Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging & optical processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

RXTE Observations of Selected Blazars

The work completed includes the analysis of observations obtained during Cycles 4 and 5 of the Rossi X-ray Timing Explorer (RXTE). The project is part of a longer-term, continuing program to study the X-ray emission process in blazars in cooperation with Dr. Ian McHardy (U. of Southampton, UK). The goals of the program are to study the X-ray emission mechanism in blazars and the relation of the X-ray emission to changes in the relativistic jet. The program includes contemporaneous brightness and linear polarization monitoring at radio and optical wavelengths, total and polarized intensity imaging at 43 GHz with a resolution of 0.1 milliarcseconds with the Very Long Baseline Array (VLBA), and well-sampled X-ray light curves obtained from a series of approved RXTE programs.

Aller, Margo F.↗

Frequency-Dependent Time Lags in Three Blazars

The work completed includes the analysis of observations obtained during Cycle 6 of the Rossi X-ray Timing Explorer (RXTE). The project is part of a longer-term, continuing program to study the X-ray emission process in blazars in collaboration with Dr. Ian McHardy (U. of Southampton, UK). The goals of the program are to study the X-ray emission mechanism in blazars and the relation of the X-ray emission to changes in the relativistic jet. The program includes contemporaneous brightness and linear polarization monitoring at radio and optical wavelengths, total and polarized intensity imaging at 43 GHz with a resolution of 0.1 milliarcseconds with the VLBA, and well-sampled X-ray light curves obtained from a series of approved RXTE programs. During RXTE cycle 6, the project was awarded RXTE time to monitor three quasars: PKS 1510-089 two times per week, and 3C 273 and 3C 279 three times per week each. The X-ray data, including those from earlier cycles, were compared with radio measurements obtained 2-3 times per week in the centimeter-wave band with the Michigan radio telescope, monthly imaging observations with the VLBA at 43 GHz, and optical observations obtained at several telescopes around the world. Since it is the long-term X-ray light curve that is of greatest value, this report includes discussion of all the data collected through August 2003 rather than just the Cycle 6 data.

Marscher, Alan P.↗

Phase Retrieval System for Assessing Diamond Turning and Optical Surface Defects

An optical design is presented for a measurement system used to assess the impact of surface errors originating from diamond turning artifacts. Diamond turning artifacts are common by-products of optical surface shaping using the diamond turning process (a diamond-tipped cutting tool used in a lathe configuration). Assessing and evaluating the errors imparted by diamond turning (including other surface errors attributed to optical manufacturing techniques) can be problematic and generally requires the use of an optical interferometer. Commercial interferometers can be expensive when compared to the simple optical setup developed here, which is used in combination with an image-based sensing technique (phase retrieval). Phase retrieval is a general term used in optics to describe the estimation of optical imperfections or aberrations. This turnkey system uses only image-based data and has minimal hardware requirements. The system is straightforward to set up, easy to align, and can provide nanometer accuracy on the measurement of optical surface defects.

Dean, Bruce↗

Optical Distortion Evaluation in Large Area Windows using Interferometry

It is important that imagery seen through large area windows, such as those used on space vehicles, not be substantially distorted. Many approaches are described in the literature for measuring the distortion of an optical window, but most suffer from either poor resolution or processing difficulties. In this paper a new definition of distortion is presented, allowing accurate measurement using an optical interferometer. This new definition is shown to be equivalent to the definitions provided by the military and the standards organizations. In order to determine the advantages and disadvantages of this new approach the distortion of an acrylic window is measured using three different methods; image comparison, Moiré interferometry, and phase-shifting interferometry.

Interferometer↗

A Comparison of Three Methods for Measuring Distortion in Optical Windows

It's important that imagery seen through large-area windows, such as those used on space vehicles, not be substantially distorted. Many approaches are described in the literature for measuring the distortion of an optical window, but most suffer from either poor resolution or processing difficulties. In this paper a new definition of distortion is presented, allowing accurate measurement using an optical interferometer. This new definition is shown to be equivalent to the definitions provided by the military and the standards organizations. In order to determine the advantages and disadvantages of this new approach, the distortion of an acrylic window is measured using three different methods: image comparison, moiré interferometry, and phase-shifting interferometry.

Interferometry↗

Advanced Bayesian Method for Planetary Surface Navigation

Autonomous Exploration, Inc., has developed an advanced Bayesian statistical inference method that leverages current computing technology to produce a highly accurate surface navigation system. The method combines dense stereo vision and high-speed optical flow to implement visual odometry (VO) to track faster rover movements. The Bayesian VO technique improves performance by using all image information rather than corner features only. The method determines what can be learned from each image pixel and weighs the information accordingly. This capability improves performance in shadowed areas that yield only low-contrast images. The error characteristics of the visual processing are complementary to those of a low-cost inertial measurement unit (IMU), so the combination of the two capabilities provides highly accurate navigation. The method increases NASA mission productivity by enabling faster rover speed and accuracy. On Earth, the technology will permit operation of robots and autonomous vehicles in areas where the Global Positioning System (GPS) is degraded or unavailable.

Center, Julian↗

Multiple detector focal plane array ultraviolet spectrometer for the AMPS laboratory

The possibility of meeting the requirements of the amps spectroscopic instrumentation by using a multi-element focal plane detector array in a conventional spectrograph mount was examined. The requirements of the detector array were determined from the optical design of the spectrometer which in turn depends on the desired level of resolution and sensitivity required. The choice of available detectors and their associated electronics and controls was surveyed, bearing in mind that the data collection rate from this system is so great that on-board processing and reduction of data are absolutely essential. Finally, parallel developments in instrumentation for imaging in astronomy were examined, both in the ultraviolet (for the Large Space Telescope as well as other rocket and satellite programs) and in the visible, to determine what progress in that area can have direct bearing on atmospheric spectroscopy.

Feldman, P. D.↗

Application of Hilbert-Huang Transform for Improved Defect Detection in Terahertz NDE of Shuttle Tiles

Terahertz NDE is being examined as a method to inspect the adhesive bond-line of Space Shuttle tiles for defects. Terahertz signals are generated and detected, using optical excitation of biased semiconductors with femtosecond laser pulses. Shuttle tile samples were manufactured with defects that included repair regions unbond regions, and other conditions that occur in Shuttle structures. These samples were inspected with a commercial terahertz NDE system that scanned a tile and generated a data set of RF signals. The signals were post processed to generate C-scan type images that are typically seen in ultrasonic NDE. To improve defect visualization the Hilbert-Huang Transform, a transform that decomposes a signal into oscillating components called intrinsic mode functions, was applied to test signals identified as being in and out of the defect regions and then on a complete data set. As expected with this transform, the results showed that the decomposed low-order modes correspond to signal noise while the high-order modes correspond to low frequency oscillations in the signal and mid-order modes correspond to local signal oscillations. The local oscillations compare well with various reflection interfaces and the defect locations in the original signal.

Anastasi, Robert F.↗

Directional emittance surface measurement system and process

Apparatus and process for measuring the variation of directional emittance of surfaces at various temperatures using a radiometric infrared imaging system. A surface test sample is coated onto a copper target plate provided with selective heating within the desired incremental temperature range to be tested and positioned onto a precision rotator to present selected inclination angles of the sample relative to the fixed positioned and optically aligned infrared imager. A thermal insulator holder maintains the target plate on the precision rotator. A screen display of the temperature obtained by the infrared imager, and inclination readings are provided with computer calculations of directional emittance being performed automatically according to equations provided to convert selected incremental target temperatures and inclination angles to relative target directional emittance values. The directional emittance of flat black lacquer and an epoxy resin measurements obtained are in agreement with the predictions of the electromagnetic theory and with directional emittance data inferred from directional reflectance measurements made on a spectrophotometer.

Puram, Chith K.↗

Wavefront Sensing With Switched Lenses for Defocus Diversity

In an alternative hardware design for an apparatus used in image-based wavefront sensing, defocus diversity is introduced by means of fixed lenses that are mounted in a filter wheel (see figure) so that they can be alternately switched into a position in front of the focal plane of an electronic camera recording the image formed by the optical system under test. [The terms image-based, wavefront sensing, and defocus diversity are defined in the first of the three immediately preceding articles, Broadband Phase Retrieval for Image-Based Wavefront Sensing (GSC-14899-1).] Each lens in the filter wheel is designed so that the optical effect of placing it at the assigned position is equivalent to the optical effect of translating the camera a specified defocus distance along the optical axis. Heretofore, defocus diversity has been obtained by translating the imaging camera along the optical axis to various defocus positions. Because data must be taken at multiple, accurately measured defocus positions, it is necessary to mount the camera on a precise translation stage that must be calibrated for each defocus position and/or to use an optical encoder for measurement and feedback control of the defocus positions. Additional latency is introduced into the wavefront sensing process as the camera is translated to the various defocus positions. Moreover, if the optical system under test has a large focal length, the required defocus values are large, making it necessary to use a correspondingly bulky translation stage. By eliminating the need for translation of the camera, the alternative design simplifies and accelerates the wavefront-sensing process. This design is cost-effective in that the filterwheel/lens mechanism can be built from commercial catalog components. After initial calibration of the defocus value of each lens, a selected defocus value is introduced by simply rotating the filter wheel to place the corresponding lens in front of the camera. The rotation of the wheel can be automated by use of a motor drive, and further calibration is not necessary. Because a camera-translation stage is no longer needed, the size of the overall apparatus can be correspondingly reduced.

Dean, Bruce H.↗

Pull-off Behavior of Stitched Composite T-Joints

T-joints are key structural elements that connect opposing surfaces, thereby providing the load path between flat or curved panels (i.e., upper and lower wing skins) and transverse components (i.e., stiffeners). Due to the low interlaminar strength of polymer matrix composites and their geometrical discontinuities, these joints are vulnerable to pull-off loads. To address these issues, through-thickness reinforcements can be employed to enhance the interlaminar capability of these type of joints. In this study, T-joints were manufactured using through-thickness stitching in dry carbon preforms and cured using the vacuum-assisted resin transfer molding (VARTM) process. Stitched and unstitched T-joints were tested under pull-off loading conditions, and surface strain fields were obtained using a 3D digital image correlation system. The ultimate load, displacement, and absorbed energy of the stitched T-joints were greater than their unstitched counterparts by approximately 16%, 34%, and 58%, respectively. Failure mechanisms were identified by examining fracture surfaces using optical microscopy. Results demonstrate that through-thickness stitching significantly improves the damage tolerance of T-joints, which highlights the effectiveness of stitching to enhance the structural integrity of large aerospace components.

VARTM↗

Telescope technology for the Far Ultraviolet Spectroscopic Explorer (FUSE)

Preliminary engineering studies are in progress to define a telescope for FUSE. General science objectives include high resolution spectroscopy in the 900-1200 A spectral region, low or moderate resolution spectroscopy in the 100-900 A range, and long slit imaging over a 1-arcmin field at a spatial resolution of 1 arcsec. Telescope design studies indicate that a 1-m-diameter Wolter-Schwarzschild type II glancing-incidence telescope with an effective collecting area of 3000 sq cm is required to meet the primary science objectives. A baseline optical design has been completed, and initial alignment sensitivities derived to begin the process of error allocation for the entire system.

Osantowski, J. F.↗

A new approach for performing contamination control bakeouts in JPL thermal vacuum test chambers

Contamination control requirements for the Wide Field/Planetary Camera II (WF/PC II) are necessarily stringent to protect against post-launch contamination of the sensitive optical surfaces, particularly the cold charge coupled device (CCD) imaging surfaces. Typically, thermal vacuum test chambers have employed a liquid nitrogen (LN2) cold trap to collect outgassed contaminants. This approach has the disadvantage of risking recontamination of the test article from shroud offgassing during post-test warmup of the chamber or from any shroud warming of even a few degrees during the bakeout process. By using an enclave, essentially a chamber within a chamber, configured concentrically and internally within an LN2 shroud, a method was developed, based on a design concept by Taylor, for preventing recontamination of test articles during bakeouts and subsequent post-test warmup of the vacuum chamber. Enclaves for testing WF/PC II components were designed and fabricated, then installed in three of JPL's Environmental Test Lab chambers. The design concepts, operating procedures, and test results of this development are discussed.

Johnson, Kenneth R.↗

HST photometry of the trapezium cluster

We have obtained images of 11 fields in the Trapezium cluster with the Planetary Camera (PC) of the Hubble Space Telescope (HST) in order to extend Herbig & Terndrup's (1986) study of this prototype, dense embedded cluster to fainter magnitudes than is possible from the ground. Using these images, we have identified 319 stars within an area of approximately 12 sq arc min corresponding roughly to a volume of approximately 0.065 cu pc assuming the cluster is approximately spherically symmetric. Our completeness limits for star identification in V-band and I-band images are V approximately = 20 and I(sub c) approximately = 19 respectively, corresponding to a mass limit of approximately 0.15 solar mass if the faintest stars have the same average A(sub v) as that estimated for the brighter stars in the cluster. We have compared the V versus V-I color-magnitude diagram derived from the HST photometry to new theoretical isochrones. Star formation in the Trapezium appears to be remarkably coeval, with greater than or = 80% of the stars having inferred ages less than 1 Myr. Over the somewhat limited mass range of the observations, there is no evidence for 'bimodal' star formation-the high- and low-mass stars appear to have the same ages. The sharp cores of the HST images and the small angular size of the PC pixels has allowed us to identify 35 new visual binaries in the cluster with separations from approximately 0.06 arc sec (approximately 26 AU) to approximately 1.0 arc sec (approximately 440 AU). For the range of binary separations that we are sensitive to, the observed binary frequency for the Trapezium is essentially identical to that estimated for field low-mass stars by Duquennoy & Mayor (1991). The most straightfoward inference from this result is that binaries in this separation are unlikely to be formed by a tidal capture process. We have also identified three stars which have associated compact nebulosity visible in the HST images. One of these star + nebulosity cases was previously identified by O'Dell, Wen, & Hu (1993)-these objects appear to form a class of objects whose circumstellar matter is being 'lit up', most likely by Theta(sup 1) Ori C, enabling the gas to be observable at both optical and radio wavelengths (Felli et al. 1993a, b). We provide a brief summary of the optical properties of the other radio sources which appear in our PC images.

Prosser, Charles F.↗

Offering an Array of Improvements

Sensors Unlimited, Inc., with SBIR funding from NASA's Langley Research Center, Goddard Space Flight Center, Marshall Space Flight Center, and the Jet Propulsion Laboratory, developed a monolithic focal plane array for near-infrared imaging. The company developed one- (1- D) and two-dimensional (2-D) imaging arrays consisting of a highly reliable InGaAs p-I-n diode as a photodetector for monitoring a variety of applications, including single element device applications in receivers. The InGaAs 1-D and 2-D arrays have many applications. For example, they monitor the performance of dense wavelength division multiplexing (DWDM) systems- the process of packaging many channels into a single fiber-optic cable. Sensors Unlimited commercially offers its LXTM and LYTM Series InGaAs linear arrays for reliable DWDM performance monitoring. The LX and LY arrays enable instrument module designs with no moving parts, which provides for superior uniformity, and fast, linear outputs that remain stable over a wide temperature range. Innovative technologies derived from the monolithic focal plane array have enabled telecommunication companies to optimize existing bandwidth in their fiber-optic networks in order to support a high volume of network traffic. At the same time, the technologies obtained from the array have the potential for reducing costs, while increasing performance from Sensors Unlimited's current product lines.

Source record↗

The Fractal-based Analysis of the Regulation of Vascular Remodeling in the Quail Chorioallantoic Membrane

Critical to the advancement of space exploration is the safety and well being of astronauts while in space. This study focuses on the second highest of NASA-defined risk categories for human space exploration, cardiovascular alterations. Current research of this problem is being tackled by investigating angiogenesis through vascular remodeling. Angiogenesis is the growth and formation of new blood vessels. Angiogenesis is an important part of maintaining normal development and bodily functions. The loss of control of this process, either insufficient or excessive vascular growth, is considered a common denominator in many diseases, such as cancer, diabetes, and coronary artery disease. Objectives are presently being met by observing the effects of various regulators, like thrombospondin 1 (TSP-1) and a novel vessel tortuosity factor (TF), through the use of the chorioallantoic membrane (CAM) of Japanese quail embryos, which enables the direct optical imaging of 2-dimensional vascular branching trees. Research within the CAM is being performed to deduce numerous methods of regulating vessel growth. This project centers on the ability of a novel vessel regulator to affect angiogenesis. For example, it is hypothesized that the TSP-1 will inhibit the growth of CAM vasculature. Fractal/VESGEN-based techniques and PTV analysis are the methodologies used to investigate vascular differentiation. This tactic is used to quantify results and measure the growth patterns and morphology of blood vessels. The regulatory mechanisms posed by this vessel regulator can be deduced by alterations found within the vasculature patterns of quail embryos.

Smith, Genee S.↗

Contamination Examples and Lessons from Low Earth Orbit Experiments and Operational Hardware

Flight experiments flown on the Space Shuttle, the International Space Station, Mir, Skylab, and free flyers such as the Long Duration Exposure Facility, the European Retrievable Carrier, and the EFFU, provide multiple opportunities for the investigation of molecular contamination effects. Retrieved hardware from the Solar Maximum Mission satellite, Mir, and the Hubble Space Telescope has also provided the means gaining insight into contamination processes. Images from the above mentioned hardware show contamination effects due to materials processing, hardware storage, pre-flight cleaning, as well as on-orbit events such as outgassing, mechanical failure of hardware in close proximity, impacts from man-made debris, and changes due to natural environment factors.. Contamination effects include significant changes to thermal and electrical properties of thermal control surfaces, optics, and power systems. Data from several flights has been used to develop a rudimentary estimate of asymptotic values for absorptance changes due to long-term solar exposure (4000-6000 Equivalent Sun Hours) of silicone-based molecular contamination deposits of varying thickness. Recommendations and suggestions for processing changes and constraints based on the on-orbit observed results will be presented.

Pippin, Gary↗

Method for nanoscale spatial registration of scanning probes with substrates and surfaces

Embodiments in accordance with the present invention relate to methods and apparatuses for aligning a scanning probe used to pattern a substrate, by comparing the position of the probe to a reference location or spot on the substrate. A first light beam is focused on a surface of the substrate as a spatial reference point. A second light beam then illuminates the scanning probe being used for patterning. An optical microscope images both the focused light beam, and a diffraction pattern, shadow, or light backscattered by the illuminated scanning probe tip of a scanning probe microscope (SPM), which is typically the tip of the scanning probe on an atomic force microscope (AFM). Alignment of the scanning probe tip relative to the mark is then determined by visual observation of the microscope image. This alignment process may be repeated to allow for modification or changing of the scanning probe microscope tip.

Wade, Lawrence A.↗