807 records · Page 45

Mcl-1-Bim complexes accommodate surprising point mutations via minor structural changes

Mcl-1 is an antiapoptotic Bcl-2-family protein that protects cells against death. Structures of Mcl-1, and of other anti-apoptotic Bcl-2 proteins, reveal a surface groove into which the {alpha}-helical BH3 regions of certain proapoptotic proteins can bind. Despite high overall structural conservation, differences in this groove afford binding specificity that is important for the mechanism of Bcl-2 family function. We report the crystal structure of human Mcl-1 bound to a BH3 peptide derived from human Bim and the structures for three complexes that accommodate large physicochemical changes at conserved Bim sites. The mutations had surprisingly modest effects on complex stability, and the structures show that Mcl-1 can undergo small changes to accommodate the mutant ligands. For example, a shift in a leucine side chain fills a hole left by an isoleucine-to-alanine mutation at the first hydrophobic buried position of Bim BH3. Larger changes are also observed, with shifting of helix {alpha}3 accommodating an isoleucine-to-tyrosine mutation at this same position. We surveyed the variation in available Mcl-1 and Bcl-x{sub L} structures and observed moderate flexibility that is likely critical for facilitating interactions of diverse BH3-only proteins with Mcl-1. With the antiapoptotic Bcl-2 family members attracting significant attention as therapeutic targets, these structures contribute to our growing understanding of how specificity is achieved and can help to guide the design of novel inhibitors that target Mcl-1.

36 MATERIALS SCIENCE↗

Mercury Calibration System

U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on actual capabilities of the current calibration technology. As part of the current effort, WRI worked with Thermo Fisher elemental mercury calibrator units to conduct qualification experiments to demonstrate their performance characteristics under a variety of conditions and to demonstrate that they qualify for use in the CEM calibration program. Monitoring of speciated mercury is another concern of this research. The mercury emissions from coal-fired power plants are comprised of both elemental and oxidized mercury. Current CEM analyzers are designed to measure elemental mercury only. Oxidized mercury must first be converted to elemental mercury prior to entering the analyzer inlet in order to be measured. CEM systems must demonstrate the ability to measure both elemental and oxidized mercury. This requires the use of oxidized mercury generators with an efficient conversion of the oxidized mercury to elemental mercury. There are currently two basic types of mercuric chloride (HgCl{sub 2}) generators used for this purpose. One is an evaporative HgCl{sub 2} generator, which produces gas standards of known concentration by vaporization of aqueous HgCl{sub 2} solutions and quantitative mixing with a diluent carrier gas. The other is a device that converts the output from an elemental Hg generator to HgCl{sub 2} by means of a chemical reaction with chlorine gas. The Thermo Fisher oxidizer system involves reaction of elemental mercury vapor with chlorine gas at an elevated temperature. The draft interim protocol for oxidized mercury units involving reaction with chlorine gas requires the vendors to demonstrate high efficiency of oxidation of an elemental mercury stream from an elemental mercury vapor generator. The Thermo Fisher oxidizer unit is designed to operate at the power plant stack at the probe outlet. Following oxidation of elemental mercury from reaction with chlorine gas, a high temperature module reduces the mercuric chloride back to elemental mercury. WRI conducted work with a custom laboratory configured stand-alone oxidized mercury generator unit provided by Thermo Fisher to perform experiments to demonstrate the high efficiency of oxidation on reaction with chlorine gas, and reduction back to elemental mercury.

01 COAL, LIGNITE, AND PEAT↗

Mercury Calibration System

U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on actual capabilities of the current calibration technology. As part of the current effort, WRI worked with Thermo Fisher elemental mercury calibrator units to conduct qualification experiments to demonstrate their performance characteristics under a variety of conditions and to demonstrate that they qualify for use in the CEM calibration program. Monitoring of speciated mercury is another concern of this research. The mercury emissions from coal-fired power plants are comprised of both elemental and oxidized mercury. Current CEM analyzers are designed to measure elemental mercury only. Oxidized mercury must first be converted to elemental mercury prior to entering the analyzer inlet in order to be measured. CEM systems must demonstrate the ability to measure both elemental and oxidized mercury. This requires the use of oxidized mercury generators with an efficient conversion of the oxidized mercury to elemental mercury. There are currently two basic types of mercuric chloride (HgCl{sub 2}) generators used for this purpose. One is an evaporative HgCl{sub 2} generator, which produces gas standards of known concentration by vaporization of aqueous HgCl{sub 2} solutions and quantitative mixing with a diluent carrier gas. The other is a device that converts the output from an elemental Hg generator to HgCl{sub 2} by means of a chemical reaction with chlorine gas. The Thermo Fisher oxidizer system involves reaction of elemental mercury vapor with chlorine gas at an elevated temperature. The draft interim protocol for oxidized mercury units involving reaction with chlorine gas requires the vendors to demonstrate high efficiency of oxidation of an elemental mercury stream from an elemental mercury vapor generator. The Thermo Fisher oxidizer unit is designed to operate at the power plant stack at the probe outlet. Following oxidation of elemental mercury from reaction with chlorine gas, a high temperature module reduces the mercuric chloride back to elemental mercury. WRI conducted work with a custom laboratory configured stand-alone oxidized mercury generator unit provided by Thermo Fisher to perform experiments to demonstrate the high efficiency of oxidation on reaction with chlorine gas, and reduction back to elemental mercury.

01 COAL, LIGNITE, AND PEAT↗

Cygnus Dual Beam Radiographic Facility Refurbishment completed at U1A tunnel in Nevada NNSS meeting Level 2 milestone (P-23 Highlights 6/10/12)

A moratorium was placed on U.S. underground nuclear testing in 1992. In response, the Stockpile Stewardship Program was created to maintain readiness of the existing nuclear inventory through several efforts such as computer modeling, material analysis, and subcritical nuclear experiments (SCEs). As in the underground test era, the Nevada National Security Site (NNSS), formerly the Nevada Test Site, provides a safe and secure environment for SCEs by the nature of its isolated and secure facilities. A major tool for SCE diagnosis installed in the 05 drift laboratory is a high energy x-ray source used for time resolved imaging. This tool consists of two identical sources (Cygnus 1 and Cygnus 2) and is called the Cygnus Dual Beam Radiographic Facility (Figs. 2-6). Each Cygnus machine has 5 major elements: Marx Generator, Pulse Forming Line (PFL), Coaxial Transmission Line (CTL), 3-cell Inductive Voltage Adder (IVA), and Rod Pinch Diode. Each machine is independently triggered and may be fired in separate tests (staggered mode), or in a single test where there is submicrosecond separation between the pulses (dual mode). Cygnus must operate as a single shot machine since on each pulse the diode electrodes are destroyed. The diode is vented to atmosphere, cleaned, and new electrodes are inserted for each shot. There is normally two shots per day on each machine. Since its installation in 2003, Cygnus has participated in: 4 Subcritical Experiments (Armando, Bacchus, Barolo A, and Barolo B), a 12 shot plutonium physics series (Thermos), and 2 plutonium step wedge calibration series (2005, 2011), resulting in well over 1000 shots. Currently the Facility is in preparation for 2 SCEs scheduled for this calendar year - Castor and Pollux. Cygnus has performed well during 8 years of operations at NNSS. Many improvements in operations and performance have been implemented during this time. Throughout its service at U1a, major maintenance and replacement of many hardware items were delayed due to programmatic requirements. It is anticipated that Cygnus will be in service at U1a for another 5 years. With this assumption, it was realized that significant resources and effort should be allotted to bring the hardware back to its original condition, or even to improve elements when appropriate. The Cygnus Refurbishment and Enhancement Project started in April, 2011 with the intent to encompass a major overhaul of Cygnus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MULTIPHYSICS-MODELING OF FIRE-INDUCED URANIUM AEROSOL FORMATION – A-POSTERIORI BENCHMARKING OF EXPERIMENTS

The formulation and solution of a model that properly described the temperature profiles of uranium in fire conditions was prepared, verified and validated, to support a-posteriori benchmarking of historical experiments. Data from the multi-physics model combined with data regression from the experiments provides a useful tool for exploring sources of potential bias in historical experiments. The approaches used are augmented by visual observations and photographic evidence allowing for correlations between various phenomena, independent of whether or not that specific phenomena are part of the validated model. In this manner, the validated model is a tool for a-posteriori benchmarking, and not a model designed to replicate the experimental output exactly for any specific experiment. For experiments like the Clark (2015) experiments, this integrated model (including chemistry) demonstrated that the largest bias was associated in the metallurgy of the coupons. The model developed does serve as a basis for defending which of the historical alloys tested are the most appropriate for any other alloy being considered (e.g., one that has not yet been tested). The model identifies key reactions that impact uranium chemistry and can significantly bias experimental results. Through use of the model and energy balances, data from historical experiments by Elder and Tinkle (1980) were regressed and benchmarked. This study identifies that all uranium alloys are not equal and that there are distinct differences between the dominant alloys representing distinct metallurgical phases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uranium Distribution Coefficient (Kd) Determination and Use in Assessing Transport, Fate, and Risk at Jefferson Proving Ground, I - 18593

Jefferson Proving Ground (JPG), located near Madison, Indiana is a 55,000-acre site with firing ranges for test firing of conventional munitions and depleted uranium penetrators. The penetrators were fired from three positions, but the majority (89 percent) was fired from a single location. Impacts from the penetrators along this firing line created an impact trench roughly 5 meters (m) to 8 m wide, 1,200 m long, and 1 m deep. Periodic surface sweeps were conducted to recover test fired penetrators, but roughly 73,500 kilograms (kg) of depleted uranium (DU) still remain at JPG. Co-located and intermingled with the penetrators are unexploded ordnance (UXO), making complete recovery and site restoration both risky and costly. Understanding the transport and fate of the depleted uranium at JPG was critical to assessing the potential radiological risks posed to human health and the environment from the penetrators and associated impacted soils on site. JPG is underlain by loess (wind-blown silt), glacial till, and carbonate bedrock, and transected by surface water (Big Creek, Middle Fork Creek, and smaller tributaries). The Army determined site-specific values of the uranium distribution coefficient (Kd) for each of the underlying units. The Army evaluated uranium transport and fate in column, groundwater, and surface water models. The Army used the Residual Radiation (RESRAD)- OFFSITE code to complete the uranium risk assessment for a period of 1,000 years. Results from the site-specific Kd tests are presented in this paper along with its use and results in assessing transport, fate, and potential risks associated with exposure to the penetrators remaining at JPG. The authors supported the decommissioning activities discussed in this paper under the direction of and with funding from the U.S. Army, specifically the U.S. Army Installation Management Command (IMCOM, Robert N. Cherry), U.S. Army Environmental Command (AEC, Joan F. Jackson), and U.S. Army Corps of Engineers (USACE, Andrew [Brooks] Evens). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methodology Used in the Radiological Assessment of a Coal-Fired Power Plant

A radiological assessment of the workers and the public potentially affected by the operation of the Teruel Coal-fired Power Plant (the UPT Teruel), was performed under realistic assumptions. This assessment is part of a wider study to characterize the potential radiological impact of Naturally Occurring Radioactive Materials (NORM), in which our team, integrated by University of Extremadura and CIEMAT, is carrying out the study on coal-fired power plants sponsored by the Spanish Nuclear Safety Council (CSN). The study comprises the four biggest coal-fired power plants in Spain. Taking into account the working conditions and the plant specifications, six groups of workers were defined, established considering the 17 working tasks that could be of any importance for this assessment. For the public, considering that the area is barely inhabited, two different recreational scenarios were defined. Therefore, in-plant and outside measurements, needed for the assessment of each scenario, were carried out. Where experimental data were not available or measurements ranged within the natural background radiation values, modelling has been used. Every measured or estimated activity concentration in coal and other used materials or in the by-products generated in the power plant, for every radionuclide in the natural chains of {sup 238}U, {sup 232}Th and {sup 40}K, were below 0.32 Bq g{sup -1}. Those values are under the 0.5 Bq g{sup -1} reference value for exemption and clearance of {sup 238}U, {sup 232}Th and {sup 226}Ra and the 5 Bq g{sup -1} for {sup 40}K recommended in Europe. In the dose evaluations for six groups of workers, a maximum of 21 {mu}Sv a{sup -1} was obtained (mainly due to the inhalation of resuspended particles). For both considered scenarios for the public, all the evaluated doses were below 4.3 {mu}Sv a{sup -1}. These results are considered negligible from a radiological point of view. In this work the models and assumptions used for the evaluation of workers and public doses, the assessment, as well as the most relevant experimental results and conclusions are presented.

54 ENVIRONMENTAL SCIENCES↗

Radiation Hardened Foam Cold Test Plan – Phase-I: Foam Adhesion, Contamination Fixation, Moisture Stresses, Pipe Cutting, and Thermal Profile Testing

This document outlines the Phase-I test objectives and implementation plan for a down-selective foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of an intumescent, fire-retardant foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed in FIU’s Outdoor Test and Evaluation Facility using a mock-up that replicates the operational conditions at the proposed hot test location at F/H labs. Results from the cold test plan will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the site and transported to a proper disposal facility. Phase-I testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of foam fixative in piping, (2) evaluation of the adhesion of the foam fixative in piping under varying moisture conditions, (3) determination of the heat profile of the foam fixative during curing, (4) determination of the relationship between pipe diameter and foam fixative quantity, (5) determination of the internal pipe pressure after foam deployment and curing, (6) development of a leak test standard operating procedure to test for the effectiveness of the foam plug, (7) initiation of a literature review to determine if using a hot tap is a viable method to deliver foam into piping, and (8) initiation of a 10-foot mock up test that will be used in Phase-II cold testing. The cold test will be conducted at FIU and all testing activities will comply with SRNL Conduct of R&D Protocols (SRNL-IM-2020-00019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear Thermal Rocket (NTR) Development Risk Communication

There are clear advantages of development of a Nuclear Thermal Rocket (NTR) for a crewed mission to Mars. NTR for in-space propulsion enables more ambitious space missions by providing high thrust at high specific impulse (approximately 900 sec) that is 2 times the best theoretical performance possible for chemical rockets. Missions can be optimized for maximum payload capability to take more payload with reduced total mass to orbit; saving cost on reduction of the number of launch vehicles needed. Or missions can be optimized to minimize trip time significantly to reduce the deep space radiation exposure to the crew. NTR propulsion technology is a game changer for space exploration. However, "NUCLEAR" is a word that is feared and vilified by some groups and the hostility towards development of any nuclear systems can meet great opposition by the public as well as from national leaders and people in authority. Communication of nuclear safety will be critical to the success of the development of the NTR. Why is there a fear of nuclear? A bomb that can level a city is a scary weapon. The first and only times the Nuclear Bomb was used in a war was on Hiroshima and Nagasaki during World War 2. The "Little Boy" atomic bomb was dropped on Hiroshima on August 6, 1945 and the "Fat Man" on Nagasaki 3 days later on August 9th. Within the first 4 months of bombings, 90- 166 thousand people died in Hiroshima and 60-80 thousand died in Nagasaki. It is important to note for comparison that over 500 thousand people died and 5 million made homeless due to strategic bombing (approximately 150 thousand tons) of Japanese cities and war assets with conventional non-nuclear weapons between 1942- 1945. A major bombing campaign of "firebombing" of Tokyo called "Operation Meetinghouse" on March 9 and 10 consisting of 334 B-29's dropped approximately1,700 tons of bombs around 16 square mile area and over 100 thousand people have been estimated to have died. The declaration of death is very clear for conventional weapons and then the declaration of death due to radiation becomes vague and unclear. This may have been due to people mis-understanding the dangers and effects of radiation when assessing the damage and harm to people initially, but it is also become insidious when expressing opposition to nuclear energy. A nuclear radiation accident can be scary due to the power involved and the fear of radiation release. The International Atomic Energy Agency defines a nuclear and radiation accident a "an event that has led to significant consequences to people, the environment or the facility." There have been 3 commercial nuclear reactor accidents (Chernobyl, Three Mile Island, and Fukushima) that stand out to the public and much of the information about the result and impact to workers, environment, and public can be misleading. Often information is presented without clear correlation with radiation and other pertinent information is left out presenting a very scary situation to affect the emotions of the reader. A very boring but "critically acclaimed" movie was made in 1979 called "The China Syndrome" starring Jane Fonda and Jack Lemmon. The film was released on March 16, 1979, 12 days before the 3-Mile Island nuclear accident in Pennsylvania. The basis from the movie was from a few nuclear plant incidents and in particular, the Brown's Ferry Alabama Power Plant fire. In one scene from the movie, a physicist Dr. Elliott Lowell played by Donald Hotton states that a China Syndrome event would make "an area the size of Pennsylvania" permanently uninhabitable. Real serious nuclear incidents like Chernobyl and Fukushima are often sited to make people fear the consequences of using nuclear power. However, the consequences are at best poorly communicated and at worst fictitiously inflated to instigate social unrest against nuclear power. There is an article being circulated on Facebook with a title "28 Signs that the (US) West Coast is being absolutely fried with nuclear radiation from Fukushima" which focus on mis-information and fear mongering. Nuclear power and NTR are powerful resources that can open many doors for future prosperity and capability. With great power comes great responsibility. Radiation and its effects need to be better understood, quantified, and communicated. A human mission to mars has its own risks of deep space radiation and is considered a considerable risk at 400 milli-Sieverts per year in deep space and 245 milli-Sieverts per year on the surface of Mars as measured by the Mars Curiosity mission. Although these quantities of ionizing radiation are within the astronaut career limit, it exceeds the yearly average amounts of ionizing radiation. Astronaut crews have experienced these levels of radiation before, but for durations shorter than a year, and a mission to Mars could possibly be 3 years in length. There is also evidence that people can comfortably handle higher levels of ionizing radiation where the radiation occurs naturally like Ramsar, Iran when people can experience 270 milli-Sieverts per year. A risk posture that the development, test, and flight of an NTR will meet opposition from groups who oppose nuclear energy must be likely and the impact can be sever to the effort. Active risk mitigation must be taken for an NTR full-scale development project. The NTR design must take into account safety for transport and off nominal conditions. Nuclear fuel element must consider containment of fission products and Low Enriched Uranium (LEU) that may meet less opposition should be considered for safety and security reasons. Even though testing was conducted on Rover/NERVA safely and successfully in the 60's with exhaust sent heavenward in to open air, modern testing of NTR must consider full containment and no release of ionizing radiation to the public and must meet the current requirement of no more than 0.1 milli-Sieverts per year to the public. 0.1 milli-Sieverts is equivalent to eating one banana or a 20 hour plane flight. Good communication with the public and regulatory agencies will be essential to show that all effort is applied toward protection to the public and astronauts. The inspiring endeavor to put humans on Mars to study the planet, search for life, and learn more about this Solar System will be full of risks but it will be worth it. NTR will be worth the development effort if it allows humans to explore our Solar System.

Kim, Tony↗

Retrofitting Holcim Ste. Genevieve Cement Plant with CO2 Capture Plant Using Air Liquide Cryocap™ FG Technology

The global cement manufacturing industry is a major contributor to carbon dioxide emissions. The International Energy Agency's "Net Zero Emissions by 2050 Scenario" identifies CCS as a major strategy for meeting that goal. This project is among the first attempts to transfer capture technology developed at coal-fired power plants to the cement industry. The main objective of the project is to execute and complete a front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separates 95% of the total CO2 emissions at the Holcim (US) Ste. Genevieve cement manufacturing facility using Air Liquide’s Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology. The Holcim Ste. Genevieve cement plant in Missouri, US, boasts one of the largest single cement production lines in the world, with a capacity of approximately 12,000 t/day. The plant currently uses traditional fuels, namely coal and petcoke. The captured CO2 will be pipeline and geological storage grade. The industrial host site emits approximately 3.0 million tonne CO2/yr. Air Liquide’s Cryocap™ technology has been developed over the last 18+ years for CO2 capture applications. It has been shown to be applicable to a variety of industrial applications (e.g., steel, cement, SMR, Fluidized Catalytic Crackers (FCCs)). Cryocap™ FG consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The project team is led by the Prairie Research Institute at the University of Illinois at Urbana-Champaign. The tasks include: complete FEED study for retrofitting the industrial facility with a carbon capture system to support developing a detailed cost estimate; business case analysis outlining the anticipated revenue and credits if projects was built and operated; technoeconomic analysis (TEA) outlining how capture system achieves DOE capture goals; and life cycle (LCA) analysis demonstrating zero net carbon emissions. The FEED study was successfully completed. This includes completing the process basis of design; preliminary engineering; outside battery limits (OSBL) detailed engineering including a Zero Liquid Discharge (ZLD) wastewater treatment system; inside battery limits (ISBL) detailed engineering [1]. An overall project capital cost estimate within a -20%/+30% accuracy was developed. The major contributors to the Total Plant Cost (TPC), by system, are the costs associated with the Outside Battery Limit (OSBL) section of the plant which includes a new river water intake structure and a Zero Liquid Discharge (ZLD) system. By cost category, the major contributors to the TPC are equipment and subcontractor costs, followed closely by engineering, construction management, home office and contractor fees. The TEA has been created to reflect the findings of the project. It analyzes the economic performance of the Cryocap™ technology by reviewing the estimated capital costs, operating cost, and revenue. The Cost of Capture (COC) associated with the Cryocap™ technology for 95% CO2 capture, when considering NETL 2018 economic assumptions (42/58 debt/equity ratio, 5.15% interest on debt and 1.42% return on equity in real dollars) and 2022 economic assumptions (42/58 debt/equity ratio, 8.82% interest on debt and 4.90% return on equity in real dollars) was found to be much lower than that for the DOE-NETL’s base-line cases. The highest contributors to the COC are annualized capital expenditures (CAPEX) and electricity consumption which can be offset by using lower cost renewable sources. The LCA was conducted using OpenLCA which is an open-source software that is recommended by NETL. The database utilized for this study was a modified version of TRACI 2.1 (developed by the US. Environmental Protection Agency’s National Risk Management Research Laboratory and modified by NETL). The Cryocap™ FG technology does not consume fuels in significant quantities and does not utilize specialized chemical solvents subject to decomposition, such as those utilized in amine-based carbon capture systems. The Cryocap™ FG technology mainly utilizes electricity as its energy input; hence, its calculated emissions are mainly associated with the generation of electricity offsite and are dependent on the energy matrix of the grid at the time of project implementation. The water consumption impact of the Cryocap™ FG is mostly for makeup of the water lost by evaporation in the cooling tower; however, the carbon capture plant will be equipped with a ZLD system to avoid effluent streams and minimize water consumption. The successful construction and operation of this plant based on this study results will provide a means to demonstrate an economically attractive and transformational capture technology that can be used to retrofit existing plants and be deployed at new plants.

01 COAL, LIGNITE, AND PEAT↗

Using FENOSOL{sup TM} Phenolic Foam as a Shock Absorber for Type B Packaging - 17256

Type B and fissile material transportation packages are designed to withstand deformation from dynamic forces experienced during impacts in hypothetical accident conditions. A critical aspect is to ensure the containment system is not breached. The package design normally includes impact limiters made up of a shell filled with energy-absorbing material. Various types of materials are used as energy absorbers, including wood, foam, and honeycomb structures. Synthetic foam is an ideal material for impact limiters; it has isotropic material properties, it acts as a heat insulator during fire conditions, and it maintains structural integrity at high temperatures. In addition, the density of the foam may be controlled during the manufacturing process, allowing the cask designer flexibility to select the right density for each application. The foam properties can be used as inputs for numerical simulations of dynamic impacts. These simulations are a key component of the safety analysis report for Type B transportation casks. Robatel has recently invested in equipment to produce FENOSOL{sup TM} phenolic foam in our factory for use in our cask designs. This acquisition was made jointly between Robatel and the CEA, with Robatel ensuring the industrialization of the product. In the past decade, this foam was successfully integrated into more than 10 European cask designs, and there has been extensive in-laboratory characterization of its properties. FENOSOL{sup TM} has already been accepted by the French Nuclear Safety Authority (ASN) as a shock absorbing material for use in cask designs. Since the acquisition of the phenolic foam production process by Robatel, a new research and development program has been launched to provide more accurate information to our clients, extend the range of application of this foam, and to improve its properties. Robatel has built an extensive database of material characteristics through the use of a universal mechanical tester, a scanning electron microscope, and a nuclear magnetic resonance spectrometer. In addition, Robatel has successfully implemented FENOSOL{sup TM} in two recent cask designs. This included scale model drop testing of a 9 meter drop in three orientations, and a pin puncture drop test. Robatel is in the process of producing FENOSOL{sup TM} samples for testing according to ASTM standards. Various densities will be included in the study. The testing will include duro-meter hardness, specific heat, thermal conductivity, compressive strength and modulus, and tensile strength. Once the testing is complete, Robatel will compile the data in the form of product specification sheets for each density. These information sheets and test reports will be used to validate FENOSOL{sup TM} for use in future impact limiters for the North American Type B cask market. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

22 N HPGP Thruster Life Testing

In the ever-changing paradigm of efficient and capable spacecraft design, scientific missions continue pushing the envelope enabling spacecraft subsystems to deliver effective solutions to meet challenging new mission/spacecraft needs. From an in-space storable liquid chemical propulsion perspective, monopropellant hydrazine has been, and continues to be, a dependable propellant with considerable flight heritage, a variety of engine thrust classes available from multiple vendors, with repeatable and reliable performance. Additionally, the space propulsion industry has learned to successfully handle hydrazine, its regulations, the safety protocols, the personnel protective equipment, and the unique training standards–all requisite for loading spacecraft propulsion systems with toxic hypergolic hydrazine. The question now arises as to “what is next for in-space chemical propulsion?” Further, with the evolution and concrete advancements in innovative in-space green propellant technologies, capable of providing realizable benefits to scientific missions, concern over the reliability and availability of this higher performing and safer to handle class of propellants is waning. As science missions move forward with the potential flight in fusion of High Performance Green Propulsion (HPGP), NASA and its industry partners are working to address any gaps in system reliability, performance, or unique operational considerations. Propellant technology that offers both higher performance and significant reduction in personnel hazards compared to hydrazine presents an attractive propulsion subsystem design opportunity. Increased propulsion subsystem performance can result in lower spacecraft launch mass, larger scientific payloads, or extended on-orbit lifetimes. Mission trades using green propulsion technologies have been documented on multiple NASA Goddard Space Flight Center (GSFC) mission classes, examining various parameters and requirements to support mission architectures in Low Earth Orbit (LEO), High Earth Orbit (HEO), geostationary, lunar, planetary, and Quasi-halo orbit around Sun-Earth Lagrange point (L2). The results of these trade studies show promising, attainable benefits. The perceived programmatic risk of flying a newer propulsion technology has, unfortunately, not outweighed the benefits to date. To take advantage of the improved performance and mitigate programmatic risk, HPGP engines must demonstrate life testing at higher propellant throughputs than have currently been demonstrated. In an effort to proactively address the challenges with technology infusion into a risk-averse community, NASA and the Swedish National Space Agency (SNSA) outlined a collaborative Implementing Arrangement (IA) for the respective agencies to pursue increased HPGP technology maturation. This initial IA effort began in 2013, fresh off the heels of the successful PRISMA HPGP technology demonstration mission. The IA targeted objective is to reduce risk to potential future HPGP missions and fully characterize the LMP-103S propellant and associated engine performance. Over the past eight years, HPGP has flown in propulsion systems on twenty-five(25) spacecraft from seven(7) different Launch Ranges around the globe and on seven (7) different Launch Vehicles. Six(6) of these launches involved multiple loading operations for multiple spacecraft. For U.S. Range operations, nine (9) HPGP systems have been processed at Vandenberg Space Force Base(VSFB):six(6) in 2017, and three (3) in 2018. Six (6) more have been processed at Cape Canaveral Air Force Station (CCAFS)in May 2020, with three (3) systems launched in June 2020 and the remaining three (3) system were left loaded and ready until their launch in August of 2020. Three (3) more systems have been processed at Wallops Flight Facility(WFF)and launched in June 2021. In addition, these propulsion subsystems employed heritage propulsion subsystem component such as valves, filters, and pressure transducers, and have further demonstrated nominal functionality in both diaphragm and Propellant Management Device (PDM) propellant tanks. Based on these successes, HPGP technology continues to be considered for NASA Science Mission Directorate missions at GSFC. The work presented herein represents many years of development and collaborative efforts to successfully align higher performance, low toxicity hydrazine alternatives into scientific missions. NASA GSFC Propulsion Engineering, in collaboration with Bradford ECAPS, has developed mission specific thruster design and testing requirements to establish GSFC’s desired test conditions and firing sequences.In2017, the first flight-like 22N HPGP thruster Engineering Qualification Model (EQM-1)was designed and built by Bradford ECAPS to prove out the thruster design, materials, build process, and test campaign with respect to NASA GSFC critical component and mission requirements. This test program was developed to comprehensively test the thruster, the technology, and ultimately increase the 22N HPGP Technology Readiness Level(TRL). EQM-1was tested to environmental qualification levels prior to hot fire performance testing to represent the relevant end-to-end environment (launch to on-orbit operation)with required margin. This thruster demonstrated steady-state and pulse mode operational capability with propellant thruster throughput up to~53kg.At this throughput level, the EQM-1 engine began to present off-nominal performance and the test campaign was halted to allow for non-destructive testing and identify the root cause for the an omalous performance. Capitalizing on the successful elements of the EQM-1 campaign, an upgraded 22N HPGP EQM-2 has been manufactured by Bradford ECAPS to meet the complete GSFC requirements. The EQM-2 thruster’s test campaign has further demonstrated the robustness of the HPGP propulsion technology and increased the Technology Readiness Level (TRL) by undergoing a full acceptance test program, then proceeding into qualification, including environmental testing (vibration and shock to qualification levels),as well as hot-fire life testing, operating at steady-state and pulse modes with increased propellant thruster throughput to~150kg. The HPGP thruster performance testing enables effective HPGP thruster readiness evaluation to meet NASA candidate mission requirements in the future.

High↗

Dose spread functions in computed tomography: A Monte Carlo study

Purpose: Current CT dosimetry employing CTDI methodology has come under fire in recent years, partially in response to the increasing width of collimated x-ray fields in modern CT scanners. This study was conducted to provide a better understanding of the radiation dose distributions in CT. Methods: Monte Carlo simulations were used to evaluate radiation dose distributions along the z axis arising from CT imaging in cylindrical phantoms. Mathematical cylinders were simulated with compositions of water, polymethyl methacrylate (PMMA), and polyethylene. Cylinder diameters from 10 to 50 cm were studied. X-ray spectra typical of several CT manufacturers (80, 100, 120, and 140 kVp) were used. In addition to no bow tie filter, the head and body bow tie filters from modern General Electric and Siemens CT scanners were evaluated. Each cylinder was divided into three concentric regions of equal volume such that the energy deposited is proportional to dose for each region. Two additional dose assessment regions, central and edge locations 10 mm in diameter, were included for comparisons to CTDI{sub 100} measurements. Dose spread functions (DSFs) were computed for a wide number of imaging parameters. Results: DSFs generally exhibit a biexponential falloff from the z=0 position. For a very narrow primary beam input (<<1 mm), DSFs demonstrated significant low amplitude long range scatter dose tails. For body imaging conditions (30 cm diameter in water), the DSF at the center showed {approx}160 mm at full width at tenth maximum (FWTM), while at the edge the FWTM was {approx}80 mm. Polyethylene phantoms exhibited wider DSFs than PMMA or water, as did higher tube voltages in any material. The FWTM were 80, 180, and 250 mm for 10, 30, and 50 cm phantom diameters, respectively, at the center in water at 120 kVp with a typical body bow tie filter. Scatter to primary dose ratios (SPRs) increased with phantom diameter from 4 at the center (1 cm diameter) for a 16 cm diameter cylinder to {approx}12.5 for a 32 cm diameter cylinder. The SPRs increased dramatically at the center of the phantom compared to the edge. For the three equal area regions, the edge to center SPRs for a 32 cm diameter phantom were {approx}1.8, 3.5, and 6.3, respectively. Conclusions: DSFs demonstrate low amplitude long ranging tails which reach considerable distances in cylindrical phantoms. The buildup that results from these long-ranged tails increases at the center of the field (at z=0) with increasing scan length. The DSF distributions lend a better understanding of the trends in CT dose deposition over a range of relevant imaging parameters. The DSFs as well as other related data are available to interested parties using EPAPS at http://www.aip.org/pubservs/epaps.html.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measuring Radioactivity from Fukushima Daiichi in New Mexico

On March 11, 2011, the Fukushima Daiichi nuclear power plant was damaged by the tsunami that followed the 'Great East Japan Earthquake,' and the reactor subsequently leaked radioactive material. In response, LANL augmented the routine ambient (AIRNET) and stack (Rad-NESHAP) measurements with three high-volume samplers: No.167 at the Old White Rock Fire Station; No.173 at the TA-49 gate, and No.211 at the Los Alamos Medical Center. Previous accidents, such as the Three-Mile-Island accident in 1979 and the Chernobyl accident in 1986, indicated that the most likely releases were (a) the noble gases: krypton and xenon; and (b) the volatile elements: cesium, tellurium, and iodine. At the latitude of Fukushima, the predominant winds across the Pacific Ocean are from west to east, and models predicted that the plume would arrive in the western US on about March 18. By this time the shorter-lived isotopes would have decayed. Therefore, the expected radionuclides were xenon-133, cesium-134, cesium-136, cesium-137, tellurium-132, iodine-131, and iodine-132. As expected, cesium-134, cesium-136, cesium-137, tellurium-132, iodine-131, and iodine-132 were all detected by all three high-volume samplers during March 17-21. The concentrations peaked during the March 24-28 period. After this, concentrations of all nuclides declined. In general, the concentrations were consistent with those measured by the EPA RadNet system and many other monitoring systems throughout the world. At the time of writing, preliminary results from the AIRNET and Rad-NESHAP systems are being reported. More detailed results are described in LA-UR-11-10304 and will be reported in full in the annual environmental report for 2011. All previous releases from nuclear reactors have been dominated by noble gases, primarily krypton and xenon, which are not measured by the high-volume samplers or the AIRNET system. However, in sufficient concentrations these and other fission products would be detected by NEWNET. Consistent with this possibility, all NEWNET detectors recorded an increase of 0.2 {micro}R/h from March 19-1, followed by an additional increase of 0.1 {micro}R/h on March 24 (Figure 1). The consistency of the NEWNET stations is indicated by the error bars, which represent the standard error of the mean of the individual stations. Over the next 10 days, the NEWNET readings declined with approximately the 5-day half life of xenon-133, returning to near normal levels on April 2. After this, any further decrease was masked by high radon concentrations on April 3, by a weather system that moved into New Mexico on April 4, and by rainfall on April 6-9. Furthermore, it is likely that all NEWNET detectors responded to a gradually increasing trend in terrestrial radiation during the month of March as the ground dried out. It is difficult to distinguish the hypothetical effects of xenon-133 from the fluctuations of radon decay products. However, at present we do not have an alternative hypothesis for the sharp increase that was observed in all NEWNET stations from March 19-21. Perhaps some of the increase was caused by radon or terrestrial radiation, in which case the observed increase is an upper limit to that caused by releases from Fukushima. LANL data are consistent with those of the EPA RadNet monitoring system. The EPA has repeatedly stated that 'The levels detected are far below levels of concern.'

CESIUM 134↗

3-D Deep Penetration Neutron Imaging of Thick Absorgin and Diffusive Objects Using Transport Theory

A current area of research interest in national security is to effectively and efficiently determine the contents of the many shipping containers that enter ports in the United States. This interest comes as a result of the 9/11 Commission Act passed by Congress in 2007 that requires 100% of inbound cargo to be scanned by 2012. It appears that this requirement will be achieved by 2012, but as of February of 2009 eighty percent of the 11.5 million inbound cargo containers were being scanned. The systems used today in all major U.S. ports to determine the presence of radioactive material within cargo containers are Radiation Portal Monitors (RPM). These devices generally exist in the form of a gate or series of gates that the containers can be driven through and scanned. The monitors are effective for determining the presence of radiation, but offer little more information about the particular source. This simple pass-fail system leads to many false alarms as many everyday items emit radiation including smoke detectors due to the Americium-241 source contained inside, bananas, milk, cocoa powder and lean beef due to the trace amounts of Potassium-40, and fire brick and kitty litter due to their high clay content which often contains traces of uranium and thorium. In addition, if an illuminating source is imposed on the boundary of the container, the contents of the container may become activated. These materials include steel, aluminum and many agricultural products. Current portal monitors also have not proven to be that effective at identifying natural or highly enriched uranium (HEU). In fact, the best available Advanced Spectroscopic Portal Monitors (ASP) are only capable of identifying bare HEU 70-88% of the time and masked HEU and depleted uranium (DU) only 53 percent of the time. Therefore, a better algorithm that uses more information collected from better detectors about the specific material distribution within the container is desired. The work reported here explores the inverse problem of optical tomography applied to heterogeneous domains. The neutral particle transport equation was used as the forward model for how neutral particles stream through and interact within these heterogeneous domains. A constrained optimization technique that uses Newtons method served as the basis of the inverse problem. Optical tomography aims at reconstructing the material properties using (a) illuminating sources and (b) detector readings. However, accurate simulations for radiation transport require that the particle (gamma and/or neutron) energy be appropriate discretize in the multigroup approximation. This, in turns, yields optical tomography problems where the number of unknowns grows (1) about quadratically with respect to the number of energy groups, G, (notably to reconstruct the scattering matrix) and (2) linearly with respect to the number of unknown material regions. As pointed out, a promising approach could rely on algorithms to appropriately select a material type per material zone rather than G2 values. This approach, though promising, still requires further investigation: (a) when switching from cross-section values unknowns to material type indices (discrete integer unknowns), integer programming techniques are needed since derivative information is no longer available; and (b) the issue of selecting the initial material zoning remains. The work reported here proposes an approach to solve the latter item, whereby a material zoning is proposed using one-group or few-groups transport approximations. The capabilities and limitations of the presented method were explored; they are briefly summarized next and later described in fuller details in the Appendices. The major factors that influenced the ability of the optimization method to reconstruct the cross sections of these domains included the locations of the sources used to illuminate the domains, the number of separate experiments used in the reconstruction, the locations where measurements were collected, the optical thickness of the domain, the amount of signal noise and signal bias applied to the measurements and the initial guess for the cross section distribution. All of these factors were explored for problems with and without scattering. Increasing the number of source and measurement locations and experiments generally was more successful at reconstructing optically thicker domains while producing less error in the image. The maximum optical thickness that could be reconstructed with this method was ten mean free paths for pure absorber and two mean free paths for scattering problems. Applying signal noise and signal bias to the measured fluxes produced more error in the produced image. Generally, Newtons method was more successful at reconstructing domains from an initial guess for the cross sections that was greater in magnitude than their true values than from an initial guess that was lower in magnitude.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗