Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Global field reconstruction from sparse sensors with Veronoi tessellation-assisted deep learning

Achieving accurate and robust global situational awareness of a complex time-evolving field from a limited number of sensors has been a longstanding challenge. This reconstruction problem is especially difficult when sensors are sparsely positioned in a seemingly random or unorganized manner, which is often encountered in a range of scientific and engineering problems. Moreover, these sensors can be in motion and can become online or offline over time. The key leverage in addressing this scientific issue is the wealth of data accumulated from the sensors. As a solution to this problem, we propose a data-driven spatial field recovery technique founded on a structured grid-based deep-learning approach for arbitrary positioned sensors of any numbers. It should be noted that the naïve use of machine learning becomes prohibitively expensive for global field reconstruction and is furthermore not adaptable to an arbitrary number of sensors. In the present work, we consider the use of Voronoi tessellation to obtain a structured-grid representation from sensor locations enabling the computationally tractable use of convolutional neural networks. One of the central features of the present method is its compatibility with deep-learning based super-resolution reconstruction techniques for structured sensor data that are established for image processing. The proposed reconstruction technique is demonstrated for unsteady wake flow, geophysical data, and three-dimensional turbulence. The current framework is able to handle an arbitrary number of moving sensors, and thereby overcomes a major limitation with existing reconstruction methods. The presented technique opens a new pathway towards the practical use of neural networks for real-time global field estimation.

Fukami, Kai↗

Super-resolution with the Help of Active Camera

In a digital optical imaging system, image resolution is constrained by several factors, including focus plane array pitch and optics. Super-resolution approaches aim at overcoming some of these limits by incorporating additional information of the object and/or combining several pictures of the same object, taken with sub-pixel displacements between each other. As shown by some authors, the obtainable zoom factor using the second approach has an upper limit, determined by the signal-to-noise ratio of the image taken. Moreover, as discussed later in this paper, lines at some pitch are indistinguishable, further lowering this limit. Here, an approach to overcome this using active camera and employing images of different relative scales is introduced. The choice of these scales is commented. The results from two experiments, using simulated and real set-up are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an x-ray prism for analyzer based imaging systems

Analyzer crystal based imaging techniques such as diffraction enhanced imaging (DEI) and multiple imaging radiography (MIR) utilize the Bragg peak of perfect crystal diffraction to convert angular changes into intensity changes. These x-ray techniques extend the capability of conventional radiography, which derives image contrast from absorption, by providing large intensity changes for small angle changes introduced from the x-ray beam traversing the sample. Objects that have very little absorption contrast may have considerable refraction and ultrasmall angle x-ray scattering contrast improving visualization and extending the utility of x-ray imaging. To improve on the current DEI technique an x-ray prism (XRP) was designed and included in the imaging system. The XRP allows the analyzer crystal to be aligned anywhere on the rocking curve without physically moving the analyzer from the Bragg angle. By using the XRP to set the rocking curve alignment rather than moving the analyzer crystal physically the needed angle sensitivity is changed from submicroradians for direct mechanical movement of the analyzer crystal to tens of milliradians for movement of the XRP angle. However, this improvement in angle positioning comes at the cost of absorption loss in the XRP and depends on the x-ray energy. In addition to using an XRP for crystal alignment it has the potential for scanning quickly through the entire rocking curve. This has the benefit of collecting all the required data for image reconstruction in a single measurement thereby removing some problems with motion artifacts which remain a concern in current DEI/MIR systems especially for living animals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heuristic optimization in penumbral image for high resolution reconstructed image

Penumbral imaging is a technique which uses the fact that spatial information can be recovered from the shadow or penumbra that an unknown source casts through a simple large circular aperture. The size of the penumbral image on the detector can be mathematically determined as its aperture size, object size, and magnification. Conventional reconstruction methods are very sensitive to noise. On the other hand, the heuristic reconstruction method is very tolerant of noise. However, the aperture size influences the accuracy and resolution of the reconstructed image. In this article, we propose the optimization of the aperture size for the neutron penumbral imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical boundary reconstruction of tokamak plasmas for feedback control of plasma position and shape

A new diagnostic is developed to reconstruct the plasma boundary using visible wavelength images. Exploiting the plasma's edge localized and toroidally symmetric emission profile, a new coordinate transform is presented to reconstruct the plasma boundary from a poloidal view image. The plasma boundary reconstruction is implemented in MATLAB and applied to camera images of Mega-Ampere Spherical Tokamak discharges. The optically reconstructed plasma boundaries are compared to magnetic reconstructions from the offline reconstruction code EFIT, showing very good qualitative and quantitative agreement. Average errors are within 2 cm and correlation is high. In the current software implementation, plasma boundary reconstruction from a single image takes 3 ms. The applicability and system requirements of the new optical boundary reconstruction, called OFIT, for use in both feedback control of plasma position and shape and in offline reconstruction tools are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous sample and spatial coherence characterisation using diffractive imaging

We demonstrate an algorithm that reconstructs the complex transmission function of an object from experimental X-ray diffraction data using partially coherent 1.4 keV X-rays that does not require a priori input of the coherence function. The quality of the reconstruction is significantly better than that obtained by assuming that the illumination is fully coherent. Our approach can be readily applied to diffraction imaging problems where a model for the spatial coherence can be assumed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration method of tilt and azimuth angles for alignment of TEM tomographic tilt series

This paper describes the calibration method of the tilt and azimuth angles of specimen using a digital protractor and a laser autocollimator for alignment of electron tomography. It also suggests an easy method to check whether the specimen is tilted by 180.0 deg., and whether the azimuth angle is 0.0 deg.; the method involves the use of two images of a rod-shaped specimen collected before and after a 180.0 deg. The method is based on the assumption that these images are symmetric about the tilt axis when the azimuth angle is 0.0 deg. In addition, we used an experiment to demonstrate the effect of the incorrect angles on reconstructed images and simulated the image quality against distance away from tilt axis.

43 PARTICLE ACCELERATORS↗

Simulated Performance of Algorithms for the Localization of Radioactive Sources from a Position Sensitive Radiation Detecting System (COCAE)

Simulation studies are presented regarding the performance of algorithms that localize point-like radioactive sources detected by a position sensitive portable radiation instrument (COCAE). The source direction is estimated by using the List Mode Maximum Likelihood Expectation Maximization (LM-ML-EM) imaging algorithm. Furthermore, the source-to-detector distance is evaluated by three different algorithms based on the photo-peak count information of each detecting layer, the quality of the reconstructed source image, and the triangulation method. These algorithms have been tested on a large number of simulated photons over a wide energy range (from 200 keV to 2 MeV) emitted by point-like radioactive sources located at different orientations and source-to-detector distances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of synchrotron radiation computed microtomography for quantification of bone microstructure in human and rat bones

This work aims to evaluate histomorphometric quantification by synchrotron radiation computed microto-mography in bones of human and rat specimens. Bones specimens are classified as normal and pathological (for human samples) and irradiated and non-irradiated samples (for rat ones). Human bones are specimens which were affected by some injury, or not. Rat bones are specimens which were irradiated, simulating radiotherapy procedures, or not. Images were obtained on SYRMEP beamline at the Elettra Synchrotron Laboratory in Trieste, Italy. The system generated 14 {mu}m tomographic images. The quantification of bone structures were performed directly by the 3D rendered images using a home-made software. Resolution yielded was excellent what facilitate quantification of bone microstructures.

60 APPLIED LIFE SCIENCES↗

The evolution of solid density within a thermal explosion II. Dynamic proton radiography of cracking and solid consumption by burning

We report proton transmission images obtained subsequent to the laser assisted thermal ignition of a sample of PBX 9501 (a plastic bonded formulation of the explosive nitramine octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX)). We describe the laser assisted thermal ignition technique as a means to synchronize a non-linear thermal ignition event while preserving the subsequent post-ignition behavior. We have obtained dynamic proton transmission images at two spatial magnifications and viewed both the radial and transverse axis of a solid cylindrical sample encased in aluminum. Images have been obtained with 3 to 15 {mu}s temporal resolution and approximately 100 {mu}m spatial resolution at the higher magnification. We observe case expansion from very early in the experiment, until case fragmentation. We observe spatially anisotropic features in the transmission which we attribute to cracking in the solid explosive, in agreement with previous measurements conducted on two dimensional samples with optical viewing. Digital analysis of the images also reveals spatially isotropic features which we attribute to the evolution of the loss of density by burning subsequent to thermal ignition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data-driven imaging in anisotropic media

Anisotropic materials are being used increasingly in high performance industrial applications, particularly in the aeronautical and nuclear industries. Some important examples of these materials are composites, single-crystal and heavy-grained metals. Ultrasonic array imaging in these materials requires exact knowledge of the anisotropic material properties. Without this information, the images can be adversely affected, causing a reduction in defect detection and characterization performance. The imaging operation can be formulated in two consecutive and reciprocal focusing steps, i.e., focusing the sources and then focusing the receivers. Applying just one of these focusing steps yields an interesting intermediate domain. The resulting common focus point gather (CFP-gather) can be interpreted to determine the propagation operator. After focusing the sources, the observed travel-time in the CFP-gather describes the propagation from the focus point to the receivers. If the correct propagation operator is used, the measured travel-times should be the same as the time-reversed focusing operator due to reciprocity. This makes it possible to iteratively update the focusing operator using the data only and allows the material to be imaged without explicit knowledge of the anisotropic material parameters. Furthermore, the determined propagation operator can also be used to invert for the anisotropic medium parameters. This paper details the proposed technique and demonstrates its use on simulated array data from a specimen of Inconel single-crystal alloy commonly used in the aeronautical and nuclear industries.

36 MATERIALS SCIENCE↗

Enhanced x-ray imaging for a thin film cochlear implant with metal artefacts using phase retrieval tomography

Phase retrieval tomography has been successfully used to enhance imaging in systems that exhibit poor absorption contrast. However, when highly absorbing regions are present in a sample, so-called metal artefacts can appear in the tomographic reconstruction. We demonstrate that straightforward approaches for metal artefact reconstruction, developed in absorption contrast tomography, can be applied when using phase retrieval. Using a prototype thin film cochlear implant that has high and low absorption components made from iridium (or platinum) and plastic, respectively, we show that segmentation of the various components is possible and hence measurement of the electrode geometry and relative location to other regions of interest can be achieved.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robust inverse scattering full waveform seismic tomography for imaging complex structure

Seismic tomography becomes important tool recently for imaging complex subsurface. It is well known that imaging complex rich fault zone is difficult. In this paper, The application of time domain inverse scattering wave tomography to image the complex fault zone would be shown on this paper, especially an efficient time domain inverse scattering tomography and their run in cluster parallel computer which has been developed. This algorithm is purely based on scattering theory through solving Lippmann Schwienger integral by using Born's approximation. In this paper, it is shown the robustness of this algorithm especially in avoiding the inversion trapped in local minimum to reach global minimum. A large data are solved by windowing and blocking technique of memory as well as computation. Parameter of windowing computation is based on shot gather's aperture. This windowing technique reduces memory as well as computation significantly. This parallel algorithm is done by means cluster system of 120 processors from 20 nodes of AMD Phenom II. Benchmarking of this algorithm is done by means Marmoussi model which can be representative of complex rich fault area. It is shown that the proposed method can image clearly the rich fault and complex zone in Marmoussi model even though the initial model is quite far from the true model. Therefore, this method can be as one of solution to image the very complex mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new aperture for neutron and x-ray imaging of inertial confinement fusion experiments

Recent neutron imaging of experiments at the National Ignition Facility has provided useful information about the hotspot shape and cold-fuel distribution and has also given insight into avenues for improvement. Neutron image reconstruction depends on accurate pointing information because the point-spread function of the neutron aperture is not shift invariant. Current pointing techniques are limited in their accuracy and rely upon detailed information about the as-built structure of the array, which is difficult to determine. We present a technique for extracting high-precision pointing information from both neutron and x-ray images, and a new aperture design with features to facilitate this technique, and allow future co-registration of neutron and x-ray images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavelets in medical imaging

The aim of this study is to provide emerging applications of wavelet methods to medical signals and images, such as electrocardiogram, electroencephalogram, functional magnetic resonance imaging, computer tomography, X-ray and mammography. Interpretation of these signals and images are quite important. Nowadays wavelet methods have a significant impact on the science of medical imaging and the diagnosis of disease and screening protocols. Based on our initial investigations, future directions include neurosurgical planning and improved assessment of risk for individual patients, improved assessment and strategies for the treatment of chronic pain, improved seizure localization, and improved understanding of the physiology of neurological disorders. We look ahead to these and other emerging applications as the benefits of this technology become incorporated into current and future patient care. In this chapter by applying Fourier transform and wavelet transform, analysis and denoising of one of the important biomedical signals like EEG is carried out. The presence of rhythm, template matching, and correlation is discussed by various method. Energy of EEG signal is used to detect seizure in an epileptic patient. We have also performed denoising of EEG signals by SWT.

60 APPLIED LIFE SCIENCES↗

Milestones and basic principles of grating-based x-ray and neutron phase-contrast imaging

This is a review of the most important milestones in the last ten years of development in the field of grating-based x-ray and neutron imaging. It provides a description of the basic imaging principles of grating-based phase-contrast and dark-field radiography and present some exemplary multimodal radiography results obtained with x-rays and neutrons. Furthermore, it reviews the theory of grating-based quantitative transmission, phase-contrast, and dark-field scattering computed tomography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-shot X-ray phase-contrast imaging using two-dimensional gratings

We developed a two-dimensional gratings-based X-ray interferometer that requires only a single exposure for clinical radiography. The interferometer consisted of a checkerboard phase grating for {pi} phase modulation and a latticed amplitude grating. Using a synchrotron radiation source, the phase grating modulates the X-rays and generates a self-image, transformed to a moire fringe by the amplitude grating. To allow use of a conventional X-ray tube, the latticed source grating was installed downstream from the X-ray tube. Differential phase-contrast and scattering images in two orthogonal directions were obtained by Fourier analysis of the single moire fringe image and an absorption image. Results show that characteristic features of soft tissue in two orthogonal directions were clearly shown in the differential phase-contrast images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray phase imaging-From static observation to dynamic observation-

We are attempting to expand the technology of X-ray grating phase imaging/tomography to enable dynamic observation. X-ray phase imaging has been performed mainly for static cases, and this challenge is significant since properties of materials (and hopefully their functions) would be understood by observing their dynamics in addition to their structure, which is an inherent advantage of X-ray imaging. Our recent activities in combination with white synchrotron radiation for this purpose are described. Taking advantage of the fact that an X-ray grating interferometer functions with X-rays of a broad energy bandwidth (and therefore high flux), movies of differential phase images and visibility images are obtained with a time resolution of a millisecond. The time resolution of X-ray phase tomography can therefore be a second. This study is performed as a part of a project to explore X-ray grating interferometry, and our other current activities are also briefly outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗