Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Cavity Ring-Down System for Density Measurement of Negative Hydrogen Ion on Negative Ion Source

A Cavity Ring-Down (CRD) system was applied to measure the density of negative hydrogen ion (H{sup -}) in vicinity of extraction surface in the H{sup -} source for the development of neutral beam injector on Large Helical Device (LHD). The density measurement with sampling time of 50 ms was carried out. The measured density with the CRD system is relatively good agreement with the density evaluated from extracted beam-current with applying a similar relation of positive ion sources. In cesium seeded into ion-source plasma, the linearity between an arc power of the discharge and the measured density with the CRD system was observed. Additionally, the measured density was proportional to the extracted beam current. These characteristics indicate the CRD system worked well for H{sup -} density measurement in the region of H{sup -} and extraction.

43 PARTICLE ACCELERATORS↗

Particle model of full-size ITER-relevant negative ion source

This work represents the first attempt to model the full-size ITER-relevant negative ion source including the expansion, extraction, and part of the acceleration regions keeping the mesh size fine enough to resolve every single aperture. The model consists of a 2.5D particle-in-cell Monte Carlo collision representation of the plane perpendicular to the filter field lines. Magnetic filter and electron deflection field have been included and a negative ion current density of j{sub H{sup −}} = 660 A/m{sup 2} from the plasma grid (PG) is used as parameter for the neutral conversion. The driver is not yet included and a fixed ambipolar flux is emitted from the driver exit plane. Results show the strong asymmetry along the PG driven by the electron Hall (E × B and diamagnetic) drift perpendicular to the filter field. Such asymmetry creates an important dis-homogeneity in the electron current extracted from the different apertures. A steady state is not yet reached after 15 μs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of plasma meniscus formation and beam halo in negative ion source using the 3D3VPIC model

In this paper, the effect of the electron confinement time on the plasma meniscus and the fraction of the beam halo is investigated by 3D3V-PIC (three dimension in real space and three dimension in velocity space) (Particle in Cell) simulation in the extraction region of negative ion source. The electron confinement time depends on the characteristic time of electron escape along the magnetic field as well as the characteristic time of diffusion across the magnetic field. Our 3D3V-PIC results support the previous result by 2D3V-PIC results i.e., it is confirmed that the penetration of the plasma meniscus becomes deep into the source plasma region when the effective confinement time is short.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of the shear flow on electron cyclotron resonance plasma confinement in an axisymmetric magnetic mirror trap of the electron cyclotron resonance ion source

Influence of shear flows of the dense plasma created under conditions of the electron cyclotron resonance (ECR) gas breakdown on the plasma confinement in the axisymmetric mirror trap (''vortex'' confinement) was studied experimentally and theoretically. A limiter with bias potential was set inside the mirror trap for plasma rotation. The limiter construction and the optimal value of the potential were chosen according to the results of the preliminary theoretical analysis. This method of ''vortex'' confinement realization in an axisymmetric mirror trap for non-equilibrium heavy-ion plasmas seems to be promising for creation of ECR multicharged ion sources with high magnetic fields, more than 1 T.

43 PARTICLE ACCELERATORS↗

Study of the Plasma near the Plasma Electrode by Probes and Photodetachment in ECR-driven Negative Ion Source

The effect of the plasma electrode bias on the plasma characteristics near the extraction aperture in a large volume hybrid multicusp negative ion source, driven by 2.45 GHz microwaves, is reported. Spatially resolved negative ion and electron density measurements were performed under various pressures (1-4 mTorr) by means of electrostatic probe and photodetachment technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the negative ion extraction mechanism from a double-ion plasma in negative ion sources

We have developed a 2D3V-PIC model of the extraction region, aiming to clarify the basic extraction mechanism of H{sup −} ions from the double-ion plasma in H{sup −} negative ion sources. The result shows the same tendency of the H{sup −} ion density n{sub H{sup −}} as that observed in the experiments, i.e.,n{sub H{sup −}} in the upstream region away from the plasma meniscus (H{sup −} emitting surface) has been reduced by applying the extraction voltage. At the same time, relatively slow temporal oscillation of the electric potential compared with the electron plasma frequency has been observed in the extraction region. Results of the systematic study using a 1D3V-PIC model with the uniform magnetic field confirm the result that the electrostatic oscillation is identified to be lower hybrid wave. The effect of this oscillation on the H{sup −} transport will be studied in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrogen hollow cathode ion source

A source of hydrogen ions is disclosed and includes a chamber having at one end a cathode which provides electrons and through which hydrogen gas flows into the chamber. Screen and accelerator grids are provided at the other end of the chamber. A baffle plate is disposed between the cathode and the grids and a cylindrical baffle is disposed coaxially with the cathode at the one end of the chamber. The cylindrical baffle is of greater diameter than the baffle plate to provide discharge impedance and also to protect the cathode from ion flux. An anode electrode draws the electrons away from the cathode. The hollow cathode includes a tubular insert of tungsten impregnated with a low work function material to provide ample electrons. A heater is provided around the hollow cathode to initiate electron emission from the low work function material.

Mirtich, M. J., Jr.↗

Sealed operation of a rf driven ion source for a compact neutron generator to be used for associated particle imaging

We present the recent development of a prototype compact neutron generator to be used in conjunction with the method of associated particle imaging for the purpose of active neutron interrogation. In this paper, the performance and device specifications of these compact generators that employ rf driven ion sources will be discussed. Initial measurements of the generator performance include a beam spot size of 1 mm in diameter and a neutron yield of 2x10{sup 5} n/s with air cooling.

43 PARTICLE ACCELERATORS↗

Numerical analysis of electronegative plasma in the extraction region of negative hydrogen ion sources

This numerical study focuses on the physical mechanisms involved in the extraction of volume-produced H{sup -} ions from a steady state laboratory negative hydrogen ion source with one opening in the plasma electrode (PE) on which a dc-bias voltage is applied. A weak magnetic field is applied in the source plasma transversely to the extracted beam. The goal is to highlight the combined effects of the weak magnetic field and the PE bias voltage (upon the extraction process of H{sup -} ions and electrons). To do so, we focus on the behavior of electrons and volume-produced negative ions within a two-dimensional model using the particle-in-cell method. No collision processes are taken into account, except for electron diffusion across the magnetic field using a simple random-walk model at each time step of the simulation. The results show first that applying the magnetic field (without PE bias) enhances H{sup -} ion extraction, while it drastically decreases the extracted electron current. Secondly, the extracted H{sup -} ion current has a maximum when the PE bias is equal to the plasma potential, while the extracted electron current is significantly reduced by applying the PE bias. The underlying mechanism leading to the above results is the gradual opening by the PE bias of the equipotential lines towards the parts of the extraction region facing the PE. The shape of these lines is due originally to the electron trapping by the magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Frequency Microwaves Plasma Production for Active Profile Control of Ion Beams on a Large Bore ECR Ion Source with Permanent Magnets

A new concept on magnetic field of plasma production and confinement by using permanent magnets, i.e. cylindrically comb-shaped magnets, has been proposed to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure and also the low microwave power. The resonance zones corresponding to the fundamental ECR for 2.45 GHz and 11-13 GHz frequency are constructed at different positions. The profiles of the plasma parameters in the ECR ion source are different from each frequency of microwave. Large bore extractor is set at the opposite side against the microwave feeds. It is found that differences of their profiles also appear at those of ion beam profiles. We conducted to launch simultaneously multiplex frequency microwaves controlled individually, and tried to control the profiles of the plasma parameters and then those of extracted ion beam.

43 PARTICLE ACCELERATORS↗

Bayesian Optimization of Non-Invariant Systems with Constraints Developed for Application to the ECR Ion Source VENUS

In this work, we consider the optimization of non-invariant systems with both safety and control constraints. We present a new approach based on Bayesian optimization for the dynamic, safe and controlled optimization of such systems. Although there are other possible use cases, we focus on the application to the electron cyclotron resonance ion source VENUS. From experimental data, we have observed that VENUS behaves to first order as a non-invariant dynamic system with moving areas of instability. Our novel approach aims at providing a tool that can maintain system optimization in a safe way. This is accomplished by making sure the objective function, the beam current in the case of VENUS, does not fall under an operational minimum, while simultaneously requiring the optimization to avoid areas where VENUS is unstable. We compare the result of our approach on synthetic data modeled to mimic the behavior of VENUS with two methods from the literature, a standard Bayesian optimizer and a safe Bayesian optimizer, both adapted to deal with dynamic systems. A cross Student T-test is conducted to show the significance of the improvement given by the new method we introduce here, regarding the two preexisting methods we compared to. The results of the tests conducted on synthetic data show that the proposed method succeeds at maintaining the system optimized and obeys the predefined constraints better than the literature methods explored.

Bayesian optimization↗

Creation and recovery of a W(111) single atom gas field ion source

Tungsten single atom tips have been prepared from a single crystal W(111) oriented wire using the chemical assisted field evaporation and etching method. Etching to a single atom tip occurs through a symmetric structure and leads to a predictable last atom unlike etching with polycrystalline tips. The single atom tip formation procedure is shown in an atom by atom removal process. Rebuilds of single atom tips occur on the same crystalline axis as the original tip such that ion emission emanates along a fixed direction for all tip rebuilds. This preparation method could be utilized and developed to prepare single atom tips for ion source development.

36 MATERIALS SCIENCE↗

Ion source design for industrial applications

The more frequently used design techniques for the components of broad-beam electron bombardment ion sources are discussed. The approach used emphasizes refractory metal cathodes and permanent-magnet multipole discharge chambers. Design procedures and sample calculations are given for the discharge chamber, ion optics, the cathodes, and the magnetic circuit. Hardware designs are included for the isolator, cathode supports, anode supports, pole-piece assembly, and ion-optics supports. A comparison is made between two-grid and three-grid optics. The designs presented are representative of current technology and are adaptable to a wide range of configurations.

Kaufman, H. R.↗

Multiple delivery cesium oven system for negative ion sources

Distribution of cesium in large negative ion beam sources to be operational in ITER, is presently based on the use of three or more cesium ovens, which operate simultaneously and are controlled remotely. However, use of multiple Cs ovens simultaneously is likely to pose difficulties in operation and maintenance of the ovens. An alternate method of Cs delivery, based on a single oven distribution system is proposed as one which could reduce the need of simultaneous operation of many ovens. A proof of principle experiment verifying the concept of a multinozzle distributor based Cs oven has been carried out at Institute for Plasma Research. It is also observed that the Cs flux is not controlled by Cs reservoir temperature after few hours of operation but by the temperature of the distributor which starts behaving as a Cs reservoir.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Production of C-14 and Stable Ion Beams at the Argonne Tandem Linac Accelerator System with the ECR3 Ion Source

The Argonne Tandem Linac Accelerator System (ATLAS) at Argonne National Laboratory (ANL) paused production of carbon-14 ion beams with the removal of the Tandem Van de Graaff in 2013. Installation of ECR3, an Electron Cyclotron Resonance Ion Source, returned that production capability to ATLAS, with the first C-14 beam delivered in December 2020. Information is presented on C-14 beam current, gas consumption and N-14 filtering techniques using stripping foils at different sections of ATLAS. ECR3 also fulfilled the operational goal of adding flexibility to ATLAS stable beam production capabilities. Beneficial impacts to ATLAS operation, beam development and experimental programs are discussed.

Scott, R. H.↗

Loss of atomic oxygen in mass spectrometer ion sources.

A gas beam consisting of a mixture of atomic and molecular oxygen has been directed at the ion source of a mass spectrometer like those used in sounding rockets for determining the neutral composition of the lower thermosphere. The loss of atomic oxygen on mass spectrometer surfaces was evaluated by flagging the beam in several ways and comparing the experimental results with predicted values. The results obtained suggest that in rocket flights using similar instruments the atomic oxygen densities computed assuming no-loss conditions may be low by a factor of 2.5. Studies made using a beam containing tracer O-18 indicate that carbon dioxide observed when atomic oxygen enters the source is formed in a reaction involving atomic oxygen from the beam and carbon monoxide from the surfaces bombarded.

Lake, L. R.↗

Prospects for advanced electron cyclotron resonance and electron beam ion source charge breeding methods for EURISOL

As the most ambitious concept of isotope separation on line (ISOL) facility, EURISOL aims at producing unprecedented intensities of post-accelerated radioactive isotopes. Charge breeding, which transforms the charge state of radioactive beams from 1+ to an n+ charge state prior to post-acceleration, is a key technology which has to overcome the following challenges: high charge states for high energies, efficiency, rapidity and purity. On the roadmap to EURISOL, a dedicated R and D is being undertaken to push forward the frontiers of the present state-of-the-art techniques which use either electron cyclotron resonance or electron beam ion sources. We describe here the guidelines of this R and D.

43 PARTICLE ACCELERATORS↗