Symbolic construction of the chemical Jacobian of quasi-steady state (QSS) chemistries for Exascale computing platforms

The Quasi-Steady State Approximation (QSSA) can be an effective tool for reducing the size and stiffness of chemical mechanisms for implementation in computational reacting flow solvers. However, for many applications, the resulting model still requires implicit methods for efficient time integration. Here, in this paper, we outline an approach to formulating the QSSA reduction that is coupled with a strategy to generate C++ source code to evaluate the net species production rates, and the chemical Jacobian. The code-generation component employs a symbolic approach enabling a simple and effective strategy to analytically compute the chemical Jacobian. For computational tractability, the symbolic approach needs to be paired with common subexpression elimination which can negatively affect memory usage. Several solutions are outlined and successfully tested on a 3D multipulse ignition problem, thus allowing portable application across chemical model sizes and GPU capabilities. The implementation of the proposed method is available at https://github.com/AMReX-Combustion/PelePhysics under an open-source license.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nb{sub 3}Sn superconducting magnets for electron cyclotron resonance ion sources

Electron cyclotron resonance (ECR) ion sources are an essential component of heavy-ion accelerators. Over the past few decades advances in magnet technology and an improved understanding of the ECR ion source plasma physics have led to remarkable performance improvements of ECR ion sources. Currently third generation high field superconducting ECR ion sources operating at frequencies around 28 GHz are the state of the art ion injectors and several devices are either under commissioning or under design around the world. At the same time, the demand for increased intensities of highly charged heavy ions continues to grow, which makes the development of even higher performance ECR ion sources a necessity. To extend ECR ion sources to frequencies well above 28 GHz, new magnet technology will be needed in order to operate at higher field and force levels. The superconducting magnet program at LBNL has been developing high field superconducting magnets for particle accelerators based on Nb{sub 3}Sn superconducting technology for several years. At the moment, Nb{sub 3}Sn is the only practical conductor capable of operating at the 15 T field level in the relevant configurations. Recent design studies have been focused on the possibility of using Nb{sub 3}Sn in the next generation of ECR ion sources. In the past, LBNL has worked on the VENUS ECR, a 28 GHz source with solenoids and a sextupole made with NbTi operating at fields of 6-7 T. VENUS has now been operating since 2004. We present in this paper the design of a Nb{sub 3}Sn ECR ion source optimized to operate at an rf frequency of 56 GHz with conductor peak fields of 13-15 T. Because of the brittleness and strain sensitivity of Nb{sub 3}Sn, particular care is required in the design of the magnet support structure, which must be capable of providing support to the coils without overstressing the conductor. In this paper, we present the main features of the support structure, featuring an external aluminum shell pretensioned with water-pressurized bladders, and we analyze the expected coil stresses with a two-dimensional finite element mechanical model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nb3Sn superconducting magnets for electron cyclotron resonance ion sources

Electron cyclotron resonance (ECR) ion sources are an essential component of heavy-ion accelerators. Over the past few decades advances in magnet technology and an improved understanding of the ECR ion source plasma physics have led to remarkable performance improvements of ECR ion sources. Currently third generation high field superconducting ECR ion sources operating at frequencies around 28 GHz are the state of the art ion injectors and several devices are either under commissioning or under design around the world. At the same time, the demand for increased intensities of highly charged heavy ions continues to grow, which makes the development of even higher performance ECR ion sources a necessity. To extend ECR ion sources to frequencies well above 28 GHz, new magnet technology will be needed in order to operate at higher field and force levels. The superconducting magnet program at LBNL has been developing high field superconducting magnets for particle accelerators based on Nb{sub 3}Sn superconducting technology for several years. At the moment, Nb{sub 3}Sn is the only practical conductor capable of operating at the 15 T field level in the relevant configurations. Recent design studies have been focused on the possibility of using Nb{sub 3}Sn in the next generation of ECR ion sources. In the past, LBNL has worked on the VENUS ECR, a 28 GHz source with solenoids and a sextupole made with NbTi operating at fields of 6-7 T. VENUS has now been operating since 2004. We present in this paper the design of a Nb{sub 3}Sn ECR ion source optimized to operate at an rf frequency of 56 GHz with conductor peak fields of 13-15 T. Because of the brittleness and strain sensitivity of Nb{sub 3}Sn- , particular care is required in the design of the magnet support structure, which must be capable of providing support to the coils without overstressing the conductor. In this paper, we present the main features of the support structure, featuring an external aluminum shell pretensioned with water-pressurized bladders, and we analyze the expected coil stresses with a two-dimensional finite element mechanical model.

43 PARTICLE ACCELERATORS↗

A Compound Poisson Generator Approach to Point-source Inference in Astrophysics

Abstract The identification and description of point sources is one of the oldest problems in astronomy, yet even today the correct statistical treatment for point sources remains one of the field’s hardest problems. For dim or crowded sources, likelihood-based inference methods are required to estimate the uncertainty on the characteristics of the source population. In this work, a new parametric likelihood is constructed for this problem using compound Poisson generator (CPG) functionals that incorporate instrumental effects from first principles. We demonstrate that the CPG approach exhibits a number of advantages over non-Poissonian template fitting (NPTF)—an existing method—in a series of test scenarios in the context of X-ray astronomy. These demonstrations show that the effect of the point-spread function, effective area, and choice of point-source spatial distribution cannot, generally, be factorized as they are in NPTF, while the new CPG construction is validated in these scenarios. Separately, an examination of the diffuse-flux emission limit is used to show that most simple choices of priors on the standard parameterization of the population model can result in unexpected biases: when a model comprising both a point-source population and diffuse component is applied to this limit, nearly all observed flux will be assigned to either the population or to the diffuse component. A new parameterization is presented for these priors that properly estimates the uncertainties in this limit. In this choice of priors, CPG correctly identifies that the fraction of flux assigned to the population model cannot be constrained by the data.

79 ASTRONOMY AND ASTROPHYSICS↗

Characteristics of 80 keV positive ion source for Large Helical Device

An additional beamline, BL5, equipped with four positive ion sources will be installed on Large Helical Device (LHD) in 2010. The performance of an ion source which generates 80 keV deuterium and 60 keV hydrogen beams was investigated. The structure of the ion source is based on that of a BL4 ion source on LHD. The main differences between the ion sources for the BL4 and BL5 are the acceleration voltages and the materials of plasma electrodes: copper and molybdenum, respectively. The molybdenum plasma electrode for BL5 has better performance than the copper plasma electrode of BL4. The integrated performance of the ion source for BL5 reached a value equivalent to {approx}58 A in the beam current of hydrogen positive ion at 60 keV in the beam energy.

43 PARTICLE ACCELERATORS↗

Neutron Science TeraGrid Gateway

The unique contributions of the Neutron Science TeraGrid Gateway (NSTG) are the connection of national user facility instrument data sources to the integrated cyberinfrastructure of the National Science FoundationTeraGrid and the development of a neutron science gateway that allows neutron scientists to use TeraGrid resources to analyze their data, including comparison of experiment with simulation. The NSTG is working in close collaboration with the Spallation Neutron Source (SNS) at Oak Ridge as their principal facility partner. The SNS is a next-generation neutron source. It has completed construction at a cost of $1.4 billion and is ramping up operations. The SNS will provide an order of magnitude greater flux than any previous facility in the world and will be available to all of the nation's scientists, independent of funding source, on a peer-reviewed merit basis. With this new capability, the neutron science community is facing orders of magnitude larger data sets and is at a critical point for data analysis and simulation. There is a recognized need for new ways to manage and analyze data to optimize both beam time and scientific output. The TeraGrid is providing new capabilities in the gateway for simulations using McStas and a fitting service on distributed TeraGrid resources to improved turnaround. NSTG staff are also exploring replicating experimental data in archival storage. As part of the SNS partnership, the NSTG provides access to gateway support, cyberinfrastructure outreach, community development, and user support for the neutron science community. This community includes not only SNS staff and users but extends to all the major worldwide neutron scattering centers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transient thermal stress wave and vibrational analyses of a thin diamond crystal for X-ray free-electron lasers under high-repetition-rate operation

High-brightness X-ray free-electron lasers (FELs) are perceived as fourth-generation light sources providing unprecedented capabilities for frontier scientific researches in many fields. Thin crystals are important to generate coherent seeds in the self-seeding configuration, provide precise spectral measurements, and split X-ray FEL pulses, etc . In all of these applications a high-intensity X-ray FEL pulse impinges on the thin crystal and deposits a certain amount of heat load, potentially impairing the performance. In the present paper, transient thermal stress wave and vibrational analyses as well as transient thermal analysis are carried out to address the thermomechanical issues for thin diamond crystals, especially under high-repetition-rate operation of an X-ray FEL. The material properties at elevated temperatures are considered. It is shown that, for a typical FEL pulse depositing tens of microjoules energy over a spot of tens of micrometers in radius, the stress wave emission is completed on the tens of nanoseconds scale. The amount of kinetic energy converted from a FEL pulse can reach up to ~10 nJ depending on the layer thickness. Natural frequencies of a diamond plate are also computed. The potential vibrational amplitude is estimated as a function of frequency. Here, due to the decreasing heat conductivity with increasing temperature, a runaway temperature rise is predicted for high repetition rates where the temperature rises abruptly after ratcheting up to a point of trivial heat damping rate relative to heat deposition rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the difficulty of diagnostics. For most cases, intercepting measurements are no longer acceptable, and nonintercepting method like synchrotron radiation monitor can not be applied to linear accelerators. The development of accelerator technology asks for simutanous diagnostics innovations, to expand the performance of diagnostic tools to meet the requirements of the next generation accelerators. Diffraction radiation and inverse Compton scattering are two of the most promising techniques, their nonintercepting nature avoids perturbance to the beam and damage to the instrumentation. This thesis is divided into two parts, beam size measurement by optical diffraction radiation and Laser system for Compton polarimeter. Diffraction radiation, produced by the interaction between the electric field of charged particles and the target, is related to transition radiation. Even though the theory of diffraction radiation has been discussed since 1960s, there are only a few experimental studies in recent years. The successful beam size measurement by optical diffraction radiation at CEBAF machine is a milestone: First of all, we have successfully demonstrated diffraction radiation as an effective nonintercepting diagnostics; Secondly, the simple linear relationship between the diffraction radiation image size and the actual beam size improves the reliability of ODR measurements; And, we measured the polarized components of diffraction radiation for the first time and I analyzed the contribution from edge radiation to diffraction radiation.

43 PARTICLE ACCELERATORS↗

Coupling of ELF/ULF energy from lightning and MeV particles to the middle atmosphere, inosphere, and global circuit

In an attempt to explain numerous atmospheric electrical phenomena, the elements of the global electrical circuit are reexamined. In addition to being a 'quasi-static 'DC' generator' and source of radiated energy at VLF and higher, the thunderstorm is found to be a pulse generator, with most of the external energy contained in ELF and ULF pulse currents to the ionosphere (and Earth). The pulse energy is found to deposit largely in the middle atmosphere above the thunderstorm. The VLF and above components are well understood, as are the ULF components due to the conductivity gradient. However, a previously poorly understood ELF component on the millsecond timescale, or 'slow tail,' contains a large fraction of the electrical energy. This component couples strongly to the ionosphere and also launches a unipolar transverse electromagnetic (TEM) wavelet in the radial Earth-ionosphere transmission line. The increase in charge with distance associated with such wavelets, and their ensemble sum at a point, may explain some large mesospheric 'DC' fields but there are still difficulties explaining other than rare occurrences, except for antipodal reconvergence. These millisecond duration unipolar wavelets also coupled to the ionosphere and may trigger other lightning at a distance. A schema is elucidated by which the charge of MeV particles deposited in the middle atmosphere persists for much longer than the local relaxation time. This also gives rise to unipolar waves of global extent which may explain lower-latitude field perturbations associated with solar/geomagnetic events.

Hale, Leslie C.↗

Enhanced Harmonic Up-Conversion Using a Hybrid HGHG-EEHG Scheme

We introduce a novel harmonic generation scheme which can be used, for a given desired harmonic, to achieve higher bunching factors, weaker chicanes, and/or less final energy spread than can be achieved using Echo-Enabled Harmonic Generation. This scheme only requires a single laser with relatively low power, and is a hybrid of High-Gain Harmonic Generation and EEHG. We present a design of this scheme applied to the Next Generation Light Source (NGLS).

43 PARTICLE ACCELERATORS↗

Estimating SHmax azimuth with P sources and vertical geophones: Use P-P reflection amplitudes or use SV-P reflection times?

We compared two methods for extracting the azimuth of maximum horizontal stress (SHmax) from 3D land-based seismic data generated by a P source and recorded with vertical geophones. In the first method, we used the direct-SV mode that is produced by all land-based P sources. P sources generate SV illumination that radiates in all azimuth directions from a source station and creates SV-P reflections that are recorded by vertical geophones. Unless stratigraphy has steep dip, SV-P raypaths recorded by vertical geophones are the reverse of P-SV raypaths recorded by horizontal geophones. Thus, SV-P data provide the same S-wave sensitivity to stress fields as popular P-SV data do. In the second method, we retrieved P-P reflections and then performed an amplitude-variation-with-azimuth (AVA) analysis of the amplitude-gradient behavior of P-P reflection wavelets. We did this analysis in narrow azimuth corridors to determine the gradient of reflection-wavelet amplitudes as a function of azimuth. This P-P AVA amplitude-gradient method has been of great interest in the reflection seismology community since it was introduced in the late 1990s. Each of these methods, AVA analysis of the gradient of P-P reflection amplitudes and azimuth-dependent arrival times of SV-P reflections, can be used to determine the azimuth of SHmax stress. We compare the results of the two methods with ground truth measurements of SHmax azimuth at a CO 2 sequestration site in the Michigan Basin. SHmax azimuths were determined from P-P and SV-P data at three major boundaries at depths of approximately 3500 ft (1067 m), 5500 ft (1676 m), and 7500 ft (2286 m). Two estimates of SHmax azimuth (one using SV-P data and one using P-P data) were made at each stacking bin inside a 24 mi 2 (62 km 2 ) image space. The result was approximately 98,000 estimates of SHmax azimuth across each of these three boundaries for each of these two prediction strategies. Histogram displays of PP AVA gradient estimates had peaks at correct azimuths of SHmax at all three depths, but the spread of the distributions widened with depth and split into two peaks at the deepest boundary. In contrast, each histogram of SHmax azimuth predicted by azimuth-dependent SV-P traveltimes had a single, definitive peak that was positioned at the correct SHmax azimuth at all three boundary depths.

Geochemistry & Geophysics↗

An Evaluation of a Passively Cooled Cylindrical Spectrometer Array in Lunar Orbit

This thesis will evaluate a passively cooled cylindrical spectrometer array in lunar orbit characterizing the thermal response in order to provide context for decision-making to scientists and engineers. To provide perspective on thermal issues and controls of space science instruments, a background search of historical lunar missions is provided. Next, a trial science mission is designed and analyzed which brings together the elements of the background search, lunar orbit environment and passive cooling. Finally, the trial science mission analysis results are provided along with the conclusions drawn. Scintillators are materials that when struck by particle radiation, absorb the particle energy which is then reemitted as light in or near the visible range. Nuclear astrophysics utilizes scintillating materials for observation of high-energy photons which are generated by sources such as solar flares, supernovae and neutron stars. SPMs are paired with inorganic scintillators to detect the light emitted which is converted into electronic signals. The signals are captured and analyzed in order to map the number and location of the high-energy sources. The SPM is utilized as it has single photon sensitivity, low voltage requirements and a fast response. SPMs are also compact, relatively inexpensive and allow the usage of lower-cost scintillating materials within the spectrometer. These characteristics permit large-area arrays while lowering cost and power requirements. The ability of a spectrometer to record and identify the interaction of high-energy photons for scientific return is not a trivial matter. Background noise is generated when particles that have not originated from the desired distant source impact the spectrometer. Additionally, thermally induced electrical signals are randomly generated within the SPM even in the absence of light which is referred to as dark current. Overcoming these obstacles requires greater light emittance and energy resolution with reduced dark current. Strong scintillation photon emittance ensures that low energy impacts will produce enough visible photons to be detected by the SPM. Higher energy resolution will ensure that single photon impacts can be distinguished from others of similar wavelength and energy; reduced dark current decreases the generation of random signals not associated with a photon impact. Increasing efficiency in each of these properties in a spectrometer comprised of inorganic scintillators and SPMs requires low temperatures. Low temperature maintenance in a lunar environment presents many unique challenges of its own. Even with the accumulated successes of past missions, the lunar environment remains a thermal challenge for engineers. The lunar orbit thermal environment is driven by radiation from three sources, direct solar radiation, reflected solar radiation from the lunar surface (albedo) and lunar radiation (Clawson 2002). Direct solar radiation values are consistent with those seen in Earth orbit (1325 W/m2) (Clawson 2002). The percentage of solar radiation reflected from the moon is consistently very low with the moon's dark regolith covered surface absorbing nearly 90% of the incident light (Clawson 2002). Yet, it is this absorption that gives the lunar orbit environment one of its most difficult thermal attributes as the absorbed solar radiation is released from the lunar surface as infrared radiation (IR). IR is of a wavelength that is readily absorbed by surfaces designed to function as radiation emitters. It is practical to therefore "choose radiator locations and spacecraft attitude to minimize radiator views to the lunar surface, when possible...pointing the radiator towards the sun to some extent, to minimize its view to the lunar surface, is frequently preferable. (Clawson 2002)" Additionally, the amount of direct solar radiation, lunar IR and albedo an orbiting satellite receives varies from one side of the moon to the other as the moon blocks the sun from view. This environment produces large temperature variations in a satellite's instrumentation, control electronics and propulsion systems which must be understood to characterize operating temperature envelopes.

Waggoner, Jason↗

New X-Ray Spectrometer Developed

X-ray absorption spectroscopy (XAS) and X-ray emission spectroscopy (XES) are useful tools for characterizing numerous properties of a given material. They can give elemental composition, metal oxidation states, spin state, orbital occupancy, and more. A drawback is that these types of measurements have historically needed synchrotron light sources to generate high flux X-ray beams and high-resolution monochromators to provide a monoenergetic excitation source. Synchrotrons are building-sized facilities (often operated in the U.S. by the DOE) and have the scheduling complexities and logistical issues that accompany any large-scale research facility. There are added challenges for scientists wishing to analyze radioactive samples such as plutonium or other actinides. These limitations are now mitigated by a small, “portable” X-ray emission and absorption spectrometers developed by Los Alamos scientists and the University of Washington.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Nano and Mesoscale Deformation Structures with Intense X-ray Synchrotron Sources

Advanced polychromatic microdiffraction is sensitive to the organization of dislocations and other defects that rotate the lattice planes. Using ultra-brilliant third-generation synchrotron sources and non-dispersive X-ray focusing optics, it is now possible to analyze individual dislocation cells and walls at a submicron scale that cannot be probed by traditional methods. The method is applied to an Ir weld sample to illustrate how microdiffraction can be used to determine the locally active dislocation system.

43 PARTICLE ACCELERATORS↗

Surface plasma source with saddle antenna radio frequency plasma generator

A prototype RF H{sup -} surface plasma source (SPS) with saddle (SA) RF antenna is developed which will provide better power efficiency for high pulsed and average current, higher brightness with longer lifetime and higher reliability. Several versions of new plasma generators with small AlN discharge chambers and different antennas and magnetic field configurations were tested in the plasma source test stand. A prototype SA SPS was installed in the Spallation Neutron Source (SNS) ion source test stand with a larger, normal-sized SNS AlN chamber that achieved unanalyzed peak currents of up to 67 mA with an apparent efficiency up to 1.6 mA/kW. Control experiments with H{sup -} beam produced by SNS SPS with internal and external antennas were conducted. A new version of the RF triggering plasma gun has been designed. A saddle antenna SPS with water cooling is fabricated for high duty factor testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Postacceleration Of Laser-Generated High Energy Protons Through Conventional Accelerator Linacs

The post-acceleration of laser-generated protons through conventional drift tube linear accelerators has been simulated with the particle code Parmela. The proton source is generated on the rear surface of a target irradiated by an high-intensity (10{sup 19} W{center_dot}cm{sup -2}) short-pulse (350 fs) laser and focused by a microlens that allows selecting collimated protons at 7{+-}0.1 MeV with rms unnormalized emittance of 0.180 mm.mrad. The simulations show that protons can be accelerated by one drift tube linac tank to more than 14 MeV with unnormalized emittance growth of 8 in x and 22.6 in y directions when considering a total proton charge of 0.112 mA. This result shows for the first time that coupling between laser-plasma accelerators with traditional accelerators is possible, allowing a luminosity gain for the final beam.

43 PARTICLE ACCELERATORS↗

Characteristic of a triple-cathode vacuum arc plasma source

In order to generate a better ion beam, a triple-cathode vacuum arc plasma source has been developed. Three plasma generators in the vacuum arc plasma source are equally located on a circle. Each generator initiated by means of a high-voltage breakdown between the cathode and the anode could be operated separately or simultaneously. The arc plasma expands from the cathode spot region in vacuum. In order to study the behaviors of expanding plasma plume generated in the vacuum arc plasma source, a Langmuir probe array is employed to measure the saturated ion current of the vacuum arc plasma source. The time-dependence profiles of the saturated current density of the triple vacuum arc plasma source operated separately and simultaneously are given. Furthermore, the plasma characteristic of this vacuum arc plasma source is also presented in the paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗