Search NASA⌕ Search

SEARCH · Search NASA

Results for “LASER TARGETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Covalent Drug Binding in Live Cells Monitored by Mid-Infrared Quantum Cascade Laser Spectroscopy: Photoactive Yellow Protein as a Model System

The detection of drug-target interactions in live cells enables analysis of therapeutic compounds in a native cellular environment. Recent advances in spectroscopy and molecular biology have facilitated the development of genetically encoded vibrational probes like nitriles that can sensitively report on molecular interactions. Nitriles are powerful tools for measuring electrostatic environments within condensed media like proteins, but such measurements in live cells have been hindered by low signal-to-noise ratios. In this study, we design a spectrometer based on a double-beam quantum cascade laser (QCL)-based transmission infrared (IR) source with balanced detection that can significantly enhance sensitivity to nitrile vibrational probes embedded in proteins within cells compared to a conventional FTIR spectrometer. Here, using this approach, we detect small-molecule binding in Escherichia coli, with particular focus on the interaction between para-Coumaric acid (pCA) and nitrile-incorporated photoactive yellow protein (PYP). This system effectively serves as a model for investigating covalent drug binding in a cellular environment. Notably, we observe large spectral shifts of up to 15 cm –1 for nitriles embedded in PYP between the unbound and drug-bound states directly within bacteria, in agreement with observations for purified proteins. Such large spectral shifts are ascribed to the changes in the hydrogen-bonding environment around the local environment of nitriles, accurately modeled through high-level molecular dynamics simulations using the AMOEBA force field. Our findings underscore the QCL spectrometer’s ability to enhance sensitivity for monitoring drug–protein interactions, offering new opportunities for advanced methodologies in drug development and biochemical research.

chromophores↗

Modeling the Interaction of Laser-Produced Proton Beams with Matter

A major goal of this project is to significantly increase our understanding of isochoric heating of matter using laser produced proton beams, and the associated high energy density (HED) and warm dense matter (WDM) regimes generated. This will benefit research fields such as planetary science, fusion energy, plasma physics, and material science. For example, it will enhance our understanding of WDM properties of iron and silica under conditions encountered in planetary interiors and diagnostic components in fusion devices exposed to high fluxes of energetic plasma ions. The project is motivated by recent experiments that irradiated Si targets with proton beams generated by the 20 TW-laser at the SLAC MEC end-station. The HED/WDM states are probed using the 50 fs hard X-rays available in the 3rd harmonic of the LCLS. As part of this project, results from the phase contrast X-ray imaging, which shows the generation of compression waves that produces rear surface spallation, are compared with results from the 3D multi-physics multi- material code, PISALE, that combines Arbitrary Lagrangian-Eulerian (ALE) hydrodynamics with Adaptive Mesh Refinement (AMR). This comparison required modifications to several physics models in the PISALE (Pacific Island Structured-AMR with ALE) code. An important aspect of this project is the continued training of graduate students in HED physics and in conducting complex multiphysics simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Titanium isotope systematics of refractory inclusions: Echoes of molecular cloud heterogeneity

Calcium-aluminum-rich inclusions (CAIs) are highly refractory objects found in different chondrite groups and represent some of the oldest known solids of the Solar System. As such, CAIs provide key information regarding the conditions prevailing in the solar protoplanetary disk as well as subsequent mixing and transport processes. Many studies have investigated CAIs for their isotopic compositions and reported nucleosynthetic isotope anomalies in numerous elements, which are typically explained by the variable incorporation of isotopically highly anomalous presolar phases. However, with the exception of 54 Cr-enriched nanospinels, the exact presolar phases responsible for the isotopic heterogeneities are yet to be identified. To address this issue, we here present in-situ Ti isotopic analyses obtained on a diverse set of CAIs from various CV3 chondrites. In this work, the in-situ measurements were performed by targeting individual mineral phases of 15 CAIs with laser-ablation mass spectrometry and indicate significant inter- and intra-CAI isotopic heterogeneity in the neutron-rich isotope 50 Ti. This is particularly pronounced for primitive fine-grained CAIs, whereas coarse-grained CAIs, which have been subject to melting, exhibit smaller degrees of Ti isotopic heterogeneity. To further investigate this Ti isotopic heterogeneity, we additionally obtained Ti isotopic compositions of sequential acid leachates from two fine-grained and two coarse-grained CAIs derived from CV3 chondrites. In contrast to potential expectations from the first part of the study, we do not observe any significant intra-CAI Ti isotopic heterogeneity between the different leaching steps. The lack of intra-CAI Ti isotopic heterogeneity in the acid leachate samples of this study likely reflects that the leaching procedure is unable to efficiently separate the carriers of isotopically anomalous Ti in CAIs. By comparing the bulk CAI Ti isotope compositions with Ti isotope data for hibonite-rich objects from the literature, we find that the range of Ti isotope compositions recorded by CAIs from various chondrite groups can be accounted for by the averaging of hibonite grains. In turn, the variable Ti isotope compositions of hibonite grains can be explained by the averaging of isotopically diverse presolar grains present in the Sun’s parental molecular cloud. This effect of averaging is statistically supported by the central limit theorem, and the concept has the potential to be useful for other isotopic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

XUV-driven plasma switch for THz: new spatio-temporal overlap tool for XUV–THz pump–probe experiments at FELs

A simple and robust tool for spatio-temporal overlap of THz and XUV pulses in in-vacuum pump–probe experiments is presented. The technique exploits ultrafast changes of the optical properties in semiconductors (i.e. silicon) driven by ultrashort XUV pulses that are probed by THz pulses. This work demonstrates that this tool can be used for a large range of XUV fluences that are significantly lower than when probing by visible and near-infrared pulses. This tool is mainly targeted at emerging X-ray free-electron laser facilities, but can be utilized also at table-top high-harmonics sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a broadband reflective phase retarder to generate circularly polarized light for MTW-OPAL and multipetawatt lasers

Here, our research focuses on designing metallic coatings to create broadband all-reflective phase retarders that generate circularly polarized (CP) light for the MTW-OPAL Laser System while ensuring the desired polarization state on the target. This all-reflective phase retarder can function as a phase retarder when used in an out-of-plane configuration, whereas it acts as a normal mirror set in an in-plane configuration. If the polarization of the beam is not purely s- or p-polarized, however, mirrors will in general introduce retardance, and therefore compensators or polarization-independent mirror pairs are needed to ensure the desired polarization at the target plane.

47 OTHER INSTRUMENTATION↗

Flexure Upgrade System Engineering Project

At the National Ignition Facility (NIF), a system of lasers is used to implode and blow-up targets and create temperatures and pressures unlike any other place on earth. There are many target types that are used on experiments, but they can be broadly put in two categories – room temperature targets and cold targets. All targets can be mounted on any of the three target positioners on NIF, and two of these three target positioners can cryogenically cool the targets in the low Kelvin range for the cold targets. To minimize the ice buildup and infrared light exposure to these cold targets, a shroud surrounds the targets and seals the target from the outer environment. By shrouding the target, air, water, and other molecules have a difficult time reaching the target and some particles get cryo trapped into the shrouds themselves.

42 ENGINEERING↗

Versatile & Intelligent Biodetection via Environmental Sensing (VIBES)

Reactive health monitoring strategies during events like the COVID-19 pandemic highlighted the need for predictive, threat-agnostic diagnostics that can detect both known diseases and novel chemical or biological threats. To address this, we investigated an optical biosensor as a breath volatile organic compound (VOC) analyzer, aiming to emulate biological olfaction. We assembled and validated the device with thin film metal coated substrate-based sensors. We immobilized small biological recognition elements on the substrates and delivered controlled concentrations of target VOCs. The sensor was irradiated with a visible laser and the sensor signal was recorded. We characterized the laser performance and tested 3 recognition elements for 2 VOCs with varying concentrations (1-100 ppm). We also evaluated enhancement of the signal using nanostructures on the metal film in comparison with planar film substrate. We demonstrated detecting ethanol reliably at concentrations as low as ~2 ppm along with preliminary detection of acetone (<100 ppm). We also found several unexpected factors that influence the sensor behavior that should be addressed to further refine the device’s performance. The nanostructures were, as expected, found to amplify the sensor signals. These findings demonstrate the feasibility of the optical bio-sensing modality for breath VOC monitoring at physiologically relevant levels. This positions LLNL to develop a low-cost, scalable, broad-spectrum health monitoring capability aligned with the Early Detection thrust of the Bioresilience Mission Focus Area and attract external funding.

47 OTHER INSTRUMENTATION↗

A high speed pointing system

A laser ranging system for use with the Space Shuttle, and applied to a precise determination of the distance between points arrayed on different tectonic plates, i.e., along the San Andreas fault, spaced at distances of 25, 50, and 100 km, is discussed with attention to the orbiting pointing system. The mount carrying the system contains a single elliptical mirror which directs ten laser firings per second (15-18 firings to each target), and receives the light reflected from the target. The mirror and all moving structural parts are constructed of Be. The axes are equipped with 19-bit shaft angle encoders and brushless torque motors. Care is taken to avoid structural resonances, and to ensure a minimum of servo settling time. A Kalman filter is used with the microprocessor system to interpolate low data rate commands to the higher data rates required by the pointing system.

Winston, G. C.↗

Progress in coherent laser radar

Considerable progress with coherent laser radar has been made over the last few years, most notably perhaps in the available range of high performance devices and components and the confidence with which systems may now be taken into the field for prolonged periods of operation. Some of this increasing maturity was evident at the 3rd Topical Meeting on Coherent Laser Radar: Technology and Applications. Topics included in discussions were: mesoscale wind fields, nocturnal valley drainage and clear air down bursts; airborne Doppler lidar studies and comparison of ground and airborne wind measurement; wind measurement over the sea for comparison with satellite borne microwave sensors; transport of wake vortices at airfield; coherent DIAL methods; a newly assembled Nd-YAG coherent lidar system; backscatter profiles in the atmosphere and wavelength dependence over the 9 to 11 micrometer region; beam propagation; rock and soil classification with an airborne 4-laser system; technology of a global wind profiling system; target calibration; ranging and imaging with coherent pulsed and CW system; signal fluctuations and speckle. Some of these activities are briefly reviewed.

Vaughan, J. M.↗

Time- and position-varying infrared scene simulation

Rapidly changing infrared scenes can be generated as a function of position using thermally produced irradiance. This can be done most conveniently by using a variable dwell-time, variable diameter, and scanning laser beam to deposit a predetermined amount of laser energy, as a function of position, on the target surface. An infrared target simulator has been designed and tested to perform within stringent temperature simulation requirements: heating rate of over 100 K/sec is achieved, and temperature gradients of 200 K/mm can be maintained. Problems with heat transfer between adjacent elements at different temperatures are solved by modeling the thermal layer on the target surface as a low-pass filter, which cuts off all the frequencies above the thermal cutoff frequency. When the system approach is taken to the infrared simulation design, the optical system limited performance results in the best realizable performance. In this case, the thermal layer on the target surface is designed so that the thermal cutoff frequency is above the optical cutoff frequency.

Scholl, Marija S.↗

Space-stabilized beam pointing for a bifocal satellite experiment

The pointing and tracking control concept for an experimental ground-based laser beam relay satellite is described. The satellite receives a low-power laser beam from a ground-based laser, processes it, and reflects it to an instrumented target. The primary control objective is to achieve extremely accurate and stable pointing at the target, including moving targets. This is achieved using an optical/inertial stabilization technique. The paper describes the satellite optical layout and pointing control mechanization.

Redding, David C.↗

High-Power Single-Mode 2.65-micron InGaAsSb/AlInGaAsSb Diode Lasers

Central to the advancement of both satellite and in-situ science are improvements in continuous-wave and pulsed infrared laser systems coupled with integrated miniaturized optics and electronics, allowing for the use of powerful, single-mode light sources aboard both satellite and unmanned aerial vehicle platforms. There is a technological gap in supplying adequate laser sources to address the mid-infrared spectral window for spectroscopic characterization of important atmospheric gases. For high-power applications between 2 to 3 micron, commercial laser technologies are unsuitable because of limitations in output power. For instance, existing InP-based laser systems developed for fiber-based telecommunications cannot be extended to wavelengths longer than 2 micron. For emission wavelengths shorter than 3 micron, intersubband devices, such as infrared quantum cascade lasers, become inefficient due to band-offset limitations. To date, successfully demonstrated singlemode GaSb-based laser diodes emitting between 2 and 3 micron have employed lossy metal Bragg gratings for distributed- feedback coupling, which limits output power due to optical absorption. By optimizing both the quantum well design and the grating fabrication process, index-coupled distributed-feedback 2.65-micron lasers capable of emitting in excess of 25 mW at room temperature have been demonstrated. Specifically, lasers at 3,777/cm (2.65 micron) have been realized to interact with strong absorption lines of HDO and other isotopologues of H2O. With minor modifications of the optical cavity and quantum well designs, lasers can be fabricated at any wavelength within the 2-to-3-micron spectral window with similar performance. At the time of this reporting, lasers with this output power and wavelength accuracy are not commercially available. Monolithic ridge-waveguide GaSb lasers were fabricated that utilize secondorder lateral Bragg gratings to generate single-mode emission from InGaAsSb/ AlInGaAsSb multi-quantum well structures. The device fabrication utilizes etched index-coupled gratings in the top AlGaAsSb cladding of the laser chip along the ridge waveguide, whereas commercial lasers that emit close to this wavelength include loss-coupled metal gratings that limit the output power of the laser. Semiconductor-laser-based spectrometers can be used to replace gas sensors currently used in industry and government. With the availability of high-power laser sources at mid-infrared wavelengths, sensors can target strong fundamental gas absorption lines to maximize instrument sensitivity.

Frez, Clifford F.↗

Chemical Pollution from Combustion of Modern Spacecraft Materials

Fire is one of the most critical contingencies in spacecraft and any closed environment including submarines. Currently, NASA uses particle based technology to detect fires and hand-held combustion product monitors to track the clean-up and restoration of habitable cabin environment after the fire is extinguished. In the future, chemical detection could augment particle detection to eliminate frequent nuisance false alarms triggered by dust. In the interest of understanding combustion from both particulate and chemical generation, NASA Centers have been collaborating on combustion studies at White Sands Test Facility using modern spacecraft materials as fuels, and both old and new technology to measure the chemical and particulate products of combustion. The tests attempted to study smoldering pyrolysis at relatively low temperatures without ignition to flaming conditions. This paper will summarize the results of two 1-week long tests undertaken in 2012, focusing on the chemical products of combustion. The results confirm the key chemical products are carbon monoxide (CO), hydrogen cyanide (HCN), hydrogen fluoride (HF) and hydrogen chloride (HCl), whose concentrations depend on the particular material and test conditions. For example, modern aerospace wire insulation produces significant concentration of HF, which persists in the test chamber longer than anticipated. These compounds are the analytical targets identified for the development of new tunable diode laser based hand-held monitors, to replace the aging electrochemical sensor based devices currently in use on the International Space Station.

Mudgett, Paul D.↗

Diagenetic Features Analyzed by ChemCam/Curiosity at Pahrump Hills, Gale Crater, Mars

Onboard the Mars Science Laboratory (MSL) Curiosity rover, the ChemCam instrument consists of : (1) a Laser-Induced Breakdown Spectrometer (LIBS) for elemental analysis of targets and (2) a Remote Micro Imager (RMI), which provides imaging context for the LIBS. The LIBS/ChemCam performs analysis typically of spot sizes 350-550 micrometers in diameter, up to 7 meters from the rover. Within Gale crater, Curiosity traveled from Bradbury Landing toward the base of Mount Sharp, reaching Pahrump Hills outcrop circa sol 750. This region, as seen from orbit, represents the first exposures of lower Mount Sharp. In this abstract we focus on two types of features present within the Pahrump Hills outcrop: concretion features and light-toned veins.

Nachon, M.↗

Cryogenic Thermal Vacuum Testing with Remote Optical Metrology

Flexure Engineering was awarded an SBIR to research and develop technology needed to build a thermal vacuum chamber made to take laser radar metrology through a window. The XATF test is proof of concept for this, and demonstrated the need for such a chamber. XATF refers to two pieces of critical ground support equipment for NASA's JWST (James Webb Space Telescope) Integrated Science Instrument Module (ISIM), the ISIM Alignment Target Fixture (IATF) and the Master Alignment Target Fixture (MATF). These optical alignment assemblies require characterization while under cryogenic temperature. A thermal vacuum chamber equipped with a shroud cooled with gaseous and liquid nitrogen was used. An inner shroud was cooled with liquid helium to approximately 30K. The XATF assemblies were kinematically mounted and oriented inside the inner shroud such that the optical targets were visible from outside an optical window on one of the chamber ports. Laser radar and theodolite mounted outside the window took measurements of various optical targets. Two cold cycles were completed. A third cycle was aborted. Metrology was successfully taken. There were some problems with the helium system. The cryo pumps were turned off to reduce vibrations during metrology. Many new technologies and testing methods must be developed for JWST and future programs that will require precision measurements. These technologies will be applicable to other cold temperature applications, such as lunar missions and superconductors. Remote metrology technologies can also be applicable to testing in harsh environments. Facilities with remote metrology capability will be valuable.

Boyd, Guinevere↗

Plasma mirror focal spot quality for glass and aluminum mirrors for laser pulses up to 20 ps

High-intensity short-pulse lasers are being pushed further as applications continue to demand higher laser intensities. Uses such as radiography and laser-driven particle acceleration require these higher intensities to produce the necessary x-ray and particle fluxes. Achieving these intensities, however, is limited by the damage threshold of costly optics and the complexity of target chambers. This is evidenced by the Advanced Radiographic Capability (ARC) short-pulse laser at the National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory, producing four high-energy ≈1 kJ laser pulses at 30 ps pulse duration, being limited to an intensity of 10 18 W/cm 2 by the large focal spot size of ≈100 µm. Due to the setup complexity of NIF, changing the location of the final focusing parabola in order to improve the focal spot size is not an option. Therefore, this leads to the possible use of disposable ellipsoidal plasma mirrors (PMs) placed within the chamber, close to the target in an attempt to refocus the four ARC beams. However, the behavior of PMs at these relatively long pulse durations (tens of picoseconds) is not well characterized. The results from the COMET laser at the Jupiter Laser Facility carried out at 0.5 to 20 ps pulse durations on flat mirrors are presented as a necessary first step towards focusing curved mirrors. The findings show defocusing at longer pulse durations and higher intensities, with less degradation when using aluminum coated mirrors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mega-Gauss Plasma Jet Creation Using a Ring of Laser Beams

Using 20 OMEGA laser beams at the Laboratory for Laser Energetics, University of Rochester, to irradiate a flat plastic target in a hollow ring configuration, we created supersonic cylindrical stable plasma jets with self-generated megagauss magnetic fields extending out to >4 mm. These well-collimated magnetized jets possess a number of distinct and novel properties that will allow us to study the dynamics, physical processes, and scaling properties of astrophysical jets with a dynamic range exceeding those of previous laboratory settings. The dimensionless parameters of these laboratory jets fall in the same regime as those of young stellar object jets. These jets will also provide new versatile laser-based platforms to study magnetized shocks, shear flows, and other plasma processes under controllable conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proteomic Profiling of Intra-Islet Features Reveals Substructure-Specific Protein Signatures

Despite their diminutive size, islets of Langerhans play a large role in maintaining systemic energy balance in the body. New technologies have enabled us to go from studying the whole pancreas, to isolated whole islets, to partial islet sections, and now to islet substructures isolated from within the islet. Using a microfluidic nanodroplet-based proteomics platform coupled with laser capture microdissection (LCM), we present an in-depth investigation of protein profiles specific to regions within the islet. These regions studied include the vascular tissue containing interface boundary, micro-vascular tissue internal to the islet, isolated endocrine cells, islet sections with vasculature intact, and finally acinar tissue from around the islet. Unique protein signatures observed in the inner vasculature potentially indicate increased innervation and intra-islet neuron-like crosstalk compared to external vasculature. We also demonstrate the utility of these data for isolating localized structure-specific drug-target interactions using existing protein/drug binding databases.

59 BASIC BIOLOGICAL SCIENCES↗