Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Analytical study of electrical disconnect system for use on manned and unmanned missions

The program to survey existing electrical connector availability, and establish an optimum connector design for maintainable spacecraft substation interfaces is reported. Functional and operational requirements are given along with the results of the documentation survey, which disclosed that the MSFC series connectors have the preferred features of current connector technology. Optimum design concepts for EVA tasks, modules serviced by manipulators, and for manipulators independent of other servicing units are presented. It is concluded that separate connector designs are required for spacecraft replaceable modules, and for crewman EVA.

Rosener, A. A.↗

Renewable Energy and Efficiency Technologies in Scenarios of U.S. Decarbonization in Two Types of Models: Comparison of GCAM Modeling and Sector-Specific Modeling

Energy system projections from quantitative models inform actions ranging from short-term and local decisions, such as those about technology and infrastructure deployment, and global and long-term negotiations and targets. Computational limits require model designers to balance coverage and resolution (i.e., breadth versus depth). Some models, such as the Global Change Analysis Model (GCAM), represent all energy sources and uses with less resolution than models that focus on a single sector's energy use. GCAM balances global supply and demand of all energy carriers projecting prices using internal calculations for energy sources and costs of greenhouse gas mitigation while capturing interlinkages between the energy system, water, agriculture and land use, the economy, and the climate. This globally comprehensive model was used to frame the Long-Term Strategy of the United States: Pathways to Net-Zero Greenhouse Gas Emissions by 2050, which the White House released in 2021 and has been used to inform national and global economy-wide climate change mitigation discussions and strategy development for decades. Unlike GCAM, sectoral models focus on a portion of the energy sector and with greater detail and resolution. The Regional Energy Deployment System (ReEDS) electricity-sector model, for example, projects electricity system capacity expansion and operation with high-fidelity representation of emerging technologies for deep decarbonization, such as variable renewable energy and energy storage, and integration of these technologies into the electric grid. The Transportation Energy and Mobility Pathway Options (TEMPO) transportation-sector model enables analysis of household choices, with a focus on adoption, charging, and use of electric vehicles. The Scout buildings-sector model supports detailed consideration of the policies and markets that can accelerate the adoption of electrification and energy conservation measures in buildings. Such sector-specific models are instrumental in informing technology research, sectoral planning strategies, and sector-specific aspects of greenhouse gas mitigation strategies in the United States. The integrated multisector and sector-specific modeling approaches represented by GCAM and these sectoral models are complementary. The integrated multisector approach calculates energy pricing and resource allocation within the model, which is important for consistency when future conditions substantially diverge from current conditions in transformative scenarios. The sector-specific approach facilitates representation of granular details across spatial, temporal, technological, and market dimensions that enable exploration of particular interactions and trade-offs. This report presents the results of recent work to explore the differences and trade-offs between these approaches by comparing GCAM with the sector-specific ReEDS, TEMPO, and Scout models. The report compares both model structures and results, and it addresses their potential relevance and applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ACONF DOS

ACONF is a system which has been developed by Sandia National Laboratories. ACONF is a system for optimizing the interaction between generator, photovoltaic system, batteries, and load in independent non-grid-tied electrical systems. It is primarily used in rural locations where running utility lines proves costly if it is possible at all. It is controlled by an Ampro PC-104 Coremodule 400 controller system. The code for this system is written in the BASIC programming language. The routine contained in this document was written originally by Phil Symons. ACONF is intended to increase the efficiency of freestanding electrical systems to increase battery life and more efficiently use generator fuel.

Atcitty, Stanley↗

300-kW Solar Electric Propulsion System Configuration for Human Exploration of Near-Earth Asteroids

The use of Solar Electric Propulsion (SEP) can provide significant benefits for the human exploration of near-Earth asteroids. These benefits include substantial cost savings - represented by a significant reduction in the mass required to be lifted to low Earth orbit - and increased mission flexibility. To achieve these benefits, system power levels of 100's of kW are necessary along with the capability to store and process tens of thousands of kilograms of xenon propellant. The paper presents a conceptual design of a 300-kW SEP vehicle, with the capability to store nearly 40,000 kg of xenon, to support human missions to near-Earth asteroids.

high-power↗

Time-Sensitive Value of Efficiency: Use Cases in Electricity Sector Planning and Programs

Most energy efficiency measures produce energy savings that vary over the course of a year. The value of the hourly electricity savings also varies over the course of a year because the cost of generating, transmitting and distributing electricity during peak demand periods may be significantly higher than during off-peak, or lower load, hours. But many planning and program activities across the United States are missing this important element. A variety of trends are changing the electricity system, including increased adoption of other distributed energy resources, electrification of buildings and vehicles, and relative costs for natural gas-fired and renewable energy generation. Knowing when energy efficiency occurs and the value of the energy or demand savings to the electricity system—the time-sensitive value of efficiency—provides public utility commissions, utilities and other decision makers with key information needed to procure the optimal amount of energy efficiency for their system. The report begins with a discussion of our approach to determining use cases and examples, and then examines the need for time-sensitive efficiency data. Next, it examines five use cases in which states, independent system operators/regional transmission operators (ISOs/RTOs), utilities, and efficiency program administrators consider the TSV-EE: (1) energy efficiency program planning and evaluation, (2) distribution system planning, (3) electricity resource planning (4) electricity rate design, and (5) state and local government activities. The report concludes with areas for future research on the time-sensitive value of efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Motor/Generator and Inverter Characterization for Flywheel System Applications

The Advanced Electrical Systems Development Branch at NASA Glenn Research Center (GRC) has been involved in the research and development of high speed flywheels systems for satellite energy storage and attitude applications. These flywheels will serve as replacement for chemical nickel hydrogen, nickel cadmium batteries and gyroscopic wheels. The advantages of using flywheel systems for energy storage on satellites are high energy density, high power density, long life, deep depth of discharge, and broad operating temperature ranges. A flywheel system for space applications consist of a number of flywheel modules, the motor/generator and magnetic bearing, and an electronics package. The motor/generator electronics package includes a pulse-width modulated inverter that drives the flywheel permanent magnet motor/generator located at one end of the shaft. This summer, I worked under the direct supervision of my mentor, Walter Santiago, and the goal for this summer was to characterize motor generator and inverter attributes in order to increase their viability as a more efficient energy storage source for space applications. To achieve this goal, magnetic field measurements around the motor/generator permanent magnet and the impedance of the motor/generator three phase windings were characterized, and a recreation of the inverter pulse width modulated control system was constructed. The Flywheel modules for space use are designed to maximize energy density and minimize loss, and attaining these values will aid in locating and reducing losses within the flywheel system as a whole, making flywheel technology more attractive for use as energy storage in future space applications.

Tamarcus, Jeffries L.↗

Design and performance of an arcjet nuclear electric propulsion system for a mid-1990's reference mission

The design and performance of an arcjet nuclear-electric-propulsion spacecraft, suitable for use in the Space Nuclear Power System (SNPS) reference mission, are outlined. The vehicle design was based on a 30-kW ammonia arcjet system operating at an Isp of 1050 s and an efficiency of 45 percent. The arcjet/gimbal system, power-processing unit, and propellant-feed system are described. A 100-kWe SNPS was assumed, and the spacecraft mass was baselined at 5250 kg (excluding the propellant-feed system). A radiation/arcjet efflux diagnostics package was included in the performance analysis. This spacecraft, assuming a Shuttle launch from KSC, can perform a 50-deg inclination change and reach a final orbit of 35,860 km with a 120-d trip time providing a 4-mo active load for the SNPS. Alternatively, a Titan IV launch would provide a mass margin of 120 kg to a 10,000-km, 58-deg final orbit in 74 d. This spacecraft meets the reference-mission constraint of low developmental risk, and is scalable to power levels projected for future space platforms.

Deininger, William D.↗

Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System

Circuit-level metering technologies provide the ability to monitor individual circuits within an electrical panel in a building, providing detailed power and energy consumption data at a much more granular level than was previously achievable in a cost-effective manner. While the fundamental hardware components of circuit-level—split-core current transformers (CTs) and power monitoring meters—have existed for some time, the new offerings in the market have tightly integrated these components, lower costs, and have streamlined data organization, transport, and access via software solutions accessible through web and application programming interfaces (API). NREL evaluated Meazon’s single-circuit metering system. The evaluation of the equipment under test (EUT) focused on three aspects: (1) accuracy of the data provided by the system, (2) ease of installation of this technology and ease of data integration into existing U.S. General Services Administration (GSA) analytics platforms, and (3) total cost of ownership and cost-effectiveness of the technology. The metering technology was tested in a field deployment where it was installed in low and high-voltage commercial electrical panels in the César E. Chávez Memorial Building in Denver, Colorado. The goals were to assess the metering accuracy, the ease of installation and data retrieval, and the total cost of ownership and cost-effectiveness. This technology proved easy to install by a certified electrician who completed the install of 6 meters in 2 separate panels (120/208 V and 277/480 V) and 2 circuit disconnects (along with associated commissioning) at the César E. Chávez Memorial Building in less than one day. The technology was installed in high- and low-voltage panels and with limited space in the electrical room, demonstrating the applicability of this technology to almost all commercial buildings in the GSA portfolio. Primary considerations for this technology include appropriate sizing of CTs for each circuit, selection of loads/circuits/panels that are of high value for detailed submetering (e.g., tailored for high-load devices), and how GSA would like to integrate these data with its existing energy management infrastructure. Through the field evaluation, we demonstrated data integration from the vendor system into the primary software component on the GSA enterprise-level energy management and information system, GSA Link. Data from the circuit-level metering were integrated into this platform and used to perform FDD. This demonstrated the ability of the EUT to augment existing energy management and information systems in buildings where GSA Link is deployed and provides a pathway for delivering FDD at other buildings throughout the portfolio.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Heavy-Duty Truck Electrification and the Impacts of Depot Charging on Electricity Distribution Systems

Major technological advancements and recent policy support are improving the outlook for heavy-duty truck electrification in the United States. In particular, short-haul operations (=200 miles (=322 km)) are prevalent and early candidates for plug-in electric vehicles (EVs) given their short, predictable routes and return-to-base applications, which allows vehicles to recharge when off shift at their depots. Although previous studies investigated the impacts of added electrical loads on distribution systems, which included light-duty EVs, the implications for heavy-duty EV charging are underexplored. Here we summarize the causes, costs and lead times of distribution system upgrades anticipated for depot charging. We also developed synthetic depot charging load profiles for heavy-duty trucks from real-world operating schedules, and found that charging requirements are met at common light-duty EV charging rates (=100 kW per vehicle). Finally, we applied depot charging load profiles to 36 distribution real-world substations, which showed that most can accommodate high levels of heavy-duty EV charging without upgrades.

47 OTHER INSTRUMENTATION↗

Solar and Wind Forecast Error Reserve Sharing in a Multi-Utility Region

As electricity systems transition to higher levels of solar and wind generation, electric system operators will likely need to hold additional reserves to manage the forecast error associated with these resources. Because wind and solar forecast errors tend to be poorly correlated across space, system operators can reduce their reserve requirements by sharing reserves. This paper examines the value of forecast error reserve sharing among balancing areas in the Southeast United States. It finds that forecast error reserve requirements increase linearly with growth in solar and wind generation capacity but that reserve sharing can significantly reduce physical (MW) reserve requirements (from 25%-26% to 18%-19% of average load in high solar scenarios). It finds that the value of forecast error reserve sharing declines with higher levels of solar and wind generation, due to lower wholesale energy and reserve prices. Even with declines in wholesale prices, forecast error reserve sharing can still provide substantial value (as much as $\$$400 million per year in a high solar scenario), though with higher levels of solar, wind, and electricity storage, this value is increasingly tied to avoiding scarcity prices. The results suggest the importance of coordinated capacity expansion planning for forecast error reserve sharing.

14 SOLAR ENERGY↗

Solar and Wind Forecast Error Reserve Sharing in a Multi-Utility Region

As electricity systems transition to higher levels of solar and wind generation, electric system operators will likely need to hold additional reserves to manage solar and wind forecast error. Because solar and wind forecast errors tend to be weakly correlated across space, system operators can reduce their reserve requirements by sharing reserves. This paper examines the benefits of forecast error reserve sharing among balancing areas in the Southeastern United States, in scenarios in which solar and wind generation ranges from 34% to 65% of total generation. It finds that day-ahead forecast error reserve requirements increase linearly with growth in solar and wind generation capacity (6%-10% of total capacity), but that reserve sharing can significantly reduce these requirements (by 6%-29%). It finds that, in economic terms, the value of forecast error reserve sharing ($\$$0.09-$\$$1.24 billion per year, $\$$0.12-$\$$1.68/MWh of load across scenarios) tends to decline with higher levels of solar and wind generation, due to lower reserve and energy prices. Even with declines in reserve prices, forecast error reserve sharing can still provide substantial value, though with higher levels of solar, wind, and electricity storage this value is increasingly tied to avoiding scarcity prices.

14 SOLAR ENERGY↗

Market optimization and technoeconomic analysis of hydrogen-electricity coproduction systems

Decarbonization efforts across North America, Europe, and beyond rely on variable renewable energy sources such as wind and solar, as well as alternative fuels, such as hydrogen, to support the sustainable energy transition. These advancements have prompted a need for more flexibility in the electric grid to complement non-dispatchable energy sources and increased demand from electrification. Integrated energy systems are well suited to provide this flexibility, but conventional technoeconomic modeling paradigms neglect the time-varying dynamic nature of the grid and thus undervalue resource flexibility. In this work, we develop a computational optimization framework for dynamic market-based technoeconomic comparison of integrated energy systems that coproduce low-carbon electricity and hydrogen (e.g., solid oxide fuel cells, solid oxide electrolysis) against technologies that only produce electricity (e.g., natural gas combined cycle with carbon capture) or only produce hydrogen. Our framework starts with rigorous physics-based process models, built in the open-source Institute for the Design of Advanced Energy Systems (IDAES) modeling and optimization platform, for six energy process concepts. Using these rigorous models and a workflow to optimally design each technology, the framework is shown to be capable of evaluating new and emerging technologies in varying energy markets under a plethora of future scenarios (i.e., renewables penetration, carbon tax, etc.). Ultimately, our framework finds that solid oxide fuel cell-based coproduction systems achieve positive profits for 85% of the analyzed market scenarios. From these market optimization results, we use multivariate linear regression (R 2 values up to 0.99) to determine which electricity price statistics are most significant to predict the optimized annual profit of each system. The proposed framework provides a powerful tool for directly comparing flexible, multi-product energy process concepts to help discern optimal technology and integration options.

08 HYDROGEN↗

Best Practices Guide for Energy-Efficient Data Center Design

This guide provides an overview of best practices for energy-efficient data center design which spans the categories of information technology (IT) systems and their environmental conditions, data center air management, cooling and electrical systems, and heat recovery. IT system energy efficiency and environmental conditions are presented first because measures taken in these areas have a cascading effect of secondary energy savings for the mechanical and electrical systems. This guide concludes with a section on metrics and benchmarking values by which a data center and its systems energy efficiency can be evaluated. No design guide can offer “the most energy-efficient” data center design but the guidelines that follow offer suggestions that provide efficiency benefits for a wide variety of data center scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DC-to-DC power supply for light aircraft flight testing

The power supply unit was developed to serve as the power source for a loran-C receiver. The power supply can be connected directly to the aircraft's electrical system, and is compatible with either 14 or 28 volt electrical systems. Design specifications are presented for the unit along with a description of the circuit design.

Yost, S. R.↗

Chemical and Solar Electric Propulsion Systems Analyses for Mars Sample Return Missions

Conceptual in-space transfer stages, including those utilizing solar electric propulsion, chemical propulsion, and chemical propulsion with aerobraking or aerocapture assist at Mars, were evaluated. Roundtrip Mars sample return mission vehicles were analyzed to determine how specific system technology selections influence payload delivery capability. Results show how specific engine, thruster, propellant, capture mode, trip time and launch vehicle technology choices would contribute to increasing payload or decreasing the size of the required launch vehicles. Heliocentric low-thrust trajectory analyses for Solar Electric Transfer were generated with the SEPTOP code.

Donahue, Benjamin B.↗

Bishop Paiute's Residential Solar Program Phase III

The project consisted of the design, installation, inspection, interconnection and monitoring of 40 grid-tied solar electric systems, totaling up to 108 kW rated capacity, on qualified existing low-income single-family homes located within the Bishop Paiute Reservation. The systems are to provide at least 30-75% savings in displaced electricity totaling 175,000 kWh/year. After the DOE grant contract was signed, the Tribal Employment Rights Ordinance (TERO) board voted to reduce the tribal tax to work on the reservation for these low-income projects from 4% to 1%. This generous reduction was applied back into the community solar project and two additional tribal homes were added for a new total of 40 grid-tied solar electric systems, totaling up to 113 kW rated capacity (two more than originally planned) projects. Additionally, each homeowner was educated on energy efficiency and how solar works and saves them money. The estimated 75% savings on monthly electric bills brings financial relief to tribal homeowners and makes a significant difference on the reservation; giving low-income families money to spend on other essential items, while reducing their carbon footprint in this remote tribal reservation. The GRID IE program and this tribal project had a training component for tribal members to get free hands-on job training on 8 of the 40 homes. Those tribal members that came out to train with GRID IE could then be eligible for the “train to hire” portion of the program, on the remaining 32 homes. Overall, the triple impact of the Bishop Paiute Tribe Residential Solar Program Phase III—affordable energy for low-income families, on-site clean energy production, and hands-on solar installation jobs for local workers—these all help build the Tribe’s energy, economic, environmental goals and offers local self-sufficiency while supporting energy independence to the neediest on the Reservation.

14 SOLAR ENERGY↗

Power supply sharing in the Apollo telescope mount electrical power system

A modular dc power supply power sharing technique was developed for the Apollo telescope mount electrical power sytem on Skylab. The advantages and disadvantages of various techniques used are reviewed and compared. The new technique design is discussed, and results of its implementation in the power system are reviewed.

Lanier, R., Jr.↗