Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIMITING VALUES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Cavitation during the protein misfolding cyclic amplification (PMCA) method – The trigger for de novo prion generation?

The protein misfolding cyclic amplification (PMCA) technique has become a widely-adopted method for amplifying minute amounts of the infectious conformer of the prion protein (PrP). PMCA involves repeated cycles of 20 kHz sonication and incubation, during which the infectious conformer seeds the conversion of normally folded protein by a templating interaction. Recently, it has proved possible to create an infectious PrP conformer without the need for an infectious seed, by including RNA and the phospholipid POPG as essential cofactors during PMCA. The mechanism underpinning this de novo prion formation remains unknown. In this study, we first establish by spin trapping methods that cavitation bubbles formed during PMCA provide a radical-rich environment. Using a substrate preparation comparable to that employed in studies of de novo prion formation, we demonstrate by immuno-spin trapping that PrP- and RNA-centered radicals are generated during sonication, in addition to PrP-RNA cross-links. We further show that serial PMCA produces protease-resistant PrP that is oxidatively modified. We suggest a unique confluence of structural (membrane-mimetic hydrophobic/hydrophilic bubble interface) and chemical (ROS) effects underlie the phenomenon of de novo prion formation by PMCA, and that these effects have meaningful biological counterparts of possible relevance to spontaneous prion formation in vivo. - Highlights: • Sonication during PMCA generates free radicals at the surface of cavitation bubbles. • PrP-centered and RNA-centered radicals are formed in addition to PrP-RNA adducts. • De novo prions may result from ROS and structural constraints during cavitation.

60 APPLIED LIFE SCIENCES↗

Sequence conservation of protein binding segments in intrinsically disordered regions

Highlights: • Sequence conservation in protein-binding segments in IDRs is analyzed. • Functionally constraint residues in protein-binding segments in IDRs are conserved. • Evolutionary distance should be considered in the comparison of IDRs. • Cryptic binding regions may influence sequence conservation of IDRs. Intrinsically disordered proteins are proteins with intrinsically disordered regions (IDRs) that do not adopt a globular structure in their free state. IDRs have unique regions having protein-binding segments of which play pivotal roles in many biological processes. The binding sites in IDRs are heterogeneous in terms of their sequence conservation: some are conserved and others are not. We have been running a database of intrinsically disordered proteins, IDEAL, and collecting such binding segments, which are called protean segments (ProSs), within it. In this study, we compared the sequence conservation of ProSs, structural domains (SDs), and IDRs other than ProSs (non-ProSs) and found that i) functionally constrained residues in ProSs tend to be conserved, ii) the distribution of conservation scores of ProSs is similar to those of SDs but not non-ProSs, and iii) ProSs found in human proteins are mostly conserved only in vertebrates. These results indicate that the conservation patterns in ProSs principally follow the general rules found in SDs. However, we need to consider evolutionary distance when comparing IDR sequences because ProSs can readily emerge and disappear over the course of protein evolution. Moreover, many ProSs may remain to be identified, which may account for the heterogeneity of the sequence conservation of IDRs.

60 APPLIED LIFE SCIENCES↗

Rietveld refinement of the structures of 1.0 C-S-H and 1.5 C-S-H

Low-Q region Rietveld analyses were performed on C-S-H synchrotron XRD patterns, using the software MAUD. Two different crystal structures of tobermorite 11 A were used as a starting model: monoclinic ordered Merlino tobermorite, and orthorhombic disordered Hamid tobermorite. Structural modifications were required to adapt the structures to the chemical composition and the different interlayer spacing of the C-S-H samples. Refinement of atomic positions was done by using special constraints called fragments that maintain interatomic distances and orientations within atomic polyhedra. Anisotropic crystallite size refinement showed that C-S-H has a nanocrystalline disordered structure with a preferred direction of elongation of the nanocrystallites in the plane of the Ca interlayer. The quality of the fit showed that the monoclinic structure gives a more adequate representation of C-S-H, whereas the disordered orthorhombic structure can be considered a more realistic model if the lack of long-range order of the silica chain along the c-direction is assumed.

36 MATERIALS SCIENCE↗

Theoretical study of reactions of HO{sub 2} in low-temperature oxidation of benzene

We have generated a set of thermodynamic and kinetic parameters for the reactions involving HO{sub 2} in the very early stages of benzene oxidation at low temperatures using density functional theory (DFT). In particular, we report the rate constants for the reactions of HO{sub 2} with benzene and phenyl. The calculated reaction rate constant for the abstraction of H-C{sub 6}H{sub 5} by HO{sub 2} is found to be in good agreement with the limited experimental values. HO{sub 2} addition to benzene is found to be more important than direct abstraction. We show that the reactions of HO{sub 2} with the phenyl radical generate the propagating radical OH in a highly exoergic reaction. The results presented herein should be useful in modeling the oxidation of aromatic compounds at low temperatures. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Effects of radiation and compression on propagating spherical flames of methane/air mixtures near the lean flammability limit

Large discrepancies between the laminar flame speeds and Markstein lengths measured in experiments and those predicted by simulations for ultra-lean methane/air mixtures bring a great concern for kinetic mechanism validation. In order to quantitatively explain these discrepancies, a computational study is performed for propagating spherical flames of lean methane/air mixtures in different spherical chambers using different radiation models. The emphasis is focused on the effects of radiation and compression. It is found that the spherical flame propagation speed is greatly reduced by the coupling between thermal effect (change of flame temperature or unburned gas temperature) and flow effect (inward flow of burned gas) induced by radiation and/or compression. As a result, for methane/air mixtures near the lean flammability limit, the radiation and compression cause large amounts of under-prediction of the laminar flame speeds and Markstein lengths extracted from propagating spherical flames. Since radiation and compression both exist in the experiments on ultra-lean methane/air mixtures reported in the literature, the measured laminar flame speeds and Markstein lengths are much lower than results from simulation and thus cannot be used for kinetic mechanism validation. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Potential impacts of China's climate policies on energy security

Highlights: • We develop an energy security assessment framework in a 3E-integrated system model. • The potential relations between climate targets and energy security are examined. • Climate policy reduces risks of energy system in terms of main safety metrics. • The impact of emission budgets on energy diversity relies on the time scale options. • Co-benefits of energy security would improve the economics of climate policies. - Abstract: Energy security, as an indispensable constituent of economic security, has long been a top research priority, and the dynamics of energy security become particularly complicated with the involvement of climate change. In this work, we combined a one-sector integrated assessment framework with a series of well-proposed energy security metrics to extensively explore the unidirectional consistency between climate policy and energy security from the national perspective. Implementation of climate policy is generally beneficial for improving energy security. Specifically, climate policy helps to reduce the systematic risk of China's energy system according to the metrics of energy (oil) intensity, energy (oil) expenditures and per capita energy (oil) consumption independent of time scale options. As observed from the perspective of energy diversity, co-benefits arising from climate policy primarily emerge in the first half of this century, and they may gradually decline as emission constraints and the phasing out of fossil fuels are enhanced. Additionally, the macroeconomic costs required to reach China's committed carbon-peaking target might be far lower than the costs required to fulfill the emission budgets under the global 2-degree warming rise threshold. If the co-benefits of energy security are considered, the economics of climate policy is expected to significantly improve.

54 ENVIRONMENTAL SCIENCES↗

Efficient Screening of Bi–Metallic Electrocatalysts for Glycerol Valorization

Glycerol is a byproduct of biodiesel production and, as such, it is of limited economic value. By means of electrooxidation, glycerol can be used as a feedstock for scalable hydrogen production, in addition to conversion to value-added products. The development of novel and efficient catalytic electrode materials for the anodic side of the reaction is a key towards a hydrogen-based energy economy. In the present study, a computational screening protocol combining DFT, scaling relations, and microkinetic modeling allows for a rational selection of novel catalysts that can deliver efficient glycerol electrooxidation, low cost of production, and environmental sustainability. Activity and chemical selectivity towards hydrogen production on pure metal catalysts is discussed in terms of volcano-shaped plots. We find that the selectivity in the glycerol oxidation reaction is influenced by a different energy landscape when in the presence of water and best classified by a comparison of O—H and C—H bond-breaking barriers. In addition, we screened 3570 bi-metallic catalysts in the AB (L1 0 ) and A 3 B (L1 2 ) ordered structures for activity, stability, price, and toxicity. By filtering based on the criteria for toxicity, resistance to oxidation, miscibility, and price, we have identified 5 L1 0 structured catalysts (AgPd, AuPd, PtSb, CuPt, and AgPt) and 20 L1 2 catalysts (Ga 3 Ta, In 3 Ta, Ir 3 W, Ir 3 Mo, Cu 3 Pt, Ir 3 Ta, Ir 3 Re, Pd 3 Bi, Pd 3 Cu, Pd 3 W, Pd 3 Co, Pd 3 Sn, Pd 3 Mo, Pd 3 Ag, Pd 3 Ga, Pd 3 Ta, Au 3 Ru, Pd 3 In, Au 3 Ir, and Pd 3 Au) that are all predicted to show high activity. We also identify an additional 37 L1 0 and 92 L1 2 structured electrocatalysts with an anticipated medium-high activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel geometries for air-cooled condensation of ammonia-water mixtures

An analytical and experimental investigation of air-cooled condensers for small-scale ammonia-water absorption heat pumps is presented. Conventional round-tube corrugated fin design and a novel multi-pass tube array design are considered for a condenser operating at severe ambient conditions within a compact footprint. Segmental heat and mass transfer models are developed to gain a deeper understanding of the characteristics of each design. Predicted heat duties are within 5% of the measured values. The limitations of correlations to predict air-side pressure drop in corrugated fins are identified. The performance of the novel multi-pass tube array condenser was comparable to that of conventional condensers, but is determined to be air-side limited throughout length of the heat exchanger. An improved multi-pass condenser design with fins for increased air-side area is proposed using the insights gained from the modeling and experiments. In closing this design meets the heat duty requirements at severe ambient conditions, while decreasing the size of the heat exchanger by 33%.

42 ENGINEERING↗

Initial Efficacy Results of RTOG 0319: Three-Dimensional Conformal Radiation Therapy (3D-CRT) Confined to the Region of the Lumpectomy Cavity for Stage I/ II Breast Carcinoma

Purpose: This prospective study (Radiation Therapy Oncology Group 0319) examines the use of three-dimensional conformal external beam radiotherapy (3D-CRT) to deliver accelerated partial breast irradiation (APBI). Initial data on efficacy and toxicity are presented. Methods and Materials: Patients with Stage I or II breast cancer with lesions {<=}3 cm, negative margins and with {<=}3 positive nodes were eligible. The 3D-CRT was 38.5 Gy in 3.85 Gy/fraction delivered 2x/day. Ipsilateral breast, ipsilateral nodal, contralateral breast, and distant failure (IBF, INF, CBF, DF) were estimated using the cumulative incidence method. Mastectomy-free, disease-free, and overall survival (MFS, DFS, OS) were recorded. The National Cancer Institute Common Terminology Criteria for Adverse Events, version 3, was used to grade acute and late toxicity. Results: Fifty-eight patients were entered and 52 patients are eligible and evaluable for efficacy. The median age of patients was 61 years with the following characteristics: 46% tumor size <1 cm; 87% invasive ductal histology; 94% American Joint Committee on Cancer Stage I; 65% postmenopausal; 83% no chemotherapy; and 71% with no hormone therapy. Median follow-up is 4.5 years (1.7-4.8). Four-year estimates (95% CI) of efficacy are: IBF 6% (0-12%) [4% within field (0-9%)]; INF 2% (0-6%); CBF 0%; DF 8% (0-15%); MFS 90% (78-96%); DFS 84% (71-92%); and OS 96% (85-99%). Only two (4%) Grade 3 toxicities were observed. Conclusions: Initial efficacy and toxicity using 3D-CRT to deliver APBI appears comparable to other experiences with similar follow-up. However, additional patients, further follow-up, and mature Phase III data are needed to evaluate the extent of application, limitations, and value of this particular form of APBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R{sub 50} was reduced by more than 50%. Lung V{sub 20}, V{sub 10}, and V{sub 5} were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor coverage and critical organ sparing. Given the known challenges in central structure dose constraints in stereotactic body radiation therapy to the lung, 4π planning may increase efficacy and reduce toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 1 Study of Dose Escalation in Hypofractionated Proton Beam Therapy for Non-Small Cell Lung Cancer

Background: Many patients with locally advanced non-small cell lung cancer (NSCLC) cannot undergo concurrent chemotherapy because of comorbidities or poor performance status. Hypofractionated radiation regimens, if tolerable, may provide an option to these patients for effective local control. Methods and Materials: Twenty-five patients were enrolled in a phase 1 dose-escalation trial of proton beam therapy (PBT) from September 2010 through July 2012. Eligible patients had histologically documented lung cancer, thymic tumors, carcinoid tumors, or metastatic thyroid tumors. Concurrent chemotherapy was not allowed, but concurrent treatment with biologic agents was. The dose-escalation schema comprised 15 fractions of 3 Gy(relative biological effectiveness [RBE])/fraction, 3.5 Gy(RBE)/fraction, or 4 Gy(RBE)/fraction. Dose constraints were derived from biologically equivalent doses of standard fractionated treatment. Results: The median follow-up time for patients alive at the time of analysis was 13 months (range, 8-28 months). Fifteen patients received treatment to hilar or mediastinal lymph nodes. Two patients experienced dose-limiting toxicity possibly related to treatment; 1 received 3.5-Gy(RBE) fractions and experienced an in-field tracheoesophageal fistula 9 months after PBT and 1 month after bevacizumab. The other patient received 4-Gy(RBE) fractions and was hospitalized for bacterial pneumonia/radiation pneumonitis 4 months after PBT. Conclusion: Hypofractionated PBT to the thorax delivered over 3 weeks was well tolerated even with significant doses to the lungs and mediastinal structures. Phase 2/3 trials are needed to compare the efficacy of this technique with standard treatment for locally advanced NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose–Volume Relationships Associated With Temporal Lobe Radiation Necrosis After Skull Base Proton Beam Therapy

Purpose: We evaluated patient and treatment parameters correlated with development of temporal lobe radiation necrosis. Methods and Materials: This was a retrospective analysis of a cohort of 66 patients treated for skull base chordoma, chondrosarcoma, adenoid cystic carcinoma, or sinonasal malignancies between 2005 and 2012, who had at least 6 months of clinical and radiographic follow-up. The median radiation dose was 75.6 Gy (relative biological effectiveness [RBE]). Analyzed factors included gender, age, hypertension, diabetes, smoking status, use of chemotherapy, and the absolute dose:volume data for both the right and left temporal lobes, considered separately. A generalized estimating equation (GEE) regression analysis evaluated potential predictors of radiation necrosis, and the median effective concentration (EC50) model estimated dose–volume parameters associated with radiation necrosis. Results: Median follow-up time was 31 months (range 6-96 months) and was 34 months in patients who were alive. The Kaplan-Meier estimate of overall survival at 3 years was 84.9%. The 3-year estimate of any grade temporal lobe radiation necrosis was 12.4%, and for grade 2 or higher radiation necrosis was 5.7%. On multivariate GEE, only dose–volume relationships were associated with the risk of radiation necrosis. In the EC50 model, all dose levels from 10 to 70 Gy (RBE) were highly correlated with radiation necrosis, with a 15% 3-year risk of any-grade temporal lobe radiation necrosis when the absolute volume of a temporal lobe receiving 60 Gy (RBE) (aV60) exceeded 5.5 cm{sup 3}, or aV70 > 1.7 cm{sup 3}. Conclusions: Dose–volume parameters are highly correlated with the risk of developing temporal lobe radiation necrosis. In this study the risk of radiation necrosis increased sharply when the temporal lobe aV60 exceeded 5.5 cm{sup 3} or aV70 > 1.7 cm{sup 3}. Treatment planning goals should include constraints on the volume of temporal lobes receiving higher dose. The EC50 model provides suggested dose–volume temporal lobe constraints for conventionally fractionated high-dose skull base radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nomograms for Prediction of Outcome With or Without Adjuvant Radiation Therapy for Patients With Endometrial Cancer: A Pooled Analysis of PORTEC-1 and PORTEC-2 Trials

Background: Postoperative radiation therapy for stage I endometrial cancer improves locoregional control but is without survival benefit. To facilitate treatment decision support for individual patients, accurate statistical models to predict locoregional relapse (LRR), distant relapse (DR), overall survival (OS), and disease-free survival (DFS) are required. Methods and Materials: Clinical trial data from the randomized Post Operative Radiation Therapy for Endometrial Cancer (PORTEC-1; N=714 patients) and PORTEC-2 (N=427 patients) trials and registered group (grade 3 and deep invasion, n=99) were pooled for analysis (N=1240). For most patients (86%) pathology review data were available; otherwise original pathology data were used. Trial variables which were clinically relevant and eligible according to data constraints were age, stage, given treatment (pelvic external beam radiation therapy (EBRT), vaginal brachytherapy (VBT), or no adjuvant treatment, FIGO histological grade, depth of invasion, and lymph-vascular invasion (LVSI). Multivariate analyses were based on Cox proportional hazards regression model. Predictors were selected based on a backward elimination scheme. Model results were expressed by the c-index (0.5-1.0; random to perfect prediction). Two validation sets (n=244 and 291 patients) were used. Results: Accuracy of the developed models was good, with training accuracies between 0.71 and 0.78. The nomograms validated well for DR (0.73), DFS (0.69), and OS (0.70), but validation was only fair for LRR (0.59). Ranking of variables as to their predictive power showed that age, tumor grade, and LVSI were highly predictive for all outcomes, and given treatment for LRR and DFS. The nomograms were able to significantly distinguish low- from high-probability patients for these outcomes. Conclusions: The nomograms are internally validated and able to accurately predict long-term outcome for endometrial cancer patients with observation, pelvic EBRT, or VBT after surgery. These models facilitate decision support in daily clinical practice and can be used for patient counseling and shared decision making, selecting patients who benefit most from adjuvant treatment, and generating new hypotheses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Toxicity Associated With Stereotactic Body Radiation Therapy to the Central Hepatobiliary Tract

Purpose: To identify dosimetric predictors of hepatobiliary (HB) toxicity associated with stereotactic body radiation therapy (SBRT) for liver tumors. Methods and Materials: We retrospectively reviewed 96 patients treated with SBRT for primary (53%) or metastatic (47%) liver tumors between March 2006 and November 2013. The central HB tract (cHBT) was defined by a 15-mm expansion of the portal vein from the splenic confluence to the first bifurcation of left and right portal veins. Patients were censored for toxicity upon local progression or additional liver-directed therapy. HB toxicities were graded according to Common Terminology Criteria for Adverse Events version 4.0. To compare different SBRT fractionations, doses were converted to biologically effective doses (BED) by using the standard linear quadratic model α/β = 10 (BED10). Results: Median follow-up was 12.7 months after SBRT. Median BED10 was 85.5 Gy (range: 37.5-151.2). The median number of fractions was 5 (range: 1-5), with 51 patients (53.1%) receiving 5 fractions and 29 patients (30.2%) receiving 3 fractions. In total, there were 23 (24.0%) grade 2+ and 18 (18.8%) grade 3+ HB toxicities. Nondosimetric factors predictive of grade 3+ HB toxicity included cholangiocarcinoma (CCA) histology (P<.0001), primary liver tumor (P=.0087), and biliary stent (P<.0001). Dosimetric parameters most predictive of grade 3+ HB toxicity were volume receiving above BED10 of 72 Gy (V{sub BED10}72) ≥ 21 cm{sup 3} (relative risk [RR]: 11.6, P<.0001), V{sub BED10}66 ≥ 24 cm{sup 3} (RR: 10.5, P<.0001), and mean BED10 (Dmean{sub BED10}) cHBT ≥14 Gy (RR: 9.2, P<.0001), with V{sub BED10}72 and V{sub BED10}66 corresponding to V40 and V37.7 for 5 fractions and V33.8 and V32.0 for 3 fractions, respectively. V{sub BED10}72 ≥ 21 cm{sup 3}, V{sub BED10}66 ≥ 24 cm{sup 3}, and Dmean{sub BED10} cHBT ≥14 Gy were consistently predictive of grade 3+ toxicity on multivariate analysis. Conclusions: V{sub BED10}72, V{sub BED10}66, and Dmean{sub BED10} to cHBT are associated with HB toxicity. We suggest V{sub BED10}72 < 21 cm{sup 3} (5-fraction: V40 < 21 cm{sup 3}; 3-fraction: V33.8 < 21 cm{sup 3}), V{sub BED10}66 < 24 cm{sup 3} (5-fraction: V37.7 < 24 cm{sup 3}; 3-fraction: V32 < 24 cm{sup 3}) as potential dose constraints for the cHBT when clinically indicated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Routine Treatment Planning 4-Dimensional and Deep-Inspiration Breath-Hold Computed Tomography Delineation of the Left Anterior Descending Artery in Radiation Therapy

Purpose: To assess the feasibility of radiation therapy treatment planning 4-dimensional computed tomography (4DCT) and deep-inspiration breath-hold (DIBH) CT to accurately contour the left anterior descending artery (LAD), a primary indicator of radiation-induced cardiac toxicity for patients undergoing radiation therapy. Methods and Materials: Ten subjects were prospectively imaged with a cardiac-gated MRI protocol to determine cardiac motion effects, including the displacement of a region of interest comprising the LAD. A series of planar views were obtained and resampled to create a 3-dimensional (3D) volume. A 3D optical flow deformable image registration algorithm determined tissue displacement during the cardiac cycle. The measured motion was then used as a spatial boundary to characterize motion blurring of the radiologist-delineated LAD structure for a cohort of 10 consecutive patients enrolled prospectively on a breast study including 4DCT and DIBH scans. Coronary motion–induced blurring artifacts were quantified by applying an unsharp filter to accentuate the LAD structure despite the presence of motion blurring. The 4DCT maximum inhalation and exhalation respiratory phases were coregistered to determine the LAD displacement during tidal respiration, as visualized in 4DCT. Results: The average 90th percentile heart motion for the region of interest was 0.7 ± 0.1 mm (left–right [LR]), 1.3 ± 0.6 mm (superior–inferior [SI]), and 0.6 ± 0.2 mm (anterior–posterior [AP]) in the cardiac-gated MRI cohort. The average relative increase in the number of voxels comprising the LAD contour was 69.4% ± 4.5% for the DIBH. The LAD volume overestimation had the dosimetric impact of decreasing the reported mean LAD dose by 23% ± 9% on average in the DIBH. During tidal respiration the average relative LAD contour increase was 69.3% ± 5.9% and 67.9% ± 4.6% for inhalation and exhalation respiratory phases, respectively. The average 90th percentile LAD motion was 4.8 ± 1.1 mm (LR), 0.9 ± 0.4 mm (SI), and 1.9 ± 0.6 mm (AP) for the 4DCT cohort, in the absence of cardiac gating. Conclusions: An anisotropic margin of 2.7 mm (LR), 4.1 mm (SI), and 2.4 mm (AP) was quantitatively determined to account for motion blurring and patient setup error while placing minimum constraint on the plan optimization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dependence of Achievable Plan Quality on Treatment Technique and Planning Goal Refinement: A Head-and-Neck Intensity Modulated Radiation Therapy Application

Purpose: To develop a practical workflow for retrospectively analyzing target and normal tissue dose–volume endpoints for various intensity modulated radiation therapy (IMRT) delivery techniques; to develop technique-specific planning goals to improve plan consistency and quality when feasible. Methods and Materials: A total of 165 consecutive head-and-neck patients from our patient registry were selected and retrospectively analyzed. All IMRT plans were generated using the same dose–volume guidelines for TomoTherapy (Tomo, Accuray), TrueBeam (TB, Varian) using fixed-field IMRT (TB-IMRT) or RAPIDARC (TB-RAPIDARC), or Siemens Oncor (Siemens-IMRT, Siemens). A MATLAB-based dose–volume extraction and analysis tool was developed to export dosimetric endpoints for each patient. With a fair stratification of patient cohort, the variation of achieved dosimetric endpoints was analyzed among different treatment techniques. Upon identification of statistically significant variations, technique-specific planning goals were derived from dynamically accumulated institutional data. Results: Retrospective analysis showed that although all techniques yielded comparable target coverage, the doses to the critical structures differed. The maximum cord doses were 34.1 ± 2.6, 42.7 ± 2.1, 43.3 ± 2.0, and 45.1 ± 1.6 Gy for Tomo, TB-IMRT, TB-RAPIDARC, and Siemens-IMRT plans, respectively. Analyses of variance showed significant differences for the maximum cord doses but no significant differences for other selected structures among the investigated IMRT delivery techniques. Subsequently, a refined technique-specific dose–volume guideline for maximum cord dose was derived at a confidence level of 95%. The dosimetric plans that failed the refined technique-specific planning goals were reoptimized according to the refined constraints. We observed better cord sparing with minimal variations for the target coverage and other organ at risk sparing for the Tomo cases, and higher parotid doses for C-arm linear accelerator–based IMRT and RAPIDARC plans. Conclusion: Patient registry–based processes allowed easy and systematic dosimetric assessment of treatment plan quality and consistency. Our analysis revealed the dependence of certain dosimetric endpoints on the treatment techniques. Technique-specific refinement of planning goals may lead to improvement in plan consistency and plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulated Arc Therapy Planning for Primary Prostate Cancer With Selective Intraprostatic Boost Determined by {sup 18}F-Choline PET/CT

Purpose: This study evaluated expected tumor control and normal tissue toxicity for prostate volumetric modulated arc therapy (VMAT) with and without radiation boosts to an intraprostatically dominant lesion (IDL), defined by {sup 18}F-choline positron emission tomography/computed tomography (PET/CT). Methods and Materials: Thirty patients with localized prostate cancer underwent {sup 18}F-choline PET/CT before treatment. Two VMAT plans, plan{sub 79} {sub Gy} and plan{sub 100-105} {sub Gy}, were compared for each patient. The whole-prostate planning target volume (PTV{sub prostate}) prescription was 79 Gy in both plans, but plan{sub 100-105} {sub Gy} added simultaneous boost doses of 100 Gy and 105 Gy to the IDL, defined by 60% and 70% of maximum prostatic uptake on {sup 18}F-choline PET (IDL{sub suv60%} and IDL{sub suv70%}, respectively, with IDL{sub suv70%} nested inside IDL{sub suv60%} to potentially enhance tumor specificity of the maximum point dose). Plan evaluations included histopathological correspondence, isodose distributions, dose-volume histograms, tumor control probability (TCP), and normal tissue complication probability (NTCP). Results: Planning objectives and dose constraints proved feasible in 30 of 30 cases. Prostate sextant histopathology was available for 28 cases, confirming that IDL{sub suv60%} adequately covered all tumor-bearing prostate sextants in 27 cases and provided partial coverage in 1 case. Plan{sub 100-105} {sub Gy} had significantly higher TCP than plan{sub 79} {sub Gy} across all prostate regions for α/β ratios ranging from 1.5 Gy to 10 Gy (P<.001 for each case). There were no significant differences in bladder and femoral head NTCP between plans and slightly lower rectal NTCP (endpoint: grade ≥ 2 late toxicity or rectal bleeding) was found for plan{sub 100-105} {sub Gy}. Conclusions: VMAT can potentially increase the likelihood of tumor control in primary prostate cancer while observing normal tissue tolerances through simultaneous delivery of a steep radiation boost to a {sup 18}F-choline PET-defined IDL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shortening Delivery Times of Intensity Modulated Proton Therapy by Reducing Proton Energy Layers During Treatment Plan Optimization

Purpose: To shorten delivery times of intensity modulated proton therapy by reducing the number of energy layers in the treatment plan. Methods and Materials: We have developed an energy layer reduction method, which was implemented into our in-house-developed multicriteria treatment planning system “Erasmus-iCycle.” The method consisted of 2 components: (1) minimizing the logarithm of the total spot weight per energy layer; and (2) iteratively excluding low-weighted energy layers. The method was benchmarked by comparing a robust “time-efficient plan” (with energy layer reduction) with a robust “standard clinical plan” (without energy layer reduction) for 5 oropharyngeal cases and 5 prostate cases. Both plans of each patient had equal robust plan quality, because the worst-case dose parameters of the standard clinical plan were used as dose constraints for the time-efficient plan. Worst-case robust optimization was performed, accounting for setup errors of 3 mm and range errors of 3% + 1 mm. We evaluated the number of energy layers and the expected delivery time per fraction, assuming 30 seconds per beam direction, 10 ms per spot, and 400 Giga-protons per minute. The energy switching time was varied from 0.1 to 5 seconds. Results: The number of energy layers was on average reduced by 45% (range, 30%-56%) for the oropharyngeal cases and by 28% (range, 25%-32%) for the prostate cases. When assuming 1, 2, or 5 seconds energy switching time, the average delivery time was shortened from 3.9 to 3.0 minutes (25%), 6.0 to 4.2 minutes (32%), or 12.3 to 7.7 minutes (38%) for the oropharyngeal cases, and from 3.4 to 2.9 minutes (16%), 5.2 to 4.2 minutes (20%), or 10.6 to 8.0 minutes (24%) for the prostate cases. Conclusions: Delivery times of intensity modulated proton therapy can be reduced substantially without compromising robust plan quality. Shorter delivery times are likely to reduce treatment uncertainties and costs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗