Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fermilab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Transfer of EP and Doping Technology for PIP-II HB650 Cavities from Fermilab to Industry

Fermilab has optimized the surface processing conditions for PIP-II high beta 650 MHz cavities. This encompasses conditions for bulk electropolishing, heat treatment, nitrogen doping, post-doping final electropolishing, and post-processing surface rinsing. The technology has been effectively transitioned to industry. This paper highlights the efforts made to fine-tune the process and to smoothly share them with the partner labs and an associated vendor.

Chouhan, V.↗

Transfer Line at Fermilab

Beam loss in high-intensity H- linacs, such as the PIP-II linac at Fermilab, is a critical challenge that requires comprehensive study and understanding to ensure efficient and safe operation. This study explores the various beam loss mechanisms encountered in the PIP-II linac and its beam transfer line, drawing parallels from other high-intensity H- linacs. Key loss mechanisms include residual gas stripping, where H- ions interact with residual gas molecules leading to electron detachment; field stripping, caused by the interaction of H- ions with magnetic fields; and intra-beam stripping, resulting from interactions within the beam itself. Beam halo formation, particularly due to Twiss function mismatch, is another significant source of beam loss, which can be exacerbated by Landau damping mechanisms. Adhering to the 1 W/m loss criterion is essential to maintain hands-on maintenance capability and ensure the longevity of the accelerator components. By understanding these mechanisms and implementing targeted mitigation strategies, the PIP-II linac can achieve its design goals while maintaining safe and efficient operations.

Pathak, Abhishek↗

Progress and Challenges in Traveling-Wave SRF cavity development at Fermilab

Traveling-wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the limit of 50~60MV/m in Standing-wave (SW) technology. The early stages of TW SRF cavity developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. The TW resonance excitation in the 3-cell TW cavity at 2K was demonstrated through the low power RF test in early 2024. A high-power test of the 3-cell in TW mode being prepared. To advance a design and technology to fabricate a novel high gradient TW SRF cavity, FNAL proposed a half-meter TW RF design and R&Ds to realize that are in progress. Here we will report the recent progress in the 3-cell TW cavity and the challenges towards a half-meter scale TW cavity.

Furuta, F.↗

Cryogenic Platforms at Fermilab: Recent Results and Outlook

The Cosmic Quantum group at Fermilab operates three cryogenic facilities dedicated to the development and calibration of superconducting low-threshold detectors and qubits. One of which (LOUD) is located at the surface, while the other two (NEXUS and QUIET) are located 100 m underground enabling low-background device characterization and rare event searches. Recently, we have demonstrated world-leading resolution in the quasiparticle channel for kinetic inductance phonon-mediated detectors as well as the lowest rate of spatially- and temporally- correlated errors ( charge jumps ) in superconducting qubit chips. We have additionally made significant progress in expanding the suite of tools for simulating signal production and readout of these devices. In this talk, I will review these recent results, discuss some nascent projects focused on enhancing sensitivity of these detectors to sub-GeV dark matter, and highlight activities in these facilities over the next year.

Temples, Dylan J.↗

Emittance Measurements with Wire Scanners in the Fermilab Side-Coupled Linac

The Fermilab Side-Coupled Linac accelerates H- beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instru-ments to directly collect information on the beam s transverse distribution. The manipulation of the condi-tions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions. Here we present the results of these studies and characterization of the non-Gaussian transverse beam distribution observed.

43 PARTICLE ACCELERATORS↗

The Fermilab Facility for Dark Matter Discovery (F2D2): A Conceptual PIP-II Beam Stop Facility for Dark Sector Physics

What do the accelerator target stations of the next decade look like? The NuMI beamline, fed by Fermilab s Main Injector, recently exceeded 1 MW beam power. Future experiments fed by the PIP-II superconducting linear accelerator might demand upwards of 2 MW in continuous-wave mode, compared to the pulsed beams typical of neutrino experiments. Looking further into the future, the Muon Collider front end includes a target station with even higher power 5 MW or beyond. How do we build a 2+ MW target facility? How does a high-power, low-energy, CW beam affect target design compared to conventional high-energy neutrino targets? How do we manage radiation and heat? How is the facility serviced? What is the current state of capability, and what technologies do we need to develop? These questions are answered in the context of F2D2, a conceptual target station design for dark sector physics experiments using beam from PIP-II.

Williams, Jonathan K.↗

Updates and Lessons Learned from NuMI Beamline at Fermilab

The Neutrinos at the Main Injector (NuMI) beamline at Fermilab generates an intense muon neutrino beam for the NOvA (NuMI Off-axis 𝜈𝑒 Appearance) long baseline neutrino experiment. Over the years, the NuMI beamline has been pivotal in advancing neutrino physics, providing invaluable data and insights. This presentation offers updates and a comprehensive review of the lessons learned from the operation, maintenance, and monitoring of the NuMI beamline. Key topics include the optimization of beam performance, challenges in maintaining beamline stability, and proposed Machine Learning implementations to enhance monitoring. The talk aims to share best practices and provide a roadmap for future beamline projects, including the Long-Baseline Neutrino Facility (LBNF).

Wickremasinghe, Athula↗

Fermilab high-intensity neutrino program: present and future

This talk will provide an overview of the Fermilab neutrino program, including details for both the accelerator and experiment aspect of the program. The current operation of the proton complex will be discussed, alongside the status of the upcoming PIP-II upgrade and the newly proposed ACE-MIRT upgrade. Additionally, the status of the SBN and NOVA programs will be presented, as well as the status of the upcoming DUNE/LBNF upgrade.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration and Measurement techniques in the LLRF systems of the Fermilab PIP-II Linac

he PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems are a based on two different hardware platforms controlling a variety of cavity types and resonance control systems including temperature, pneumatic and piezzo tuners. The various calibrations required prior to beam operation include, signal power, gradient, amplifier characterization, cavity Q measurement and detune constants. Measurements such as piezzo capacitance, cavity piezo transfer function help in determining tuner health and in devising microphonics control strategies. These measurement and calibration methods of the PIP-II LLRF system are discussed here.

Varghese, P.↗

Timing and Synchronization in the LLRF systems of the Fermilab PIP-II Linac

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

Varghese, Philip↗

Statistical Analysis of Fermilab’s Safety Data

In the past ten months, since the Safety and Security pauses of May 31$^{st}$ and June 29$^{th}$ of 2023, there has been an increase in the number of Total Recordable Counts to the point that there are already more incidents in ten months that at any given year in the past decade. The purpose of this study is to try to determine if this increase could be explained as a statistical fluctuation. We will show that it is very unlikely (essentially 4$\sigma$ unlikely) that the increase is a fluctuation, and therefore there must be a cause. The Safety and Security pauses of the past May and June, and many events thereafter, have been impactful events at Fermilab, so we should feel an obligation to assess their benefit, or detriment, to the safety of our people.

99 GENERAL AND MISCELLANEOUS↗

bj’s Fermilab Years

An evocation of J. D. Bjorken's decade at Fermilab, prepared for the SLAC Symposium, "Remembering Bj," November 9, 2024.

Quigg, Chris↗

On Final Results From the Muon $g\mathrm{-}2$ Experiment at Fermilab

The Muon g-2 Experiment at Fermilab has measured the muon anomalous magnetic moment, a_mu, with unprecedented precision, leveraging a dataset from Runs 1 6 that is 21 times larger than its Brookhaven predecessor. This talk will present the experiment s final result, which serves as a benchmark for testing the Standard Model with high precision. The measurement was performed in a storage ring with a highly uniform magnetic field, where precise beam dynamics understanding is vital to determine the muon anomalous precession frequency. Key to this effort were advanced simulation tools including COSY INFINITY, precise fringe field modeling, and calculations of beam dynamics characteristics like tunes and chromaticity. We will conclude by exploring how the experiment's findings reshape our understanding of particle physics.

Valetov, Eremey [Michigan State U.]↗

3D CAD Modeling and Mechanical Integration at the Mu2e Experiment at Fermilab

This abstract encapsulates a transformative summer internship at Fermilab, focusing on the Mu2e Experiment within the Mechanical Integration and 3D CAD Modeling group. The internship was characterized by a two-phase approach, with the initial month dedicated to the design of an aluminum platform tailored for DS Trench Maintenance. This phase encompassed a comprehensive exploration of structural integrity, material selection, and precision engineering principles, demonstrating an adeptness in CAD modeling and a keen eye for detail. The subsequent month saw a seamless transition into a dynamic phase of the project, wherein the intern played a pivotal role in effecting numerous adjustments across diverse sections of the 3D experiment structure. This phase demanded a nuanced understanding of the intricacies of the Mu2e Experiment and a high level of proficiency in CAD modeling.

3D CAD Modeling↗

Studies of the trigger performance of the ICARUS T600 detector at Fermilab

In recent years, experimental neutrino anomalies were reported: if confirmed, they could hint at the existence of additional sterile neutrino states participating in the mixing phenomenon. The future Short-Baseline Neutrino (SBN) project at Fermilab will pursue sterile neutrino searches, by exploiting three Liquid Argon (LAr) Time Projection Chamber (TPC) detectors located on-axis along the Booster Neutrino Beam (BNB). Aside from SBND and MicroBooNE, ICARUS will be the far detector and will also be interested by the NuMI beam (off-axis). The trigger system is a key component of the detector: it is based on the coincidence of prompt signals from scintillation light in the LAr-TPC (recorded by a system of PhotoMultiplier Tubes, PMTs) with the proton spill extraction of the beam. The present system exploits a majority-based logic and may be complemented by a trigger system based on adder boards, that add the analog signals of the PMTs in groups of 15. Triggering on the sum may help in identifying events closer to the TPC walls, in which there is plenty of light collected by few PMTs and for which the majority condition may not be satisfied. Many tests were carried out to characterize the adder boards, both on the hardware and software sides.

43 PARTICLE ACCELERATORS↗

Proton Dynamics Scenarios in the Integrable Optics Test Accelerator (IOTA) at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab provides a versatile platform for studying the interplay of space-charge, impedance, and non-linear optics in high-intensity hadron beams within synchrotrons and storage rings. This report examines the parameters and dynamics of 2.5~MeV proton beam operations in two configurations of the bare IOTA lattice: one for demonstrating Non-linear Integrable Optics with the Danilov-Nagaitsev magnet, and the other for use with electron cooling. We offer order-of-magnitude estimates of the transverse emittance growth rate as a function of beam intensity, highlighting contributions from residual gas scattering, intra-beam scattering, and space-charge effects. Under nominal conditions, the beam lifetime is projected to be less than 7~minutes at low intensity with the current vacuum quality, and fewer than 100,000~turns at high intensity due to strong space-charge effects. The calculations presented here will guide strategies to mitigate emittance growth and inform future IOTA experiments.

43 PARTICLE ACCELERATORS↗