Search NASA⌕ Search

SEARCH · Search NASA

Results for “FPGA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Nonlinear dynamical system approaches towards neural prosthesis

An asynchronous discrete-state spiking neurons is a wired system of shift registers that can mimic nonlinear dynamics of an ODE-based neuron model. The control parameter of the neuron is the wiring pattern among the registers and thus they are suitable for on-chip learning. In this paper an asynchronous discrete-state spiking neuron is introduced and its typical nonlinear phenomena are demonstrated. Also, a learning algorithm for a set of neurons is presented and it is demonstrated that the algorithm enables the set of neurons to reconstruct nonlinear dynamics of another set of neurons with unknown parameter values. The learning function is validated by FPGA experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact digital time differential perturbed angular correlation-spectrometer using field programmable gate arrays and various timestamp algorithms

A user-friendly fully digital time differential perturbed angular correlation (TDPAC)-spectrometer with six detectors and fast digitizers using field programmable gate arrays (FPGA) is described and performance data are given. The new spectrometer has an online data analysis feature, a compact size, and a time resolution such as conventional analog spectrometers. Its calculation intensive part was implemented inside the digitizer. This gives the possibility to change parameters (energy windows, constant fraction trigger delay) and see their influence immediately in the {gamma}-{gamma} correlation diagrams. Tests were performed which showed that the time resolution using a {sup 60}Co source with energy window set at 1.17 MeV and 1.33 MeV is 265 ps with LaBr{sub 3}(Ce) scintillators and 254 ps with BaF{sub 2} scintillators. A true constant fraction algorithm turned out to be slightly better than the constant fraction of amplitude method. The spectrometer performance was tested with a TDPAC measurement using a {sup 44}Ti in rutile source and a positron lifetime measurement using {sup 22}Na. The maximum possible data rate of the spectrometer is 1.1 x 10{sup 6} {gamma} quanta per detector and second.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical system for liquid level measurements

This work describes the development of a novel laser instrument for non-contact liquid level measurements. The physical principle of operation is based on the self-mixing effect induced in the laser diode by modulating the laser wavelength. The frequency main tone of the resulting fringes is proportional to the absolute target distance. A high speed FPGA (Field Programmable Gate Array) electronic performs the data acquisition and elaboration. The high elaboration/acquisition speed improves the chance of acquiring good signal also on a moving liquid target. The optical characteristics of the liquid surface have been studied in order to identify the optimal optical configuration when the surface is flat as well as when the surface is rippled. The final low-cost instrument works in real time and is able to track a filling process with 2.5 cm/s of speed, with resolution better than 1 mm for distances up to 50 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 32-channel photon counting module with embedded auto/cross-correlators for real-time parallel fluorescence correlation spectroscopy

Fluorescence correlation spectroscopy (FCS) is a well-established technique to study binding interactions or the diffusion of fluorescently labeled biomolecules in vitro and in vivo. Fast FCS experiments require parallel data acquisition and analysis which can be achieved by exploiting a multi-channel Single Photon Avalanche Diode (SPAD) array and a corresponding multi-input correlator. This paper reports a 32-channel FPGA based correlator able to perform 32 auto/cross-correlations simultaneously over a lag-time ranging from 10 ns up to 150 ms. The correlator is included in a 32 × 1 SPAD array module, providing a compact and flexible instrument for high throughput FCS experiments. However, some inherent features of SPAD arrays, namely afterpulsing and optical crosstalk effects, may introduce distortions in the measurement of auto- and cross-correlation functions. We investigated these limitations to assess their impact on the module and evaluate possible workarounds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-bit quantum random number generation by measuring positions of arrival photons

We report upon the realization of a novel multi-bit optical quantum random number generator by continuously measuring the arrival positions of photon emitted from a LED using MCP-based WSA photon counting imaging detector. A spatial encoding method is proposed to extract multi-bits random number from the position coordinates of each detected photon. The randomness of bits sequence relies on the intrinsic randomness of the quantum physical processes of photonic emission and subsequent photoelectric conversion. A prototype has been built and the random bit generation rate could reach 8 Mbit/s, with random bit generation efficiency of 16 bits per detected photon. FPGA implementation of Huffman coding is proposed to reduce the bias of raw extracted random bits. The random numbers passed all tests for physical random number generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1 ns time to digital converters for the KM3NeT data readout system

The KM3NeT collaboration aims at the construction of a multi-km3 high-energy neutrino telescope in the Mediterranean Sea consisting of thousands of glass spheres (nodes), each of them containing 31 photomultiplier (PMT) of small photocathode area. The readout and data acquisition system of KM3NeT has to collect, treat and send to shore, in an economic way, the enormous amount of data produced by the photomultipliers. For this purpose, 31 high-resolution time-interval measuring channels are implemented on the Field-Programmable Gate Arrays (FPGA) based on Time to Digital Converter (TDC). TDC are very common devices in particles physics experiments. Architectures with low resources occupancy are desirable allowing the implementation of other instrumentation, communication and synchronization systems on the same device. The required resolution to measure both, time of flight and timestamp must be 1 ns. A 4-Oversampling technique with two high frequency clocks is used to achieve this resolution. The proposed TDC firmware is developed using very few resources in Xilinx Kintex-7.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards intelligent diagnostic system employing integration of mathematical and engineering model

The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability of the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well as mathematical model of clustering technique have been widely used in developing the medical diagnostic systems. The selected features will be classified using mathematical models that embedded engineering theory such as artificial intelligence, support vector machine, neural network and fuzzy-neuro system. These classifiers will provide the diagnostic results without human intervention. Among many publishable researches, several prototypes have been developed namely NeuralPap, Neural Mammo, and Cervix Kit. The former system (NeuralPap) is an automatic intelligent diagnostic system for classifying and distinguishing between the normal and cervical cancerous cells. Meanwhile, the Cervix Kit is a portable Field-programmable gate array (FPGA)-based cervical diagnostic kit that could automatically diagnose the cancerous cell based on the images obtained during sampling test. Besides the cervical diagnostic system, the Neural Mammo system is developed to specifically aid the diagnosis of breast cancer using a fine needle aspiration image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact field programmable gate array-based pulse-sequencer and radio-frequency generator for experiments with trapped atoms

We present a compact field-programmable gate array (FPGA) based pulse sequencer and radio-frequency (RF) generator suitable for experiments with cold trapped ions and atoms. The unit is capable of outputting a pulse sequence with at least 32 transistor-transistor logic (TTL) channels with a timing resolution of 40 ns and contains a built-in 100 MHz frequency counter for counting electrical pulses from a photo-multiplier tube. There are 16 independent direct-digital-synthesizers RF sources with fast (rise-time of ∼60 ns) amplitude switching and sub-mHz frequency tuning from 0 to 800 MHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast helicity switching of x-ray circular polarization at beamline P09 at PETRA III

At the resonant scattering and diffraction beamline P09 at PETRA III/DESY, polarization manipulation in the X-ray energy range 3-13 keV is possible using wave-plates. Recently, fast flipping of circular polarization helicity using the Raspberry Pi controlled FPGA (PiLC) device developed at DESY and dedicated piezo-electric flippers has been commissioned. Functionality of the PiLC for XMCD and first XMCD measurements at the Fe K-and Dy-L{sub 3} absorption edges are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transmission diamond imaging detector

Many modern synchrotron techniques are trending toward use of high flux beams and/or beams which require enhanced stability and precise understanding of beam position and intensity from the front end of the beamline all the way to the sample. For high flux beams, major challenges include heat load management in optics (including the vacuum windows) and a mechanism of real-time volumetric measurement of beam properties such as flux, position, and morphology. For beam stability in these environments, feedback from such measurements directly to control systems for optical elements or to sample positioning stages would be invaluable. To address these challenges, we are developing diamond-based instrumented vacuum windows with integrated volumetric x-ray intensity, beam profile and beam-position monitoring capabilities. A 50 µm thick single crystal diamond has been lithographically patterned to produce 60 µm pixels, creating a >1kilopixel free-standing transmission imaging detector. This device, coupled with a custom, FPGA-based readout, has been used to image both white and monochromatic x-ray beams and capture the last x-ray photons at the National Synchrotron Light Source (NSLS). This technology will form the basis for the instrumented end-station window of the x-ray footprinting beamline (XFP) at NSLS-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CP2K: An Electronic Structure and Molecular Dynamics Software Package - Quickstep: Efficient and Accurate Electronic Structure Calculations

CP2K is an open source electronic structure and molecular dynamics software package to perform atomistic simulations of solid-state, liquid, molecular and biological systems. It is especially aimed at massively-parallel and linear-scaling electronic structure methods and state-of-the-art ab-initio molecular dynamics simulations. Excellent performance for electronic structure calculations is achieved using novel algorithms implemented for modern high-performance computing systems. This review revisits the main capabilities of CP2K to perform efficient and accurate electronic structure simulations. The emphasis is put on density functional theory and multiple post-Hartree-Fock methods using the Gaussian and plane wave approach and its augmented all-electron extension. TDK has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (grant agreement No. 716142). VRR has been supported by the Swiss National Science Foundation in the form of Ambizione grant No. PZ00P2 174227 and RZK by the Natural Sciences and Engineering Research Council of Canada (NSERC) through Discovery Grants (RGPIN-2016-0505). GKS and CJM are supported by the US Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences, and Biosciences. UK based work was funded under the embedded CSE programme of the ARCHER UK National Supercomputing Service (http://www.archer.ac.uk), grants eCSE03-011, eCSE06-6, eCSE08-9, eCSE13-17 and the EPSRC (EP/P022235/1) grant “Surface and Interface Toolkit for the Materials Chemistry Community". Computational resources were provided by the Swiss National Supercomputing Centre (CSCS) and Compute Canada. The generous allocation of computing time on the FPGA-based supercomputer “Noctua" at PC2 is kindly acknowledged.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron cyclotron emission detection of neoclassical tearing modes for control for ITER

Successful operation of ITER requires control of magnetic instabilities including neoclassical tearing modes (NTMs) that can degrade confinement and lead to disruption. Low latency detection by electron cyclotron emission (ECE) diagnostics has been demonstrated in a few current experiments. Using a synthetic diagnostic, we demonstrate low latency NTM detection for ITER with plasmas described by ITER IMAS database scenarios and with realistic limitations imposed on the instrumentation by these high temperature scenarios. 2/1 NTMs are detected 430 ms after magnetic island seeding and before island locking. The radiometer configuration was optimized using simulation, and the smallest detectable island size was explored. Island sizes of ∼3 cm are detectable at the 2/1 surface. The simulated signals incorporate recent physics models for island growth and rotation, which show early locking and continued island growth after locking and before disruption. This work determines limits for ITER ECE spatial resolution imposed by relativistic broadening of channels, which informs hardware design. Real-time detection is demonstrated in hardware that is required by ITER, including on an NI PXI-7853R FPGA system. Development of a synthetic diagnostic and details of the hardware will be discussed.

Cyclotron radiation↗

A high-speed, high-efficiency phase controller for coherent beam combining based on SPGD algorithm

A phase controller for coherent beam combining (CBC) of fibre lasers has been designed and manufactured based on a stochastic parallel gradient descent (SPGD) algorithm and a field programmable gate array (FPGA). The theoretical analysis shows that the iteration rate is higher than 1.9 MHz, and the average compensation bandwidth of CBC for 5 or 20 channels is 50 kHz or 12.5 kHz, respectively. The tests show that the phase controller ensures reliable phase locking of lasers: When the phases of five lasers are locked by the improved control strategy with a variable gain, the energy encircled in the target is increased by 23 times than that in the single output, the phase control accuracy is better than λ/20, and the combining efficiency is 92%. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE EFFELSBERG-BONN H I SURVEY: DATA REDUCTION

Starting in winter 2008/2009 an L-band seven-feed-array receiver is used for a 21 cm line survey performed with the 100 m telescope, the Effelsberg-Bonn H I survey (EBHIS). The EBHIS will cover the whole northern hemisphere for decl. > - 5{sup 0} comprising both the galactic and extragalactic sky out to a distance of about 230 Mpc. Using state-of-the-art FPGA-based digital fast Fourier transform spectrometers, superior in dynamic range and temporal resolution to conventional correlators, allows us to apply sophisticated radio frequency interference (RFI) mitigation schemes. In this paper, the EBHIS data reduction package and first results are presented. The reduction software consists of RFI detection schemes, flux and gain-curve calibration, stray-radiation removal, baseline fitting, and finally the gridding to produce data cubes. The whole software chain is successfully tested using multi-feed data toward many smaller test fields (1-100 deg{sup 2}) and recently applied for the first time to data of two large sky areas, each covering about 2000 deg{sup 2}. The first large area is toward the northern galactic pole and the second one toward the northern tip of the Magellanic Leading Arm. Here, we demonstrate the data quality of EBHIS Milky Way data and give a first impression on the first data release in 2011.

79 ASTRONOMY AND ASTROPHYSICS↗

PERFORMANCE OF A NOVEL FAST TRANSIENTS DETECTION SYSTEM

We investigate the signal-to-noise ratio (S/N) of a new incoherent dedispersion algorithm optimized for FPGA-based architectures intended for deployment on the Australian SKA Pathfinder and other Square Kilometre Array precursors for fast transients surveys. Unlike conventional CPU- and GPU-optimized incoherent dedispersion algorithms, this algorithm has the freedom to maximize the S/N by way of programmable dispersion profiles that enable the inclusion of different numbers of time samples per spectral channel. This allows, for example, more samples to be summed at lower frequencies where intra-channel dispersion smearing is larger, or it could even be used to optimize the dedispersion sum for steep spectrum sources. Our analysis takes into account the intrinsic pulse width, scatter broadening, spectral index and dispersion measure of the signal, and the system's frequency range, spectral and temporal resolution, and number of trial dedispersions. We show that the system achieves better than 80% of the optimal S/N where the temporal resolution and the intra-channel smearing time are smaller than a quarter of the average width of the pulse across the system's frequency band (after including scatter smearing). Coarse temporal resolutions suffer a {Delta}t {sup -1/2} decay in S/N, and coarse spectral resolutions cause a {Delta}{nu}{sup -1/2} decay in S/N, where {Delta}t and {Delta}{nu} are the temporal and spectral resolutions of the system, respectively. We show how the system's S/N compares with that of matched filter and boxcar filter detectors. We further present a new algorithm for selecting trial dispersion measures for a survey that maintains a given minimum S/N performance across a range of dispersion measures.

79 ASTRONOMY AND ASTROPHYSICS↗

Instrumentation and Control Selection for the 12 GeV Hall-B Magnets at Jefferson Lab

Here, as part of the Jefferson Lab 12 GeV accelerator upgrade, the Experimental Physics Hall B detector system requires two superconducting magnets – a Torus and a Solenoid. The specifications required maximum space for the detectors which led to the choice of conduction cooling for each magnet. The Torus consists of 6 trapezoidal 'race-track'-type coils connected in series with an operating current of 3770 A. The Solenoid is an actively shielded 5 Tesla magnet consisting of 5 coils connected in series operating at 2416 A. Within the hall the two magnets are located in close proximity to each other and are surrounded by particle detectors. We describe the philosophy behind the instrumentation selection and control design that accounts for this proximity and other challenging working conditions. We describe the choice of sensor technologies, as well as the control and data acquisition methods. The magnet power and cryogenic control sub-systems are implemented using Allen Bradley Control Logix 1756-L72 Programmable Logic Controllers. Sensor instrumentation read-backs are routed into the PLC via National Instruments cRIO hardware (Field Programmable Gate Arrays or FPGA/RT application) using Jefferson Lab designed FPGA-based multi-sensor-excitation-chassis. Configuration, monitoring, and alarm handlers for the magnet systems are provided via an Experimental Physics Instrumentation & Control System interface (EPICS). Failure Modes and Effects Analysis (FMEA) and the requirement to monitor critical parameters during operation guided the selection of instrumentation and associated hardware. The design of the quench protection and voltage tap sub-systems was driven by the anticipated level of voltages developed during a magnet quench. The primary hard-wired quench detection and protection sub-system together with the secondary PLC-based protection sub-system is also discussed. The successful commissioning and subsequent performance of these magnets demonstrates the robustness of the design and implementation approach that was adopted by the Jefferson Lab team and serves as an excellent 'How To' guide for future projects of this size and complexity.

12 GeV↗

Preliminary design overview and performance assessment of the ITER low-field side reflectometer

The design of the ITER low-field side reflectometer (LFSR) has matured to a complete end-to-end preliminary design. LFSR will supply three key plasma measurements: (1) electron density profile, (2) electron density fluctuations, and (3) poloidal rotation. Simultaneous measurements of the three quantities are enabled by an array of six monostatic antennas which inject from an equatorial port on the outboard side of the ITER vessel. Low-loss transmission lines, consisting of corrugated, overmoded waveguide and miter bends, transmit the 30–165 GHz, O- and X-mode signals to and from the ITER plasma. Integrated transmission-line components serve a range of purposes, such as protection from high-power stray radiofrequency radiation, accommodation of transmission-line displacement, and simultaneous measurement of reference and plasma phases during the discharge. Broadband transmission signals are realized by full-band microwave transceivers combined with quasi-optical multiplexing. A field-programmable gate array (FPGA) processor demodulates the profile reflectometer signals, enabling real-time density profile measurements for plasma control system feedback. A full-scale transmission line test facility provides an integrated environment to assess the performance of critical LFSR components. Theoretical modeling together with insertion loss measurements provide the basis for a comprehensive power budget, which accounts for transmitted output power, transmission-line losses, antenna coupling, and plasma effects. Results indicate that high signal-to-noise ratios are achievable with the current design. A synthetic reflectometer model, using real design parameters and baseline ITER profiles, has been developed to estimate the return signal. With evolving microwave and data acquisition technologies, full-band, ultrafast sweeps (<1 μs) will be realizable for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗