Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

WE-DE-BRA-07: Megavoltage Spectral Imaging with a Layered Detector

Purpose: The aim of the current work is to investigate the feasibility of megavoltage spectral imaging using a multiple layered detector for enhancement of low contrast detectability through material segmentation and discrimination (such as bone, markers and metal implants). Potentially the technique can be applied to improve detection and reduce dose in Megavoltage Cone Beam Computed Tomography (MV-CBCT). Methods: Experiments were performed with a prototype multi-layer imager (MLI) which has higher detective efficiency and lower noise characteristics than conventional Electronic Portal Imaging Devices (EPIDs). Images of a solid water phantom were acquired at 2.5 MV, 6MV and 6MV without flattening filter (FFF). The following materials were placed within a stack of solid water: aluminum, copper and gold. Material separation was assessed based on Contrast-to-Noise Ratio (CNR) of the weighted image, formed by a weighted subtraction of the images from two layers of the MLI. A range of weighting factors were investigated for material separation. Results: CNR can be minimized for each material by appropriate selection of the subtraction weighting factor. This is equivalent to a selective subtraction of specific materials from the image. Using multiple layers simultaneously also decreases the dose requirement and removes any registration errors. The minimum CNR for aluminum, copper and gold at the weighted image formed with 2.5MV was obtained at weighting factors equal to 0.92, 0.76 and 0.64 respectively. The corresponding values at 6MVFFF were 0.99, 0.92 and 0.78 respectively. Conclusion: In the current work, an MV spectral imaging feasibility study was attempted using a novel multi-layer prototype EPID imager. Initial results suggest that material separation based on spectral differences between different layers is possible. This spectral imaging technique has potential advantages in MV-CBCT for real-time target tracking, patient set-up imaging and adaptive radiotherapy. The project was supported, partially, by a grant from Varian Medical Systems, Inc., and Award No. R01CA188446-01 from the National Cancer Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Cancer Institute or the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-02: A Preliminary Study Evaluating Beam-Hardening Artifact Reduction On CT Direct Electron-Density Images

Purpose: A prototype reconstruction algorithm that can provide direct electron density (ED) images from single energy CT scans is being currently developed by Siemens Healthcare GmbH. This feature can eliminate the need for kV specific calibration curve for radiation treatemnt planning. An added benefit is that beam-hardening artifacts are also reduced on direct-ED images due to the underlying material decomposition. This study is to quantitatively analyze the reduction of beam-hardening artifacts on direct-ED images and suggest additional clinical usages. Methods: HU and direct-ED images were reconstructed on a head phantom scanned on a Siemens Definition AS CT scanner at five tube potentials of 70kV, 80kV, 100kV, 120kV and 140kV respectively. From these images, mean, standard deviation (SD), and local NPS were calculated for regions of interest (ROI) of same locations and sizes. A complete analysis of beam-hardening artifact reduction and image quality improvement was conducted. Results: Along with the increase of tube potentials, ROI means and SDs decrease on both HU and direct-ED images. The mean value differences between HU and direct-ED images are up to 8% with absolute value of 2.9. Compared to that on HU images, the SDs are lower on direct-ED images, and the differences are up to 26%. Interestingly, the local NPS calculated from direct-ED images shows consistent values in the low spatial frequency domain for images acquired from all tube potential settings, while varied dramatically on HU images. This also confirms the beam -hardening artifact reduction on ED images. Conclusions: The low SDs on direct-ED images and relative consistent NPS values in the low spatial frequency domain indicate a reduction of beam-hardening artifacts. The direct-ED image has the potential to assist in more accurate organ contouring, and is a better fit for the desired purpose of CT simulations for radiotherapy.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-10: Tumor Metabolic Control Probability & Dose Response Mapping for Adaptive Dose Painting by Number

Purpose: Adaptive dose-painting-by-number (DPbN) requires a dose-response-mapping (DRM) obtained early in the treatment course. To obtain DRM, voxel-by-voxel tumor dose response needs to be quantified. Our recent study has demonstrated that voxel-by-voxel radio-sensitivity of patient tumor can be determined using tumor-metabolic-ratio measured early during the treatment using FDG-PET images. In this study, the measurements were utilized to construct tumor metabolic control probability (TMCP) and DRM for DPbN. Methods: FDG-PET/CT images of 18 HN cancer patients obtained pre- and weekly during the treatment were used. Spatial parametric images of tumor-metabolic-ratio (dSUV) were constructed following voxel-by-voxel deformable image registration. Each voxel value in dSUV was a function of baseline SUV and delivered dose. Utilizing all values of dSUV in the controlled tumor group at the last treatment week, a cut-off function between the baseline SUV and dSUV was formed, and applied in early treatment days on dSUV of all tumors to model the TMCP. At the treatment week k, TMCP was constructed with respect to the tumor voxel dSUV appeared at the week using the maximum likelihood estimation for all dose levels, and used for DRM construction. Results: TMCPs estimated in the week 2 & 3 have D{sub 50}=11.1∼47.6Gy; γ{sub 50}=0.55∼0.92 respectively with respect to dSUV=0.3∼1.2. The corresponding DRM between tumor voxel dSUV and the expected treatment dose has sigmoid shape. The expected treatment dose are 26∼40Gy (for 95% TMCP) for high sensitive tumor voxels with dSUV=0.3∼0.5; and 65∼110Gy for low sensitive tumor voxels with the dSUV>1.0 depending on the time of the estimation. Conclusion: TMCP can be constructed voxel-by-voxel in human tumor using multiple FDG-PET imaging obtained in early treatment days. TMCP provides a potential quantitative objective of tumor DRM for DPbN to plan the best dose, escalate or de-escalate, in tumor adaptively based on its own radio-sensitivity.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRA-04: Individually Optimized Contrast-Enhanced 4D-CT for Radiotherapy Simulation in Pancreatic Ductal Adenocarcinoma

Purpose: To develop an individually optimized contrast-enhanced (CE) 4D-CT for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). Methods: Ten PDA patients were enrolled. Each underwent 3 CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT using test injection. Three physicians contoured the tumor and pancreatic tissues. We compared image quality scores, tumor volume, motion, tumor-to-pancreas contrast, and contrast-to-noise ratio (CNR) in the 3 CTs. We also evaluated interobserver variations in contouring the tumor using simultaneous truth and performance level estimation (STAPLE). Results: Average image quality scores for CE 3DCT and CE 4D-CT were comparable (4.0 and 3.8, respectively; P=0.47), and both were significantly better than that for 4D-CT (2.6, P<0.001). Tumor-to-pancreas contrast results were comparable in CE 3D-CT and CE 4D-CT (15.5 and 16.7 HU, respectively; P=0.71), and the latter was significantly higher than in 4D-CT (9.2 HU, P=0.03). Image noise in CE 3D-CT (12.5 HU) was significantly lower than in CE 4D-CT (22.1 HU, P<0.001) and 4D-CT (19.4 HU, P=0.005). CNRs were comparable in CE 3D-CT and CE 4DCT (1.4 and 0.8, respectively; P=0.23), and the former was significantly better than in 4D-CT (0.6, P = 0.04). Mean tumor volumes were smaller in CE 3D-CT (29.8 cm{sup 3}) and CE 4D-CT (22.8 cm{sup 3}) than in 4D-CT (42.0 cm{sup 3}), although these differences were not statistically significant. Mean tumor motion was comparable in 4D-CT and CE 4D-CT (7.2 and 6.2 mm, P=0.23). Interobserver variations were comparable in CE 3D-CT and CE 4D-CT (Jaccard index 66.0% and 61.9%, respectively) and were worse for 4D-CT (55.6%) than CE 3D-CT. Conclusion: CE 4D-CT demonstrated characteristics comparable to CE 3D-CT, with high potential for simultaneously delineating the tumor and quantifying tumor motion with a single scan. Supported in part by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Optimal structure and parameter learning of Ising models

Reconstruction of the structure and parameters of an Ising model from binary samples is a problem of practical importance in a variety of disciplines, ranging from statistical physics and computational biology to image processing and machine learning. The focus of the research community shifted toward developing universal reconstruction algorithms that are both computationally efficient and require the minimal amount of expensive data. Here, we introduce a new method, interaction screening, which accurately estimates model parameters using local optimization problems. The algorithm provably achieves perfect graph structure recovery with an information-theoretically optimal number of samples, notably in the low-temperature regime, which is known to be the hardest for learning. Here, the efficacy of interaction screening is assessed through extensive numerical tests on synthetic Ising models of various topologies with different types of interactions, as well as on real data produced by a D-Wave quantum computer. Finally, this study shows that the interaction screening method is an exact, tractable, and optimal technique that universally solves the inverse Ising problem.

97 MATHEMATICS AND COMPUTING↗

Femtojoule optical nonlinearity for deep learning with incoherent illumination

Optical neural networks (ONNs) are a promising computational alternative for deep learning due to their inherent massive parallelism for linear operations. However, the development of energy-efficient and highly parallel optical nonlinearities, a critical component in ONNs, remains an outstanding challenge. Here, we introduce a nonlinear optical microdevice array (NOMA) compatible with incoherent illumination by integrating the liquid crystal cell with silicon photodiodes at the single-pixel level. We fabricate NOMA with more than half a million pixels, each functioning as an optical analog of the rectified linear unit at ultralow switching energy down to 100 femtojoules per pixel. With NOMA, we demonstrate an optical multilayer neural network. Our work holds promise for large-scale and low-power deep ONNs, computer vision, and real-time optical image processing.

36 MATERIALS SCIENCE↗

Imaging in Diagnostic Nuclear Medicine

Single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are modern methods for visualization in diagnostic nuclear medicine. SPECT is known as a workhorse in cardiology, and PET is the gold standard in oncology. The development of nuclear medicine is provided by cooperation of physicists, mathematicians, biologists, medical doctors, and radio-chemists. In spite of extensive clinical applications, several problems may lead to false diagnoses. In particular, the correction of attenuation of gamma radiation in human organs must be taken into account. For interpretation and evaluation of such an effect on the clinical results, we perform physico-mathematical simulation of the SPECT diagnostics in cardiology in the absence and presence of the correction of attenuation. A brief review of the state-of-the art is presented. The simulation employs the first Russian anthropomorphic mathematical phantom that describes the distribution of radio-pharmacological agent ({sup 99m }Tc-methoxyisobutylisonitrile) in chest organs of a typical male patient. A model for calculation of raw images is developed with allowance for attenuation of radiation in biological tissues and the effect of collimator and detector. The results of the proposed models and calculated images are compared with clinical images obtained at the Meshalkin Institute of Circulation Pathology (Novosibirsk) and Myasnikov Institute of Clinical Cardiology (Moscow). Statistical algorithms are developed for the solution of the inverse problem of image reconstruction based on the entropy principle. The clinical and physico-mathematical approaches are compared in the evaluation of the effect of correction on the quality of reconstructed images of the left ventricle of myocardium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Noise-Resilient and Reduced Depth Approximate Adders for NISQ Quantum Computing

The "Noisy intermediate-scale quantum" NISQ machine era primarily focuses on mitigating noise, controlling errors, and executing high-fidelity operations, hence requiring shallow circuit depth and noise robustness. Approximate computing is a novel computing paradigm that produces imprecise results by relaxing the need for fully precise output for error-tolerant applications including multimedia, data mining, and image processing. We investigate how approximate computing can improve the noise resilience of quantum adder circuits in NISQ quantum computing. We propose five designs of approximate quantum adders to reduce depth while making them noise-resilient, in which three designs are with carryout, while two are without carryout. We have used novel design approaches that include approximating the Sum only from the inputs (pass-through designs) and having zero depth, as they need no quantum gates. The second design style uses a single CNOT gate to approximate the SUM with a constant depth of O(1). We performed our experimentation on IBM Qiskit on noise models including thermal, depolarizing, amplitude damping, phase damping, and bitflip: (i) Compared to exact quantum ripple carry adder without carryout the proposed approximate adders without carryout have improved fidelity ranging from 8.34% to 219.22%, and (ii) Compared to exact quantum ripple carry adder with carryout the proposed approximate adders with carryout have improved fidelity ranging from 8.23% to 371%. Further, the proposed approximate quantum adders are evaluated in terms of various error metrics.

Gaur, Bhaskar↗

Sandia Simple Particle Tracking (Sandia SPT) v. 1.0

Sandia SPT is designed as software to accompany a book chapter being published a methods chapter which provides an introduction on how to label and track individual proteins. The Sandia Simple Particle Tracking code uses techniques common to the image processing community, where its value is that it facilitates implementing the methods described in the book chapter by providing the necessary open-source code. The code performs single particle spot detection (or segmentation and localization) followed by tracking (or connecting the detected particles into trajectories). The book chapter, which along with the headers in each file, constitutes the documentation for the code is: Anthony, S.M.; Carroll-Portillo, A.; Timlon, J.A., Dynamics and Interactions of Individual Proteins in the Membrane of Living Cells. In Anup K. Singh (Ed.) Single Cell Protein Analysis Methods in Molecular Biology. Springer

Anthony, StephenM.↗

Sparx PCA Module

Sparx, a new environment for Cryo-EM image processing; Cryo-EM, Single particle reconstruction, principal component analysis; Hardware Req.: PC, MAC, Supercomputer, Mainframe, Multiplatform, Workstation. Software Req.: operating system is Unix; Compiler C++; type of files: source code, object library, executable modules, compilation instructions; sample problem input data. Location/transmission: http://sparx-em.org; User manual & paper: http://sparx-em.org;

Yang, Chao↗

Multi-Energy Differential Evolution Reconstruction (MEnDER 1D) for Proton Deflectometry

This code is designed to reconstruct magnetic field deflections, and thus the path-integrated magnetic field, from sets of proton images at two distinct proton probe energies. A differential evolution (DE) algorithm is used to iteratively update a population of solution candidates of the magnetic deflections of the protons for reconstructing the input images, selecting improved candidates as they are discovered. This algorithm was written using MATLAB (R2019a) and makes use of the Image Processing and Parallel Processing Toolboxes.

Levesque, Joseph↗

DefectSegNet

DefectSegNet for semantic segmentation of defects in Steels The first and most important step of automating defect analysis is perceptual defect identification. In terms of digital image processing, semantic segmentation best emulates human recognition of defect features – it identifies the crystallographic defects and where they are located in a TEM micrograph. We solved this problem by developing DefectSegNet, a novel hybrid CNN algorithm for robust and automated semantic segmentation of three crystallographic defects, including line dislocations, precipitates and voids, that are commonly observed in structural metals and alloys.

Sainju, Rajat↗

FLIT: A Generic Fortran Library based on Interfaces and Templates

This Fortran code consists of multiple modules with a focus on simplifying array operations, image processing, and numerical computation especially for computational geophysics applications. We intend to use this code to demonstrate the application and usefulness of Fortran interface and templates for generic programming, especially for computational geophysics and seismology applications. The code has several notable features. Firstly, it is based on a modularized structure, where each module contains multiple functions but with a focus of functionality. Secondly, it heavily uses interfaces and templates for improving the genericness and convenience of the resulting code, where a same function interface can enclose a group of functions that perform the same functionality but with inputs/output variables of different data types. Thirdly, it includes a variety of generic functions with an emphasis on array operations, such as rotation, flipping, cropping, padding, fast Fourier transform, Gaussian blurring, interpolation, and so on. We name this package FLIP – a generic Fortran Library based on Interfaces and Templates.

Gao, Kai↗

Computing with Spikes: The Advantage of Fine-Grained Timing

Neural-inspired spike-based computing machines often claim to achieve considerable advantages in terms of energy and time efficiency by using spikes for computation and communication. However, fundamental questions about spike-based computation remain unanswered. For instance, how much advantage do spike-based approaches have over conventional methods, and under what circumstances does spike-based computing provide a comparative advantage? Simply implementing existing algorithms using spikes as the medium of computation and communication is not guaranteed to yield an advantage. Here, we demonstrate that spike-based communication and computation within algorithms can increase throughput, and they can decrease energy cost in some cases. We present several spiking algorithms, including sorting a set of numbers in ascending/descending order, as well as finding the maximum or minimum or median of a set of numbers. We also provide an example application: a spiking median-filtering approach for image processing providing a low-energy, parallel implementation. Furthermore, the algorithms and analyses presented here demonstrate that spiking algorithms can provide performance advantages and offer efficient computation of fundamental operations useful in more complex algorithms.

97 MATHEMATICS AND COMPUTING↗

The effect of transient needle lift on the internal flow and near-nozzle spray characteristics for modern GDI systems investigated by high-speed X-ray imaging

The development of the injector nozzle is a dynamic area in regard of several technical aspects. At first, the internal flow influences the near-field spray characteristics via various phenomena such as cavitation and turbulence. However, these phenomena are not fully understood due to their extremely fast, complex and multiscale nature. Furthermore, it governs the spray targeting inside the combustion chamber. High-speed X-ray imaging of GDI injector nozzles is performed in this study. The experimental results presented are related to the internal flow and primary breakup of discharged liquid jets. The injectors used are equipped with nozzles made of aluminum which have been specially developed for these investigations to enhance optical accessibility. The visualization of the needle motion, in-nozzle flow and the primary breakup region provides several exciting observations. First, the needle lift tracking exhibits short overshooting right before the steady-state of the injection phase. Additionally, this event leads to a short-term, however, significant change in the associated performance of the breakup. This phenomenon is found to be a consequence of the transient behavior of the in-nozzle flow. It is shown that under some circumstances hydraulic flip may occur during this overshooting period. The primary jet breakup region is visualized and evaluated by means of image processing. Thus, the transient behavior of liquid jet expansion is quantified in the vicinity of the nozzle. It is observed that the liquid jet direction deviates from the hole axis already at the nozzle outlet, which is caused by internal flow characteristics.

42 ENGINEERING↗

Extreme ultraviolet mask roughness effects in high numerical aperture lithography

Given the reflective nature of extreme ultraviolet lithography and its extremely short operational wavelength, roughness of the optical surfaces is of significant concern. In particular, roughness in the mask multilayer leads to image plane speckle and ultimately patterned line-edge or line-width variability in the imaging process. Here we consider the implications of this effect for future high numerical aperture (NA) systems that are assumed to require anamorphic magnification projection optics. The results show significant anisotropic behavior at high NA as well as a substantial increase in relative patterned line variability in the shadowed direction when comparing 0.55 NA to 0.33 NA, despite the assumption of an anamorphic magnification system. In conclusion, the shadowed-direction patterned line variability is 2× larger than for unshadowed lines, and the majority of the increase in variability occurs in the low frequency regime.

47 OTHER INSTRUMENTATION↗

Full Karyotype Interphase Cell Analysis

Aneuploidy seems to play not only a decisive role in embryonal development but also in tumorigenesis where chromosomal and genomic instability reflect a universal feature of malignant tumors. The cost of whole genome sequencing has fallen significantly, but it is still prohibitive for many institutions and clinical settings. No applied, cost-effective, and efficient technique has been introduced yet aiming at research to assess the ploidy status of all 24 different human chromosomes in interphases simultaneously, especially in single cells. Here, we present the selection of human probe DNA and a technique using multistep fluorescence in situ hybridization (FISH) employing four sets of six labeled FISH probes able to delineate all 24 human chromosomes in interphase cells. This full karyotype analysis approach will provide additional diagnostic potential for single cell analysis. The use of spectral imaging (SIm) has enabled the use of up to eight different fluorochrome labels simultaneously. Thus, scoring can be easily assessed by visual inspection, because SIm permits computer-assigned and distinguishable pseudo-colors to each probe during image processing. This enables full karyotype analysis by FISH of single-cell interphase nuclei.

Baumgartner, Adi↗