Air Pollutant Emissions and Regulatory Implications of a Biorefinery Co-Processing Bio-Oil in a Petroleum Refinery: Preprint

Pyrolysis oil, often referred to as bio-oil when derived from biomass through a fast pyrolysis process, has attracted considerable attention because of the high carbonaceous matter and high heating value compared to the original biomass. Pyrolysis oil provides a viable link between the agriculture/forestry and (petro-) chemical industry. Utilizing existing fossil fuel infrastructure by introducing bio-oil in petroleum refineries to produce renewable hydrocarbon fuels (i.e., repurposing existing assets) is appealing due to its relatively low capital requirement. Our analysis examined the air pollutant emissions for a biorefinery utilizing an ex situ catalytic fast pyrolysis process to produce raw bio-oil, with a design capacity of 2,000 dry metric tons of biomass per day. Such a biorefinery is capable of providing sufficient bio-oil to a 4,200 barrels per day capacity of fluidized catalytic cracking unit if the bio-oil is co-processed at 5% (by volume) feed rate. This research is focused on understanding the potential air pollutant regulatory and permitting implications for a refinery co-processing 5% bio-oil with 95% vacuum gas oil in a fluidized catalytic cracking unit for two scenarios: the first case assumes that an ex situ biorefinery is collocated with a petroleum refinery, and the second one assumes that a petroleum refinery will receive bio-oil from a stand-alone biorefinery. We estimated the potential-to-emit values for 4 biorefinery and FCC sizes and assessed technically feasible emission control options that could help to avoid being subject to prevention of significant deterioration requirements due to petroleum refinery modifications to co-process bio-oil. This research fills gaps and overcomes barriers related to air permitting requirements for co-processing bio-oil in existing refineries for various stakeholders. The insights gained from this analysis can facilitate decision making and help expedite permitting processes for petroleum refineries, which seek opportunities to produce lower carbon fuels in their existing infrastructure.

09 BIOMASS FUELS↗

Air Pollutant Emissions and Regulatory Implications of a Biorefinery Co-Processing Bio-Oil in a Petroleum Refinery

Pyrolysis oil, often referred to as bio-oil when derived from biomass through a fast pyrolysis process, has attracted considerable attention because of the high carbonaceous matter and high heating value compared to the original biomass. Pyrolysis oil provides a viable link between the agriculture/forestry and (petro-) chemical industry. Utilizing existing fossil fuel infrastructure by introducing bio-oil in petroleum refineries to produce renewable hydrocarbon fuels (i.e., repurposing existing assets) is appealing due to its relatively low capital requirement. Our analysis examined the air pollutant emissions for a biorefinery utilizing an ex situ catalytic fast pyrolysis process to produce raw bio-oil, with a design capacity of 2,000 dry metric tons of biomass per day. Such a biorefinery is capable of providing sufficient bio-oil to a 4,200 barrels per day capacity of fluidized catalytic cracking unit if the bio-oil is co-processed at 5% (by volume) feed rate. This research is focused on understanding the potential air pollutant regulatory and permitting implications for a refinery co-processing 5% bio-oil with 95% vacuum gas oil in a fluidized catalytic cracking unit for two scenarios: the first case assumes that an ex situ biorefinery is collocated with a petroleum refinery, and the second one assumes that a petroleum refinery will receive bio-oil from a stand-alone biorefinery. We estimated the potential-to-emit values for 4 biorefinery and FCC sizes and assessed technically feasible emission control options that could help to avoid being subject to prevention of significant deterioration requirements due to petroleum refinery modifications to co-process bio-oil. This research fills gaps and overcomes barriers related to air permitting requirements for co-processing bio-oil in existing refineries for various stakeholders. The insights gained from this analysis can facilitate decision making and help expedite permitting processes for petroleum refineries, which seek opportunities to produce lower carbon fuels in their existing infrastructure.

09 BIOMASS FUELS↗

Pulverized fuel-oxygen burner

A burner assembly combines oxygen and fuel to produce a flame. The burner assembly includes an oxygen supply tube adapted to receive a stream of oxygen and a solid fuel conduit arranged to extend through the oxygen tube to convey a stream of fluidized, pulverized, solid fuel into a flame chamber. Oxygen flowing through the oxygen supply tube passes generally tangentially through a first set of oxygen-injection holes formed in the solid fuel conduit and off-tangentially from a second set of oxygen-injection holes formed in the solid fuel conduit and then mixes with fluidized, pulverized, solid fuel passing through the solid fuel conduit to create an oxygen-fuel mixture in a downstream portion of the solid fuel conduit. This mixture is discharged into a flame chamber and ignited in the flame chamber to produce a flame.

Taylor, Curtis↗

Improved Impregnation Techniques for CuO-based CLOU Oxygen Carriers

A review of scalable impregnation techniques for copper-based chemical looping with oxygen uncoupling (CLOU) is presented in this report, followed by a method for improved metal-support interaction. Both incipient wetness and wet impregnation techniques are reviewed for SiC and SiO2 supports. Physical and chemical characterization, including crush strength, BET, SEM, ICP-MS, and XRD were performed. Attrition and agglomeration were analyzed in a small fluidized bed up to 975°C. Carriers that met a quality of impregnation threshold that were deemed worthy of further exploration. Two strategies were identified as feasible for synthetic Cu-based oxygen carriers. Inexpensive support with high processing costs, and expensive support with low processing costs. For high surface area SiO2, the novel Cu precursor tetraamine copper nitrate (TACN) was identified that improved Cu-support interaction to improve dispersion and impregnation quality. Fluidized bed results demonstrated agglomeration and attrition resistance in OC greater than 40wt% OC.

O'Malley, Kyle↗

Application of MP-PIC on Dual Interconnected Chemical Looping Cold Flow System: Validation Process with Hydrodynamic Experiments

Chemical looping with oxygen uncoupling (CLOU) is a promising carbon capture technologies, that utilizes a dual fluidized bed interconnected by loopseals to selectively separate oxygen from ambient air. This study validated Barracuda-VR® hydrodynamic simulations of dual circulating fluidized bed. The experiments were run on a scaled-down cold-flow unit of a 100 kW dual reactor to find the quantities of interest: circulation rate, bed mass location distribution, and pressure profile. The numerical parameters of time step and grid resolution were studied to find the numeric uncertainty for the quantities of interest. The scenario parameters of flowrates, particle densities, and particle voidage were studied. The uncertainty from the model parameters of tangent-to-wall, drag multiplier, and stress model were studied. Simulation and experimental results matched over some of the parameters studied. These can be used to scale the system back to the 100 kW dual reactor and to a larger system.

Hamilton, Matthew A↗

Method for coating ultrafine particles, system for coating ultrafine particles

The invention provides a method for dispersing particles within a reaction field, the method comprising confining the particles to the reaction field using a standing wave. The invention also provides a system for coating particles, the system comprising a reaction zone; a means for producing fluidized particles within the reaction zone; a fluid to produce a standing wave within the reaction zone; and a means for introducing coating moieties to the reaction zone. The invention also provides a method for coating particles, the method comprising fluidizing the particles, subjecting the particles to a standing wave; and contacting the subjected particles with a coating moiety.

25 ENERGY STORAGE↗

Reduction of Ultrafine Hematite for a Spouting Bed Chemical Looping Process - Presentation

Chemical looping combustion research has been a topic of great interest since the mid-1990s, although the concept can be traced much further back. It is a combustion technology for fuel utilization that uses a two-reactor system to produce a carbon free effluent stream from the air reactor and a carbon dioxide rich stream from the fuel reactor with oxygen shuttled between the reactors with an oxygen carrier. Chemical looping combustion has been studied extensively because of this inherent separation of the carbon dioxide combustion product from the atmospheric nitrogen over that past 25 years with hundreds of research papers and tens of books. The oxygen carrier is, in general, a solid such as naturally occurring hematite or an engineered carrier like a copper and iron oxide supported on alumina. System technical and economic research activities conducted at the National Energy Technology Laboratory have shown that the costs associated with the carrier, initial and replacement, are a significant factor in the economic viability of the technology. To overcome this economic challenge, the work reported on in this paper investigates the use of a waste iron oxide as the chemical looping oxygen carrier. This waste material is quite unique as it has a particle size of 0.7 um. Given the particle size, the reactions are quite fast. However, the development of a contactor reactor to mix the fuel with the carrier is a fluidization challenge as the material is a Geldart group C material and highly cohesive. Normally, Geldart group C materials are fluidized with either a vibrating bed. This technique is acceptable for low temperature pharmaceuticals production but does not lend itself to much larger reactors used for power production or operation at temperatures in the order of 1100 to 1200 C. Therefore, a hydrodynamic solution was needed to break up the cohesive structures to replace the vibration. In this instance, it was hypothesized that a spouting bed of large Geldart group B or Geldart group D particles could provide the necessary energy to break up the cohesive structures of the Geldart group C material. This paper presents the reduction performance for this novel carrier material in a laboratory spouting bed reactor.

Breault, Ronald↗

Successes and Challenges of the Integrated Waste Treatment Unit's 50-Day Demonstration Run - 20151

The Integrated Waste Treatment Unit (IWTU) has been tasked with using steam reforming technology to treat 3.4 million liters (900,000 gallons) of radioactive sodium-bearing waste (SBW) at the Idaho National Laboratory (INL). The project has been hampered by a number of processing issues associated with process equipment during simulant testing, with the two main issues involving the fluidizing gas distribution system in the main reactor vessel, the denitration mineralization reformer (DMR), and high differential pressures in the main filter vessel, the process gas filter (PGF). Following the replacement of the fluidizing gas distribution system in the DMR, a successful 30-day demonstration run was performed that revealed unacceptable bridging in the filter bundles of the PGF. The bundles were replaced with new ones, and a 50-day demonstration run was performed. The main purpose of this run was to operate the IWTU over a range of operating conditions. Overall, the run was a success; however, there were multiple challenges that arose from the run. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Post-Combustion and Pre-Combustion CO2 Capture Solid Sorbents

Combustion of fossil fuels is one of the major sources of the greenhouse gas CO2. Pressure swing adsorption/sorption (PSA/PSS) and temperature swing adsorption/sorption (TSA/TSS) are some of the potential techniques that could be utilized for removal of CO2 from fuel gas streams. It is very important to develop sorbents to remove CO2 from fuel gas streams that are applicable for a wide range of temperatures. NETL researchers have developed novel CO2 capture sorbents for low, moderate, and high temperature applications. A novel liquid impregnated solid sorbent was developed for CO2 removal in the temperature range of ambient to 60 °C. The sorbent is regenerable at 60 – 80 °C. The sorbent formulations were prepared to be suitable for various reactor configurations (i.e., fixed and fluidized bed). Minimum fluidization gas velocities were also determined. Multi-cycle tests conducted in an atmospheric bench scale reactor with simulated flue gas indicated that the sorbent retains its CO2 sorption capacity with a CO2 removal efficiency of approximately 99% and was unaffected by presence of water vapor. The sorbent was subsequently commercially prepared by Süd Chemie to determine the viability of the sorbent for mass production. Subsequent testing showed that the commercially-synthesized sorbent possesses the same properties as the lab-synthesized equivalent. An innovative solid sorbent containing mixture of alkali earth and alkali compounds was developed for CO2 removal at 200 – 315°C from high pressure gas streams suitable for IGCC systems. The sorbent showed very high capacity for CO2 removal from a gas streams containing 28% CO2 at 200 °C and at 20 atm during a lab scale reactor test. This sorbent can be regenerated at 20 atm and at 375 °C utilizing a gas stream containing steam. High pressure enhanced the CO2 sorption process. Bench scale testing showed consistent capacities and regenerability. A unique high temperature solid sorbent was developed for CO2 capture at temperatures of 500 – 700°C. Bench scale testing of the sorbent yielded very high CO2 capture capacity from a gas stream containing 10% CO2, 30% H2, 15% H2O, and 25% He. Regeneration of the sorbent is possible at 800 – 900 °C.

COAL↗

Prediction of hydrodynamic properties of mixed-particle systems and theoretical analysis of loop pressure profile in a CFB unit

The hydrodynamic behaviors of mixed system of particles were investigated in a circulating fluidized bed (CFB) unit consisting of fast column (riser) with an inner diameter of 0.1016 m and a height of 5.62 m. Particle mixtures containing a Geldart group-A-like fluid catalytic cracking (FCC) catalyst with group-B-like sand and iron ore with coal were used to study the hydrodynamic features including static pressure, voidage, and loop pressure profile. The mixed system consisting of FCC catalyst and sand contained 20, 50, and 80 mass % sand, and the coal-iron ore mixture contained 80 mass % coal. The superficial air velocity ranged between 2.01 and 4.681 m/s, and the corresponding mass fluxes were 12.5-50 kg/(m{sup 2} s). A comparison of the available experimental values for static pressure profiles at different operating conditions for mixed-particle systems shows good agreement with those predicted from the single-particle systems. Using experimental data on the loop pressure balance, a simplified theoretical analysis was performed to predict the pressure profile in the CFB loop. The deviations between the two sets of values are within reasonable limits of accuracy.

01 COAL, LIGNITE, AND PEAT↗

Bed inventory overturn in a circulating fluid bed riser with pant-leg structure

The special phenomenon, nominated as bed inventory overturn, in circulating fluid bed (CFB) riser with pant-leg structure was studied with model calculation and experimental work. A compounded pressure drop mathematic model was developed and validated with the experimental data in a cold experimental test rig. The model calculation results agree well with the measured data. In addition, the intensity of bed inventory overturn is directly proportional to the fluidizing velocity and is inversely proportional to the branch point height. The results in the present study provide significant information for the design and operation of a CFB boiler with pant-leg structure. 15 refs., 10 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Analysis of mass loss of a coal particle during the course of burning in a flow of inert material

This paper is an attempt to explain the role of erosion during the process of coal combustion in a circulating fluidized bed. Different kinds of carbon deposits found in Poland, both bituminous as well as lignite with the particle of 10 mm in diameter were the subject of the research. According to many publications it is well known that erosion plays a significant role in coal combustion, by changing its mechanism as well as generating an additional mass loss of the mother particle. The purpose of this research was to determine the influence of an inert material on an erosive mass loss of a single coal particle burning in a two-phase flow. The determination of the influence of a coal type, the rate of flow of inert material and the temperature inside the furnace on the erosive mass loss of burning coal particle was also taken into consideration. The results obtained indicate that the velocity of the erosive mass loss depends on the chemical composition and petrographic structure of burning coal. The mechanical interaction of inert and burning coal particles leads to the shortening of the period of overall mass loss of the coal particle by even two times. The increase in the rate of flow of the inert material intensifies the generation of mass loss by up to 100%. The drop in temperature which slows down the combustion process, decreases the mass loss of the coal particle as the result of mechanical interaction of the inert material. As was observed, the process of percolation plays a significant role by weakening the surface of the burning coal. (author)

01 COAL, LIGNITE, AND PEAT↗

Innovative Method Using Magnetic Particle Tracking to Measure Solids Circulation in a Spouted Bed

We describe an innovative method for measuring particle motion inside spouted fluidized beds. The method uses a magnetic tracer particle, which follows the bulk particle flow and is continuously tracked by multiple magnetic field detectors located outside the bed. We analyze signals from the detectors to determine the tracer position at each instant in time. From statistical analysis of the tracer trajectory, characteristic measures of the bulk particle flow, such as the average recirculation frequency, can be determined as a function of operating conditions. For experiments with a range of particle sizes and densities in a 3.9-cm-diameter spouted bed, we find that average solids recirculation rates correlate with excess velocity (superficial minus minimum spouting velocity), particle density, and bed depth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of THOR TM Mineralized Waste Forms (Granular and Monolith) for the DOE Advanced Remediation Technologies (ART) Phase 2 Project

The U.S. Department of Energy's (DOE) Office of River Protection (ORP) is responsible for the retrieval, treatment, immobilization, and disposal of Hanford's tank waste. Currently there are approximately 56 million gallons of highly radioactive mixed wastes awaiting treatment. A key aspect of the River Protection Project (RPP) cleanup mission is to construct and operate the Waste Treatment and Immobilization Plant (WTP). The WTP will separate the tank waste into high-level and low-activity waste (LAW) fractions, both of which will subsequently be vitrified. The projected throughput capacity of the WTP LAW Vitrification Facility is insufficient to complete the RPP mission in the time frame required by the Hanford Federal Facility Agreement and Consent Order, also known as the Tri-Party Agreement (TPA), i.e. December 31, 2047. Therefore, Supplemental Treatment is required both to meet the TPA treatment requirements as well as to more cost effectively complete the tank waste treatment mission. The Supplemental Treatment chosen will immobilize that portion of the retrieved LAW that is not sent to the WTP's LAW Vitrification facility into a solidified waste form. The solidified waste will then be disposed on the Hanford site in the Integrated Disposal Facility (IDF). In addition, the WTP LAW Vitrification facility off-gas condensate known as WTP Secondary Waste (WTP-SW) will be generated and enriched in volatile components such as Cs-137, I-129, Tc-99, Cl, F, and SO 4 that volatilize at the vitrification temperature of 1150°C in the absence of a continuous cold cap. The current waste disposal path for the WTP-SW is to recycle it to the supplemental LAW treatment to avoid a large steady state accumulation in the pretreatment-vitrification loop. Fluidized Bed Steam Reforming (FBSR) offers a moderate temperature (700-750°C) continuous method by which LAW and/or WTP-SW wastes can be processed irrespective of whether they contain organics, nitrates, sulfates/sulfides, chlorides, fluorides, volatile radionuclides or other aqueous components. The FBSR technology can process these wastes into a crystalline ceramic (mineral) waste form. The mineral waste form that is produced by co-processing waste with kaolin clay in an FBSR process has been shown to be as durable as LAW glass. Monolithing of the granular FBSR product, which is one of the objectives of this current study, is being investigated to prevent dispersion during transport or burial/storage but is not necessary for performance. FBSR testing of a Hanford LAW simulant and a WTP-SW simulant at the pilot scale was performed by THOR Treatment Technologies, LLC at Hazen Research Inc. in April/May 2008. The Hanford LAW simulant was the Rassat 68 tank blend and the target concentrations for the LAW was increased by a factor of 10 for Sb, As, Ag, Cd, and Tl; 100 for Ba and Re (Tc surrogate); 1,000 for I; and 254,902 for Cs based on discussions with the DOE field office and the environmental regulators and an evaluation of the Hanford Tank Waste Envelopes A, B, and C. It was determined through the evaluation of the actual tank waste metals concentrations that some metal levels were not sufficient to achieve reliable detection in the off-gas sampling. Therefore, the identified metals concentrations were increased in the Rassat simulant processed by TTT at HRI to ensure detection and enable calculation of system removal efficiencies, product retention efficiencies, and mass balance closure without regard to potential results of those determinations or impacts on product durability response such as Toxicity Characteristic Leach Procedure (TCLP). A WTP-SW simulant based on melter off-gas analyses from Vitreous State Laboratory (VSL) was also tested at HRI in the 15-inch diameter Engineering Scale Test Demonstration (ESTD) dual reformer at HRI in 2008. The target concentrations for the Resource Conservation and Recovery Act (RCRA) metals were increased by 16X for Se, 29X for Tl, 42X for Ba, 48X for Sb, by 100X for Pb and Ni, 1000X for Ag, and 1297X for Cd to ensure detection by the analytic laboratory used for the demonstration and, as with the LAW simulant, without regard to potential impacts on product durability response such as TCLP. Details of the ESTD testing that was performed in April and May of 2008 are shown in Table 1 as the Operational Summary. The first eight tests were performed on LAW using a Denitration and Mineralization Reformer (DMR) temperature of 725°C and different ratios of clay:simulant of 675 g or 640 g of OptiKast clay per liter of simulant. The last four tests were performed on WTP-SW (originally referred to as LAW-Recycle) using a DMR temperature in the range of 680°C to 700°C with a mixture of 45/55 Sagger/OptiKast clay with 307 g clay/L simulant. The coal feed rates used in the FBSR processing are also shown as noted at the bottom of Table 1. It should be noted that the carbon feed rates are averaged over those periods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report for Treating Hanford LAW and WTP SW Simulants: Pilot Plant Mineralizing Flowsheet

The US Department of Energy is responsible for managing the disposal of radioactive liquid waste in underground storage tanks at the Hanford site in Washington State. The Hanford waste treatment and immobilization plant (WPT) will separate the waste into a small volume of high level waste (HLW), containing most of the radioactive constituents, and a larger volume of low activity waste (LAW), containing most of the non-radioactive chemical and hazardous constituents. The HLW and LAW will be converted into immobilized waste forms for disposal. Currently there is inadequate LAW vitrification capacity planned at the WTP to complete the mission within the required timeframe. Therefore additional LAW capacity is required. One candidate supplemental treatment technology is the fluidized bed steam reformer process (FBSR). This report describes the demonstration testing of the FBSR process using a mineralizing flowsheet for treating simulated Hanford LAW and secondary waste from the WTP (WTP SW). The FBSR testing project produced leach-resistant solid products and environmentally compliant gaseous effluents. The solid products incorporated normally soluble ions into an alkali alumino-silicate (NaS) mineral matrix. Gaseous emissions were found to be within regulatory limits. Cesium and rhenium were captured in the mineralized products with system removal efficiencies of 99.999% and 99.998 respectively. The durability and leach performance of the FBSR granular solid were superior to the low activity reference material (LMR) glass standards. Normalized product consistency test (PCT) release rates for constituents of concern were approximately 2 orders of magnitude less than that of sodium in the Hanford glass [standard].

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Theoretical principles of use of coal fractions with different densities for combustion

It is reasonable to complement the conventional preparation of steam coal involving the removal of ash components and pyritic sulfur by the isolation of the lightest organic fractions, which possess enhanced performance characteristics. These fractions are smoothly saleable both on the domestic and world markets for effective pulverized-coal combustion via new combustion technologies. Heavier (inertinite) fractions of the coal preparation concentrate marketed at lower prices can be considered appropriate fuel for burning in circulating fluidized-bed combustion systems. 13 refs., 5 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗

Characterization of the physical properties for solid granular materials

Accurate prediction of the behavior of a system is strongly governed by the components within that system. For multiphase systems incorporating solid powder-like particles, there are many different physical properties which need to be known to some level of accuracy for proper design, modeling, or data analysis. In the past, the material properties were determined initially as a secondary part of the study or design. In an attempt to provide results with the least level of uncertainty, a procedure was developed and implemented to provide consistent analysis of several different types of materials. The properties that were characterized included particle sizing and size distributions, shape analysis, density (particle, skeletal and bulk), minimum fluidization velocities, void fractions, particle porosity, and assignment within the Geldart Classification. In the methods used for this experiment, a novel form of the Ergun equation was used to determine the bulk void fractions and particle density. Materials of known properties were initially characterized to validate the accuracy and methodology, prior to testing materials of unknown properties. The procedures used yielded valid and accurate results, with a high level of repeatability. A database of these materials has been developed to assist in model validation efforts and future designs. It is also anticipated that further development of these procedures wil be expanded increasing the properties included in the database.

36 MATERIALS SCIENCE↗

Simultaneous removal of SO{sub 2} and NO by highly reactive absorbent containing calcium hypochlorite

Fly ash, industrial lime, and an additive (calcium hypochlorite )) were used to prepare a highly reactive absorbent. Simultaneous desulfurization and denitrification were carried out in a flue gas circulating fluidized bed (CFB). The effects of influencing factors on the removal efficiencies of SO{sub 2} and NO were also investigated. Removal efficiencies of 94.5% for SO{sub 2} and 65.5% for NO were obtained under the optimal experimental conditions. The component of the spent absorbent was analyzed with chemical analysis methods. The results indicated that more nitrogen than sulfur species appeared in the spent absorbent. A scanning electron microscope (SEM) and an accessory X-ray energy spectrometer (EDS) were used to observe the microproperties of the samples, including fly ash, highly reactive absorbent, and spent absorbent. The removal products of spent absorbent were analyzed using ion chromatography and chemical analysis. The simultaneous removal mechanism of SO{sub 2} and NO based on this absorbent was proposed according to the experimental results.

01 COAL, LIGNITE, AND PEAT↗