for a car sized rover with more complex science instruments than any previous Mars surface mission. All this had to be done within a five hour time frame. Doing this with a small team would be a challenge, but this had to be accomplished by a large team of engineers and scientists located across North America and Europe. Achieving this level of operational efficiency was unheard of in the prime mission. In addition, the mission had another set of requirements that had nothing to do with surface operations; the Mars 2020 Ground Data System (GDS) was also expected to comply with a new set of security requirements to keep up with the ever changing cybersecurity landscape. The Mars 2020 Ground Data System (GDS) is a re-architected version of the Mars Science Laboratory GDS. The primary goal was to integrate the lessons learned from previous Mars surface missions, accommodate a set of new requirements and capabilities required to ensure mission success, and comply with a new set of cybersecurity controls. The new architecture includes several unique qualities including a data lake, language-agnostic system-wide event-based operations, containerization, automated deployment, network segmentation, infrastructure-as-code, API-driven interfaces, and the first Mars surface GDS to operate primarily in the cloud. The new architecture enabled greater access to the system’s data, tighter integration with the operations team, and a higher level of traceability. The availability of the data also enabled a new set of capabilities previously not possible on surface missions. These new capabilities include an autonomous data to information, pipeline for downlink analysis, horizontal scaling of science data processing capabilities, autonomous round trip data tracking of science and engineering data, integration of flight system state into the tactical planning cycle, high fidelity targeting utilizing kinematic data, and hierarchical image and 3d meshes data representations. This paper will introduce the requirements for the Mars 2020 Mission, the heritage architecture, and the rationale for the changes to achieve the new architecture. The paper will continue to describe the fundamental changes made to the GDS architecture, how these changes enabled a more tightly integrated GDS, and the new capabilities that were enabled by the new architecture. The paper will conclude with the lessons learned from the process of rearchitecting a heritage GDS system and from the first 200 days of operations supporting over 800 users from around the world.

Lopez-Roig, Reynaldo↗

Defining and Computing a Valued Based Cyber Security Measure

In earlier works (Ben-Aissa et al. 2010; Abercrombie et al. 2008; Sheldon et al. 2009), we presented a value based measure of cybersecurity that quantifies the security of a system in concrete terms, specifically, in terms of how much each system stakeholder stands to lose (in dollars per hour of operation) as a result of security threats and system vulnerabilities; our metric varies according to the stakes that each stakeholder has in meeting each security requirement. In this paper, we discuss the specification and design of a system that collects, updates, and maintains all the information that pertains to estimating our cybersecurity measure, and offers stakeholders quantitative means to make security-related decisions.

99 GENERAL AND MISCELLANEOUS↗

Social/Ethical Issues in Predictive Insider Threat Monitoring

Combining traditionally monitored cybersecurity data with other kinds of organizational data is one option for inferring the motivations of individuals, which may in turn allow early prediction and mitigation of insider threats. While unproven, some researchers believe that this combination of data may yield better results than either cybersecurity or organizational data would in isolation. However, this nontraditional approach creates a potential conflict between goals, such as conflicts between organizational security improvements and individual privacy considerations. There are many facets to debate. Should warning signs of a potential malicious insider be addressed before a malicious event has occurred to prevent harm to the organization and discourage the insider from violating the organization’s rules? Would intervention violate employee trust or legal guidelines? What about the possibilities of misuse? Predictive approaches cannot be validated a priori; false accusations can affect the career of the accused; and collection/monitoring of certain types of data may affect employee morale. In this chapter, we explore some of the social and ethical issues stemming from predictive insider threat monitoring and discuss ways that a predictive modeling approach brings to the forefront social and ethical issues that should be considered and resolved by stakeholders and communities of interest.

99 GENERAL AND MISCELLANEOUS↗

Defining and Computing a Value Based Cyber-Security Measure

In past work, we presented a value based measure of cybersecurity that quantifies the security of a system in concrete terms, specifically, in terms of how much each system stakeholder stands to lose (in dollars per hour of operation) as a result of security threats and system vulnerabilities\; our metric varies according to the stakes that each stakeholder has in meeting each security requirement. In this paper we discuss the specification and design of a system that collects, updates and maintains all the information that pertains to estimating our cybersecurity measure, and offers stakeholders quantitative means to make security-related decisions.

99 GENERAL AND MISCELLANEOUS↗

Cyberguardians Webinar

Robust solar industry growth is creating a shortage of U.S. workers who are knowledgeable in emerging Distributed Energy Resource (DER) technologies including networking, operational software, smart advanced inverters, smart advanced PV modules, and cybersecurity. Retraining military veterans and other qualified individuals to fill workforce gaps in those technologies is the project focus. The project leverages the experience and contributions of DER and cybersecurity experts, educational organizations offering accreditation, and groups serving our nation’s veterans to meet its goals. To bridge this workforce skills gap, the Cyberguardians and STEM Warriors project will establish a complete learning and career advancement system for veterans, transitioning military personnel and other qualified individuals into the DER workforce. The project will guide participants successfully through the process of program/vocation selection, curriculum enrollment, academic mentoring, degree or certificate attainment, job board enrollment, introduction to hiring managers at DER companies, and successful job acquisition. This webinar was used to promote the Cyberguardians program and to ensure ample news coverage to reach veterans, employers, and others that would benefit from this program.

14 SOLAR ENERGY↗

CyOTE ASSET OWNER ENGAGEMENT – SIDE CHANNEL POWER ANALYSIS PROTOTYPE

The U.S. Department of Energy’s (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through the Cybersecurity for the Operational Technology Environment (CyOTE) Program, worked with energy sector asset owners and operators (AOOs), partners, and Idaho National Laboratory (INL) to develop capabilities for AOOs to independently identify adversarial tactics, techniques, and procedures (TTPs) within their operational technology (OT) environments. The CyOTE methodology seeks to identify adversarial techniques within an AOO OT environment that could result in physical disruptions to energy flow or damage to equipment. CyOTE provides a general roadmap for AOOs, starting from a triggering event, or the point in time and space they perceive an anomalous event or condition meriting investigation, and culminating when the AOO has sufficient confidence to make a business risk decision on the appropriate resolution. This paper outlines the results of one such engagement with the New York Power Authority (NYPA), where the CyOTE program partnered with an AOO to develop a design specification for a power side channel detector to identify anomalous changes to device load. It describes the goal of developing this capability, the development process, the challenges the technical teams faced and the future steps an AOO will need to take to install and use this detector in its OT environment.

99 GENERAL AND MISCELLANEOUS↗

Application of HFE to the design and V and V of a computerized procedure system: benefits and challenges - 234

The application of Human Factors Engineering (HFE) practices to the Human Machine Interface design and subsequent Verification and Validation (V and V) is a widely applied practice when talking about the design of complete control rooms or important control room modernizations, but not so often applied to the design of computerized operator support systems. In order to overcome the challenges faced on designing a Computerized Operation Support System (COSS) that meets the process efficiency requirements and integrates seemingly with hybrid plant operation concept, the involvement of a HFE team early in the COSS design and implementation process along with operation, Instrumentation and Control (I and C) and cybersecurity experts will guarantee the project success. This paper documents the HFE process applied during the design and evaluation of a Computerized Procedure System (CPS) and how final product was shaped to ensure that the transition from paper to computerized procedures will help in meeting Delivering the Nuclear Promise (DNP) goals, improving plant efficiency. The HFE program included the following activities: 1. A review of existing operating experience 2. An analysis of functions and tasks associated to the use and maintenance of CPS 3. A design verification of the system to meet guidelines prescribed in the NUREG-0700 (Rev.2), requirements of the ISG-05 and cybersecurity criteria (NEI 08-09, IEC-62646, EPRI 1015313, these among others). 4. An integrated system validation in a full scope simulator The application of HFE practices in the design and implementation of COSS helps not only to ensure that efficiency and safety improvement requirements are met, but also to evaluate the potential return of the investment, that such tools should bring. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Site Integration and Regulatory Considerations for a Nuclear Power Plant Colocated with Industrial Facilities: Colocation Studies for a Petroleum Refinery, Methanol Plant, and Wood Pulp Plant

This research explores the colocation of nuclear power plants (NPPs) with industrial applications. Three existing industrial sites were considered to demonstrate the siting process and illuminate technological gaps for future work. The three applications demonstrated for colocation here are a petroleum refinery, a methanol production plant, and a pulp and paper plant. This study uses a modified version of the EPRI siting criteria to explore the geological and demographic characteristics of the location of the current industrial site, as well as exploring external hazards from the industrial plant and its surrounding land use. Data was collected from public databases to estimate site characteristics. We then discuss how the site characteristics may impact the ability to colocate an NPP with an industrial application. The application site and 5 additional sites were explored for each application to give a general indication of the siting implications for an NPP in each area. The hazards for each industrial application was also explored to determine how colocation may impact reactor safety. The following gaps have been identified and should be explored in future research on colocation of NPPs with petroleum refineries, methanol plants, and pulp and paper plants: - There is a variety of industrial use, hazards, and pipelines in the surrounding area. A more thorough review of these hazards should be considered for colocation. - In general, the whole region around some applications seems to have softer soil, with implications for large site preparation costs. Further site investigations should prioritize looking into the geotechnical conditions. - Applications along coastlines are susceptible to flooding and hurricanes. The benefits of colocation should be weighed against the potential design implications. - The benefits of natural gas pipeline infrastructure in place should be explored further. If heat supply from the NPP is not required or not feasible due to the distance between the NPP and the application, there may be an opportunity to supply hydrogen to the plant through an existing pipeline. - Because there are several collocated industrial plants in the regions for the refinery and methanol plant, the benefits of sharing resources from the NPP should be explored further. This may open up additional sites for colocation. The following knowledge gaps were identified for the colocation of NPPs with these three industries, and industrial applications in general. These gaps are: - While the STAND tool contains many important characteristics for the reactor siting process, it is not calibrated for the colocation of NPPs with industrial facilities. - There are aspects of both the NPP and industrial application that need to be quantified for a siting analysis. Particularly, we need to understand the water intake requirements for NPPs and each application. - Further work may focus on adapting the STAND site comparison methodology to comparison of sites for co-location. This will involve using the data documented in this report as a starting point and performing a comprehensive and quantitative comparison. - Without spending significant resources, it would be impossible to gather data for each site to evaluate all aspects of siting. One approach to finding data and understanding its implications to siting is looking at FSARs for existing plants. For example, most sites considered in this study have small Vs30 values, indicating soft soil. However, there are NPPs located in the vicinity of most of the sites (e.g., Waterford Steam Electric Station near New Orleans) and reviewing available site characteristics and geotechnical data for these NPPs, might provide further information for siting. - The siting analysis in this study indicates that colocation of the NPP with the industrial site could be difficult based on external hazards, cooling requirements, weather, or population. We need to determine the impact of distance between the two facilities on cost and quality of energy transport. - This study did not touch on socioeconomic impacts for NPP colocation with industrial facilities. The input-output analysis methodology could be applied to the communities referenced in this study to determine the socioeconomic impact of these projects. - Similarly, the impacts of colocation on emergency planning was not explored in this study. The impacts on emergency planning infrastructure are somewhat related to the socioeconomic impacts, and could be explored using a similar methodology. - This study also did not address physical and cybersecurity, which will be important aspects of co-location [ref] . Cybersecurity will be important, regardless of the distance, but physical security will be important if the facilities are located very closely. Physical security might also be important for the steam lines between the plants, unless they are determined to be non-safety significant. - In many site l

08 HYDROGEN↗

Reverse Engineering of Medical Devices for Innovation and Advancement in Healthcare

Medical cybersecurity research addresses the critical intersection of healthcare and digital security. As medical devices expand and become increasingly interconnected, the healthcare sector is poised to become a primary target for cyber warfare. This project aims to mitigate the risks associated with a field that often underestimates the importance of cybersecurity.

Baldwin, David↗

Employing a Hardware-in-the-Loop Approach to Realize a Fully Homomorphic Controller for a Small Modular Advanced High Temperature Reactor

This paper addresses the cybersecurity challenges of advanced nuclear reactors by integrating fully homomorphic encryption (FHE) into their control systems, enabling encrypted processing of control signals without compromising functionality. Advanced nuclear reactors, including Small Modular Reactors (SMRs) and microreactors, aim to achieve autonomous and remote operations, reducing costs and enhancing competitiveness. However, these advancements expand the attack surface for cyberattacks, particularly in autonomous and remote operation scenarios. Cyberattacks can exploit vulnerabilities to manipulate physical processes, causing shutdowns, asset damage, or public harm. Such attacks begin with passive reconnaissance, where adversaries intercept communications or observe behaviors to gather information, which is then leveraged to execute cyber-physical attacks by injecting malicious commands. Nuclear power must adopt cybersecurity protection measures to secure the integrity and availability of their digital control systems. This paper demonstrates the application of FHE to secure operations by enabling encrypted processing of sensitive signals and parameters -- ensuring privacy without exposing data. FHE supports secure mathematical operations on encrypted data without requiring decryption. Using a hardware-in-the-loop (HIL) approach, this paper implements an FHE-integrated controller on a BeagleBone Black (BBB) controlling a simulation of the Small Modular Advanced High Temperature Reactor (SmAHTR). By doing so, the encrypted controller protects the integrity of critical set points and control signals during transmission and processing. Thus, FHE-integrated controllers enhance secure operations of advanced nuclear reactors while maintaining functionality.

control systems↗

Site Integration and Regulatory Considerations for an NPP Colocated with a Petroleum Refinery, Methanol Plant, and Wood Pulp Plant

This research explores the colocation of nuclear power plants (NPPs) with industrial applications. Three existing industrial sites were considered to demonstrate the siting process and illuminate technological gaps for future work. The three applications demonstrated for colocation here are a petroleum refinery, a methanol production plant, and a pulp and paper plant. This study uses a modified version of the EPRI siting criteria to explore the geological and demographic characteristics of the location of the current industrial site, as well as exploring external hazards from the industrial plant and its surrounding land use. Data was collected from public databases to estimate site characteristics. We then discuss how the site characteristics may impact the ability to colocate an NPP with an industrial application. The application site and 5 additional sites were explored for each application to give a general indication of the siting implications for an NPP in each area. The hazards for each industrial application was also explored to determine how colocation may impact reactor safety. The following gaps have been identified and should be explored in future research on colocation of NPPs with petroleum refineries, methanol plants, and pulp and paper plants: - There is a variety of industrial use, hazards, and pipelines in the surrounding area. A more thorough review of these hazards should be considered for colocation. - In general, the whole region around some applications seems to have softer soil, with implications for large site preparation costs. Further site investigations should prioritize looking into the geotechnical conditions. - Applications along coastlines are susceptible to flooding and hurricanes. The benefits of colocation should be weighed against the potential design implications. - The benefits of natural gas pipeline infrastructure in place should be explored further. If heat supply from the NPP is not required or not feasible due to the distance between the NPP and the application, there may be an opportunity to supply hydrogen to the plant through an existing pipeline. - Because there are several collocated industrial plants in the regions for the refinery and methanol plant, the benefits of sharing resources from the NPP should be explored further. This may open up additional sites for colocation. The following knowledge gaps were identified for the colocation of NPPs with these three industries, and industrial applications in general. These gaps are: - While the STAND tool contains many important characteristics for the reactor siting process, it is not calibrated for the colocation of NPPs with industrial facilities. - There are aspects of both the NPP and industrial application that need to be quantified for a siting analysis. Particularly, we need to understand the water intake requirements for NPPs and each application. - Further work may focus on adapting the STAND site comparison methodology to comparison of sites for co-location. This will involve using the data documented in this report as a starting point and performing a comprehensive and quantitative comparison. - Without spending significant resources, it would be impossible to gather data for each site to evaluate all aspects of siting. One approach to finding data and understanding its implications to siting is looking at FSARs for existing plants. For example, most sites considered in this study have small Vs30 values, indicating soft soil. However, there are NPPs located in the vicinity of most of the sites (e.g., Waterford Steam Electric Station near New Orleans) and reviewing available site characteristics and geotechnical data for these NPPs, might provide further information for siting. - The siting analysis in this study indicates that colocation of the NPP with the industrial site could be difficult based on external hazards, cooling requirements, weather, or population. We need to determine the impact of distance between the two facilities on cost and quality of energy transport. - This study did not touch on socioeconomic impacts for NPP colocation with industrial facilities. The input-output analysis methodology could be applied to the communities referenced in this study to determine the socioeconomic impact of these projects. - Similarly, the impacts of colocation on emergency planning was not explored in this study. The impacts on emergency planning infrastructure are somewhat related to the socioeconomic impacts, and could be explored using a similar methodology. - This study also did not address physical and cybersecurity, which will be important aspects of co-location [ref] . Cybersecurity will be important, regardless of the distance, but physical security will be important if the facilities are located very closely. Physical security might also be important for the steam lines between the plants, unless they are determined to be non-safety significant. - In many site l

08 - HYDROGEN↗

Hands-On, Heads-Up: Blending Cyber T&E with Data Science-Driven Training in Jupyter Notebooks

In an era of increasingly sophisticated threats to critical infrastructure, cybersecurity professionals must be more than just aware; they must be immersed, agile, and equipped to operate in environments where failure is not an option. Nowhere is this truer than in the nuclear sector, where cyber-physical systems, regulatory scrutiny, and insider threat potential demand a new generation of hands-on, technically fluent defenders. This paper presents a unified training approach that integrates Cybersecurity Test and Evaluation (T&E) with data science techniques using Jupyter Notebooks as the interactive lab environment. The program centers on a modular, scenario-driven curriculum designed to build not just knowledge but practical capability in the assessment and defense of radiation detection systems, firmware interfaces, and operational security postures.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Proactive Intrusion Detection and Mitigation System

SAND2023-05661O The proactive intrusion detection and mitigation system (PIDMS) provides grid-edge situational awareness for cybersecurity defense by capturing real-time distributed energy resource (DER) network traffic and performance data with a novel approach that improves the detection and prevention of cyber-physical attacks. The PIDMS addresses the grid-edge security gap with real-time analysis of both network traffic and photovoltaic performance data to deliver a novel, cyber-physical intrusion detection system (IDS) approach that increases the accuracy and effectiveness of detection and mitigation. This hybrid IDS analysis enables dual monitoring that increases the workload of the adversary; both cyber and physical data would have to be simultaneously spoofed to evade detection. Furthermore, monitoring and analyzing cyber data are insufficient in some cases. For example, in an insider threat aimed at disrupting inverter grid-support functions where proper credentials and authentication are achieved, only the altered PV performance would indicate abnormal behavior. All in all, the PIDMS provides novel capabilities for: • Distributed, real-time cyber-physical detection and mitigation analysis • Cybersecurity defense for grid-edge systems • Analysis framework that can provide situational awareness across the transmission, distribution, and DER systems The PIDMS sensor is designed to collect cyber-physical data, process the data using machine-learning algorithms, detect abnormal events, and deploy mitigations. With these goals, the main functional PIDMS objectives are: • Capability to collect cyber-physical data • Onboard storage of cyber-physical data • Peer-to-peer communication • Computationally efficient machine-learning algorithms • Online cyber-physical data analysis • Alerting/visualization capabilities • Mitigation deployment capability with bump-in-the-wire (BITW) implementation Each of these functional objectives enable PIDMS to perform effective cyber-physical intrusion detection and mitigation. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Jones, Christian↗

Challenges of future high power wireless power transfer for light-duty electric vehicles----technology and risk management

Wireless power transfer is a state-of-the-art technology with the advantage of convenience and flexibility, as well as the capability of enabling fully automated charging. With power transfer levels increasing beyond 100 kW, many technical and risk management challenges emerge. Here, instead of focusing on the progress review of wireless power transfer technology, this paper discusses the future challenges and risks for high power wireless charging for light-duty electric vehicles. Aiming at 200 kW or higher wireless power transfer, we discuss technology and risk management challenges in the area of electromagnetic safety, resonant frequency determination, and cybersecurity risks in detail. As potential solutions to overcome these challenges, the latest technologies with an emphasis on advanced shielding solutions and recent progress on SiC converters from both industrial and academic institutions are reviewed, and some perspectives and propositions are provided.

25 ENERGY STORAGE↗

Towards Software Bill of Materials in the Nuclear Industry

Large, modern industrial facilities often incorporate thousands of digital assets in their operational technology. Regulated facilities, such as nuclear power plants (NPPs), maintain robust cybersecurity and configuration management programs that often use bills of materials (BOMs) for these assets, including make, model, and version of hardware, firmware, and software. However, these BOMs typically capture only first- or second-tier information provided by the original equipment manufacturer (OEM). Unfortunately, as indicated by the increasing number and sophistication of software supply chain attacks, this level of detail is insufficient for identifying all the potential vulnerabilities and risks in software applications. Software BOMs (SBOMs) provide detailed enumeration of components and dependencies within the product or devices, including firmware. SBOMs can be combined with vulnerability data sources and vendor vulnerability attestations to improve vulnerability management and enable rapid identification of affected components when new software vulnerabilities are discovered. Ideally, SBOMs are created by the OEM prior to installation. However, since this practice is not yet commonplace and since NPPs are typically slow to adopt new technology, most NPPs do not incorporate SBOMs into their asset or configuration management programs. Fortunately, SBOMs can be generated by NPPs on existing digital assets to provide further insight into risk management decisions. This report provides an overview of the current SBOM ecosystem and recommends guidance on how to get started in a “crawl, walk, run” manner to develop and implement a sustainable SBOM program for digital assets in an NPP.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Washington State Cyber Incident Response Summit Event Report

On September 7 and 8, 2022, Pacific Northwest National Laboratory and Washington State Adjutant General Major General Bret Daugherty, with support from the Department of Homeland Security Cybersecurity and Infrastructure Security Agency, hosted the Washington State Cyber Incident Response Summit at Camp Murray in Washington State. The invite-only summit convened 40 key decision makers and stakeholders from across the state to discuss strategies and pilot a collaborative approach to improve cyber incident response readiness within Washington. In small working groups, participants shared incident response lessons learned, best practices, and opportunities for improvement within the water and transportation sectors. This report highlights the details of the workshop presentations and discussions.

97 MATHEMATICS AND COMPUTING↗

The Distributed Energy Resource Risk Manager

Organizations need a comprehensive approach to managing security and privacy risks, especially for energy resources that are becoming increasingly distributed. A tool by the National Renewable Energy Laboratory (NREL) makes it possible to manage these risks and maintain the highest standards of cybersecurity. To simplify risk management for facilities and distributed energy resources, NREL has created the Distributed Energy Resource Risk Manager, an automated, user-friendly tool that helps navigate and implement one of the most widely trusted frameworks for information security, the National Institute of Standards and Technology Risk Management Framework.

compliance↗

A National Secure-by-Design Strategy

The US National Cybersecurity Strategy published March 2, 2023 uses plain language to communicate that the US is calling for a major change in how we prioritize the security of software systems used in critical infrastructure. It acknowledges that our current approach, which is essentially, “let the buyer beware,” leaves entities who are least able to assess or defend vulnerable software responsible for the impacts of designed-in weaknesses while the makers of the technology bear no liability. The strategy recommends a security-by-design approach, recommending that software vendors be held liable to uphold a “duty of care” to consumers and for systems to be designed to “fail safely and recover quickly” . For energy infrastructure, the strategy calls out the need to implement the National Cyber-Informed Engineering Strategy to achieve higher confidence security for energy infrastructures. The Idaho National Laboratory, a pioneer in cyber-informed engineering concepts, is at the forefront of organizations educating others in industry, academia, and government on how to apply these concepts to real-world challenges. In this brief, we'll outline some of the basic principles of security-by-design and offer examples of how, in a water sector context, they're being put into successful practice.

42 ENGINEERING↗