Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Optimized Test Section for Helium Flow Loop Experiment

Phase 3 of this project uses the knowledge and techniques gained from Phase 1 and Phase 2. The first outcome of Phase 3 is a new test section which can be manufactured and tested in the Helium Flow Loop Experiment to verify the results of the optimization study. The second outcome of Phase 3 is analyzing the features of this design and determining its performance under simulated TBM conditions: heat flux, pressure, mass flow rate, one-sided and volumetric heating. This will be accomplished by first using the results from the Phase 1 analyses and then applying the optimization strategy from Phase This phase uses the STAR-CCM+ Design Manager tool to apply the optimization strategy to the Helium Flow Loop Experiment (HFLE). The optimization algorithm used by the Design Manager tool is Simultaneous Hybrid Exploration that is Robust, Progressive, and Adaptive (SHERPA search algorithm). In addition to demonstrating the optimization features, a simple parameter sweep is also included in this phase. This report details the applied single objective optimization.

42 ENGINEERING↗

High-Flow Jet Exit Rig Designed and Fabricated

The High-Flow Jet Exit Rig at the NASA Glenn Research Center is designed to test single flow jet nozzles and to measure the appropriate thrust and noise levels. The rig has been designed for the maximum hot condition of 16 lbm/sec of combustion air at 1960 R (maximum) and to produce a maximum thrust of 2000 lb. It was designed for cold flow of 29.1 lbm/sec of air at 530 R. In addition, it can test dual-flow nozzles (nozzles with bypass flow in addition to core flow) with independent control of each flow. The High- Flow Jet Exit Rig was successfully fabricated in late 2001 and is being readied for checkout tests. The rig will be installed in Glenn's Aeroacoustic Propulsion Laboratory. The High-Flow Jet Exit Rig consists of the following major components: a single component force balance, the natural-gas-fueled J-79 combustor assembly, the plenum and manifold assembly, an acoustic/instrumentation/seeding (A/I/S) section, a table, and the research nozzles. The rig will be unique in that it is designed to operate uncooled. The structure survives the 1960 R test condition because it uses carefully selected high temperature alloy materials such as Hastelloy-X. The lower plenum assembly was designed to operate at pressures to 450 psig at 1960 R, in accordance with the ASME B31.3 piping code. The natural gas-fueled combustor fires directly into the lower manifold. The hot air is directed through eight 1-1/2-in. supply pipes that supply the upper plenum. The flow is conditioned in the upper plenum prior to flowing to the research nozzle. The 1-1/2-in. supply lines are arranged in a U-shaped design to provide for a flexible piping system. The combustor assembly checkout was successfully conducted in Glenn's Engine Component Research Laboratory in the spring of 2001. The combustor is a low-smoke version of the J79 combustor used to power the F4 Phantom military aircraft. The natural gas-fueled combustor demonstrated high-efficiency combustion over a wide range of operating conditions. This wide operating envelope is required to support the testing of both single- and dual-flow nozzles. Key research goals include providing simultaneous, highly accurate acoustic, flow, and thrust measurements on jet nozzle models in realistic flight conditions, as well as providing scaleable acoustic results. The High-Flow Jet Exit Rig is a second-generation high-flow test rig. Improvements include cleaner flow with reduced levels of particulate, soot, and odor. Choked-flow metering is required with plus or minus 0.25-percent accuracy. Thrust measurements from 0 to 2000 lbf are required with plus or minus 0.25-percent accuracy. Improved acoustics will be achieved by minimizing noise through large pipe bend radii, lower internal flow velocities, and microdrilled choke plates with thousands of 0.040-in.- diameter holes.

Buehrle, Robert J.↗

A new design concept for indraft wind-tunnel inlets with application to the national full-scale aerodynamic complex

The present inlet design concept for an indraft wind tunnel, which is especially suited to applications for which a specific test section flow quality is required with minimum inlet size, employs a cascade or vaneset to control flow at the inlet plane, so that test section total pressure variation is minimized. Potential flow panel methods, together with empirical pressure loss predictions, are used to predict inlet cascade performance. This concept has been used to develop an alternative inlet design for the 80 x 120-ft wind tunnel at NASA Ames Research Center. Experimental results show that a short length/diameter ratio wind tunnel inlet furnishing atmospheric wind isolation and uniform test section flow can be designed.

Ross, James C.↗

Studies with the USF/NASA toxicity screening test method - Effect of air flow and effect of fabric dye

One sample each of commercial polyurethane and polychloroprene flexible foams were evaluated using the USF/NASA toxicity screening test method. Air flow rates of 0, 0.16, 16, and 48 ml/sec were used to determine the effect of air flow on relative toxicity. Time to first sign of incapacitation and time to death were substantially reduced with both polyurethane and polychloroprene flexible foams by the introduction of 16 to 48 ml/sec air flow. The relative toxicity rankings of these materials were not altered by changes in air flow. Under these test conditions, the polyurethane foam consistently appeared more toxic than the polychloroprene foam. Samples of six different colors from the same fabric were evaluated separately, using the USF/NASA toxicity screening test method, to determine the effect of fabric dye, if any. The material was an upholstery fabric, consisting of 46 percent cotton, 33 percent wool, and 21 percent nylon. There appeared to be no significant effect of fabric dye on relative toxicity, for this material under these test conditions.

Hilado, C. J.↗

Space Launch System Base Heating Test: Environments and Base Flow Physics

The NASA Space Launch System (SLS) vehicle is composed of four RS-25 liquid oxygen-hydrogen rocket engines in the core-stage and two 5-segment solid rocket boosters and as a result six hot supersonic plumes interact within the aft section of the vehicle during flight. Due to the complex nature of rocket plume-induced flows within the launch vehicle base during ascent and a new vehicle configuration, sub-scale wind tunnel testing is required to reduce SLS base convective environment uncertainty and design risk levels. This hot-fire test program was conducted at the CUBRC Large Energy National Shock (LENS) II short-duration test facility to simulate flight from altitudes of 50 kft to 210 kft. The test program is a challenging and innovative effort that has not been attempted in 40+ years for a NASA vehicle. This paper discusses the various trends of base convective heat flux and pressure as a function of altitude at various locations within the core-stage and booster base regions of the two-percent SLS wind tunnel model. In-depth understanding of the base flow physics is presented using the test data, infrared high-speed imaging and theory. The normalized test design environments are compared to various NASA semi-empirical numerical models to determine exceedance and conservatism of the flight scaled test-derived base design environments. Brief discussion of thermal impact to the launch vehicle base components is also presented.

Mehta, Manish↗

Investigation of the Flow-Induced Vibration in the E2 Test Facility

An investigation of flow induced vibration due to coupling between the fluid flow and the propellants lines (LOX and RP-1) was performed. Various flow rate conditions were studied to check whether flow induced vibration was possible due to vortex shedding in both valves and pipe lines. Resonance test was conducted for all segments of the LOX-feedline for the preburner under test. In addition, critical values of frequency and velocity are calculated using a mass damping model. A simple chart characterizing the relation between frequency and velocity is developed for each component; i.e. propellant lines, valves and flow meters. It was found that flow induced vibration occurs for various segments with flow rates of 113 lb/s, 275 lb/s and 40 lb/s. Even more interesting using critical conditions for buckling, it was found that the valve or pipe may collapse for a flow rate of 275 lb/s and valve height of 10% of pipe diameter. Furthermore, two models for the acoustic pressure acting on the segments particularly for the valve are proposed.

Castillo, Luciano↗

Investigation of the Flow-Induced Vibration in the E2 Test Facility

An investigation of flow induced vibration due to coupling between the fluid flow and the propellants lines (LOX and RP-1) was performed. Various flow rate conditions were studied to check whether flow induced vibration was possible due to vortex shedding in both valves and pipe lines. Resonances test was conducted for all segments of the LOX-feedline for the preburner under test. In addition, critical values of frequency and velocity are calculated using a mass damping model. A simple chart characterizing the relation between frequency and velocity is developed for each component; i.e. propellant lines, valves and flow meters. It was found that flow induced vibration occurs for various segments with flow rates of 113 1b/s, 275 lb/s and 40 lb/s. Even more interesting using critical conditions for buckling, it was found that the valve or pipe may collapse for a flow rate of 275 lb/s and valve height of 10% of pipe diameter. Furthermore, two models for the acoustic pressure acting on the segments particularly for the valve are proposed.

Castillo, Luciano↗

Development of an Axisymmetric Afterbody Test Case for Turbulent Flow Separation Validation

As identified in the CFD Vision 2030 Study commissioned by NASA, validation of advanced RANS models and scale-resolving methods for computing turbulent flows must be supported by improvements in high-quality experiments designed specifically for CFD implementation. A new test platform referred to as the Axisymmetric Afterbody allows for a range of flow behaviors to be studied on interchangeable afterbodies while facilitating access to higher Reynolds number facilities. A priori RANS computations are reported for a risk-reduction configuration to demonstrate critical variation among turbulence model results for a given afterbody, ranging from barely-attached to mild separated flow. The effects of body nose geometry and tunnel-wall boundary condition on the computed afterbody flow are explored to inform the design of an experimental test program.

Disotell, Kevin J.↗

Performance characteristics of two annular dump diffusers using suction-stabilized vortex flow control

Test results are described for two abrupt area change annular diffusers with provisions for maintaining suction stabilized toroidal vortices at the area discontinuity. Both diffusers had an overall area ratio of 4.0 with the prediffuser area ratio being 1.18 for diffuser A and 1.4 for diffuser B. Performance was evaluated at near atmospheric pressure and temperature for a range of inlet Mach numbers from 0.18 to 0.41 and suction rates from 0 to 18%. Static pressure recovery improved significantly as the suction rate was increased to approximately 11%. Results obtained with diffuser A were superior to that obtained with diffuser B. Flat radial profiles of exit velocity were not obtained since the flow showed preferential hub or tip attachment at moderate suction rates. At high suction rates the diffuser exit flow became circumferentially nonuniform and unstable.

Juhasz, A. J.↗

Blockage and flow studies of a generalized test apparatus including various wing configurations in the Langley 7-inch Mach 7 Pilot Tunnel

A 1/12th scale model of the Curved Surface Test Apparatus (CSTA), which will be used to study aerothermal loads and evaluate Thermal Protection Systems (TPS) on a fuselage-type configuration in the Langley 8-Foot High Temperature Structures Tunnel (8 ft HTST), was tested in the Langley 7-Inch Mach 7 Pilot Tunnel. The purpose of the tests was to study the overall flow characteristics and define an envelope for testing the CSTA in the 8 ft HTST. Wings were tested on the scaled CSTA model to select a wing configuration with the most favorable characteristics for conducting TPS evaluations for curved and intersecting surfaces. The results indicate that the CSTA and selected wing configuration can be tested at angles of attack up to 15.5 and 10.5 degrees, respectively. The base pressure for both models was at the expected low level for most test conditions. Results generally indicate that the CSTA and wing configuration will provide a useful test bed for aerothermal pads and thermal structural concept evaluation over a broad range of flow conditions in the 8 ft HTST.

Albertson, C. W.↗

Analysis of Transient Groundwater Flow Near the Cheshire Test at Pahute Mesa, Nevada National Security Site

This report focuses on analysis and determination of the causes of transient water levels measured between 1964 and 2017 near the Cheshire underground nuclear test, which was detonated on February 14, 1976 in Area 20 (USDOE, 2015) of the Pahute Mesa (PM) testing areas of the Nevada National Security Site (NNSS) located in southern Nevada (Figure 1). Transient water levels near Cheshire indicate influences of a water-production well and yet-unexplained water level rise attributed to testing effects (Jackson and Fenelon, 2018; Jackson et al. 2021). Transient groundwater flow is relevant to the implementation of the hydrologic source term (HST), which prescribes the quantity and release rates of radionuclide source terms to be applied at individual test locations in assessment of regional-scale radionuclide transport (Carle and Tompson, 2021; Carle et al., 2021), as previously investigated for NNSS testing areas at PM (Pawloski et al., 2001), Frenchman Flat (Carle et al, 2007), Yucca Flat (Mcnab, 2009; Tompson, 2009), and Rainier Mesa (Carle, 2011; Tompson et al., 2011).

54 ENVIRONMENTAL SCIENCES↗

Analysis of Transient Groundwater Flow Near the Cheshire Test at Pahute Mesa, Nevada National Security Site

This report focuses on analysis and determination of the causes of transient water levels measured between 1964 and 2017 near the Cheshire underground nuclear test, which was detonated on February 14, 1976 in Area 20 (USDOE, 2015b) of the Pahute Mesa (PM) testing areas of the Nevada National Security Site (NNSS) located in southern Nevada (Figure 1). Transient water levels near Cheshire indicate influences of a water-production well and yet-unexplained water level rise attributed to testing effects (Jackson and Fenelon, 2018; Jackson et al. 2021). Transient groundwater flow is relevant to the implementation of the hydrologic source term (HST), which prescribes the quantity and release rates of radionuclide source terms to be applied at individual test locations in assessment of regional-scale radionuclide transport (Carle and Tompson, 2021; Carle et al., 2021), as previously investigated for NNSS testing areas at PM (Pawloski et al., 2001), Frenchman Flat (Carle et al, 2007), Yucca Flat (Carle et al., 2009; Mcnab, 2009; Tompson et al., 2009), and Rainier Mesa (Carle, 2011; Tompson et al., 2011).

54 ENVIRONMENTAL SCIENCES↗

A Comparison of Impedance Eduction Test Rigs with Different Flow Profiles

The experimental characterization of acoustic liners applied for turbofan engines has been in the spotlight of the community for the last few decades. In general, such characterization is done by measurements of the liner acoustic impedance using different techniques in conditions as close as possible to those encountered in turbofan engines. Although a great amount of work has been published related to these techniques, few comparisons between different experimental setups using identical samples are available. The goal of the present study is to provide a comparison between educed acoustic impedances for two nominally identical liner samples in theUFSC Impedance Test Rig and the NASA Langley Research Center Grazing Flow ImpedanceTube (GFIT). Due to the geometrical differences between the test rigs, it is possible to consider the effect of different grazing flow profiles on the educed impedance. Impedance measurements between the two facilities show similar results in absence of grazing flow, while different ones when the grazing flow is present. Results are presented with both test rigs targeted to two different conditions: (i) same centerline Mach number and; (ii) same average Mach number.Both comparisons suggest a higher acoustic resistance obtained with the UFSC Impedance TestRig. A comparison using semi-empirical predictive models was also conducted. The results suggest that the main source for the observed difference is the grazing flow profile, represented by its boundary layer displacement thickness.

impedance↗

A Comparison of Impedance Eduction Test Rigs with Different Flow Profiles

The experimental characterization of acoustic liners applied for turbofan engines has been in the spotlight of the community for the last few decades. In general, such characterization is done by measurements of the liner acoustic impedance using different techniques in conditions as close as possible to those encountered in turbofan engines. Although a great amount of work has been published related to these techniques, few comparisons between different experimental setups using identical samples are available. The goal of the present study is to provide a comparison between educed acoustic impedances for two nominally identical liner samples in theUFSC Impedance Test Rig and the NASA Langley Research Center Grazing Flow ImpedanceTube (GFIT). Due to the geometrical differences between the test rigs, it is possible to consider the effect of different grazing flow profiles on the educed impedance. Impedance measurements between the two facilities show similar results in absence of grazing flow, while different ones when the grazing flow is present. Results are presented with both test rigs targeted to two different conditions: (i) same centerline Mach number and; (ii) same average Mach number.Both comparisons suggest a higher acoustic resistance obtained with the UFSC Impedance TestRig. A comparison using semi-empirical predictive models was also conducted. The results suggest that the main source for the observed difference is the grazing flow profile, represented by its boundary layer displacement thickness.

impedance↗

4D Electrical Resistivity Imaging of Stress Perturbations Induced During High–Pressure Shear Stimulation Tests

Fluid flow through fractured media is typically governed by the distribution of fracture apertures, which are in turn governed by stress. Consequently, understanding subsurface stress is critical for understanding and predicting subsurface fluid flow. Although laboratory–scale studies have established a sensitive relationship between effective stress and bulk electrical conductivity in crystalline rock, that relationship has not been extensively leveraged to monitor stress evolution at the field scale using electrical or electromagnetic geophysical monitoring approaches. In this paper we demonstrate the use time–lapse 3–dimensional (4D) electrical resistivity tomography to image perturbations in the stress field generated by pressurized borehole packers deployed during shear–stimulation attempts in a 1.25 km deep metamorphic crystalline rock formation.

58 GEOSCIENCES↗

Calculation of three-dimensional laminar boundary-layer flows.

Accuracy tests have been made of the approximation, proposed recently by Wang (1971), which reduces the computation of three-dimensional, laminar, compressible, boundary-layer equations to the problem of solving two-dimensional type boundary-layer equations. The tests were made by a comparison of the results achieved using Wang's method with a fully three-dimensional boundary-layer calculation. Results of the comparison are tabulated and are found to be in good agreement.

Fillo, J. A.↗

System for measuring transients in fluid flow

When test valve is actuated, piston is moved by pressurized fluid, and displacement is monitored by electro-optical tracking system and recorded by oscilloscope camera. Electro-optical monitor produces output voltage proportional to displacement of piston.

Pearson, D. J.↗