SEARCH · Search NASA
Results for “FLUID MEASUREMENT”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Buried wire gage for wall shear stress measurements
A buried wire gage for measuring wall shear stress in fluid flow was studied and further developed. Several methods of making this relatively new type of gage were examined to arrive at a successful technique that is well-suited for wind-tunnel testing. A series of measurements was made to demonstrate the adequacy of a two-point calibration procedure for these gages. The buried wire gage is also demonstrated to be ideally suited for quantitative measurement of wall shear stress in wind-tunnel testing.
Dynamic response of viscous compressible fluids in rigid tubes
Data on experimental verification of Iberall's analysis applies to such problems as pressure sensing, pneumatic control circuits with bellows, measuring irregular shaped volumes, and transmitting fluid power by pulsating flow.
Temperature-Averaging Thermal Probe
Temperature-averaging thermal probe measures long-term temperature fluctuations in fluid environment. Consists of temperature probe embedded inside thermally massive material. Probe measurements used to estimate powerplant heating and cooling loads, map temperature profiles, and calibrate more-sensitive temperature probes.
Fiber-Optic Strain-Gage Tank Level Measurement System for Cryogenic Propellants
Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult problem. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. These methods are designed to measure tank-level, but when the fluids are in supercritical state, the liquid-gas interface disappears. Furthermore, there is a need for a non-intrusive measurement system; that is, the sensors should not require tank modifications and/or disturb the fluids. This paper describes a simple, but effective method to determine propellant mass by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a much better quality signal across all regimes during an engine test. Experimental results also show that the use of fiber optic strain gages (FOSG) over classic foil strain gages extends the operation time (before the system becomes uncalibrated), and increases accuracy. Finally, a procedure is defined whereby measurements from the FOSG mounted on the tank supporting structure are compensated using measurements of a FOSG mounted on a reference plate and temperature measurements of the structure. Results describing the performance of a deployed system that measures tank level during propulsion tests are included.
A device for measuring sonic velocity and compressor Mach number
A device has been developed which measures the velocity of sound in fluids at stagnation and is especially adaptable to turbine and compressor testing for which the constituency of the working fluid may be in doubt. By utilizing the shaft frequency of a rotary compressor, the instrument can also be used to provide a direct measurement of the compressor Mach number (ratio of blade-tip velocity to inlet velocity of sound at stagnation). A Helmholtz resonator is employed in the measurement of the sound velocity. Viscous effects in the orifice of the Helmholtz resonator are shown to be important and can be taken into account with the help of a parameter obtained from Stokes solution of the flow near an oscillating wall. This parameter includes the kinematic viscosity of the fluid and the frequency of sound in the resonator. When these effects are recognized, the resonator can be calibrated to measure velocity of sound or compressor Mach number to an accuracy of better than 0.5 percent.
DYNAMX: A Low Temperature Microgravity Investigation of Phase Transitions
The Critical Dynamics in Microgravity Experiment, DYNAMX, will investigate the effects on the superfluid transition in 4 He of currents generated by heat flow, measuring the thermal conductivity in the fluid as a function of applied heat. DYNAMX will also take advantage of the weightless environment to measure the conductivity properties in the region of the interface between the two phases. Thus, DYNAMX represents an experiment that will explore a system driven far from equilibrium. This paper will describe the science objectives, the current design of the experiment apparatus, the steps being taken to prepare this experiment for flight, and the results of ground-based feasibility demonstrations now underway.
Synchrotron FTIR imaging of OH in quartz mylonites
Previous measurements of water in deformed quartzites using conventional Fourier transform infrared spectroscopy (FTIR) instruments have shown that water contents of larger grains vary from one grain to another. However, the non-equilibrium variations in water content between neighboring grains and within quartz grains cannot be interrogated further without greater measurement resolution, nor can water contents be measured in finely recrystallized grains without including absorption bands due to fluid inclusions, films, and secondary minerals at grain boundaries. Synchrotron infrared (IR) radiation coupled to a FTIR spectrometer has allowed us to distinguish and measure OH bands due to fluid inclusions, hydrogen point defects, and secondary hydrous mineral inclusions through an aperture of 10 µm for specimens > 40 µm thick. Doubly polished infrared (IR) plates can be prepared with thicknesses down to 4–8 µm, but measurement of small OH bands is currently limited by strong interference fringes for samples < 25 µm thick, precluding measurements of water within individual, finely recrystallized grains. By translating specimens under the 10 µm IR beam by steps of 10 to 50 µm, using a software-controlled x - y stage, spectra have been collected over specimen areas of nearly 4.5 mm 2 . This technique allowed us to separate and quantify broad OH bands due to fluid inclusions in quartz and OH bands due to micas and map their distributions in quartzites from the Moine Thrust (Scotland) and Main Central Thrust (Himalayas). Mylonitic quartzites deformed under greenschist facies conditions in the footwall to the Moine Thrust (MT) exhibit a large and variable 3400 cm -1 OH absorption band due to molecular water, and maps of water content corresponding to fluid inclusions show that inclusion densities correlate with deformation and recrystallization microstructures. Quartz grains of mylonitic orthogneisses and paragneisses deformed under amphibolite conditions in the hanging wall to the Main Central Thrust (MCT) exhibit smaller broad OH bands, and spectra are dominated by sharp bands at 3595 to 3379 cm -1 due to hydrogen point defects that appear to have uniform, equilibrium concentrations in the driest samples. The broad OH band at 3400 cm -1 in these rocks is much less common. The variable water concentrations of MT quartzites and lack of detectable water in highly sheared MCT mylonites challenge our understanding of quartz rheology. However, where water absorption bands can be detected and compared with deformation microstructures, OH concentration maps provide information on the histories of deformation and recovery, evidence for the introduction and loss of fluid inclusions, and water weakening processes.
Analysis of dynamic characteristics of fluid force induced by labyrinth seal
Flow patterns of the labyrinth seal are experimentally investigated for making a mathematical model of labyrinth seal and to obtain the flow induced force of the seal. First, the flow patterns in the labyrinth chamber are studied on the circumferential flow using bubble and on the cross section of the seal chamber using aluminum powder as tracers. And next, the fluid force and its phase angle are obtained from the measured pressure distribution in the chamber and the fluid force coefficients are derived from the fluid force and the phase angle. Those are similar to the expression of oil film coefficients. As a result, it is found that the vortices exist in the labyrinth chambers and its center moves up and down periodically. The pressure drop is biggest in the first stage of chambers and next in the last stage of chambers.
Fluid and electrolyte shifts during bed rest with isometric and isotonic exercise
It is difficult to separate the effects of reduction in hydrostatic pressure from that of reduced energy expenditure when investigating the confinement deconditioning problem. Experiments were conducted on seven healthy young men aged 19-21 yr with the purpose of separating these two factors by using isotonic physical exercise during bed rest to provide a daily energy expenditure greater than normal ambulatory levels. Fluid and electrolyte shifts were measured during three two-week bed rest periods, each of which being separated by a three-week ambulatory recovery period. During two of the three bed rest periods they performed isometric and isotonic exercises to compare their effects on fluid and electrolyte shifts during bed rest. It is shown that during bed rest, preservation of the extracellular volume takes precedence over maintenance of the plasma volume and that this mechanism is independent of the effects of isometric or isotonic exercise.
Spaceflight payload design flight experience G-408
Worcester Polytechnic Institute's first payload of spaceflight experiments flew aboard Columbia, STS-40, during June of 1991 and culminated eight years of work by students and faculty. The Get Away Special (GAS) payload was installed on the GAS bridge assembly at the aft end of the cargo bay behind the Spacelab Life Sciences (SLS-1) laboratory. The Experiments were turned on by astronaut signal after reaching orbit and then functioned for 72 hours. Environmental and experimental measurements were recorded on three cassette tapes which, together with zeolite crystals grown on orbit, formed the basis of subsequent analyses. The experiments were developed over a number of years by undergraduate students meeting their project requirements for graduation. The experiments included zeolite crystal growth, fluid behavior, and microgravity acceleration measurement in addition to environmental data acquisition. Preparation also included structural design, thermal design, payload integration, and experiment control. All of the experiments functioned on orbit and the payload system performed within design estimates.
What does it take to “see” air leakage through a building envelope?
Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.
Mapping Local Dissipation and Entropy Production in Complex and Active Fluids
While global entropy production provides a measure of irreversibility, its partitioning into contributions from local regions is key to understanding the mechanisms underlying time-reversal symmetry breaking in complex systems and active matter. Here, by analyzing local heat flows and fluxes, we propose a framework that enables the mapping of local dissipation and entropy production in a nonequilibrium system. We test this approach in simulations of fluids driven through complex environments and active systems. We connect the results across the local and global scales by showing that local dissipation and entropy production satisfy a local version of the usual (global) fluctuation theorem, which accounts for the correlations between the local region and its surroundings. Interestingly, in the case of the active fluid, our analysis reveals that these correlations are of opposite signs for the active (stochastic) and passive (deterministic) contributions to local dissipation.
Interfacial tension of fluids near critical points and two-scale-factor universality
Measurements of interfacial tension in the critical region of a wide variety of fluids are reviewed. The data are analyzed using theoretical values of the critical exponents to obtain amplitude ratios. Many of the data are consistent within a few percent of sigma(0). Comparison of these amplitude ratios with ratios from a field-theory calculation and from a simulation suggests that the theoretical values are about half the experimental ones. Systematic errors which are the source of this discrepancy are discussed. The data sources and processing procedures of this study are also discussed, pointing out that for liquid-vapor systems the capillary length often has a remarkably simple temperature dependence.
A technique to measure rotordynamic coefficients in hydrostatic bearings
An experimental technique is described for measuring the rotordynamic coefficients of fluid film journal bearings. The bearing tester incorporates a double-spool shaft assembly that permits independent control over the journal spin speed and the frequency of an adjustable-magnitude circular orbit. This configuration yields data that enables determination of the full linear anisotropic rotordynamic coefficient matrices. The dynamic force measurements were made simultaneously with two independent systems, one with piezoelectric load cells and the other with strain gage load cells. Some results are presented for a four-recess, oil-fed hydrostatic journal bearing.
Direct sunlight facility for testing and research in HCPV
A facility for testing different components for HCPV application has been developed in the framework of 'Fotovoltaico ad Alta Efficienza' (FAE) project funded by the Sicilian Regional Authority (PO FESR Sicilia 2007/2013 4.1.1.1). The testing facility is equipped with an heliostat providing a wide solar beam inside the lab, an optical bench for mounting and aligning the HCPV components, electronic equipments to characterize the I-V curves of multijunction cells operated up to 2000 suns, a system to circulate a fluid in the heat sink at controlled temperature and flow-rate, a data logging system with sensors to measure temperatures in several locations and fluid pressures at the inlet and outlet of the heat sink, and a climatic chamber with large test volume to test assembled HCPV modules.
Effects of hydraulic fluid CVCM on silver-Teflon
Changes in the solar absorptance of silver-Teflon (Ag/FEP) surfaces were measured after contamination by the outgassing products of hydraulic fluid and irradiation by solar simulators. Although radiator surfaces are selected for stability to the solar ultraviolet and particulate environment, contaminant deposition and their interaction with solar exposure can degrade their performance. The test procedure to deposit the hydraulic fluid collected volatile condensible material (CVCM), irradiate, and determine solar absorptance changes by reflectance measurements using a spectrophotometer and a solar simulator is described. The tests showed that for the estimated deposition rates on the Ag/FEP, the hydraulic fluid CVCM fraction remaining under normal conditions (above -40 C) would not degrade its performance. The residual CVCM can be easily removed from Ag/FEP by wiping with a solvent saturated flannel. The changes in solar absorptance with the CVCM film thickness and the radiation exposure duration are reported, concluding that vacuum ultraviolet radiation did not prevent easy removal of CVCM.
Effects of Retronasal Smelling, Variety and Choice on Appetite and Satiety
Four principal areas were investigated. Nasal Patency: Measure nasal tissue swelling and airflow in BR and compare this to PreBR baseline and PostBR recovery; Ask subjects to self‐assess nasal congestion at each test to compare with Astronaut self‐assessment. Odorant Identification: Measure subject's ability to recognize odorants obtained from food samples taken from FARU (Flight Analog Research Unit) menu and compare this with recognition of food odors not available on FARU; Compare subject assessed ratings of odorant intensity and food liking with nasal airflow measurements to determine effect of fluid shift on smell ability. Meal Acceptability: Determine the onset and progression of reported 'menu fatigue' during BR; Determine whether decreased nasal airflow or smell ability are factors in 'menu fatigue'. Daily Mood and Health: Record mood changes during study and compare with meal acceptability and smell ability. A change in smell ability is measured by tracking subject perception of 35 odorants from admission to the FARU through to dismissal.