Search NASA⌕ Search

SEARCH · Search NASA

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Recent advances in nano-scale spatial resolution x-ray microscopy instrumentation at NSLS-II

X-ray microscopy is an invaluable and powerful characterization tool applied in many scientific fields, such as materials science, biology, environmental science, and energy research. In recent years it has been driven by rapid developments of novel technologies and systems resulting in imaging experiments elucidating structural inhomogeneities and chemical reactions at the nanometer scale. To obtain high spatial resolution comprehensive chemical and structural information, an X-ray microscope must be equipped with adequate capabilities and allow for simultaneous acquisition of multiple datasets. In recent years, a number of X-ray microscopes have been designed, constructed, and commissioned at NSLS-II. Here we provide an overview of the microscopy instrumentation development program at NSLS-II and specifically focus on the multilayer Laue lens-based hard X-ray nanoprobe optimized for ~10 nm spatial resolution imaging, its current status, and future upgrades along with recently constructed Kirkpatrick-Baez based scanning microscope designed for ~100 nm spatial resolution experiments.

36 MATERIALS SCIENCE↗

Approaches to analyzing insulators with Auger Electron Spectroscopy: Update and Overview

This paper provides an updated overview, intended to be of practical value to analysts, of methods that can be applied to minimize or control the buildup of near surface electrical charge during electron induced Auger electron spectroscopy (AES). Although well developed methods can be highly effective, dealing with insulating or ungrounded samples for which high spatial resolution is needed remains a challenge. Examples of the application of methods involving low energy ion sources and sample thinning using a focused ion beam that can allow high resolution measurements on a variety of samples are highlighted. The physical bases of newer and traditional methods are simply described along with strengths and limitations of the methods. Summary tables indicate which methods apply to almost any spectrometer, which require special instrumental capabilities, and those that require special sample preparation or mounting.

36 MATERIALS SCIENCE↗

Wave optics simulations for new soft x-ray beamlines at NSLS-II

In this work, we performed fully- and partially-coherent synchrotron emission and propagation simulations with the "Synchrotron Radiation Workshop" computer code to analyze the performance of two soft X-ray beamlines under development at the National Synchrotron Light Source II: Soft X-ray Nanoprobe (SXN), and Angle-Resolved Photoemission Spectroscopy (ARPES) and Resonant Inelastic X-ray Scattering (RIXS) Imaging (ARI). The SXN beamline intends to provide high flux and high spatial resolution coherent soft X-ray imaging capabilities using both zone plate and lensless coherent imaging techniques. The ARI beamline aims to perform high flux ARPES and RIXS experiments with a focal spot size at the sample approaching 100 nm using highly-demagnifying mirrors in Kirkpatrick-Baez geometry. To accurately calculate the resolution and the degree of X-ray coherence provided by the two state-of-the-art beamlines, partial coherence effects are required to be taken into account in wave optics simulations for these two beamlines. In this talk, beamline performance parameters such as spot size, degree of coherence, flux, and energy resolution at the sample are presented. The effects of mirror surface slope errors on beamline performance were studied and some suggestions for further optimization are discussed.

36 MATERIALS SCIENCE↗

OpenMSI Arrayed Analysis Tools v2.0

Mass spectrometry imaging (MSI) enables high-resolution spatial mapping of biomolecules in samples and is a valuable tool for the analysis of tissues from plants and animals, microbial interactions, high-throughput screening, drug metabolism, and a host of other applications. This is accomplished by desorbing molecules from the surface on spatially defined locations, using a laser or ion beam. These ions are analyzed by a mass spectrometry and collected into a MSI 'image', a dataset containing unique mass spectra from the sampled spatial locations. MSI is used in a diverse and increasing number of biological applications. The OpenMSI Arrayed Analysis Tool (OMAAT) is a new software method that addresses the challenges of analyzing spatially defined samples in large MSI datasets, by providing support for automatic sample position optimization and ion selection.

BOWEN, BENJAMIN↗

Towards a deep characterization of a 64-fold-pixelated position sensitive detector for a new {gamma}-scanning system of HPGe segmented detectors

Characterization of the electrical response of the HPGe segmented detectors is one of the current goals for the Nuclear Physics community in order to perform {gamma}-ray tracking or even imaging with these detectors. For this purpose, scanning devices have to be developed to achieve the signal-position association with the highest precision. In this laboratory, a new scanning system, SALSA (Salamanca Lyso-based Scanning Array), consisting on a high spatial resolution {gamma} camera, is a under development. In this work the whole scanning system is presented and first results for the characterization of the {gamma} camera are shown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NACHOS, a CubeSat-based high-resolution UV-Visible hyperspectral imager for remote sensing of trace gases: system overview and science objectives

Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

More Frequent and Persistent Heatwaves Due To Increased Temperature Skewness Projected by a High‐Resolution Earth System Model

Abstract Heatwaves are strongly associated with temperature distributions, but the mechanisms by which distributions are influenced by climate change remains unclear. Comparing simulations from a high‐spatial resolution Community Earth System Model (CESM‐HR) with those from low‐resolution models, we identify substantial improvements by CESM‐HR in reproducing observed Northern Hemisphere summer temperature skewness, as well as the frequency, intensity, persistence, and total heatwave days. Temperature skewness is strongly linked to land‐atmosphere interactions and atmospheric circulation. Under global warming projections, some regions exhibit enhanced temperature skewness, along with more frequent and persistent heatwaves of greater intensity. We find that in energy‐limited regimes, such as India, negative skewness in latent heat flux facilitates large positive skewness in sensible heat flux, which modulates near‐surface air temperatures. Skewness differences of latent and sensible heat fluxes are amplified under global warming, increasing the temperature skewness. We find that this contrasting flux mechanism is active in several heatwave‐prone regions.

Gao, Yang↗

Inflatable Antenna Microwave Radiometer for Soil Moisture Measurement

Microwave measurements of soil moisture are not being obtained at the required spatial Earth resolution with current technology. Recently, new novel designs for lightweight reflector systems have been developed using deployable inflatable antenna structures which could enable lightweight real-aperture radiometers. In consideration of this, a study was conducted at the NASA Langley Research Center (LaRC) to determine the feasibility of developing a microwave radiometer system using inflatable reflector antenna technology to obtain high spatial resolution radiometric measurements of soil moisture from low Earth orbit and which could be used with a small and cost effective launch vehicle. The required high resolution with reasonable swath width coupled with the L-band measurement frequency for soil moisture dictated the use of a large (30 meter class) real aperture antenna in conjunction with a pushbroom antenna beam configuration and noise-injection type radiometer designs at 1.4 and 4.3 GHz to produce a 370 kilometer cross-track swath with a 10 kilometer resolution that could be packaged for launch with a Titan 2 class vehicle. This study includes design of the inflatable structure, control analysis, structural and thermal analysis, antenna and feed design, radiometer design, payload packaging, orbital analysis, and electromagnetic losses in the thin membrane inflatable materials.

Bailey, M. C.↗

Water-Rock Interactions in Outer Solar System Bodies: Evidence from the Coordinated Analysis of Interplanetary Dust

NASA has an ongoing program of collecting interplanetary dust particles (IDPs) in the stratosphere using high altitude research aircraft. The collected IDPs are derived from asteroids and comets and here we report studies of a subset of hydrated IDPs rich in carbonaceous matter that are proposed to have a cometary origin. Our studies are aimed at understanding the evolution of oxygen reservoirs in the Solar System and their interaction with cometary minerals and organic matter. The small size (<20 μm) and fragility of these IDPs present a number of analytical challenges. We have pioneered techniques for performing chemical, mineralogical, isotopic, and spectroscopic measurements on the same sample in a carefully coordinated sequence. Coordinated analyses of nanogram-size samples is made possible by several delicate sample preparation techniques. To avoid organic contamination, we embed IDPs in elemental sulfur and use ultramicrotomy to partly section the particles (the first few micrometers). Multiple thin sections (50-70 nm thick) are placed on different substrates depending on the analysis technique. We use a JEOL 2500SE scanning, transmission electron microscope (STEM) to determine the mineralogy, microstructure, and elemental compositions of constituent minerals in the thin sections through a combination of high resolution imaging, electron diffraction, quantitative energy-dispersive x-ray mapping, and electron energy-loss spectroscopy. Following the STEM analyses, we use a NanoSIMS 50L for high spatial resolution isotopic measurements of H, C, N, and O to search for presolar grains and to understand the origin of the indigenous organic matter. The isotopic analyses are performed on the same sections analyzed in the STEM in order to correlate isotopic properties with the elemental and mineralogical data. We reserve other thin sections for non-destructive analyses utilizing synchrotron-based techniques including Fourier-transform infrared (FTIR) micro-spectroscopy and X-ray absorption near-edge structure (XANES) analyses, especially for functional group analysis of organic matter in the particles. The remainder of the IDP is extracted from the sulfur bead that was used for microtomy and is pressed into Au foil for quantitative analysis (including light elements) using a JEOL 8530F field emission electron probe microanalyzer (EPMA). After the EPMA measurements, high precision oxygen isotopic analyses are obtained using Cameca IMS1270/1290 instruments at UCLA. The hydrated IDPs in this study are dominated by saponitic clays, with minor magnetite, carbonate and abundant organic matter. The remarkable oxygen isotopic compositions, high carbon contents, and the abundance of isotopically anomalous organic matter, together suggest that the high carbon, hydrated IDPs are derived from primitive sources not yet represented in meteorite collections such as outer main belt P- and D-type asteroids or comets.

Keller, Lindsay P.↗

Tip-Enhanced Raman Chemical and Chemical Reaction Imaging in H 2 O with Sub-3-nm Spatial Resolution

Reproducible chemical and chemical reaction nano-imaging at solid-liquid interfaces remains challenging, particularly when resolutions on the order of a few nm are sought after. In this work, we demonstrate the latter through liquid tip-enhanced Raman (TER) measurements that target gold nanoplates functionalized with 4-mercaptobenzonitrile (MBN). In addition to chemical imaging and local optical field nano-visualization with high spatial resolution, we observe the signatures of 4-mercaptobenzoic acid, which forms as a result of plasmon-induced hydrolysis of MBN. Evidently, the solvent leads to distinct plasmon-induced/enhanced chemical reaction pathways that have not been documented. Here this work shows that such reactions that take place at solid-liquid interfaces can be tracked with a record sub-3 nm spatial resolution via TER spectral nano-imaging in liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRANSMISSION ELECTRON MICROSCOPY OF Al-RICH SILICATE STARDUST FROM ASYMPTOTIC GIANT BRANCH STARS

We report on transmission electron microscopy (TEM) investigations of two mineralogically unusual stardust silicates to constrain their circumstellar condensation conditions. Both grains were identified by high spatial resolution nano secondary ion mass spectrometry (NanoSIMS) in the Acfer 094 meteorite, one of the most pristine carbonaceous chondrites available for study. One grain is a highly crystalline, highly refractory (Fe content < 0.5 at%), structurally undisturbed orthopyroxene (MgSiO{sub 3}) with an unusually high Al content (1.8 {+-} 0.5 at%). This is the first TEM documentation of a single crystal pyroxene within the complete stardust silicate data set. We interpret the microstructure and chemistry of this grain as being a direct condensate from a gas of locally non-solar composition (i.e., with a higher-than-solar Al content and most likely also a lower-than-solar Mg/Si ratio) at (near)-equilibrium conditions. From the overabundance of crystalline olivine (six reported grains to date) compared to crystalline pyroxene (only documented as a single crystal in this work) we infer that formation of olivine over pyroxene is favored in circumstellar environments, in agreement with expectations from condensation theory and experiments. The second stardust silicate consists of an amorphous Ca-Si rich material which lacks any crystallinity based on TEM observations in which tiny (<20 nm) hibonite nanocrystallites are embedded. This complex assemblage therefore attests to the fast cooling and rapidly changing chemical environments under which dust grains in circumstellar shells form.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hailstorm Analyses and Detection Derived from Current and Historical Satellite Data and Convective Environmental Parameters

We seek to demonstrate the extent to which hailstorms can be detected using a combination of geostationary (GEO) visible and infrared metrics of storm intensity and convective environmental parameters from reanalysis. Hailstorm identifications from low-Earth-orbiting (LEO) passive microwave sensors and maximum expected size of hail (MESH) from ground-based radar serve as a proxy for hail events. Data are analyzed for two warm seasons over the contiguous United States (CONUS). A neural network (NN) is trained to predict hailstorm detection dependent on optimal multi-variate weighting of observed and modeled input. The NN results are then applied to a 15-year Meteosat Second Generation climatology over South Africa to depict where hailstorms are most likely to occur. We also explore the impact of GEO imager resolution on our ability to discriminate hailstorms by matching GOES-13 (4 km) and GOES-16 (2 km) storm intensity metrics against hail characteristics using LEO, MESH, and spotter reports over CONUS during 2017, when both satellites were simultaneously imaging. Such analysis allows us to assess the feasibility of assembling a severe storm climate data record back to GOES-8, in the mid-1990’s. Finer spatial resolution of GOES-16 better resolves the updraft characteristics and intensities that are inherently linked to hail formation; however, GOES-13 can be normalized to achieve comparable detection capability. When intelligently combined with model-derived convective environmental parameters, GEO-derived storm intensity metrics enable high-spatial resolution hail risk assessment at hourly intervals throughout the diurnal cycle anywhere around the world and an improved understanding of hailstorms in the climate system.

Kyle F Itterly↗

Sub-pixel spatial resolution wavefront phase imaging

A phase imaging method for an optical wavefront acquires a plurality of phase images of the optical wavefront using a phase imager. Each phase image is unique and is shifted with respect to another of the phase images by a known/controlled amount that is less than the size of the phase imager's pixels. The phase images are then combined to generate a single high-spatial resolution phase image of the optical wavefront.

Stahl, H. Philip↗

Noninvasive Imaging of a Liquid Jet

Liquid jets are found in many applications, from printing to manufacturing to entertainment. Herein this study uses three different noninvasive imaging modalities to compare resulting images of a liquid jet operating at three Reynolds numbers that cover laminar, transitional, and turbulent flow. Selected measurement quantities from each image type are also compared. High-speed backlit (BL) imaging is a simple imaging technique found in many laboratories, and this is compared to two high-speed X-ray imaging techniques, white beam (WB) imaging and focused beam (FB) radiography. BL imaging can provide a wide field of view and is easy to implement, but it only shows the presence or absence of liquid. WB imaging can show detailed contours on the surface of the liquid jet, but the imaging region is much smaller. FB radiography produces a point-source measurement and can provide the quantitative, instantaneous local liquid path length, termed the equivalent path length (EPL). All three techniques provide similar measures of jet thickness, with the FB measurements having less variation. FB measurements can also provide detailed cross sections of the average liquid jet thickness at high spatial resolutions.

42 ENGINEERING↗

Phase retrieval using polychromatic illumination for transmission X-ray microscopy

An alternative method for quantitative phase retrieval in a transmission X-ray microscope system at sub-50-nm resolution is presented. As an alternative to moving the sample in the beam direction in order to analyze the propagation-introduced phase effect, we have illuminated the TXM using X-rays of different energy without any motor movement in the TXM system. Both theoretical analysis and experimental studies have confirmed the feasibility and the advantage of our method, because energy tuning can be performed with very high energy resolution using a double crystal monochromator at a synchrotron beam line, and there is zero motor error in TXM system in our approach. High-spatial-resolution phase retrieval is accomplished using the proposed method.

47 OTHER INSTRUMENTATION↗

Visualization of Thermal and Strain Dynamics in X-ray Optics by Time-Resolved Rocking Curve Imaging

The absorption of intense X-ray pulses from free-electron lasers by X-ray crystal optics triggers rapid thermal and mechanical responses, including lattice compression, expan- sion, and strain-wave propagation, which dynamically modify diffraction conditions and wavefront properties. These effects pose significant challenges for next-generation high- repetition-rate X-ray sources, particularly for crystal monochromators used in XFEL beam- lines and self-seeding. Here, we demonstrate time-resolved rocking curve imaging (TrRCI) of X-ray Bragg optics with high spatial resolution (6.4 μm) and sub-1-μrad angular resolu- tion, enabling direct visualization of lattice dynamics from nanoseconds to microseconds. By combining a high-flux beamline at SPring-8, a scintillator-coupled sCMOS detector, and a synchronized femtosecond laser system, we capture lattice dynamics induced by tran- sient laser heating with a strain sensitivity on the order of 10−6 . Our results reveal transient lattice deformation and the propagation of laser-induced strain waves over millimeter-scale distances. This approach provides experimental benchmarks for understanding heat-load effects in high-repetition-rate X-ray optics.

Source record↗

Performance and characterization of the prototype nm-scale spatial resolution scanning multilayer Laue lenses microscope

Synchrotron based x-ray microscopy established itself as a prominent tool for noninvasive investigations in many areas of science and technology. Many facilities around the world routinely achieve sub-micrometer resolution with a few instruments capable of imaging with the spatial resolution better than 100 nm. With an ongoing effort to push the 2D/3D resolution down to 10 nm in the hard x-ray regime both fabrication of the nano-focusing optics and stability of a microscope become extremely challenging. In this work we present our approach to overcome technical challenges on the path towards high spatial resolution hard x-ray microscopy and demonstrate the performance of a scanning fluorescence microscope equipped with the multilayer Laue lenses focusing optics.

36 MATERIALS SCIENCE↗

Pushing the limits: characterisation and performance of the prototype multilayer Laue lenses fluorescence microscope with a view to achieve nm-scale spatial resolution

Synchrotron based x-ray microscopy established itself as a prominent tool for noninvasive investigations in many areas of science and technology. Many facilities around the world routinely achieve sub-micrometer resolution with a few instruments capable of imaging with the spatial resolution better than 100 nm. With an ongoing effort to push the 2D/3D resolution down to 10 nm in the hard x-ray regime both fabrication of the nano-focusing optics and stability of a microscope become extremely challenging. In this work we present our approach to overcome technical challenges on the path towards high spatial resolution hard x-ray microscopy and demonstrate the performance of a scanning fluorescence microscope equipped with the multilayer Laue lenses focusing optics. We utilised the Imaging and Coherence beamline (I13) at Diamond Light Source to perform X-ray testing of the scanning microscope.

36 MATERIALS SCIENCE↗