Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Using SPHINX Accelerator to Measure Heat Transfer in Metal Foils [Slides]

Experiments on the SPHINX accelerator at Sandia National Laboratories (SNL) looked at electron beam heating of metal foils used in Bremsstrahlung flash x-ray production. Titanium and tantalum foils were exposed to electron beam energies of up to 2MeV to determine surface heating. As part of the experiment, the x-ray dose profiles were characterized using a scintillating panel (EJ-230) placed both perpendicular and parallel to the photon beam. This was followed by direct electron beam imaging using a fast-gated ICCD camera and a fused silica Cherenkov witness plate. Once characterized, the foil was directly measured using a mid-wave (3-5 micron) infrared camera (MWIR) to determine the peak surface temperatures and spatially-resolved thermal profiles. Additionally, an IR pyrometer was used in a single wavelength mode (2.3 µm) to determine localized surface temperatures as well. Results are compared with calculations of surface temperatures obtained from e-beam energy depositions combined with the specific heats of the foils. This is the first attempt to directly measure the surface temperature profile on a short-pulse (10 nanoseconds) flash x-ray source using MWIR imaging. These data are directly relevant for Monte Carlo/Integrated Tiger Series electron/photon transport code results being used in the design of future Bremsstrahlung sources such as CREST.

43 PARTICLE ACCELERATORS↗

SWinzip v. 1.0

SWinzip is a Matlab and C++ library for scientific lossy data compression and reconstruction using compressed sensing and tree-wavelets transforms. These methods are known for their large compression and usefulness in data analytics such as features extraction. Compressed sensing and wavelets methods rely heavily on sparse and dense linear algebra operations implemented through the Boost codes in our library. SWinzip accommodates data represented on both regular grids (e.g. image data) and point-clouds (e.g. unstructured meshes).

Salloum, Maher↗

Malware analysis and recovery

A system and method detects malware by processing notifications from an intrusion detection system and baseline snapshots from an image capture utility. The image capture utility constructs an image of the suspected malware intrusion and links the suspected malware intrusion to the baseline snapshots. The system and method propagates the image of the suspected malware intrusion across multiple networks before it distinguishes malicious code, device state, and files from benign code, device state, and files. Some systems and methods include a malware recovery system that executes machine learning instructions and heuristics to revert a client and/or a remote server to one or more baseline snapshots.

Smith, Jared M.↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-334: Dosimetric Impacts of Organ at Risk (OAR) Contour Errors in Prostate Volumetric Modulated Arc Therapy (VMAT) Planning: A Sensitivity Study

Purpose: To investigate the dosimetric impacts of OAR contour errors in prostate VMAT planning with a sensitivity analysis method. Methods: Ten randomly selected prostate VMAT patients were used to simulate OAR contour error in rectum and bladder. For each OAR 12 even spaced contour control points were selected in every three slices. For each simulation, only one of the control points was simulated to move inwards or outwards by up to 6 voxels and coordinates of adjacent voxels to that moving control point were moved accordingly with a 3D-spline smooth function. An in-house software was used to predict OARs dosimetric endpoints based on geometric relationship between PTV and OAR. In this study, the V75, V70, V65, V60 of rectum and V80, V75, V70, V65 of bladder with and without perturbed contours were calculated and compared. Results: The percentage of OAR dose volume difference around the reference OAR contours were plotted as iso-error lines overlaid on CT images. The significant difference was shown in OAR contours adjacent to the PTV where high dose gradient exists. When one of the 12 points adjacent to the PTV moved up to 6 voxels, maximum errors of 1.99%, 2.46%, 2.89%, and 3.19% were found in V75, V70, V65, and V60 of the rectum, and 1.59%, 1.67%, 1.87%, and 1.90% were found in V80, V75, V70, and V65 of the bladder, respectively. Conclusion: We can quantify the dosimetric impact of OAR contouring error by evaluating the percentage of OAR dose volume changes in prostate VMAT planning. For the adaptive radiation therapy, the iso-error lines can provide the planner a guideline that which portion of contour needed to be checked carefully because dosimetric sensitivity of contour errors are different for different part of contours.

60 APPLIED LIFE SCIENCES↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-TeP3-03: Dose Enhancement of Gold Nanoparticle in Proton Therapy: A Monte Carlo Study Based On the Transmission Electron Microscopy Imaging

Purpose: Gold nanoparticle (GNP) is a promising radiosensitizer that selectively boosts tumor dose in radiotherapy. Transmission electron microscopy (TEM) imaging observations recently revealed for the first time that GNP exists in vivo in the form of highly localized vesicles, instead of hypothetical uniform distribution. This work investigates the corresponding difference of energy deposition in proton therapy. Methods: First, single vesicles of various radii were constructed by packing GNPs (as Φ50 nm gold spheres) in spheres and were simulated, as well as a single GNP. The radial energy depositions (REDs) were scored using 100 concentric spherical shells from 0.1µm to 10µm, 0.1µm thickness each, for both vesicles and GNP, and compared. TEM images, 8 days after injection in a PC3 prostate cancer murine model, were used to extract position/dimension of vesicles, as well as contours of cytoplasmic and nucleus membranes. Vesicles were then constructed based on the TEM images. A 100 MeV proton beam was studied by using the Geant4-DNA code, which simulates all energy deposition events. Results: The vesicle REDs, normalized to the same proton energy loss as in a single GNP, are larger (smaller) than that of a single GNP when radius >2µm (<2µm). The peak increase (at about 3µm radius) is about 10% and 18% for Φ1µm and Φ1.6µm vesicles respectively, relative to a single GNP. The TEM-based simulation resulted in a larger energy deposition (by about one order of magnitude) that follows completely different pattern from that of hypothetical GNP distributions (regular dotted pattern in extracellular and/or extranucleus regions). Conclusion: The in vivo energy deposition, both in pattern and magnitude, of proton therapy is greatly affected by the true distribution of the GNP, as illustrated by the presence of GNP vesicles compared to hypothetical scenarios. Work supported by NSERC Discovery Grant #435510, Canada.

60 APPLIED LIFE SCIENCES↗

SU-E-T-32: A Feasibility Study of Independent Dose Verification for IMAT

Purpose: To assess the feasibility of the independent dose verification (Indp) for intensity modulated arc therapy (IMAT). Methods: An independent dose calculation software program (Simple MU Analysis, Triangle Products, JP) was used in this study, which can compute the radiological path length from the surface to the reference point for each control point using patient’s CT image dataset and the MLC aperture shape was simultaneously modeled in reference to the information of MLC from DICOM-RT plan. Dose calculation was performed using a modified Clarkson method considering MLC transmission and dosimetric leaf gap. In this study, a retrospective analysis was conducted in which IMAT plans from 120 patients of the two sites (prostate / head and neck) from four institutes were retrospectively analyzed to compare the Indp to the TPS using patient CT images. In addition, an ion-chamber measurement was performed to verify the accuracy of the TPS and the Indp in water-equivalent phantom. Results: The agreements between the Indp and the TPS (mean±1SD) were −0.8±2.4% and −1.3±3.8% for the regions of prostate and head and neck, respectively. The measurement comparison showed similar results (−0.8±1.6% and 0.1±4.6% for prostate and head and neck). The variation was larger in the head and neck because the number of the segments was increased that the reference point was under the MLC and the modified Clarkson method cannot consider the smooth falloff of the leaf penumbra. Conclusion: The independent verification program would be practical and effective for secondary check for IMAT with the sufficient accuracy in the measurement and CT-based calculation. The accuracy would be improved if considering the falloff of the leaf penumbra.

60 APPLIED LIFE SCIENCES↗

SU-E-T-162: Characterization of a New Oblong Cone for Use with the Intraoperative Mobetron Unit

Purpose: To evaluate the dosimetric characteristics of a new flat 7 cm x 12 cm oblong cone for intraoperative radiation therapy (IORT) procedures. Methods: Percent depth dose (PDD) curves and profile measurements at dose depths of D100, D90, D80, D50, and D30 were measured using a parallel-plate ion chamber and a 3-D water tank Blue phantom II (iba) for the three energies (6, 9, and 12 MeV) available with the new generation Mobetron 2000. In addition, PDD curves and profiles were made with Gafchromic EBT3 films in solid water phantom. H&D curves were created for each energy for absolute calibration. The films were analyzed using the RIT image analysis software and then compared with the ion chamber results. Output values were obtained by normalizing the dose/MU at D100 at the clinical axis of the oblong cone by the dose/MU at D100 for the flat 10cm cylindrical standard cone using ion chamber measurements. Results: Ion chamber results show that the PDDs from the flat oblong cone, at the clinical axis, match with the PDDs for its “cylindrical brother” 7cm flat cone. These PDDs are comparable with those from the 10cm standard cone. The D100 coincides for all three energies. The cone output factors for the oblong cone are 1.07 for all energies. Ion chamber profiles measurements and film analysis show that the use of flat oblong cone with the 6 and 9 MeV energies Result in horns of approximately 12% and 8%, respectively. Conversely, 12 MeV profiles show loss of flatness near the field edge. Conclusion: The potential advantage of the oblong cones is the elimination of the well-known difficulties of electron field matching, both dosimetrically and in clinical setup.

60 APPLIED LIFE SCIENCES↗

Measurement and simulation of ICRF wave intensity with a recalibrated phase contrast imaging diagnostic on Alcator C-Mod

Waves in the ion cyclotron range of frequencies (ICRF) are one of the major tools to heat fusion plasmas. Full-wave simulations are essential to predict the wave propagation and absorption quantitatively, and it is important that these codes be validated against actual experimental measurements. In this work, the absolute intensity of the ICRF waves previously measured with a phase contrast imaging diagnostic was recalibrated and compared once more with full-wave predictions. In the earlier work, significant discrepancies were found between the measured and the simulated mode converted wave intensity [N. Tsujii et al., Phys. Plasmas 19, 082508]. With the new calibration of the detector array, the measured mode converted wave intensity is now in much better agreement with the full-wave predictions. The agreement is especially good for comparisons performed close to the antenna.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time X-ray phase-contrast imaging using SPINNet—a speckle-based phase-contrast imaging neural network

X-ray phase-contrast imaging has become indispensable for visualizing samples with low absorption contrast. In this regard, speckle-based techniques have shown significant advantages in spatial resolution, phase sensitivity, and implementation flexibility compared with traditional methods. However, the computational cost associated with data inversion has hindered their wider adoption. By exploiting the power of deep learning, we developed a speckle-based phase-contrast imaging neural network (SPINNet) that significantly improves the imaging quality and boosts the phase retrieval speed by at least 2 orders of magnitude compared to existing methods. To achieve this performance, we combined SPINNet with a coded-mask-based technique, an enhanced version of the speckle-based method. Using this scheme, we demonstrate the simultaneous reconstruction of absorption and phase images on the order of 100 ms, where a traditional correlation-based analysis would take several minutes even with a cluster. In addition to significant improvement in speed, our experimental results show that the imaging and phase retrieval quality of SPINNet outperform existing single-shot speckle-based methods. Furthermore, we successfully demonstrate SPINNet application in x-ray optics metrology and 3D x-ray phase-contrast tomography. Our result shows that SPINNet could enable many applications requiring high-resolution and fast data acquisition and processing, such as in situ and in operando 2D and 3D phase-contrast imaging and real-time at-wavelength metrology and wavefront sensing.

36 MATERIALS SCIENCE↗

Software-controlled, highly automated intrafraction prostate motion correction with intrafraction stereographic targeting: System description and clinical results

Purpose: A new system for software-controlled, highly automated correction of intrafraction prostate motion,'' intrafraction stereographic targeting'' (iSGT), is described and evaluated. Methods: At our institute, daily prostate positioning is routinely performed at the start of treatment beam using stereographic targeting (SGT). iSGT was implemented by extension of the SGT software to facilitate fast and accurate intrafraction motion corrections with minimal user interaction. iSGT entails megavoltage (MV) image acquisitions with the first segment of selected IMRT beams, automatic registration of implanted markers, followed by remote couch repositioning to correct for intrafraction motion above a predefined threshold, prior to delivery of the remaining segments. For a group of 120 patients, iSGT with corrections for two nearly lateral beams was evaluated in terms of workload and impact on effective intrafraction displacements in the sagittal plane. Results: SDs of systematic ({Sigma}) and random ({sigma}) displacements relative to the planning CT measured directly after initial SGT setup correction were <0.5 and <0.8 mm, respectively. Without iSGT corrections, effective {Sigma} and {sigma} for the 11-min treatments would increase to {Sigma}{sub eff} < 1.1 mm and {sigma}{sub eff} < 1.2 mm. With the iSGT procedure with an action level of 4 mm, effective positioning errors were reduced to {Sigma}{sub eff} < 0.8 mm and {sigma}{sub eff} < 1.0 mm, with 23.1% of all fractions requiring a correction. Computer simulations demonstrated that with an action level of 2 mm, the errors would have been reduced to {Sigma}{sub eff} < 0.6 mm and {sigma}{sub eff} < 0.7 mm, requiring corrections in 82.4% of the fractions. Because iSGT is highly automated, the extra time added by iSGT is <30 s if a correction is required. Conclusions: Without increasing imaging dose, iSGT successfully reduces intrafraction prostate motion with minimal workload and increase in fraction time. An action level of 2 mm is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of an on-board imaging system for extremely rapid radiation therapy

Purpose: Next-generation extremely rapid radiation therapy systems could mitigate the need for motion management, improve patient comfort during the treatment, and increase patient throughput for cost effectiveness. Such systems require an on-board imaging system that is competitively priced, fast, and of sufficiently high quality to allow good registration between the image taken on the day of treatment and the image taken the day of treatment planning. In this study, three different detectors for a custom on-board CT system were investigated to select the best design for integration with an extremely rapid radiation therapy system. Methods: Three different CT detectors are proposed: low-resolution (all 4 × 4 mm pixels), medium-resolution (a combination of 4 × 4 mm pixels and 2 × 2 mm pixels), and high-resolution (all 1 × 1 mm pixels). An in-house program was used to generate projection images of a numerical anthropomorphic phantom and to reconstruct the projections into CT datasets, henceforth called “realistic” images. Scatter was calculated using a separate Monte Carlo simulation, and the model included an antiscatter grid and bowtie filter. Diagnostic-quality images of the phantom were generated to represent the patient scan at the time of treatment planning. Commercial deformable registration software was used to register the diagnostic-quality scan to images produced by the various on-board detector configurations. The deformation fields were compared against a “gold standard” deformation field generated by registering initial and deformed images of the numerical phantoms that were used to make the diagnostic and treatment-day images. Registrations of on-board imaging system data were judged by the amount their deformation fields differed from the corresponding gold standard deformation fields—the smaller the difference, the better the system. To evaluate the registrations, the pointwise distance between gold standard and realistic registration deformation fields was computed. Results: By most global metrics (e.g., mean, median, and maximum pointwise distance), the high-resolution detector had the best performance but the medium-resolution detector was comparable. For all medium- and high-resolution detector registrations, mean error between the realistic and gold standard deformation fields was less than 4 mm. By pointwise metrics (e.g., tracking a small lesion), the high- and medium-resolution detectors performed similarly. For these detectors, the smallest error between the realistic and gold standard registrations was 0.6 mm and the largest error was 3.6 mm. Conclusions: The medium-resolution CT detector was selected as the best for an extremely rapid radiation therapy system. In essentially all test cases, data from this detector produced a significantly better registration than data from the low-resolution detector and a comparable registration to data from the high-resolution detector. The medium-resolution detector provides an appropriate compromise between registration accuracy and system cost.

60 APPLIED LIFE SCIENCES↗

SU-C-202-03: A Tool for Automatic Calculation of Delivered Dose Variation for Off-Line Adaptive Therapy Using Cone Beam CT

Purpose: Monitoring the delivered dose is an important task for the adaptive radiotherapy (ART) and for determining time to re-plan. A software tool which enables automatic delivered dose calculation using cone-beam CT (CBCT) has been developed and tested. Methods: The tool consists of four components: a CBCT Colleting Module (CCM), a Plan Registration Moduel (PRM), a Dose Calculation Module (DCM), and an Evaluation and Action Module (EAM). The CCM is triggered periodically (e.g. every 1:00 AM) to search for newly acquired CBCTs of patients of interest and then export the DICOM files of the images and related registrations defined in ARIA followed by triggering the PRM. The PRM imports the DICOM images and registrations, links the CBCTs to the related treatment plan of the patient in the planning system (RayStation V4.5, RaySearch, Stockholm, Sweden). A pre-determined CT-to-density table is automatically generated for dose calculation. Current version of the DCM uses a rigid registration which regards the treatment isocenter of the CBCT to be the isocenter of the treatment plan. Then it starts the dose calculation automatically. The AEM evaluates the plan using pre-determined plan evaluation parameters: PTV dose-volume metrics and critical organ doses. The tool has been tested for 10 patients. Results: Automatic plans are generated and saved in the order of the treatment dates of the Adaptive Planning module of the RayStation planning system, without any manual intervention. Once the CTV dose deviates more than 3%, both email and page alerts are sent to the physician and the physicist of the patient so that one can look the case closely. Conclusion: The tool is capable to perform automatic dose tracking and to alert clinicians when an action is needed. It is clinically useful for off-line adaptive therapy to catch any gross error. Practical way of determining alarming level for OAR is under development.

60 APPLIED LIFE SCIENCES↗

SU-F-R-07: Radiomics of CT Features and Associations and Correlation with Outcomes Following Lung SBRT

Objective: To investigate the prognostic significance of image gradients and in predicting clinical outcomes in a patients with non-small cell lung cancer treated with stereotactic body radiotherapy (SBRT) on 71 patients with 83 treated lesions. Methods: The records of patients treated with lung SBRT were retrospectively reviewed. When applicable, SBRT target volumes were modified to exclude any overlap with pleura, chestwall, or mediastinum. The ITK software package was utilized to generate quantitative measures of image intensity, inhomogeneity, shape morphology and first and second-order CT textures. Multivariate and univariate models containing CT features were generated to assess associations with clinicopathologic factors. Results: On univariate analysis, tumor size (HR 0.54, p=0.045) sumHU (HR 0.31, p=0.044) and short run grey level emphasis STD (HR 0.22, p=0.019) were associated with regional failure-free survival; meanHU (HR 0.30, p=0.035), long run emphasis (HR 0.21, p=0.011) and long run low grey level emphasis (HR 0.14, p=0.005) was associated with distant failure-free survival (DFFS). No features were significant on multivariate modeling however long run low grey level emphasis had a hazard ratio of 0.12 (p=0.061) for DFFS. Adenocarcinoma and squamous cell carcinoma differed with respect to long run emphasis STD (p=0.024), short run low grey level emphasis STD (p<0.001), and long run low grey level emphasis STD (p=0.024). Multivariate modeling of texture features associated with tumor histology was used to estimate histologies of 18 lesions treated without histologic confirmation. Of these, MVA suggested the same histology as a prior metachronous lung malignancy in 3/7 patients. Conclusion: Extracting radiomics features on clinical datasets was feasible with the ITK package with minimal effort to identify pre-treatment quantitative CT features with prognostic factors for distant control after lung SBRT.

60 APPLIED LIFE SCIENCES↗

Three-dimensional Image Fusion Guidance for Transjugular Intrahepatic Portosystemic Shunt Placement

IntroductionTo assess the safety, feasibility and effectiveness of image fusion guidance with pre-procedural portal phase computed tomography with intraprocedural fluoroscopy for transjugular intrahepatic portosystemic shunt (TIPS) placement.Materials and methodsAll consecutive cirrhotic patients presenting at our interventional unit for TIPS creation from January 2015 to January 2016 were prospectively enrolled. Procedures were performed under general anesthesia in an interventional suite equipped with flat panel detector, cone-beam computed tomography (CBCT) and image fusion technique. All TIPSs were placed under image fusion guidance. After hepatic vein catheterization, an unenhanced CBCT acquisition was performed and co-registered with the pre-procedural portal phase CT images. A virtual path between hepatic vein and portal branch was made using the virtual needle path trajectory software. Subsequently, the 3D virtual path was overlaid on 2D fluoroscopy for guidance during portal branch cannulation. Safety, feasibility, effectiveness and per-procedural data were evaluated.ResultsSixteen patients (12 males; median age 56 years) were included. Procedures were technically feasible in 15 of the 16 patients (94%). One procedure was aborted due to hepatic vein catheterization failure related to severe liver distortion. No periprocedural complications occurred within 48 h of the procedure. The median dose-area product was 91 Gy cm{sup 2}, fluoroscopy time 15 min, procedure time 40 min and contrast media consumption 65 mL. Clinical benefit of the TIPS placement was observed in nine patients (56%).ConclusionThis study suggests that 3D image fusion guidance for TIPS is feasible, safe and effective. By identifying virtual needle path, CBCT enables real-time multiplanar guidance and may facilitate TIPS placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-G-BRA-05: Predicting Volume Change of the Tumor and Critical Structures Throughout Radiation Therapy by CT-CBCT Registration with Local Intensity Correction

Purpose: The purpose of this study is to develop an accurate and effective technique to predict and monitor volume changes of the tumor and organs at risk (OARs) from daily cone-beam CTs (CBCTs). Methods: While CBCT is typically used to minimize the patient setup error, its poor image quality impedes accurate monitoring of daily anatomical changes in radiotherapy. Reconstruction artifacts in CBCT often cause undesirable errors in registration-based contour propagation from the planning CT, a conventional way to estimate anatomical changes. To improve the registration and segmentation accuracy, we developed a new deformable image registration (DIR) that iteratively corrects CBCT intensities using slice-based histogram matching during the registration process. Three popular DIR algorithms (hierarchical B-spline, demons, optical flow) augmented by the intensity correction were implemented on a graphics processing unit for efficient computation, and their performances were evaluated on six head and neck (HN) cancer cases. Four trained scientists manually contoured nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs for each case, to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial software, VelocityAI (Varian Medical Systems Inc.). Results: Manual contouring showed significant variations, [-76, +141]% from the mean of all four sets of contours. The volume differences (mean±std in cc) between the average manual segmentation and four automatic segmentations are 3.70±2.30(B-spline), 1.25±1.78(demons), 0.93±1.14(optical flow), and 4.39±3.86 (VelocityAI). In comparison to the average volume of the manual segmentations, the proposed approach significantly reduced the estimation error by 9%(B-spline), 38%(demons), and 51%(optical flow) over the conventional mutual information based method (VelocityAI). Conclusion: The proposed CT-CBCT registration with local CBCT intensity correction can accurately predict the tumor volume change with reduced errors. Although demonstrated only on HN nodal GTVs, the results imply improved accuracy for other critical structures. This work was supported by NIH/NCI under grant R42CA137886.

60 APPLIED LIFE SCIENCES↗

SU-E-T-136: Dosimetric Robustness of a Magnetic Resonance Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the radiation delivery robustness of the first MR-IGRT system using a commercial cylindrical diode array detector (ArcCHECK) and an ionization thimble chamber (Exradin A18). Methods: The MR-IGRT system is composed of three evenly spaced Co-60 sources on a rotating gantry located between two magnet halves. The collimator for each source consists of 30 doubly-focused leaf pairs that allow the system to deliver both conformal and intensity modulated (IMRT) treatment plans. The system's delivery robustness was tested over a span of 6 months from September 2013 through February 2014. This was achieved by repeatedly delivering 10 patient plans. These plans consisted of 2 conformal prostates, 2 IMRT prostates, 2 IMRT head and neck, 2 IMRT breast, 1 IMRT pancreas, and 1 IMRT bladder. The plans were generated with the system's treatment planning software. Once the plans were generated, quality assurance plans were created on a digital ArcCHECK dataset. The ArcCHECK used for testing was specially designed to be MR-compatible by moving the power supply outside of the magnetic field. The A18 ionization chamber was placed in a custom plastic plug insert in the center of the ArcCHECK. Gamma analysis was used with the ArcCHECK for relative dose evaluating both 3%/3mm and 2%/2mm. Absolute point dose was compared between ion chamber measurement and treatment plan. Results: The ArcCHECK passing rate remained constant over the 6 month period. The average passing rate for 3%/3mm and 2%/2mm analysis was 98.6% ± 0.7 and 88.8% ± 2.9, respectively. The ion chamber measurements showed little variation with an average percent difference between planned dose verses measured dose of 0.9% ± 0.7. Conclusion: Minimal differences were noted in the delivery of the 10 patient plans. Over a period that included acceptance testing, commissioning, and clinical deliveries, the MR-IGRT system remained consistent in radiation delivery.

60 APPLIED LIFE SCIENCES↗