Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy efficient computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Elastic Wave Propagation in Curvilinear Coordinates with Mesh Refinement Interfaces by a Fourth Order Finite Difference Method

In this work, we develop a fourth order accurate finite difference method for the three dimensional elastic wave equation in isotropic media with the piecewise smooth material property. In our model, the material property can be discontinuous at curved interfaces. The governing equations are discretized in second order form on curvilinear meshes by using a fourth order finite difference operator satisfying a summation-by-parts property. The method is energy stable and high order accurate. The highlight is that mesh sizes can be chosen according to the velocity structure of the material so that computational efficiency is improved. At the mesh refinement interfaces with hanging nodes, physical interface conditions are imposed by using ghost points and interpolation. With a fourth order predictor-corrector time integrator, the fully discrete scheme is energy conserving. Numerical experiments are presented to verify the fourth order convergence rate and the energy conserving property.

58 GEOSCIENCES↗

Multi-modal Energy-optimal Trip Scheduling in Real-time (METS-R) for Transportation Hubs (Final Report)

This report summarizes the work performed under the award number EE0008524. The project develops the Multi-modal Energy-optimal Trip Scheduling in Real-time (METS-R) platform as the next-generation transportation solution based on autonomous electric vehicles (AEV) serving passenger trips from and to urban transportation hubs, to substantially reduce transportation energy consumption. Extensive data collection and analyses were first conducted to understand the demand patterns and energy consumption of hub-based on-road trips. Then, a data-driven framework that consists of an analytical module and a simulation module was proposed. For the analytical module, five planning + operation tools were developed to support the planning and energy-efficient operations of urban AEV services: the charging station planning that robotically allocates charging supplies based on the stationary charging demand distribution; the transit planning and demand adaptive scheduling model that efficiently generates\ candidate transit routes from hubs to other places and dynamically adjusts the transit time table to fit the current demand; the online energy-efficient routing that learns the energy-optimal paths from observations of link-level energy consumption in real-time; the hub-based ridesharing that matches trip requests together with account for the uncertainty of future trip demand and vehicle supply; and finally, the integrated demand prediction and anomaly detection pipeline that leverages the flight/train time table and support other planning/operation tools. To demonstrate the performance of these tools, a scalable high-performance agent-based simulator was built. We divided the urban space into multiple service zones where each zone was considered as an agent for passenger generation and vehicle charging. Two types of AEV agents were coded to model two types of mobility services: AEV taxi and AEV transit. For the AEV taxi, the team implemented the functions of pickup/drop-off passengers, energy-efficient routing, ridesharing, fleet rebalancing, and recharging. For the AEV bus, the team implemented the functions of demand-adaptive route scheduling, passenger boarding, and recharging. A high-performance computing framework was introduced to receive various profiling information (such as link energy updates, vehicle speed) from the simulator instances and communicate the operational commands back to the instances. The numerical experiments show that each of the proposed operational algorithms can reduce energy consumption and improve system efficiency. Furthermore, there exists the need to collectively consider multiple planning + operational strategies as multiple strategies can influence each other in terms of performance impacts. Recommendations for future work related to AEV planning and simulation are discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implausible projections overestimate near-term Bitcoin CO 2 emissions

Bitcoin mining is becoming an increasingly energy-intensive process whose future implications for energy use and CO 2 emissions remain poorly understood. This is in part because—like many IT systems—its computational efficiencies and service demands have been evolving rapidly. Therefore, scenario analyses that explore these implications can fill pressing knowledge gaps, but they must be approached with care. History has shown that poorly constructed scenarios of future IT energy use—often due to overly-simplistic extrapolations of early rapid growth trends—can do more harm than good by spreading misinformation and driving ill-informed decisions. Indeed, the utility of an energy demand scenario is directly proportional to its credibility, which is typically demonstrated through careful attention to technology characteristics and evolution, analytical rigor and transparency, and designing scenarios that align with plausible future outcomes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Precisely computing phonons via irreducible derivatives

Computing phonons from first principles is typically considered a solved problem, yet inadequacies in existing techniques continue to yield deficient results in systems with sensitive phonons. Here, in this study, we circumvent this issue using the lone irreducible derivative (LID) and bundled irreducible derivative (BID) approaches to computing phonons via finite displacements, where the former optimizes precision via energy derivatives and the latter provides the most efficient algorithm using force derivatives. A condition number optimized basis for BID is derived which guarantees the minimum amplification of error. Additionally, a hybrid LID-BID approach is formulated, in which select irreducible derivatives computed using LID replace BID results. We illustrate our approach on two prototypical systems with sensitive phonons: the shape memory alloy AuZn and metallic lithium. Comparing our resulting phonons in the aforementioned crystals to calculations in the literature reveals nontrivial inaccuracies. Our approaches can be fully automated, making them well suited for both niche systems of interest and high-throughput approaches.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Turbulence-parameter estimation for current-energy converters using surrogate model optimization

Surrogate models maximize information utility by building predictive models in place of computational or experimentally expensive model runs. Marine hydrokinetic current energy converters require large-domain simulations to estimate array efficiencies and environmental impacts. Meso-scale models typically represent turbines as actuator discs that act as momentum sinks and sources of turbulence and its dissipation. An OpenFOAM model was developed where actuator disc k-ε turbulence was characterized using an approach developed for flows through vegetative canopies. Turbine-wake data from laboratory flume experiments collected at two influent turbulence intensities were used to calibrate parameters in the turbulence-source terms in the k-ε equations. Additionally, parameter influences on longitudinal wake profiles were estimated using Gaussian process regression with subsequent optimization minimizing the objective function within 3.1% of those obtained using the full model representation, but for 74% of the computational cost (far fewer model runs). This framework facilitates more efficient parameterization of the turbulence-source equations using turbine-wake data.

16 TIDAL AND WAVE POWER↗

Blackcomb2: Hardware-Software Co-design for Nonvolatile Memory in Exascale Systems

The impending shift from DRAM and Flash to fast nonvolatile memory (NVM) provides a game-changing opportunity to rethink traditional system architectures; to address their energy inefficiencies; to leverage the new devices for greater performance; and to exploit the new capability of nonvolatility to enhance system resilience, even in the face of larger system scale and degraded reliability of components. Building on the accomplishments of the Blackcomb Project, funded in 2010, we propose to identify, evaluate, and optimize the most promising NVM hardware and software technologies, which are essential to provide the necessary memory capacity, performance, resilience, and energy efficiency in exascale systems. Capacity and energy are the key drivers. Today's pressing application requirements mandate exascale computing; the datasets and concurrency of these applications demand memory capacity that cannot be met by traditional memory technologies. Although charge-based DRAM will endure, experts foresee only modest DRAM capacity gains. And, as moving data between levels of the hierarchy, and storing and accessing data on disk consumes significant energy, a more energy efficient solution is required. We, therefore, posit that exascale systems will need high density, energy-efficient storage technologies, such as nonvolatile memory for access, transformation, and management of exascale data. To address these issues, in this renewal request, we propose continue the work of our vertically- integrated, focussed team, where our co-design is informed by proxies and interactions with DOE co-design centers. In software, we start by assuming that nonvolatility requires new abstractions and new infrastructure, allowing persistent objects, and delivering performance gains for _le systems and robustness through fast checkpointing. In architecture, we evaluate the tradeoffs of performance and energy by employing a scalable and accurate simulation system to analyze realistic proxy applications. Through this co-design process, we rethink the whole memory architecture, from the cell to the array to the device, with ECC, wearout management, and interfaces. Finally, we provide open-source software models of these NVM-based memory systems.

97 MATHEMATICS AND COMPUTING↗

Radiation dose rate distributions of spent fuel dry casks estimated with MAVRIC based on detailed geometry and continuous-energy models

This study presents a detailed comparison of the dose rate distributions of a dry TN–32 fuel cask with two geometry models and two cross-sectional datasets. The accuracies of radiation dose rate estimation and computational efficiencies of each geometry model with two cross-sectional data-sets are compared. The use of automated variance reduction techniques can significantly improve the computational efficiency of such a realistic, deep penetration problem that involves radiation transport from different volumetric sources, thereby eliciting only a small statistical error. Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) is a computational sequence within the SCALE 6.2 code package based on consistent adjoint driven importance sampling (CADIS), a type of automated variance reduction technique. Homogenous and full fuel assembly models are built herein, and two nuclear cross-section libraries (V7–200N47G and continuous energy) are applied in this work. Based on the detailed comparisons, we found that neutron dose rate estimation is more dependent on geometry modeling than on cross-section data. For neutron-induced gamma rays, the dose rate distribution depends on both the spatial self-shielding effect and the cross-section library. The primary gamma rays respectively contribute to the total dose rate by ~91% and ~ 99% on side and top surfaces, and the dose rate accuracy is more dependent on the cross-section library than on geometry modeling. In terms of the computation efficiency and efforts spent on geometry modeling, the homogenous fuel assembly model with the MG library can produce an acceptable dose rate distribution, but the detailed fuel assembly model with the continuous-energy library is required for more precise dose rate estimation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Defect energetics of concentrated solid-solution alloys from ab initio calculations: Ni 0.5 Co 0.5 , Ni 0.5 Fe 0.5 , Ni 0.8 Fe 0.2 and Ni 0.8 Cr 0.2

It has been shown that concentrated solid solution alloys possess unusual electronic, magnetic, transport, mechanical and radiation-resistant properties that are directly related to underlying chemical complexity. Because every atom experiences a different local atomic environment, the formation and migration energies of vacancies and interstitials in these alloys exhibit a distribution, rather than a single value as in a pure metal or dilute alloy. In this study, using ab initio calculations based on density functional theory and special quasirandom structure, we have characterized the distribution of defect formation energy and migration barrier in four Ni-based solid-solution alloys: Ni 0.5 Co 0.5 , Ni 0.5 Fe 0.5 , Ni 0.8 Fe 0.2 and Ni 0.8 Cr 0.2 . As defect formation energies in finite-size models depend sensitively on the elemental chemical potential, we have developed a computationally efficient method for determining it which takes into account the global composition and the local short-range order. In addition we have compared the results of our ab initio calculations to those obtained from available embedded atom method (EAM) potentials. Our results indicate that the defect formation and migration energies are closely related to the specific atomic size in the structure, which further determines the elemental diffusion properties. In conclusion, different EAM potentials yield different features of defect energetics in concentrated alloys, pointing to the need for additional potential development efforts in order to allow spatial and temporal scale-up of defect and simulations, beyond those accessible to ab initio methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of Nano-Carbon Materials for Hydrogen Sorption

Research undertaken has added to the understanding of several critical areas, by providing both negative answers (and therefore eliminating expensive further studies of unfeasible paths) and positive feasible options for storage. Theoretical evaluation of the early hypothesis of storage on pure carbon single wall nanotubes (SWNT) has been scrutinized with the use of comprehensive computational methods (and experimental tests by the Center partners), and demonstrated that the fundamentally weak binding energy of hydrogen is not sufficiently enhanced by the SWNT curvature or even defects, which renders carbon nanotubes not practical media. More promising direction taken was towards 3-dimensional architectures of high porosity where concurrent attraction of H2 molecule to surrounding walls of nano-scale cavities can double or even triple the binding energy and therefore make hydrogen storage feasible even at ambient or somewhat lower temperatures. An efficient computational tool has been developed for the rapid capacity assessment combining (i) carbon-foam structure generation, (ii) accurate empirical force fields, with quantum corrections for the lightweight H2, and (iii) grand canonical Monte Carlo simulation. This made it possible to suggest optimal designs for carbon nanofoams, obtainable via welding techniques from SWNT or by growth on template-zeolites. As a precursor for 3D-foams, we have investigated experimentally the synthesis of VANTA (Vertically Aligned NanoTube Arrays). This can be used for producing nano-foams. On the other hand, fluorination of VANTA did not show promising increase of hydrogen sorption in several tests and may require further investigation and improvements. Another significant result of this project was in developing a fundamental understanding of the elements of hydrogen spillover mechanisms. The benefit of developed models is the ability to foresee possible directions for further improvement of the spillover mechanism.

08 HYDROGEN↗

Acceleration of Radiance for Lighting Simulation by Using Parallel Computing with OpenCL

We report on the acceleration of annual daylighting simulations for fenestration systems in the Radiance ray-tracing program. The algorithm was optimized to reduce both the redundant data input/output operations and the floating-point operations. To further accelerate the simulation speed, the calculation for matrix multiplications was implemented using parallel computing on a graphics processing unit. We used OpenCL, which is a cross-platform parallel programming language. Numerical experiments show that the combination of the above measures can speed up the annual daylighting simulations 101.7 times or 28.6 times when the sky vector has 146 or 2306 elements, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application of computational science for fossil fuel conversion processes with carbon capture

Projections indicate that fossil fuel use will be an important part of the energy portfolio for the US and the world. Advanced fossil-fuel technologies are being developed to improve the efficiency and reduce CO2 emissions. NETL is applying computational science at different scales to facilitate the development of these advanced technologies. At atomic-scales, computational chemistry is used for developing better CO2 and H2 membranes, CO2 sorbents, and catalysts. At device-scales, computational methods for modeling multiphase flow phenomena enable the description of gas-solids flows occurring in devices such as coal gasifiers. At the plant-scale, steady-state and dynamic models are used for the optimization and control of coal conversion plants. The APECS technology developed at NETL improves the fidelity of plant-scale models by including device-scale models. This paper describes the use of models at different scales and outlines a vision for combining models at different scales to accelerate fossil energy technology development.

03 NATURAL GAS↗

EUREICA: Efficient UltRa Endpoint IoT-enabled Coordinated Architecture

The electricity grid has evolved from a physical system to a cyber-physical system with digital devices that perform measurement, control, communication, computation, and actuation. The increased penetration of distributed energy resources (DERs) that include renewable generation, flexible loads, and storage provides extraordinary opportunities for improvements in efficiency and sustainability. However, they can introduce new vulnerabilities in the form of cyberattacks, which can cause significant challenges in ensuring grid resilience. The purpose of this project was to develop a framework ((Efficient, Ultra-REsilient, IoT-Coordinated Assets, or EUREICA)for achieving grid resilience through suitably coordinated assets including a network of Internet of Things (IoT) devices, and a local electricity market (LEM) to identify trustable assets and carry out this coordination. Situational Awareness (SA) of locally available DERs with the ability to inject power or reduce consumption is enabled by the market, together with a monitoring procedure for their trustability and commitment. Experiments conducted during this project demonstrated that, with this SA, a variety of cyberattacks can be mitigated using local trustable resources without stressing the bulk grid. The demonstrations were carried out using a variety of high-fidelity co-simulation platforms, real-time hardware-in-the-loop validation, and a utility-friendly simulator.

14 SOLAR ENERGY↗

Method for computationally efficient design of dielectric laser accelerator structures

Here, dielectric microstructures have generated much interest in recent years as a means of accelerating charged particles when powered by solid state lasers. The acceleration gradient (or particle energy gain per unit length) is an important figure of merit. To design structures with high acceleration gradients, we explore the adjoint variable method, a highly efficient technique used to compute the sensitivity of an objective with respect to a large number of parameters. With this formalism, the sensitivity of the acceleration gradient of a dielectric structure with respect to its entire spatial permittivity distribution is calculated by the use of only two full-field electromagnetic simulations, the original and ‘adjoint’. The adjoint simulation corresponds physically to the reciprocal situation of a point charge moving through the accelerator gap and radiating. Using this formalism, we perform numerical optimizations aimed at maximizing acceleration gradients, which generate fabricable structures of greatly improved performance in comparison to previously examined geometries.

43 PARTICLE ACCELERATORS↗

1CPN: A coarse-grained multi-scale model of chromatin

A central question in epigenetics is how histone modifications influence the 3D structure of eukaryotic genomes and, ultimately, how this 3D structure is manifested in gene expression. The wide range of length scales that influence the 3D genome structure presents important challenges; epigenetic modifications to histones occur on scales of angstroms, yet the resulting effects of these modifications on genome structure can span micrometers. There is a scarcity of computational tools capable of providing a mechanistic picture of how molecular information from individual histones is propagated up to large regions of the genome. In this work, a new molecular model of chromatin is presented that provides such a picture. This new model, referred to as 1CPN, is structured around a rigorous multiscale approach, whereby free energies from an established and extensively validated model of the nucleosome are mapped onto a reduced coarse-grained topology. As such, 1CPN incorporates detailed physics from the nucleosome, such as histone modifications and DNA sequence, while maintaining the computational efficiency that is required to permit kilobase-scale simulations of genomic DNA. The 1CPN model reproduces the free energies and dynamics of both single nucleosomes and short chromatin fibers, and it is shown to be compatible with recently developed models of the linker histone. It is applied here to examine the effects of the linker DNA on the free energies of chromatin assembly and to demonstrate that these free energies are strongly dependent on the linker DNA length, pitch, and even DNA sequence. In conclusion, the 1CPN model is implemented in the LAMMPS simulation package and is distributed freely for public use.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗