Corrective Action Management Unit Report of Post-Closure Care Activities Calendar Year 2017.

The Corrective Action Management Unit (CAMU) at Sandia National Laboratories, New Mexico (SNL/NM) consists of a containment cell and ancillary systems that underwent regulatory closure in 2003 in accordance with the Closure Plan in Appendix D of the Class 3 Permit Modification (SNL/NM September 1997). The containment cell was closed with wastes in place. On January 27, 2015, the New Mexico Environment Department (NMED) issued the Hazardous Waste Facility Operating Permit (Permit) for Sandia National Laboratories (NMED January 2015). The Permit became effective February 26, 2015. The CAMU is undergoing post-closure care in accordance with the Permit, as revised and updated. This CAMU Report of Post-Closure Care Activities documents all activities and results for Calendar Year (CY) 2017 as required by the Permit. The CAMU containment cell consists of engineered barriers including a cover system, a bottom liner with a leachate collection and removal system (LCRS), and a vadose zone monitoring system (VZMS). The VZMS provides information on soil conditions under the cell for early leak detection. The VZMS consists of three monitoring subsystems, which include the primary subliner (PSL), a vertical sensor array (VSA), and the Chemical Waste Landfill (CWL) sanitary sewer (CSS) line. The PSL, VSA, and CSS monitoring subsystems are monitored quarterly for soil moisture concentration, the VSA is monitored quarterly for soil temperature, and the VSA and CSS monitoring subsystems are monitored annually for volatile organic compound (VOC) concentrations in the soil vapor at various depths. Baseline data for the soil moisture, soil temperature, and soil vapor were established between October 2003 and September 2004.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Passive microwave remote and in situ measurements of Arctic and subarctic snow covers in Alaska

Airborne and satellite passive microwave measurements acquired simultaneously with ground measurements of depth, density, and stratigraphy of the snow in central and northern Alaska between March 11 and 19, 1988, are reported. A good correspondence in brightness temperature (TB) trends between the aircraft and satellite data was found. An expected inverse correlation between depth hoar thickness and TB was not found to be strong. A persistent TB minimum in both the aircraft and the satellite data was detected along the northern foothills of the Brooks Range. In an area located at about 68 deg 60 min N, 149 deg 20 min W, the TB as recorded from the aircraft microwave sensor dropped by 55 K. Satellite microwave measurements showed a TB decrease of up to 45 K at approximately the same location. An examination of microwave satellite data from 1978 to 1987 revealed that similar low late-winter values were found in approximately the same locations as those observed in March 1988.

Hall, D. K.↗

Retrieval of Ozone Column Content from Airborne Sun Photometer Measurements During SOLVE II: Comparison with SAGE III, POAM III,THOMAS and GOME Measurements

During the Second SAGE 111 Ozone Loss and Validation Experiment (SOLVE II), the 14- channel NASA Ames Airborne Trackmg Sunphotometer (AATS-14) was mounted on the NASA DC-8 and successfully measured spectra of total and aerosol optical depth (TOD and AOD) during the sunlit portions of eight science flights. Values of ozone column content above the aircraft have been derived from the AATS-14 data by using a linear least squares method. For each AATS-14 measured TOD spectrum, this method iteratively finds the ozone column content that yields the best match between measured and calculated TOD. The calculations assume the known Chappuis ozone band shape and a three-parameter AOD shape (quadratic in log-log space). Seven of the AATS-14 channels (each employing an interference filter with a nominal full-width at half maximum bandpass of -5 nm) are within the Chappuis band, with center wavelengths between 452.9 nm and 864.5 nm. One channel (604.4 nm) is near the peak, and three channels (499.4, 519.4 and 675.1 nm) have ozone absorption within 30-40% of that at the peak. For the typical DC-8 SOLVE II cruising altitudes of approx. 8-12 km and the background stratospheric aerosol conditions that prevailed during SOLVE 11, absorption of incoming solar radiation by ozone comprised a significant fraction of the aerosol-plus-ozone optical depth measured in the four AATS-14 channels centered between 499.4 and 675.1 nm. Typical AODs above the DC-8 ranged from 0.003-0.008 in these channels. For comparison, an ozone overburden of 0.3 atm-cm (300 DU) translates to ozone optical depths of 0.009,0.014, 0.041, and 0.012, respectively, at these same wavelengths. In this paper, we compare AATS-14 values of ozone column content with temporally and spatially near-coincident values derived from measurements acquired by the Stratospheric Aerosol and Gas Experiment III (SAGE III) and the Polar Ozone and Aerosol Measurement 111 (POAM III) satellite sensors. We also compare AATS-14 ozone retrievals during selected DC-8 latitudinal and longitudinal transects with total column ozone data acquired by the Total Ozone Mapping Spectrometer (TOMS) and the Global Ozone Monitoring Experiment (GOME) satellite sensors. To enable this comparison, the amount of ozone in the column below the aircraft is estimated by combining SAGE and/or POAM data with high resolution, fast response in-situ ozone measurements acquired during the DC-8 ascent at the start of each science flight.

Livingston, J.↗

Small Gas Bubble Experiment for Mitigation of Cavitation Damage and Pressure Waves in Short-pulse Mercury Spallation Targets

Populations of small helium gas bubbles were introduced into a flowing mercury experiment test loop to evaluate mitigation of beam-pulse induced cavitation damage and pressure waves. The test loop was developed and thoroughly tested at the Spallation Neutron Source (SNS) prior to irradiations at the Los Alamos Neutron Science Center - Weapons Neutron Research Center (LANSCE-WNR) facility. Twelve candidate bubblers were evaluated over a range of mercury flow and gas injection rates by use of a novel optical measurement technique that accurately assessed the generated bubble size distributions. Final selection for irradiation testing included two variations of a swirl bubbler provided by Japan Proton Accelerator Research Complex (J-PARC) collaborators and one orifice bubbler developed at SNS. Bubble populations of interest consisted of sizes up to 150 m in radius with achieved gas void fractions in the 10^-5 to 10^-4 range. The nominal WNR beam pulse used for the experiment created energy deposition in the mercury comparable to SNS pulses operating at 2.5 MW. Nineteen test conditions were completed each with 100 pulses, including variations on mercury flow, gas injection and protons per pulse. The principal measure of cavitation damage mitigation was surface damage assessment on test specimens that were manually replaced for each test condition. Damage assessment was done after radiation decay and decontamination by optical and laser profiling microscopy with damaged area fraction and maximum pit depth being the more valued results. Damage was reduced by flow alone; the best mitigation from bubble injection was between half and a quarter that of flow alone. Other data collected included surface motion tracking by three laser Doppler vibrometers (LDV), loop wall dynamic strain, beam diagnostics for charge and beam profile assessment, embedded hydrophones and pressure sensors, and sound measurement by a suite of conventional and contact microphones.

bubbles↗

New River Geothermal Exploration (Ram Power Inc.)

The New River Geothermal Exploration (DOE Award No. EE0002843) is located approximately 25km south of the Salton Sea, near town of Brawley in Imperial County and approximately 150km east of San Diego, California. A total of 182 MT Logger sites were completed covering the two separate Mesquite and New River grids. The data was collected over a frequency range of 320Hz to 0.001Hz with variable site spacing. A number of different inversion algorithms in 1D, 2D and 3D were used to produce resistivity-depth profiles and maps of subsurface resistivity variations over the survey area. For 2D inversions, a total of eighteen lines were constructed in east-west and north-south orientations crossing the entire survey area. For MT 3D inversion, the New River property was divided in two sub-grids, Mesquite and New River areas. The report comprises of two parts. For the first part, inversions and geophysical interpretation results are presented with some recommendations of the potential targets for future follow up on the property. The second part of the report describes logistics of the survey, survey parameters, methodology and the survey results (data) in digital documents. The report reviews a Spartan MT survey carried out by Quantec Geoscience Limited over the New River Project in California, USA on behalf of Ram Power Inc. Data was acquired over a period of 29 days from 2010/06/26 to 2010/07/24.

15 GEOTHERMAL ENERGY↗

Remote-sensing detectability of airborne Arctic dust

Remote-sensing (RS)-based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on questionable claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness temperature differences at 11 and 12 µm (BTD 11–12 ), has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD 11–12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One much more likely contributor would be water clouds in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD 11–12 values would, however, only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced ice-nucleating particle (INP) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can readily be detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate-sensitive region.

54 ENVIRONMENTAL SCIENCES↗

SAM 2 measurements of the polar stratospheric aerosol. Volume 4: April 1980 to October 1980

The Stratospheric Aerosol Measurement (SAM) 2 sensor is aboard the Nimbus 7 spacecraft providing extinction measurements of the Antarctic and Arctic stratospheric aerosols with a vertical resolution of 1 km. Representative examples and weekly averages of these aerosol data and corresponding temperature profiles are presented. Contours of aerosols extinction as a function of altitude and longitude or time are plotted and weekly aerosol optical depths are calculated. Stratospheric optical depths are 0.002 to 0.003 for the Antarctic and 0.002 to 0.003 at the beginning to 0.005 to 0.006 at the end of the time period for the Arctic. Polar stratospheric clouds at altitudes between the tropopause and 20 km were observed during the Antarctic winter. A ready-to-use format containing a representative sample of the fourth 6 months of data to be used in atmospheric and climatic studies is reported.

Mccormick, M. P.↗

Summary of results and conclusions based on analysis of volume imaging and high spectral resolution lidar data acquired during FIRE phase 1, part 1

The collection of long term global statistics on cloud cover may be most easily accomplished with satellite based observations; however, measurements derived from passive satellite retrieval methods must be calibrated and verified by in situ or ground based remote sensor observations. Verification is not straight forward, however, because the highly variable nature of cloud altitude, morphology, and optical characteristics complicates the scaling of point measurements to satellite footprint sized areas. This is particularly evident for cirrus clouds which may be organized on horizontal scales of 10's of meters to 8 km or more, and have optical depths ranging from less than .003 to greater than 3. Cirrus clouds can strongly influence earths' radiative balance, but, because they are often transmissive, cirrus clouds are difficult to detect and characterize from satellite measurements. Because of its precise ranging capabilities, spatial resolution and sensitivity, lidar observations have played an important role in the detection, depiction, and characterization of cirrus clouds. Some of the characteristics of cirrus clouds are summarized which observed the High Spectral Resolution and Volume Imaging Lidars during the phase 1 IFO and ETO periods.

Grund, Christian J.↗

Application of Fault Management Theory to the Quantitative Selection of a Launch Vehicle Abort Trigger Suite

The theory of System Health Management (SHM) and of its operational subset Fault Management (FM) states that FM is implemented as a "meta" control loop, known as an FM Control Loop (FMCL). The FMCL detects that all or part of a system is now failed, or in the future will fail (that is, cannot be controlled within acceptable limits to achieve its objectives), and takes a control action (a response) to return the system to a controllable state. In terms of control theory, the effectiveness of each FMCL is estimated based on its ability to correctly estimate the system state, and on the speed of its response to the current or impending failure effects. This paper describes how this theory has been successfully applied on the National Aeronautics and Space Administration's (NASA) Space Launch System (SLS) Program to quantitatively estimate the effectiveness of proposed abort triggers so as to select the most effective suite to protect the astronauts from catastrophic failure of the SLS. The premise behind this process is to be able to quantitatively provide the value versus risk trade‐off for any given abort trigger, allowing decision makers to make more informed decisions. All current and planned crewed launch vehicles have some form of vehicle health management system integrated with an emergency launch abort system to ensure crew safety. While the design can vary, the underlying principle is the same: detect imminent catastrophic vehicle failure, initiate launch abort, and extract the crew to safety. Abort triggers are the detection mechanisms that identify that a catastrophic launch vehicle failure is occurring or is imminent and cause the initiation of a notification to the crew vehicle that the escape system must be activated. While ensuring that the abort triggers provide this function, designers must also ensure that the abort triggers do not signal that a catastrophic failure is imminent when in fact the launch vehicle can successfully achieve orbit. That is, the abort triggers must have low false negative rates to be sure that real crew‐threatening failures are detected, and also low false positive rates to ensure that the crew does not abort from non‐crew‐threatening launch vehicle behaviors. The analysis process described in this paper is a compilation of over six years of lessons learned and refinements from experiences developing abort triggers for NASA's Constellation Program (Ares I Project) and the SLS Program, as well as the simultaneous development of SHM/FM theory. The paper will describe the abort analysis concepts and process, developed in conjunction with SLS Safety and Mission Assurance (S&MA) to define a common set of mission phase, failure scenario, and Loss of Mission Environment (LOME) combinations upon which the SLS Loss of Mission (LOM) Probabilistic Risk Assessment (PRA) models are built. This abort analysis also requires strong coordination with the Multi‐Purpose Crew Vehicle (MPCV) and SLS Structures and Environments (STE) to formulate a series of abortability tables that encapsulate explosion dynamics over the ascent mission phase. The design and assessment of abort conditions and triggers to estimate their Loss of Crew (LOC) Benefits also requires in‐depth integration with other groups, including Avionics, Guidance, Navigation and Control(GN&C), the Crew Office, Mission Operations, and Ground Systems. The outputs of this analysis are a critical input to SLS S&MA's LOC PRA models. The process described here may well be the first full quantitative application of SHM/FM theory to the selection of a sensor suite for any aerospace system.

Lo, Yunnhon↗

A Monolithic 2k x 2k LWIR HgCdTe Detector Array for Passively Cooled Space Missions

A 2K x 2K 10 µm cutoff HgCdTe array for background-limited space astronomy has been developed by Teledyne Imaging Sensors to specifications set by JPL, and demonstrated by University of Rochester at a focal plane temperature of 40K for the proposed JPL Near-Earth Object Camera (NEOCam) survey mission under the NASA Planetary Defense Coordination Office. We describe the detector performance for the first large format monolithic HgCdTe detector array tested, including the dark current, well depth, dark current vs. temperature, quantum efficiency, latent image performance, and read noise.

Pan, Jianmei↗

A Monolithic 2k x 2k LWIR HgCdTe Detector Array for Passively Cooled Space Missions

A 2K x 2K 10 µm cutoff HgCdTe array for background-limited space astronomy has been developed by Teledyne Imaging Sensors to specifications set by JPL, and demonstrated by University of Rochester at a focal plane temperature of 40K for the proposed JPL Near-Earth Object Camera (NEOCam) survey mission under the NASA Planetary Defense Coordination Office. We describe the detector performance for the first large format monolithic HgCdTe detector array tested, including the dark current, well depth, dark current vs. temperature, quantum efficiency, latent image performance, and read noise.

Pan, Jianmei↗

Overview of NASA's Detailed Investigation into the MEDLI2 Flight Data

- MEDLI2 “Deep Dive” - Why a focused investigation? - Deeper understanding of the MEDLI2 dataset, including TPS in-depth temperatures, backshell pressure, and radiative heat flux - Validate new tools for future Mars missions including Mars Sample Return and Humans-to-Mars - MEDLI2 is considerably more complex than MEDLI - Fully leverage the significant investment in the MEDLI2 instrumentation suite - Core research areas: - PICA-NuSil (PICA-N) testing, model development, and validation - Detailed aeroheating investigations - Sensor fusion of collocated measurements - High-fidelity analyses and uncertainty quantification - Trajectory and aerodynamics investigations

Tom West↗

Deep Learning Models Augment Analyst Decisions for Event Discrimination

Long-term seismic monitoring networks are well positioned to leverage advances in machine learning because of the abundance of labeled training data that curated event catalogs provide. In this study, we explore the use of Convolutional and Recurrent Neural Networks to accomplish discrimination of explosive and tectonic sources for local distances. Using a 5-year event catalog generated by the University of Utah Seismograph Stations we train models to produce automated event labels using 90 s event spectrograms from 3-component and single-channel sensors. Both network architectures are able to replicate analyst labels above 98%. Most commonly, model error is the result of label error (70% of cases). Accounting for mislabeled events (~1% of the catalog) model accuracy for both models increases to above 99%. Finally, classification accuracy remains above 98% for shallow tectonic events, indicating that spectral characteristics controlled by event depth do not play a dominant role in event discrimination.

58 GEOSCIENCES↗

Mixed Layer Drift Revealed by Satellite Data

For the first time we are able to derive ocean currents using the wavelet algorithm for feature tracking from two different sensors (MODIS and SeaWiFS) on different satellites. Satellite ocean color data provide an important insight to the marine biosphere because of their capability to quantify certain fundamental properties (such as phytoplankton pigment concentration, marine primary production, etc.) on a global basis. The mixed layer drift can be derived because the ocean color signal bears information from a much larger depth (10 to 30 meters) as compared with the sea surface temperature data. Although the drifter data are very limited in the study area, the comparison shows a general agreement between drifter data and satellite tracking results, especially for the cases near the Gulf Stream boundary.

Liu, Antony K.↗

Ozone Observations by the Gas and Aerosol Measurement Sensor during SOLVE II

The Gas and Aerosol Measurement Sensor (GAMS) was deployed aboard the NASA DC-8 aircraft during the second SAGE III Ozone Loss and Validation Experiment (SOLVE II). GAMS acquired line-of-sight (LOS) direct solar irradiance spectra during the sunlit portions of ten science flights of the DC-8 between 12 January and 4 February 2003. Differential line-of-sight (DLOS) optical depth spectra are produced from the GAMS raw solar irradiance spectra. Then, DLOS ozone number densities are retrieved from the GAMS spectra using a multiple linear regression spectral fitting technique. Both the DLOS optical depth spectra and retrieved ozone data are compared with coincident measurements from two other solar instruments aboard the DC-8 platform to demonstrate the robustness and stability of the GAMS data. The GAMS ozone measurements are then utilized to evaluate the quality of the Wulf band ozone cross sections, a critical component of the SAGE III aerosol, water vapor, and temperature/pressure retrievals. Results suggest the ozone cross section compilation of Shettle and Anderson currently used operationally in SAGE III data processing may be in error by as much as 10-20% in theWulf bands, and their lack of reported temperature dependence is a significant deficiency. A second, more recent, cross section database compiled for the SCIAMACHY satellite mission appears to be of much better quality in the Wulf bands, but still may have errors as large as 5% near the Wulf band absorption peaks, which is slightly larger than their stated uncertainty. Additional laboratory measurements of the Wulf band cross sections should be pursued to further reduce their uncertainty and better quantify their temperature dependence.

Pitts, M. C.↗

Absorption in Extended Inhomogeneous Clouds

The launch of several different sensors, including CloudSat, into the A-train constellation of satellites allows us for the first time to compute absorption that can occur in realistic vertically inhomogeneous clouds including multiple cloud decks. CloudSat data show that these situations are common. Therefore, understanding vertically inhomogeneous clouds is important from both climate and satellite atmospheric composition remote sensing perspectives. Satellite passive sensors that operate from the near IR to the UV often rely on radiative cloud pressures derived from absorption in oxygen bands (A, B, gamma, or O2-O2 bands) or from rotational-Raman scattering in order to retrieve information about atmospheric trace gases. The radiative cloud pressure is distinct from the physical cloud top derived from thermal infrared measurements. Therefore, the combination of information from different passive sensors yields some information about the cloud vertical profile. When either or both the clouds or atmospheric absorbers (trace gases and aerosols) are vertically inhomogeneous, the use of an effective cloud pressure derived from these approaches may lead to errors. Here, we focus on several scenarios (deep convective clouds and distinct two layer clouds) based on realistic cloud optical depth vertical profiles derived from the CloudSatfMODIS combination. We focus on implications for trace-gas column amount retrievals (specifically ozone and NO2) and derived surface UV irradiance from the Ozone Monitoring Instrument (OMI) on the Atrain Aura platform.

Joiner, Joanna↗

Development and Testing of a Friction-Based Post-Installable Fiber-Optic Monitoring System for Subsea Applications

This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system capable of measuring pressure, strain, and temperature that can be deployed on existing subsea structures. A summary is provided of the design concept, prototype development, prototype performance testing, and subsequent design refinements of the device. The results of laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are also included. Limitations of the initial concept were identified during testing and future design improvements were proposed and later implemented. These new features enhance the coupling of the sensor device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on flowlines, risers, and other subsea structures. The work described in this paper investigates the design and test of a friction-based coupling device (herein referred to as a friction clamp) which is suitable for pipelines and structures that are suspended in the water column as well as for those that are resting on the seabed. The monitoring elements consist of fiberoptic sensors that are bonded to a stainless steel clamshell assembly with a high-friction surface coating. The friction clamp incorporates a single hinge design to facilitate installation of the clamp and dual rows of opposing fasteners to distribute the clamping force along the structure. The friction clamp can be modified to be installed by commercial divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance technologies that will benefit the environment, the public, and commercial industries.

Bentley, Nicole L.↗

Investigation of source-detector separation optimization for an implantable perfusion and oxygenation sensor for liver blood vessels

An implanted system is being developed to monitor transplanted liver health during the critical 7-10 day period posttransplantation. The unit will monitor organ perfusion and oxygen consumption using optically-based probes placed on both the inflow and outflow blood vessels, and on the liver parenchymal surface. Sensing probes are based on a 3- wavelength LED source and a photodiode detector. Sample diffuse reflectance is measured at 735, 805, and 940 nm. To ascertain optimal source-to-photodetector spacing for perfusion measurement in blood vessels, an ex vivo study was conducted. In this work, a dye mixture simulating 80% blood oxygen saturation was developed and perfused through excised porcine arteries while collecting data for various preset probe source-to-photodetector spacings. The results from this study demonstrate a decrease in the optical signal with decreasing LED drive current and a reduction in perfusion index signal with increasing probe spacing. They also reveal a 2- to 4-mm optimal range for blood vessel perfusion probe source-to-photodetector spacing that allows for sufficient perfusion signal modulation depth with maximized signal to noise ratio (SNR). These findings are currently being applied to guide electronic configuration and probe placement for in vivo liver perfusion porcine model studies.