Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Data-driven gradient optimization for field emission management in a superconducting radio-frequency linac

Field emission can cause significant problems in superconducting radio-frequency linear accelerators (linacs). When cavity gradients are pushed higher, radiation levels within the linacs may rise exponentially, causing degradation of many nearby systems. This research aims to utilize machine learning with uncertainty quantification to predict radiation levels at multiple locations throughout the linacs and ultimately optimize cavity gradients to reduce field emission-induced radiation while maintaining the total linac energy gain necessary for the experimental physics program. The optimized solutions show over 40% reductions for both neutron and gamma radiation from the standard operational settings. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Lithium indium diselenide — An advanced material for neutron detection

Here, this paper describes the synthesis, crystal growth, detector fabrication, radiation hardening studies, MCNP modeling, and characterization of lithium indium diselenide or LiInSe 2 . This newly-developed room temperature thermal neutron detector has semiconducting and scintillating properties and it is suitable for neutron detection application. LiInSe 2 was synthesized starting from elemental Li, In, Se in two steps due to high reactivity of Li. A single crystal of LiInSe 2 was grown using the Vertical Bridgman method. The room temperature band gap was found to be 2.8 eV using optical absorption measurements. Bulk resistivity was measured at ∼5 × 10 11 Ωcm. Photoconductivity measurements of LiInSe 2 wafers identified a peak in the photocurrent around 445 nm. Nuclear radiation detectors were fabricated from single crystal wafer and the responses to alpha particles at various biases were measured. The mobility-lifetime product was estimated. Gamma irradiation studies were performed with calculated absorbed doses ranging from 0.2126 to 21,262 Gy. The characterization of the two wafers for their scintillator performance was conducted after each irradiation. The gamma irradiation produced a reduction of the light yield that translated to a lower channel number for the centroid of alpha detection spectra. It also showed a considerable reduction of the decay time after the first irradiation. These are the first studies on gamma radiation hardening with this material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian estimation of dose thresholds

An example is described of Bayesian estimation of radiation absorbed dose thresholds (subsequently simply referred to as dose thresholds) using a specific parametric model applied to a data set on mice exposed to 60Co gamma rays and fission neutrons. A Weibull based relative risk model with a dose threshold parameter was used to analyse, as an example, lung cancer mortality and determine the posterior density for the threshold dose after single exposures to 60Co gamma rays or fission neutrons from the JANUS reactor at Argonne National Laboratory. The data consisted of survival, censoring times and cause of death information for male B6CF1 unexposed and exposed mice. The 60Co gamma whole-body doses for the two exposed groups were 0.86 and 1.37 Gy. The neutron whole-body doses were 0.19 and 0.38 Gy. Marginal posterior densities for the dose thresholds for neutron and gamma radiation were calculated with numerical integration and found to have quite different shapes. The density of the threshold for 60Co is unimodal with a mode at about 0.50 Gy. The threshold density for fission neutrons declines monotonically from a maximum value at zero with increasing doses. The posterior densities for all other parameters were similar for the two radiation types.

NASA Discipline Radiation Health↗

Evaluation of radiation interference in the Voyager Sun Sensor's cadmium sulfide detector

The simulation of radiation interference effects and the results of a radiation interference test on two Voyager Sun Sensor prototype detector assemblies are reported. The derivation of test levels and requirements are discussed and show that cobalt 60 gamma radiation is an effective and practical simulator of the ionization dose rate effects induced by high-energy electron flux incident on the spacecraft at a rate of 3.7 x 10 to the 8th e/sq cm-sec (10 rad(Si)/s) during closest approach to Jupiter. The test results provide information that is used to confirm an analytic correlation, and to predict satisfactory performance of a spacecraft sun sensing device having stringent angular resolution requirements. The measured detector response shows that at dose rates incident on the detector elements of 2 rad(Si)/sec, which is four times that expected during Jupiter encounter, the radiation-induced angle error is almost an order of magnitude less than that allowed by the acceptance criteria.

Clarke, T. C.↗

Polyvinyl Alcohol and Medium Density Polyethylene Composite Materials for Neutron Radiation Shielding

Manned spacecraft venturing beyond the Earth’s Van Allen Belts will be subjected to high levels of radiation from both energetic particles emanating from the sun and from galactic atomic events, such as supernovae. The metal shell of a spacecraft offers some protection from gamma radiation and high energy particles originating from both the sun and cosmic sources. The interaction of these high energy particles and radiation with the spacecraft hull create secondary radiation and neutrons, additional hazards for astronauts and electronic systems. Shielding of neutrons is the most challenging of the high energy radiation, since neutrons have zero charge and are least affected by electrical fields, magnetic fields, and atomic forces. Previous studies showed that polyethylene is an effective neutron shielding material, due to its high hydrogen content. High energy neutrons are slowed to thermal neutrons through multiple collisions with the hydrogen atoms, increasing the effectiveness of neutron capture by boron-10 atoms. This study discusses the fabrication and testing of polyvinyl alcohol (PVOH) samples as a neutron shielding material, with comparison to medium density polyethylene (MDPE) composite samples to be used for neutron shielding for spacecraft. PVOH, an aqueous polymer, was chosen for hydrogen content and for enabling the use of organic reinforcement such as cellulose for secondary structural composites. OLTARIS (On-Line Tool for the Assessment of Radiation in Space) was used for radiation shielding simulation and compared with experimental data. Modeling indicates that the most effective shielding from radiation was in an aluminum layer backed by a polymer layer, either MDPE or PVOH. Cross-linked PVOH was also included in the OLTARIS modeling. All 3 polymer cases showed shielding improvement over aluminum alone, with similar dose equivalent reduction for galactic cosmic radiation(GCR)and for radiation from a solar particle event (SPE). Fourier Transform Infrared (FTIR) Spectroscopy was used to confirm the cross-linking in the PVOH sample and to determine the uniformity through the thickness. PVOH, cross-linked PVOH, and MDPE samples were tested for neutron shielding effectiveness using a 1 curie Americium-Beryllium neutron source. Test results indicated the most shielding in the cross-linked PVOH, followed by the pristine PVOH, and MDPE. Neutron testing suggests that polyvinyl alcohol is a good alternative to polyethylene for neutron shielding. The neutron shielding materials, PVOH and cross-linked PVOH developed under this research will enable the safe operation of spacecraft beyond the Earth’s protective Van Allen Radiation Belts. It will be crucial for NASA’s manned missions to the Moon or Mars to protect the health of astronauts and equipment from the harmful effects of excessive radiation.

neutron, shielding, radiation, polyvinyl alcohol, ↗

Preliminary results from the first satellite of a high-resolution germanium gamma-ray spectrometer: Description of instrument, some activation lines encountered, and studies of the diffuse spectra

Gamma radiation from terrestrial and extraterrestrial sources were investigated with a high resolution Ge(Li) spectrometer-cryogen system flown onboard a low altitude, spin stabilized, polar orbiting satellite. A brief description is given of the instrument and preliminary results obtained from earth orbit are discussed. Attempts were made to use angular distributions and geomagnetic latitude spectral variations to determine diffuse background spectrum, detect gamma ray line emissions from solar flares, and search for positron annihilation radiation coming from the direction of the galactic center.

Nakano, G. H.↗

Searches for gamma ray emission from radio pulsars

Searches were made for pulsed high energy (E 35 MeV) gamma radiation from 43 pulsars using the SAS-2 data base and radio parameters. No positive results were found, and the upper limits are consistent with the concept that gamma ray production efficiency increases with increasing apparent age. Two limits suggest that efficiency cannot be a simple function of apparent age beyond 10,000,000 years.

Thompson, D. J.↗

Searches for gamma ray emission from radio pulsars

Searches were made for pulsed high energy (E greater than 35 MeV) gamma radiation from 43 pulsars using the SAS-2 data base and radio parameters. No positive results were found, and the upper limits are consistent with the concept that gamma ray production efficiency increases with increasing apparent age. Two limits suggest that efficiency cannot be a simple function of apparent age beyond 1,000,000 years. Previously announced in STAR as N83-24463

Thompson, D. J.↗

Radioadaptive Cytoprotective Pathways in the Mouse Retina

Exposure to cosmic radiation implies a risk of tissue degeneration. Radiation retinopathy is a complication of radiotherapy and exhibits common features with other retinopathies and neuropathies. Exposure to a low radiation dose elicits protective cellular events (radioadaptive response), reducing the stress of a subsequent higher dose. To assess the risk of radiation-induced retinal changes and the extent to which a small priming dose reduces this risk, we used a mouse model exposed to a source of Cs-137-gamma radiation. Gene expression profiling of retinas from non-irradiated control C57BL/6J mice (C) were compared to retinas from mice treated with a low 50 mGy dose (LD), a high 6 Gy dose (HD), and a combined treatment of 50 mGy (priming) and 6 Gy (challenge) doses (LHD). Whole retina RNA was isolated and expression analysis for selected genes performed by RTqPCR. Relevant target genes associated with cell death/survival, oxidative stress, cellular stress response and inflammation pathways, were analyzed. Cellular stress response genes were upregulated at 4 hr after the challenge dose in LHD retinas (Sirt1: 1.5 fold, Hsf1: 1.7 fold, Hspa1a: 2.5 fold; Hif1a: 1.8 fold, Bag1: 1.7). A similar trend was observed in LD animals. Most antioxidant enzymes (Hmox1, Sod2, Prdx1, Cygb, Cat1) and inflammatory mediators (NF B, Ptgs2 and Tgfb1) were upregulated in LHD and LD retinas. Expression of the pro-survival gene Bcl2 was upregulated in LD (6-fold) and LHD (4-fold) retinas. In conclusion, cytoprotective gene networks activation in the retina suggests a radioadaptive response to a priming irradiation dose, with mitigation of the deleterious effects of a subsequent high dose exposure. The enhancement of these cytoprotective mechanisms has potential value as a countermeasure to ocular alterations caused by radiation alone or in combination with other factors in spaceflight environments.

Zanello, Susana B.↗

High-Z Sensitized Plastic Scintillators: A Review

The need for affordable and reliable radiation detectors has prompted significant investment in new radiation detector materials, due to concerns about national security and nuclear nonproliferation. Plastic scintillators provide an affordable approach to large volume detectors, yet their performance for high-energy gamma radiation is severely limited by the small radiation stopping power inherent to their low atomic number. Although some sensitization attempts with organometallics were made in the 1950s to 1960s, the concomitant decrease in light yield has limited the usefulness of these sensitized detectors. Recently, with new knowledge gained during the rapid development of organic optoelectronics and nanotechnology, there has been a revived interest in the field of heavy element sensitized plastic scintillators. In this paper, the recent efforts on sensitized plastic scintillators are summarized. Basic scintillator physics is first reviewed. The discussion then focuses on two major thrusts in the field: sensitization with: (1) organometallics and (2) oxide and fluoride nanoparticles. The design rationales and major results are examined in detail, with existing limitations and possible future pathways discussed. Lastly, special attention is paid to the underlying energy deposition and transfer processes, as these determine the key performance metrics such as light yield and radioluminescence decay lifetime.

36 MATERIALS SCIENCE↗

On the Mechanism of the Steady-State Gamma Radiolysis-Induced Scissions of the Phenyl-Vinyl Polyester-Based Resins

The major societal problem of polymeric waste necessitates new approaches to break down especially challenging discarded waste streams. Gamma radiation was utilized in conjunction with varying solvent environments in an attempt to discern the efficacy of radiolysis as a tool for the deliberate degradation of model network polyesters. Our EPR results demonstrated that gamma radiolysis of neat resin and in the presence of four widely used solvents induces glycosidic scissions on the backbone of the polyester chains. EPR results clearly show the formation of alkoxy radicals and C-centered radicals as primary intermediate radiolytic products. Despite the protective role of the phenyl groups on the backbone of the radiation-induced polyester chains, the radiolytic-glycosidic scissions predominate. Among the following three solvents used in this study (water, isopropyl alcohol, and dichloromethane), the highest radiolytic yield of glycosidic scission was achieved using water. The •OH radicals produced in the radiolysis of phenyl unsaturated polyester aqueous suspensions very rapidly abstract H atoms from the methylene group, which is followed by a very rapid glycosidic scission. The lowest glycosidic yield was found in the dichloromethane solutions of these polyester resins due to scavenging by the fast electron capture reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Milagro limits and HAWC sensitivity for the rate-density of evaporating primordial black holes

Primordial Black Holes (PBHs) are gravitationally collapsed objects that may have been created by density fluctuations in the early universe and could have arbitrarily small masses down to the Planck scale. Hawking showed that due to quantum effects, a black hole has a temperature inversely proportional to its mass and will emit all species of fundamental particles thermally. PBHs with initial masses of ~ 5.0 × 10¹⁴ g should be expiring in the present epoch with bursts of high-energy particles, including gamma radiation in the GeV – TeV energy range. The Milagro high energy observatory, which operated from 2000 to 2008, is sensitive to the high end of the PBH evaporation gamma-ray spectrum. Due to its large field-of-view, more than 90% duty cycle and sensitivity up to 100 TeV gamma rays, the Milagro observatory is well suited to perform a search for PBH bursts. Based on a search on the Milagro data, we report new PBH burst rate density upper limits over a range of PBH observation times. In addition, we report the sensitivity of the Milagro successor, the High Altitude Water Cherenkov (HAWC) observatory, to PBH evaporation events.

79 ASTRONOMY AND ASTROPHYSICS↗

Organic Vacuum Pump Fluids for the Vacuum Pumping of Fusion Power Plants

Vacuum pumps are the heart of the fusion fuel cycle, but most currently proposed pumping technologies are not capable of handling the required flow rates and vacuum pressures. Oil-containing vacuum pumps can readily meet the flow requirements, but vacuum fluids will degrade in fusion-relevant environments due to contact with tritium and exposure to high-energy radiation. Here, in this study, we describe a methodology to screen vacuum fluid candidates and purify these candidate fluids post oxidation, post exposure to deuterium, and post exposure to gamma radiation (<7.5 MGy) to simulate a process in which vacuum fluids can be recovered and regenerated during the fusion fuel cycle. A series of oils, including a highly purified mineral oil, phenyl silicone oil, and a polyphenyl ether, are shown to be suitable candidates for vacuum pumping. Additionally, we describe a simple purification methodology to remove oxidized functionalities and the associated isotopologues induced by contact with deuterium from the candidate vacuum fluids This purification methodology can also be applied to radiological damage with moderate effect. Finally, we demonstrate that the sorbents can be regenerated through electromagnetic microwave digestion.

oxidation↗

Radiation-hardness studies with cerium-doped fused-silica fibers

In this work, we describe our R&D effort to develop potentially radiation-hard scintillating and wavelength shifting fibers by doping fused-silica with cerium. The cerium-doped optical fibers with different core structures and concentrations were exposed to gamma radiation (60Co) at different dose rates up to 100 kGy. We evaluated the radiation-induced degradation in photoluminescence, optical transmission, and recovery phenomena in the wavelength range from 300 to 700 nm. We were able to model the experimental data based on second-order rate equations where the fit parameters that govern the damage profile were utilized to predict recovery. We also measured the influence of radiation on the numerical aperture. Finally, we offer some thoughts on the use of these types of fibers in particle and nuclear physics detectors.

36 MATERIALS SCIENCE↗

Developing a radiation-aging model for polymeric foam cushions

Motivation: A major component of the A&L constitutive modeling effort over the last couple of years has involved developing a thermal aging model for foam cushions. Through extensive studies of uniaxial compression data, we have established that the Ogden N = 2 Hyperfoam in conjunction with the Tobolsky two-network model [Ref. 4] provides an accurate theoretical framework to describe the results, both for the traditional (stochastic) as well as the AM (3D-printed) foam pads. The results display numerical accuracy over a wide range of compression levels, from low to moderate up to slightly over 90% of lock-up. Over the last few weeks we have been exploring radiation aging data on a specific 3D printed foam, i.e., SE1700 AM FCT foam, to see if the Ogden + Tobolsky model can explain such data as well, and if so, how the various model parameters change as a function of dosage. As this report shows, the answer is indeed yes. We find that the modulus of the second (i.e., induced network) increases nearly proportionally with the radiation dosage, with a smaller sub-linear decrease in the primary shear modulus of the original network. This is consistent with the interpretation that exposure to energetic gamma-radiation is dominated by the formation of new cross-links. Significance: An important goal of A&L modeling efforts is to develop a fully age-aware materials model that can describe the joint effects of commonly present aging drivers like temperature, radiation, humidity, etc. Such a model is necessary to assess the lifetime of essential components like polymeric foams and rubber pads.

36 MATERIALS SCIENCE↗

Low and medium energy galactic gamma-ray observations

Observation of 0.2-100 MeV diffuse gamma radiation emitted from the Galaxy can provide information on the intensities of 5-50 MeV/nucleon cosmic-rays and 50 MeV electrons in interstellar space. Recent measurements of gamma-rays emitted from the galactic center region provide evidence for a diffuse continuum between 10 and 100 MeV. The intensities of the recently reported nuclear line gamma rays, also observed in the direction of the galactic center, require the presence of intense fluxes of low-energy cosmic-rays in the inner Galaxy if the gamma-rays are produced on a galactic scale. Current detection techniques for 0.1-100 MeV gamma-ray measurements are summarized and their capabilities for measuring the diffuse galactic emission are evaluated.

Share, G. H.↗

Cosmic gamma rays from quasars

The diffuse gamma radiation consists of the galactic and extragalactic components. The latter component is of special interest on account of its cosmological significance. Following the method recently proposed to estimate the gamma ray flux from galaxy clusters, and the detection of gamma rays from the quasars 3C273, the data base of the SAS II satellite was used to estimate the contribution from quasars to the extragalactic gamma ray flux. It is shown that quasars as a whole are significant gamma ray contributors, the average gamma ray flux per quasar in the energy range 35 MeV to 100 Mev being (1.3 + or - 0.9) x .00001 cm(-2)s(-1)sr(-1).

Lau, M. M.↗

Detection of high-energy gamma-ray emission from the BL Lacertae object Markarian 421 by the Egret telescope on the Compton Observatory

Gamma radiation in the energy range from 50 MeV to well over 1 GeV has been observed from the direction of the BL Lac object Markarian 421 by the Energetic Gamma Ray Experiment Telescope on the Compton Observatory during the period 1991 June 27-July 11. The source flux is weak, but still statistically significant at the level of 10 exp -5; the integrated photon flux above 100 MeV is (1.4 +/- 0.3) x 10 exp -7/sq cm s. The differential photon energy spectrum can be represented by a power law with exponent 1.96 +/- 0.14. This is the first detection of gamma-ray emission from a BL Lac object.

Lin, Y. C.↗