Residually Stressed Bimaterial Beam Specimen for Measuring Environmentally Assisted Crack Growth

Background: Subcritical crack growth can occur in a brittle material when the stress intensity factor is smaller than the fracture toughness if an oxidizing agent (such as water) is present at the crack tip. Objective: Here we present a novel bi-material beam specimen which can measure environmentally assisted crack growth rates. The specimen is “self-loaded” by residual stress and requires no external loading. Methods: Two materials with different coefficient of thermal expansion are diffusion bonded at high temperature. After cooling to room temperature a subcritical crack is driven by thermal residual stresses. A finite element model is used to design the specimen geometry in terms of material properties in order to achieve the desired crack tip driving force. Results: The specimen is designed so that the crack driving force decreases as the crack extends, thus enabling the measurement of the crack velocity versus driving force relationship with a single test. The method is demonstrated by measuring slow crack growth data in soda lime silicate glass and validated by comparison to previously published data. Conclusions: The self-loaded nature of the specimen makes it ideal for measuring the very low crack velocities needed to predict brittle failure at long lifetimes.

36 MATERIALS SCIENCE↗

Friction and Wear Properties of CrSiCN/SiC Tribopairs in Water Lubrication

CrSiCN coatings (3.4 at.% Si) were prepared on 316L stainless steels using unbalanced magnetron sputtering. According to the analysis results of x-ray diffractometer and x-ray photoelectrons spectroscopy, silicon in CrSiCN coatings mainly presented in the amorphous forms of a-SiN, a-SiCN and a-SiC. The hardness and Young’s modulus of CrSiN coatings were 19.4 ± 0.6 and 306.1 ± 5.9 GPa, respectively. In addition, the ball-on-disk sliding tests of CrSiCN/SiC tribopairs were performed in distilled water at varying velocities (0.1-0.5 m/s) and loads (2-12 N). The friction coefficient of tribopairs presented a decreasing trend with respect to velocity at low applied loads (≤ 4 N). To be specific, the low friction coefficient of 0.05-0.14 accompanied with polished wear scar was obtained at high velocities and low loads. Finally, the wear mechanism map of CrSiCN/SiC tribopairs was proposed based on a combination of friction coefficient, wear scar morphology and wear rates of tribopairs.

36 MATERIALS SCIENCE↗

Mitigation of Shuttle Effect in Li–S Battery Using a Self-Assembled Ultrathin Molybdenum Disulfide Interlayer

Lithium–sulfur batteries are promising for low-cost and high-energy storage, but their applications are still limited by poor cycling stability owing to soluble lithium polysulfide shuttling during battery operation. Avoiding shuttle effect is challenging but it is essential to avoid active material loss and prevent performance decay. We use an ultrathin layer of MoS 2 with thickness of 10–40 nm, which is 1–2 orders of magnitude thinner than conventional interlayers, for Li–S batteries to mitigate polysulfide shuttling. The MoS2 layer formed by exfoliated nanoflakes is deposited by the scalable liquid-based self-assembly method. With less than 1% of additional weight in the cathode, the MoS 2 interlayer with complete coverage inhibits polysulfide diffusion across the separator and therefore remarkably improves the battery performances. Reversible specific capacity reaches 1010 and 600 mA h g –1 at 0.5 and 2C rates, respectively, which decay slowly over 400 cycles (0.11% per cycle). Moreover, the MoS 2 films with high density of catalytic active flake edges enable high areal sulfur loading up to 10 mg cm –2 and areal capacity up to 9.7 mA h cm –2 at a current density of 3.2 mA cm –2 .

25 ENERGY STORAGE↗

Measurement of specimen dimensions and dynamic pressure in dynamic triaxial experiments

Novel experimental techniques are developed to measure the rapid changes in specimen dimensions during dynamic triaxial experiments. A capacitance gage is designed and constructed to measure the diameter change of the specimen inside the pressure chamber at both low and high rates. The length change is determined by a linear variable differential transformer at low rates and by Kolsky bar signals at high rates. The Kolsky bar also measures the dynamic axial stress in the specimen during the high-rate phase of an experiment. A line pressure gage records the hydrostatic pressure in the chamber. The dynamic pressure variation in the chamber during axial impact loading is detected by a manganin gage placed inside the chamber. The feasibility of this new experimental setup is demonstrated by dynamic triaxial experiments on a fine dry sand.

42 ENGINEERING↗

Visible-light active thin-film WO{sub 3} photocatalyst with controlled high-rate deposition by low-damage reactive-gas-flow sputtering

A process based on reactive gas flow sputtering (GFS) for depositing visible-light active photocatalytic WO{sub 3} films at high deposition rates and with high film quality was successfully demonstrated. The deposition rate for this process was over 10 times higher than that achieved by the conventional sputtering process and the process was highly stable. Furthermore, Pt nanoparticle-loaded WO{sub 3} films deposited by the GFS process exhibited much higher photocatalytic activity than those deposited by conventional sputtering, where the photocatalytic activity was evaluated by the extent of decomposition of CH{sub 3}CHO under visible light irradiation. The decomposition time for 60 ppm of CH{sub 3}CHO was 7.5 times more rapid on the films deposited by the GFS process than on the films deposited by the conventional process. During GFS deposition, there are no high-energy particles bombarding the growing film surface, whereas the bombardment of the surface with high-energy particles is a key feature of conventional sputtering. Hence, the WO{sub 3} films deposited by GFS should be of higher quality, with fewer structural defects, which would lead to a decrease in the number of centers for electron-hole recombination and to the efficient use of photogenerated holes for the decomposition of CH{sub 3}CHO.

36 MATERIALS SCIENCE↗

Diamond channel-cut crystals for high-heat-load beam-multiplexing narrow-band X-ray monochromators

Next-generation high-brilliance X-ray photon sources call for new X-ray optics. Here we demonstrate the possibility of using monolithic diamond channel-cut crystals as high-heat-load beam-multiplexing narrow-band mechanically stable X-ray monochromators with high-power X-ray beams at cutting-edge high-repetition-rate X-ray free-electron laser (XFEL) facilities. The diamond channel-cut crystals fabricated and characterized in these studies are designed as two-bounce Bragg reflection monochromators directing 14.4 or 12.4 keV X-rays within a 15 meV bandwidth to 57 Fe or 45 Sc nuclear resonant scattering experiments, respectively. The crystal design allows out-of-band X-rays transmitted with minimal losses to alternative simultaneous experiments. Only ≲2% of the incident ∼100 W X-ray beam is absorbed in the 50 µm-thick first diamond crystal reflector, ensuring that the monochromator crystal is highly stable. Other X-ray optics applications of diamond channel-cut crystals are anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shifts in bacterial traits under chronic nitrogen deposition align with soil processes in arbuscular, but not ectomycorrhizal-associated trees

Nitrogen (N) deposition increases soil carbon (C) storage by reducing microbial activity. These effects vary in soil beneath trees that associate with arbuscular (AM) and ectomycorrhizal (ECM) fungi. Variation in carbon C and N uptake traits among microbes may explain differences in soil nutrient cycling between mycorrhizal associations in response to high N loads, a mechanism not previously examined due to methodological limitations. Here, we used quantitative Stable Isotope Probing (qSIP) to measure bacterial C and N assimilation rates from an added organic compound, which we conceptualize as functional traits. As such, we applied a trait-based approach to explore whether variation in assimilation rates of bacterial taxa can inform shifts in soil function under chronic N deposition. We show taxon-specific and community-wide declines of bacterial C and N uptake under chronic N deposition in both AM and ECM soils. N deposition-induced reductions in microbial activity were mirrored by declines in soil organic matter mineralization rates in AM but not ECM soils. Our findings suggest C and N uptake traits of bacterial communities can predict C cycling feedbacks to N deposition in AM soils, but additional data, for instance on the traits of fungi, may be needed to connect microbial traits with soil C and N cycling in ECM systems. In conclusion, our study also highlights the potential of employing qSIP in conjunction with trait-based analytical approaches to inform how ecological processes of microbial communities influence soil functioning.

59 BASIC BIOLOGICAL SCIENCES↗

Clinical Features of and Risk Factors for Fatal Ebola Virus Disease, Moyamba District, Sierra Leone, December 2014–February 2015

The current outbreak of Ebola virus disease (EVD) in West Africa has infected more than 28,000 people, killed more than 11,000 and disrupted social life. We studied retrospectively the clinical presentation and risk factors for fatal outcome among the 31 Ebola virus (EBV) positive patients admitted to the Ebola Treatment Center (ETC) in Moyamba District, Sierra Leone. We found a higher rate of bleeding manifestations than reported elsewhere during the current outbreak. Significant predictors for fatal outcome were shorter time from onset to admission, male sex, high viral load on initial lab test, severe pain, diarrhea, bloody stools, and development of other bleeding manifestations during hospital admission. Awareness of risk factors for fatal outcome could be used to identify patients in need of more intensive medical support. The lack of fever in as much as a third of EVD cases may have implications for temperature screening practices and case definitions.

60 APPLIED LIFE SCIENCES↗

Automatic calorimetry system monitors RF power

Calorimetry system monitors the average power dissipated in a high power RF transmitter. Sensors measure the change in temperature and the flow rate of the coolant, while a multiplier computes the power dissipated in the RF load.

Harness, B. W.↗

Aircraft control system

An aircraft control system is described which is particularly suited to rotary wing aircraft. Longitudinal acceleration and course rate commands are derived from a manual control stick to control translational velocity of the aircraft along a flight path. In the collective channel the manual controls provide vertical velocity commands. In the yaw channel the manual controls provide sideslip or heading rate commands at high or low airspeeds, respectively. The control system permits pilots to fly along prescribed flight paths in a precise manner with relatively low work load.

Rempfer, P. S.↗

Advances in Non-Contact Measurement of Creep Properties

As the required service temperatures for superalloys increases, so do the demands on testing for development of these alloys. Non-contact measurement of creep of refractory metals using electrostatic levitation has been demonstrated at temperatures up to 2300 C using samples of only 20-40 mg. These measurements load the spherical specimen by inertial forces due to rapid rotation. However, the first measurements relied on photon pressure to accelerate the samples to the high rotational rates of thousands of rotations per second, limiting the applicability to low stresses and high temperatures. Recent advances in this area extend this measurement to higher stresses and lower-temperatures through the use of an induction motor to drive the sample to such high rotational speeds. Preliminary results on new measurements on new materials will be presented.

Hyers, Robert↗

Fatigue crack growth rates of X100 steel welds in high pressure hydrogen gas considering residual stress effects

Fatigue crack growth rate (FCGR) data were measured in high pressure hydrogen gas versus stress intensity factor range (ΔK) in specimens removed from a X100 welded steel pipe. Three distinct regions of the pipe weld were examined: base metal, weld fusion zone, and heat affected zone. Tests were performed at a load ratio (R) of 0.5, frequency of 1 Hz, and at a hydrogen gas pressure of 21 MPa. Tests were also performed in air at 10 Hz as a reference. Fatigue crack growth rates were observed to be over an order of magnitude higher for tests performed in hydrogen compared to the rates from tests in air. Residual stress measurements were collected on identical specimens cut from the base metal, weld, and heat affected zone to account for their influence on measured FCGR data. The slitting method provided residual stress and residual stress intensity factor (K res ), the effect of which was removed from the FCGR data using K norm in order to provide a more direct comparison of crack growth resistance of the base metal, weld and heat affected zone. Prior to accounting for residual stress, FCGR in hydrogen gas appeared to be highest in the weld fusion zone. Furthermore, after accounting for residual stress effects, the weld fusion zone FCGR data converged to the base metal FCGR data, which underscores the importance of accounting for residual stress effects when assessing fatigue performance.

42 ENGINEERING↗

X-ray characterization of the micromechanical response ahead of a propagating small fatigue crack in a Ni-based superalloy

The small fatigue crack (SFC) growth regime in polycrystalline alloys is complex due to the heterogeneity in the local micromechanical fields, which result in high variability in crack propagation directions and growth rates. Here in this study, we employ a suite of techniques, based on high-energy synchrotron-based X-ray experiments that allow us to track a nucleated crack, propagating through the bulk of a Ni-based superalloy specimen during cyclic loading. Absorption contrast tomography is used to resolve the intricate 3D crack morphology and spatial position of the crack front. Initial near-field high-energy X-ray diffraction microscopy (HEDM) is used for high-resolution characterization of the grain structure, elucidating grain orientations, shapes, and boundaries. Cyclic loading is periodically interrupted to conduct far-field HEDM to determine the centroid position, average orientation, and average lattice strain tensor for each grain within the volume of interest. Reciprocal space analysis is used to further examine the deformation state of grains that plasticize in the vicinity of the crack. Analysis of the local micromechanical state in the grains ahead of the crack front is used to rationalize the advancing small crack path and growth rate. Specifically, the most active slip system in a grain, determined by the maximum resolved shear stress, aligns with the crack growth direction; and the degree of microplasticity ahead of the crack tip helps to identify directions for potential occurrences of crack arrest or propagation. The findings suggest that both the slip system level stresses and microplasticity events within grains are necessary to get a complete description of the SFC progression. Further, this detailed dataset, produced by a suite of X-ray characterization techniques, can provide the necessary validation, at the appropriate length-scale, for SFC models.

36 MATERIALS SCIENCE↗

DEVELOPMENT OF CRYSTAL-TOLERANT WASTE GLASSES

The loading of high-level waste in borosilicate glasses is limited by crystallinity constraints that cannot prevent crystal accumulation on the melter bottom and in the glass discharge riser of the melter. Pacific Northwest National Laboratory is studying variations in composition that are designed to constrain high-level waste glass compositions and develop the crystal-tolerant high-level waste glasses. These glasses will allow high waste loading without decreasing the lifetime of the melter by keeping the small spinel crystals suspended in the molten glass. Adding ~1 wt% of NiO to the baseline glass caused large spinel crystals to form up to 210 µm in size and resulted in the highest accumulation rate, ~ 227 mm/year, of all tested glasses. Noble metals that were added to high-Ni glass prevented large spinel crystals from forming and decreased the accumulation rate ~ 8.5 times. Adding ~5 wt% of Fe2O3 to the baseline glass resulted in a high number density of ~10-μm spinel crystals that remained suspended in the glass melt even after 17 days at 850°C. The accumulation rate of spinel crystals in high-chromia crucibles was only slightly higher compared with the accumulation rate in double crucibles. Only baseline glass exhibited about 2.6 times faster accumulation rate because of increased number of bigger crystals. These crystals were the result of glass enrichment with chromium that was leached out from the walls of high-chromia crucibles.

36 MATERIALS SCIENCE↗

Evaluation of Carbon Dioxide Capture From Existing Coal Fired Plants by Hybrid Sorption Using Solid Sorbents

A novel hybrid solid sorbent technology for CO₂ capture and separation from coal combustion-derived flue gas was evaluated. The technology – Capture of CO₂ by Hybrid Sorption (CACHYS™) – is a solid sorbent technology based on the following ideas: 1) reduction of energy for sorbent regeneration, 2) utilization of novel process chemistry, 3) contactor conditions that minimize sorbent-CO₂ heat of reaction and promote fast CO₂ capture, and 4) low-cost method of heat management. This report provides key information developed during the course of the project that includes sorbent performance, energy for sorbent regeneration, physical properties of the sorbent, the integration of process components, sizing of equipment, and overall capital and operational cost of the integrated CACHYS™ system. Seven sorbent formulations were prepared and evaluated at the lab-scale for energy requirements and CO₂ capture performance. Sorbent heat of regeneration ranged from 30-80 kJ/mol CO₂ and was found to be dependent on process conditions. Two sorbent formulations (designated HCK-4 & HCK-7) were down-selected for additional fixed-bed testing. Additional testing involved subjecting the sorbents to 100 continuous cycles in the fixed-bed reactor to determine performance as a function of time. The working capacity achieved for HCK-4 sorbent ranged from 5.5-8.0 g CO₂/100 g sorbent, while the HCK-7 typically ranged from 8.0-10.0 g CO₂/100 g sorbent. Overall, there was no deterioration in capacity with continuous cycling for either sorbent. The CACHYS™ bench-scale testing system designed and fabricated under this award consists of a dual circulating fluidized-bed adsorber and a moving-bed regenerator. The system takes a flue gas slipstream from the University of North Dakota’s coal-fired steam plant. Prior to being sent to the adsorber, the flue gas is scrubbed to remove SO₂ and particulate. During parametric testing of the adsorber, CO₂ capture achieved using the 2-bed configuration with recirculation in both beds was 65-70% with a high flue gas CO₂ loading (~7%) and up to 85% with a low flue gas CO₂ loading (~4%). A sorbent regenerator system consisting of a pre-heater, desorber, and cooler is used to heat the CO₂-rich sorbent with direct and indirect steam producing a nearly 100% pure stream of CO₂. Parametric testing of the regenerator system demonstrated the impact of process conditions on both desorption rate and the heat of regeneration. Clear evidence of the use of specific process conditions that lower the overall energy of desorption was identified. This observation validates measurements made at the laboratory-scale. Several longer-term continuous tests were conducted to evaluate the performance of the sorbent/process as a function of time. Using a 2-bed configuration, sustained capture efficiency of 40-60% with a high flue gas CO₂ loading (~8%) and 70-80% with a low flue gas CO₂ loading (~4%) were achieved. However, sorbent working capacity was found to be considerably lower than laboratory-scale measurements. The low working capacity is attributed to insufficient sorbent/gas contact time in the adsorber. Sorbent properties that had a significant impact on CO₂ capture performance were identified. The results show that controlling these sorbent properties substantially improves CO₂ capture performance, with preliminary estimates indicating that relative improvement of ~30% is possible. Testing culminated with an operationally trouble-free test of 15 hours with sustainable performance. Overall, several practical strategies to increase performance of the sorbent and process were identified. The initial technical and economic assessment of the CACHYS™ process estimated the cost of CO2 capture was $36.19/ton with a 48.6% increase in levelized cost of electricity (LCOE) for the 550 MWe net plant. Using additional data gathered over the course of the project, and with revised technical and economic assumptions, the estimated cost of CO₂ capture with the CACHYS™ process is $39/ton (only includes the cost of the CO2 capture system) with an increase in LCOE of 55.9%. Overall, CACHYS™ represents a significant improvement over the benchmark MEA system, and has demonstrated progress towards achieving DOE’s goals for CO₂ capture technologies.

01 COAL, LIGNITE, AND PEAT↗

Accelerating Improvements in the Energy Efficiency of Room Air Conditioners (RACs) in India: Potential, Cost-Benefit, and Policies (Interim Assessment)

Falling AC prices, increasing incomes, increasing urbanization, and high cooling requirements due to hot climate are all driving increasing uptake of Room Air Conditioners (RACs) in the Indian market. Air conditioning already comprises 40-60% of summer peak load in large metropolitan Indian cities such as Delhi and is likely to contribute 150 GW to the peak demand in 2030. Standards and labeling policies have contributed to improving the efficiency of RACs in India by about 2.5% in the last 10 years (2.5% per year) while inflation adjusted RAC prices have continued to decline. In this paper, we assess the technical feasibility, cost-benefit, and required policy enhancements by further accelerating the efficiency improvement of RACs in India. We find that there are examples of significantly more accelerated improvements such as those in Japan and Korea where AC efficiency improved by more than 7% per year resulting in almost a doubling of energy efficiency in 7 to 10 years while inflation adjusted AC prices continued to decline. We find that the most efficient RAC sold on the Indian market is almost twice as efficient as the typical AC sold on the market and hence see no technology constraints in a similar acceleration of improvement of efficiency. If starting 2018, AC efficiency improves at a rate of 6% instead of 3%, 40-60 GW of peak load (equivalent to connected load of 5-6 billion LED bulbs), and over 75 TWh/yr (equivalent to 60 million consumers consuming 100 kWh/month) will be saved by 2030; total peak load reduction would be as high as 50 GW. The net present value (NPV) of the consumer benefit between 2018-2030 will range from Rs 18,000 Cr in the most conservative case (in which prices don’t continue to decline and increase based estimates of today’s cost of efficiency improvement) to 140,000 Cr in a more realistic case (in which prices are not affected by accelerated efficiency improvement as shown by historical experience). This benefit is achievable by ratcheting up the 1 star level for fixed and inverter ACs to the level of today’s five star rating for inverter ACs by 2022. Bulk procurement (similar to the Domestic Efficient Lighting Program) and incentive programs can complement the accelerated ratcheting up of star levels. Similar programs can also be implemented for other types of ACs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced electrolytes for fast-charging high-voltage lithium-ion batteries in wide-temperature range

LiNixMnyCo1-x-yO2 (NMC) cathode materials with Ni=0.8 have attracted great interest for application in high energy-density lithium (Li)-ion batteries (LIBs) because of their high specific capacities at high voltages. However, the practical application of Ni-rich NMC in LIBs under high charge voltages (e.g. 4.4 V and above) still faces big challenges due to the severe capacity fading, which is directly related to the instability of the cathode/electrolyte interface. In this work, we develop new localized high-concentration electrolytes (LHCEs) based on carbonate solvents, which are compatible with graphite (Gr) anode and have a high oxidation potential over 4.9 V vs. Li/Li+. The optimal LHCE enables the Gr||NMC811 cells with 2.8 mAh cm-2 cathode areal capacity loading to achieve an excellent cycling stability over 600 cycles with a capacity retention of 94.2 % under a charge cut-off voltage of 4.4 V at 25 ?C, good rate capabilities under fast charging or discharging up to 3C rate, and superior low-temperature discharge performance down to -30 ?C with a capacity retention of 85.6% at C/5 rate. The findings in this work shed light a very promising strategy to develop new electrolytes for practical high-energy LIBs with Ni-rich NMC cathodes.

Zhang, Xianhui↗