Search NASA⌕ Search

SEARCH · Search NASA

Results for “Lab Capabilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Science Requirements and Conceptual Design for a Polarized Medium Energy Electron-Ion Collider at Jlab

Researchers have envisioned an electron-ion collider with ion species up to heavy ions, high polarization of electrons and light ions, and a well-matched center-of-mass energy range as an ideal gluon microscope to explore new frontiers of nuclear science. In its most recent Long Range Plan, the Nuclear Science Advisory Committee (NSAC) of the US Department of Energy and the National Science Foundation endorsed such a collider in the form of a 'half-recommendation.' As a response to this science need, Jefferson Lab and its user community have been engaged in feasibility studies of a medium energy polarized electron-ion collider (MEIC), cost-effectively utilizing Jefferson Lab's already existing Continuous Electron Beam Accelerator Facility (CEBAF). In close collaboration, this community of nuclear physicists and accelerator scientists has rigorously explored the science case and design concept for this envisioned grand instrument of science. An electron-ion collider embodies the vision of reaching the next frontier in Quantum Chromodynamics - understanding the behavior of hadrons as complex bound states of quarks and gluons. Whereas the 12 GeV Upgrade of CEBAF will map the valence-quark components of the nucleon and nuclear wave functions in detail, an electron-ion collider will determine the largely unknown role sea quarks play and for the first time study the glue that binds all atomic nuclei. The MEIC will allow nuclear scientists to map the spin and spatial structure of quarks and gluons in nucleons, to discover the collective effects of gluons in nuclei, and to understand the emergence of hadrons from quarks and gluons. The proposed electron-ion collider at Jefferson Lab will collide a highly polarized electron beam originating from the CEBAF recirculating superconducting radiofrequency (SRF) linear accelerator (linac) with highly polarized light-ion beams or unpolarized light- to heavy-ion beams from a new ion accelerator and storage complex. Since the very beginning, the design studies at Jefferson Lab have focused on achieving high collider performance, particularly ultrahigh luminosities up to 10{sup 34} cm{sup -2}s{sup -1} per detector with large acceptance, while maintaining high polarization for both the electron and light-ion beams. These are the two key performance requirements of a future electron-ion collider facility as articulated by the NSAC Long Range Plan. In MEIC, a new ion complex is designed specifically to deliver ion beams that match the high bunch repetition and highly polarized electron beam from CEBAF. During the last two years, both development of the science case and optimization of the machine design point toward a medium-energy electron-ion collider as the topmost goal for Jefferson Lab. The MEIC, with relatively compact collider rings, can deliver a luminosity above 10{sup 34} cm{sup -2}s{sup -1} at a center-of-mass energy up to 65 GeV. It offers an electron energy up to 11 GeV, a proton energy up to 100 GeV, and corresponding energies per nucleon for heavy ions with the same magnetic rigidity. This design choice balances the scope of the science program, collider capabilities, accelerator technology innovation, and total project cost. An energy upgrade could be implemented in the future by adding two large collider rings housed in another large tunnel to push the center-of-mass energy up to or exceeding 140 GeV. After careful consideration of an alternative electron energy recovery linac on ion storage ring approach, a ring-ring collider scenario at high bunch repetition frequency was found to offer fully competitive performance while eliminating the uncertainties of challenging R&D on ampere-class polarized electron sources and many-pass energy-recovery linacs (ERLs). The essential new elements of an MEIC facility at Jefferson Lab are an electron storage ring and an entirely new, modern ion acceleration and storage complex. For the high-current electron collider ring, the upgraded 12 GeV CEBAF SRF linac will serve as a full-energy injector, and, if needed, provide top-off refilling. The CEBAF fixed-target nuclear physics program can be simultaneously operated since the filling time of the electron ring is very short. The ion complex for MEIC consists of sources for polarized light ions and unpolarized light to heavy ions, an SRF ion linac with proton energy up to 280 MeV, a 3 GeV prebooster synchrotron, a large booster synchrotron for proton energy up to 20 GeV, and a medium-energy collider ring with energy up to 100 GeV. The ion complex can accelerate other species of ions with corresponding energies at each accelerating stage. There are three collision points planned for MEIC. Two of them are for collisions with medium-energy ions; the third is for low energy ion beams stored in a dedicated low-energy compact storage ring, as a possible follow-on project.

43 PARTICLE ACCELERATORS↗

2014 WSEAT X-Prize

The 2014 WSEAT X-Prize is modeled as a double blind study to challenge the computational and material mechanics communities methodologies to develop better capabilities in modeling and experimentation to predict the failure in ductile metals. The challenge is presented as a distinct, yet relatively, simple geometry with all reported modeling predictions blind to each of the modeling teams. The experimental testing is validated by two independent test labs to confirm the experimentally observed behavior and results are unbiased and repeatable. The WSEAT X-Prize was issued to both external participants and internal participants as the Sandia Fracture Challenge 2 (SFC2) on May 30, 2014. A Challenge Supplemental Information Packet was sent to participants on August 13, 2014 to Prior years SFCs focused on the ability to predict failures under a quasi-static loading condition that focused on either a shear or tensile-dominated failure mode. This year’s challenge focuses on a geometry with a shear and/or tensile-dominated failure mode influenced by a moderate strain-rate ductile fracture in a metallic alloy.

36 MATERIALS SCIENCE↗

NREL Facilities Accelerate Marine Energy Technology Development [Poster]

Once marine energy device developers have a theoretical design in mind, it's time to transform that idea into a commercially ready device. And for that, they can turn to experts at the National Renewable Energy Laboratory (NREL). NREL's marine energy researchers have extensive experience moving technology ideas from prototype manufacturing through laboratory and field validation. The lab's facilities cover five phases of the validation life cycle to ensure marine energy technologies can survive harsh open-water environments. From prototype fabrication to grid integration at all scales, NREL offers end-to-end marine energy device design and validation capabilities.

16 TIDAL AND WAVE POWER↗

LDRD for a high-current polarized-beam photogun

The electron accelerator driving the Ce+BAF conversion target requires a spin-polarized photogun capable of delivering a CW beam current of at least 1 mA. As the high beam current limits the useful operating time of the gun between photocathode reactivations due to ion back-bombardment, it is critical to increase the charge lifetime. A Jefferson Lab LDRD project aims to calibrate the simulation models needed to predict photocathode lifetime as a function of electrostatic optics and drive laser parameters in order to design a gun providing at least 1000 C charge lifetime. A prototype gun demonstrating the validity of the scaling predictions will be built and tested at the Gun Test Stand. I will describe the background and progress of this project and give an outlook on the expected performance.

Bruker, Max [Thomas Jefferson National Accelerator↗

Opportunities for research on Space Station Freedom

NASA has allocated research accommodations on Freedom (equipment, utilities, etc.) to the program offices that sponsor space-based research and development as follows: Space Science and Applications (OSSA)--52 percent, Commercial Programs (OCP)--28 percent, Aeronautics and Space Technology (OAST)--12 percent, and Space Flight (OSF)--8 percent. Most of OSSA's allocation will be used for microgravity and life science experiments; although OSSA's space physics, astrophysics, earth science and applications, and solar system exploration divisions also will use some of this allocation. Other Federal agencies have expressed an interest in using Space Station Freedom. They include the National Institutes of Health (NIH), U.S. Geological Survey, National Science Foundation, National Oceanic and Atmospheric Administration, and U.S. Departments of Agriculture and Energy. Payload interfaces with space station lab support equipment must be simple, and experiment packages must be highly contained. Freedom's research facilities will feature International Standard Payload Racks (ISPR's), experiment racks that are about twice the size of a Spacelab rack. ESA's Columbus lab will feature 20 racks, the U.S. lab will have 12 racks, and the Japanese lab will have 10. Thus, Freedom will have a total of 42 racks versus 8 for Space lab. NASA is considering outfitting some rack space to accommodate small, self-contained payloads similar to the Get-Away-Special canisters and middeck-locker experiment packages flown on Space Shuttle missions. Crew time allotted to experiments on Freedom at permanently occupied capability will average 25 minutes per rack per day, compared to six hours per rack per day on Spacelab missions. Hence, telescience--the remote operation of space-based experiments by researchers on the ground--will play a very important role in space station research. Plans for supporting life sciences research on Freedom focus on the two basic goals of NASA 's space life sciences program: to ensure the health, safety, and productivity of humans in space and to acquire fundamental knowledge of biological processes. Space-based research has already shown that people and plants respond the same way to the microgravity environment: they lose structure. However, the mechanisms by which they respond are different, and researchers do not yet know much about these mechanisms. Life science research accommodations on Freedom will include facilities for experiments designed to address this and other questions, in fields such as gravitational biology, space physiology, and biomedical monitoring and countermeasures research.

Phillips, Robert W.↗

Implementing Ethernet Services on the Payload Executive Processor (PEP)

The Ethernet interface is more common and easier interface to implement for payload developers already familiar with Ethernet protocol in their labs. The Ethernet interface allows for a more distributed payload architecture. Connections can be placed in locations not serviced by the PEP 1553 bus. The Ethernet interface provides a new access port into the PEP so as to use the already existing services. Initial capability will include a subset of services with a plan to expand services later.

Pruett, David↗

Surrogate Post-Detonation Urban Debris (SPUD): Standard Reference Materials 4600 and 4601

If a terrorist nuclear explosion were to occur in the United States, high-quality (accurate and precise) legally defensible nuclear forensics measurements will be required to assure the certainty and confidence needed, for conclusions drawn from these data will be coupled with law enforcement and intelligence information for the purposes of attribution and retribution. Standard Reference Materials (SRMs)/Certified Reference Materials (CRMs) establish the traceability, accuracy, and precision of nuclear forensic measurements and provide the ability to benchmark measurement methods essential to meeting the requirements of legal scrutiny. Currently there is a critical shortage of key SRMs/CRMs required for accurate and precise measurements that are fundamental to nuclear measurements supporting pre- and post-detonation nuclear forensics. Supplies either do not exist, are not good enough, are in short supply, and/or are very expensive. The radionuclide measurement techniques and data quality objectives for pre- and post-detonation nuclear forensics are quite different than the applications for which the current suite of available SRMs/CRMs was developed. Specifically, 1) modern mass spectrometry methods have largely replaced traditional activity-based measurement methods for quantifying small quantities of long-lived radionuclides and most trace radionuclide SRMs/CRMs are certified for activity and are thus not adequate for current applications, 2) modern instrumental methods are capable of higher precision than historic measurement techniques, and in some cases exceed the precision of the available SRMs/CRMs, and 3) the quality assurance requirements for pre- and post-detonation nuclear forensics are such that the existing cadre of SRMs/CRMs does not adequately support the needs for method validation. There are numerous governmental stakeholders both within the US (DOE, DoD) and internationally (IAEA, JRC-ITU) whose missions are either directly involved with nuclear forensics measurements or rely on the forensic data obtained to make the exacting policy decisions (DOJ (FBI), DHS, CIA, DIA, DoD) associated with disrupting the production of illicit nuclear materials, interdicted nuclear materials or a nuclear/radiological detonation event. Starting in 2008 the DHS NTNFC, in collaboration with NBL and NIST, took on the production of suitable SRMs/CRMs for the pre-detonation nuclear forensics community. Two CRMs have been released since the start of this effort and two more are slated for completion in 2016. More recently, NIST, as a part of its mission as the US National Metrology Institute (NMI) to deliver standards (providing traceability) and foster homeland security, has launched the first certification campaign of a measurement traceable post nuclear detonation SRM. NIST, in cooperation with partner labs (AFIT (DoD), FBI (DOJ), and NPL) and with support from the FBI, has developed two Surrogate Post-Detonation Urban Debris (SPUD) Standard Reference Materials (SRMs) - SRM 4600 and 4601. These SRMs have been developed to simulate the expected debris mixture from the detonation of an Improvised Nuclear Device (IND) in an urban environment, which is capable of producing fresh fission as well as activation products. The elemental composition of the vitrified debris materials is a composite of minerals and metals characteristic of the concrete and steel, the building materials that would be exposed to a nuclear detonation and whose resulting activation products would be found in rubble samples collected for forensics evidence and attribution. Additionally, because post-detonation samples would also contain short-lived fission products, the debris materials have been doped with Uranium (U). To create the nuclear fission products, samples of the SPUD materials can be placed in a well-characterized nuclear reactor and exposed to a set neutron flux and energy, causing the encased U atoms to split and yield short-lived fission products. Because a known amount of U is added to the SPUD materials it is feasible to determine the concentration of the resulting fission products. The subsequent irradiated SPUD glass would be chemically similar to samples that would be generated in an actual detonation, and thus can serve as a standardized reference material for nuclear forensic post detonation measurements. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

PULSAR: A High-Repetition-Rate, High-Power, CE Phase-Locked Laser for the J.R. Macdonald Laboratory at Kansas State University

This instrumentation grant funded the development and installation of a state-of-the-art laser system to be used for the DOE funded research at the J.R. Macdonald Laboratory at Kansas State University. Specifically, we purchased a laser based on the KMLABs Red-Dragon design, which has a high repetition rate of 10-20 kHz crucial for multi-parameter coincidence measurements conducted in our lab. This laser system is carrier-envelope phase (CEP) locked and provides pulses as short as 21 fs directly from the amplifier (see details below). In addition, we have developed a pulse compression setup that provides sub 5 fs pulses and a CEP tagging capability that allows for long measurements of CEP dependent processes.

47 OTHER INSTRUMENTATION↗

2017 Report for New LANL Physical Vapor Deposition Capability

There is an urgent need at LANL to achieve uniform, thin film actinide targets that are essential for nuclear physics experiments. The target preparation work is currently performed externally by Professor Walter Loveland at Oregon State University, who has made various evaporated actinide targets such as Th and U for use on several nuclear physics measurements at LANSCE. We are developing a vapor deposition capability, with the goal of evaporating Th and U in the Actinide Research Facility (ARF) at TA-48. In the future we plan to expand this work to evaporating transuranic elements, such as Pu. The ARF is the optimal location for evaporating actinides because this lab is specifically dedicated to actinide research. There are numerous instruments in the ARF that can be used to provide detailed characterization of the evaporated thin films such as: Table top Scanning Electron Microscope, In-situ X-Ray Diffraction, and 3D Raman spectroscopy. These techniques have the ability to determine the uniformity, surface characterization, and composition of the deposits.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SRF Cavity Fault Classification and Prediction at Jefferson Lab

Over the last few years several machine learning projects at Jefferson Lab have had a common focus to optimize operation of superconducting RF (SRF) cavities in the Continuous Electron Beam Accelerator Facility (CEBAF). In this talk we highlight work to identify and classify types of faults from C100-type cavities and then to extend those capabilities to provide real-time fault prediction. Early prediction may enable mitigation strategies to prevent some types of faults. In our approach we apply a two-step fault prediction pipeline. In the first step, a model distinguishes between faulty and normal signals. In the second step, signals flagged as faulty by the first model are classified into one of seven fault types based on learned signatures in the data. Initial results show that our model can successfully predict most fault types 200 ms before onset. In additional to model performance, we also highlight challenges in working with real-world data and challenges for deploying models.

Tennant, C.↗

Lead tungstate calorimeters at Jefferson Lab and perspectives for the Electron–Ion Collider

Electromagnetic calorimeters based on PbWO4 scintillating crystals have a widespread applica- tion in experiments at different accelerator facilities such as CERN, FNAL, GSI, and Jefferson Lab. The unique properties of PbWO4 crystals, including a small radiation length and Molire radius, make them ideal for building high-granularity, radiation-hard detectors. This enables excellent spa- tial separation and energy resolution of reconstructed electromagnetic showers, making PbWO4 crystals the material of choice for numerous experiments. Lead tungstate calorimeters have been successfully used in several experiments at Jefferson Lab. Two large-scale detectors have been re- cently fabricated for future experiments : the Neutral Particle Spectrometer and the lead tungstate calorimeter of the GlueX detector. The future application of PbWO4 crystals in the ElectronIon Collider further highlights their ongoing importance in advancing experimental capabilities. In planning new experiments, the development of calorimeter instrumentation technologies becomes paramount. The integration of modern photodetectors, such as Silicon photomultipliers that are capable of operating in strong magnetic fields, and the implementation of streaming readout data acquisition systems, sophisticated shower reconstruction algorithms, and real-time data analysis are some examples of the continuously growing requirements of experimental setups. I will give an overview of the lead tungstate scintillating calorimeters and discuss some recent advancement in the calorimeter instrumentation.

Somov, Alexander↗

Northern Virginia Community College Training for Biotechnology Workers (Final Report)

The intent of this project was to expand Northern Virginia Community College's capability to offer training to support the Biotechnology Industry in the northern Virginia region. The general goal of this project was to create a College Biotechnology Program; specific goals of the project were to a) design curricula/courses to prepare students to become entry-level lab technicians, b) redesign and equip lab space to better suit the needs of the program, c) develop partnerships with the local industry through outreach and the formation on an advisory board, d) recruit students into the program, and e) provide instructional support for local high school teachers. At the end of the grant period, NOVA has successfully created two new curricula in biotechnology: an Associate of Applied Science (A.A.S.) in Biotechnology (initiated in Fall 2008) and a Career Studies Certificate for Biotechnology Lab Technicians (to be initiated in Fall 2010). These curricula were designed with advice from an external advisory committee which is comprised of representatives from industry, transfer institutions and high school administrators. To date, almost all courses have been designed and piloted; the equipment needed for the courses and the initial supplies were paid for by the grant as was the re-modeling of some lab space to be used for the biotech courses. In order to market the program, the NOVA Biotech Program has also established relationships with the local high schools. Presentations were given at several local high schools and on-site workshops were held for high school students and teachers. As a result, close to 1000 students have attended program open houses, presentations within the high schools, or workshops held in the summer. Over 100 teachers have received information and/or training in biotechnology. These outreach efforts as well as high quality curricula have started to attract a number of students to the program – for example, there are currently 70 students enrolled in the A.A.S. program. The first students in the biotech program are expected to graduate in Spring 2011; already, students enrolled in the biotech program/courses have obtained jobs or internships in several local companies. Our current goal continues to be to foster the formation of a regional biotech education pipeline into the local industry which includes the recruitment of individuals into the NOVA Biotech Program, the training and graduation of highly-skilled lab technicians, and the placement of graduates in local biotech industry jobs.

99 GENERAL AND MISCELLANEOUS↗

3-D Visualization in Support of Advanced Propulsion

Young computer graphics enthusiasts today might think they are pioneers of new technology. On the contrary-computer graphics experimentation began in the 1940s. A rich and eventful history exists in a short timeframe of six decades. The first graphics software was developed as "a tool for scientists and engineers in government and corporate research centers such as Bell Labs and Boeing." Computer graphics software today includes anything from vector-based page layout packages to extremely sophisticated three-dimensional design and animation software and everything in-between. The realm of this summer faculty fellowship project required three-dimensional (3D) digital capabilities. Therefore, the remainder of the paper will focus only on this facet of the graphics industry.

Jan P. Kyzar↗

Integration of detector into interaction region at MEIC

The Jefferson Lab's Medium-energy Electron Ion Collider (MEIC) is proposed as a next-generation facility for the study of strong interaction (QCD). Accessing the relevant physics requires a full-acceptance detector with a dedicated small-angle high-resolution detection system capable of covering a wide range of momenta (and charge-to-mass ratios) with respect to the original ion beam. We present a design of such a detection system integrated into the collider's interaction region, in which full acceptance is attained by letting small-angle collision products pass through the nearest elements of the machine final-focusing system for further detection. The proposed design is consistent with the current collider optics and demonstrates an excellent performance in terms of detector acceptance and resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Additive Manufacturing Case Study

Geothermal technologies include an extremely wide range of products required for well construction, completion, production, intervention and surface energy conversion activities. Many of these products are geometrically complex, require multi-step and highly specialized fabrication processes, and are expensive due to the low production numbers typically associated with the geothermal market. These challenges along with the high temperature demands of the geothermal environment have also hindered the adoption of many tools routinely used in the oil & gas industry.Recent advancements in Additive Manufacturing (AM) materials of construction, build volumes and part quality have transitioned the technology from primarily cosmetic prototyping applications to the point where AM can be used to make production parts, even for the most demanding applications. These improved AM capabilities along with the inherent ability of AM to produce complex parts and, in some cases, geometries that cannot be manufactured using conventional casting, machining and joining fabrication approaches motivate an exploration of its potential to positively impact geothermal well construction and operations technologies.Sandia National Labs collaborated with Oak Ridge National Laboratory on a case study examining additive manufacturing opportunities for Geothermal applications. The study focused on designing components with improved performance characteristics that cannot be fabricated conventionally. A rotor for a downhole motor was chosen based on the potential for improving its rotational dynamics. Topology optimization was used as a design method to reduce the rotational inertia of the part while preserving sufficient rotational stiffness to transmit the torque required for the drilling application. The optimization resulted in a nearly 50% reduction in polar moment of inertia while maintaining other desired performance characteristics. The design developed using the topology optimization approach was fabricated using additive manufacturing and cannot be fabricated conventionally. This paper will discuss the design approach, performance improvements and manufacturing methods used to produce the part.

Polsky, Yarom↗

Co-Simulation of PSS/E, OpenDSS, and PSCAD for Power Systems Stability Analysis With Inverter-Based Resources: Preprint

The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement of the Neutron Elastic Electromagnetic Form Factor Ratio at Large Momentum Transfer

Exploring nucleon structure is vital both for understanding its origin and existence as well as for the advancement of the sciences. It helps us answer key questions such as how quark and gluon dynamics create 99% of the nucleon mass. Electron- nucleon scattering has been widely used for precision studies of the nucleon and nuclear structure since the Nobel Prize winning investigations by Robert Hofstadter and collaborators in the 1950s. These studies provide information about the spatial charge and current densities of the nucleon in terms of the electromagnetic form factors. The form factors are functions of four momentum transfer squared (Q2). Extending the electromagnetic form factor measurements to higher Q2 plays a critical role in furthering the understanding of nucleon structure. This motivated the Super BigBite Spectrometer (SBS) program at Jefferson Lab. The open nature of the spectrometers and the direct line of sight from the target to the tracking detector locations in experimental setups such as SBS creates high levels of background at the detectors. This necessitates the use of tracking detectors with high rate capability and good position resolution. Gas Electron Multiplier (GEM) detectors are an excellent choice for tracking detectors in such experiments. Understanding the performance of the GEM detectors is important not just for SBS experiments but also for future high-luminosity experiments. This thesis reports the exploratory results from the measurement of the neutron elastic electromagnetic form factor ratio (Gn E/Gn M) at high momentum transfer. A longitudinally polarized electron beam was scattered off a polarized 3He target, used as an effective polarized neutron target. In this experiment, the polarized 3He target achieved a world record polarization weighted luminosity at a beam current of 45 µA. Double spin asymmetry of the scattered neutron events is used to extract the neutron form factor ratio. Measurements were taken at Q2 = 3.0, 6.8, 9.8 (GeV/c)2. The lowest Q2 measurement is in good agreement with the existing world data, and the higher-Q2 measurements extend the Q2 reach well beyond the existing world data and are expected to remain unmatched for a long time.

Gamage, Vimukthi Haththotuwa [Univ. of Virginia, C↗

HPC top 10 InfiniBand Machine : a 3D Torus IB interconnect on Red Sky.

This presentation discusses the following topics: (1) Red Sky Background; (2) 3D Torus Interconnect Concepts; (3) Difficulties of Torus in IB; (4) New Routing Code for IB a 3D Torus; (5) Red Sky 3D Torus Implementation; and (6) Managing a Large IB Machine. Computing at Sandia: (1) Capability Computing - Designed for scaling of single large runs, Usually proprietary for maximum performance, and Red Storm is Sandia's current capability machine; (2) Capacity Computing - Computing for the masses, 100s of jobs and 100s of users, Extreme reliability required, Flexibility for changing workload, Thunderbird will be decommissioned this quarter, Red Sky is our future capacity computing platform, and Red Mesa machine for National Renewable Energy Lab. Red Sky main themes are: (1) Cheaper - 5X capacity of Tbird at 2/3 the cost, Substantially cheaper per flop than our last large capacity machine purchase; (2) Leaner - Lower operational costs, Three security environments via modular fabric, Expandable, upgradeable, extensible, and Designed for 6yr. life cycle; and (3) Greener - 15% less power-1/6th power per flop, 40% less water-5M gallons saved annually, 10X better cooling efficiency, and 4x denser footprint.

99 GENERAL AND MISCELLANEOUS↗