Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leak Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Molten Salt Loop Operational Experience and Test Campaigns in FY24

The Facility to Alleviate Salt Technology Risks (FASTR) at the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature chloride salt systems (Figure 1). FASTR is primarily constructed using alloy C-276 and is designed to operate at temperatures of up to 725°C. The facility is loaded with 250 kg of NaCl-KCl-MgCl 2 salt. This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. The salt was purified in 2020 and 2022, and the pumped loop first operated in December 2022. FASTR is a unique US capability for high-temperature molten halide salt testing. FASTR’s scale, co located purification system, and relatively large power (465 kW) differentiates it from other testing systems. Furthermore, access to the DOE-supported facility and efficient communication of results— which are generally disseminated publicly—distinguish FASTR as being broadly significant throughout the molten salt reactor community. FASTR is similar to ORNL’s Liquid Salt Test Loop (LSTL), although FASTR contains chloride-based salt instead of the fluoride-based salt (LiF-NaF-KF) found in LSTL. Furthermore, FASTR is approximately 2× larger than LSTL in terms of pipe size and length, power, salt volume, flow rate, and number of thermocouples. The LSTL first operated in 2016. At the end of FY23, there was a suspected gas leak in the LSTL that halted operation. At the start of FY24, a leak in the LSTL pump’s tank gas space was confirmed. Because the gas-space leak prevented operation of LSTL, FY24 efforts were focused on operation of FASTR. This report summarizes the progress made during FY24 in support of the DOE Office of Nuclear Energy (DOE-NE) work package, AT-24OR070202 Salt Loop and Capability for Testing Sensors and Off Gas Components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Small-Scale Spray Releases: Orifice Plugging Test Results

One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities, is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations published in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials present in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty introduced by extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches in which the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are largely absent. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine the aerosol release fractions and aerosol generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents (AFA) was assessed with most of the simulants. Orifices included round holes and rectangular slots. Much of the testing was conducted at pressures of 200 and 380 psi, but some tests were conducted at 100 psi. Testing the largest postulated breaches was deemed impractical because of the large size of some of the WTP equipment. The purpose of the study described in this report is to provide experimental data for the first key technical area, potential plugging of small breaches, by performing small-scale tests with a range of orifice sizes and orientations representative of the WTP conditions. The simulants used were chosen to represent the range of process stream properties in the WTP. Testing conducted after the plugging tests in the small- and large-scale test stands addresses the second key technical area, aerosol generation. The results of the small-scale aerosol generation tests are included in Mahoney et al. 2012. The area of spray generation from large breaches is covered by large-scale testing in Schonewill et al. 2012.

orifice plugging↗

Detection of internal defects in a liquid natural gas tank by use of infrared thermography

The use of an infrared scanning technique to detect defects in the secondary barrier of a liquid natural gas tank is described. The method works by detecting leak-caused temperature differences as low as 0.2 K, but can provide only an approximate idea of the extent of the defect. The nondestructive method was tested in a study of a LNG tank already at its location in a ship; the secondary barrier was located inside the tank wall. Defective areas indicated by the infrared radiometric measurements were confirmed by other probe techniques and by physical examination.

Kantsios, A. G.↗

Decomposing Solid Micropropulsion Nozzle Performance Issues

Micropropulsion technology is essential to the success of miniaturized spacecraft and can provide ultra-precise propulsion for small spacecraft. NASA Glenn Research Center has envisioned a micropropulsion concept that utilizes decomposing solid propellants for a valveless, leak-free propulsion system. Among the technical challenges of this decomposing solid micropropulsion concept is optimization of miniature, rectangular nozzles. A number of flat micronozzles were tested with ambient-temperature nitrogen and helium gas in a vacuum facility. The thrusters were etched out of silicon and had throat widths on the order of 350 microns and throat depths on the order of 250 microns. While these were half-sections of thrusters (two would be bonded together before firing), testing provided the performance trend for nozzles of this scale and geometry. Area ratios from 1 to 25 were tested, with thrust measured using an inverted pendulum thrust stand for nitrogen flows and a torsional thrust stand for helium. In the nitrogen testing, peak nozzle performance was achieved around area ratio of 5. In the helium series, nozzle performance peaked for the smallest nozzle tested area ratio 1.5. For both gases, there was a secondary performance peak above area ratio 15. At low chamber pressures (< 1.6 atm), nitrogen provided higher nozzle performance than helium. The performance curve for helium was steeper, however, and it appeared that helium would provide better performance than nitrogen at higher chamber pressures.

Reed, Brian↗

Large-Scale Spray Releases: Initial Aerosol Test Results

One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce.

Schonewill, Philip P.↗

Small-Scale Spray Releases: Initial Aerosol Test Results

One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and net generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of antifoam agents was assessed with most of the simulants. Orifices included round holes and rectangular slots. For the combination of both test stands, the round holes ranged in size from 0.2 to 4.46 mm. The slots ranged from (width × length) 0.3 × 5 to 2.74 × 76.2 mm. Most slots were oriented longitudinally along the pipe, but some were oriented circumferentially. In addition, a limited number of multi-hole test pieces were tested in an attempt to assess the impact of a more complex breach. Much of the testing was conducted at pressures of 200 and 380 psi, but some tests were conducted at 100 psi. Testing the largest postulated breaches was deemed impractical because of the much larger flow rates and equipment that would be required. This report presents the experimental results and analyses for the aerosol measurements obtained in the small-scale test stand. It includes a description of the simulants used and their properties, equipment and operations, data analysis methodologies, and test results. The results of tests investigating the role of slurry particles in plugging small breaches are reported in Mahoney et al. (2012). The results of the aerosol measurements in the large-scale test stand are reported in Schonewill et al. (2012) along with an analysis of the combined results from both test scales.

Mahoney, Lenna A.↗

Fatigue induced cracking in aluminum LN-2 shroud of 39 foot vacuum chamber

Fourteen years after completion of Ford's 39-foot space simulation chamber, leaks began to appear in its LN2 shroud. Although the shroud had been tight since its acceptance, cracks appeared in 1983 in some of the field welds of the one inch tubes which interconnect the LN2 panels. The resulting leaks were large enough to prevent pump down to high vacuum and could be heard easily when the chamber was at ambient conditions. New cracks appeared during each thermal cycle making it impossible to utilize the chamber for thermal vacuum testing. The analysis presented here implies that many, if not all, of the aluminum LN2 shrouds now in use may be in various stages of fatigue failure. The probability is high that fatigue cracks are working through the aluminum tubing in heat-affected zones of some field welds. The cracks may not be apparent yet, but after the shroud has experienced a certain number of thermal cycles these cracks will work through the material and become serious leaks. Fortunately, appropriate planning, analysis, and checking can, with a relatively small expenditure of money, help to avoid large and unexpected shroud failures and keep the chamber operational as long as it is needed.

Edwards, A. A.↗

Verification Testing and Veg-05 Tomato Crop Production on the International Space Station

VEG-05 is an experiment to better define best practices for crop production and handling in space. Light can impact the growth habit, yield, nutritional composition, microbial levels, and flavor within crops and VEG-05 used the Veggie facilities on the International Space Station to grow ‘Red Robin’ dwarf tomatoes under different spectral compositions to assess these characteristics. Prior to launch, both a science verification test (SVT), and an experiment verification test (EVT) were conducted. SVT, and a previous fertilizer test, grew plants in both plant pillows and PONDS units and tested different fertilizer treatments, with each test under one of the light conditions. EVT used only plant pillows with the highest fertilizer composition tested, and two Veggie units were utilized. One Veggie had light settings consisting of equal levels of red: blue light while the second Veggie had a 90:10 ratio of red: blue light, both with the addition of ~10% green. For SVT, under the equal red: blue light treatment, fruit ripening in plant pillows was delayed. For EVT we saw fruit ripening earlier, especially in the red-rich treatment. In SVT we had mostly daily watering, and this led to excess water in plant pillows which leaked and caused fungus to grow. We reduced this excess in EVT, however, wilting events occurred. Regardless, more than 10 fruit were produced from each plant on average, with the high red treatment producing slightly heavier fruit. Microbial testing from fruit indicated that fruit were safe for consumption. VEG-05 flight operations ran December 2022 and March 2023, with considerable challenges in watering and unexpectedly low humidity on ISS during critical periods. Only 12 ripe fruit formed, and all were returned. Fruit and other samples are currently being analyzed. This research was co-funded by NASA’s Human Research Program and Space Biology.

Gioia Donna Massa↗

Verification Testing and VEG-05 Tomato Crop Production on the International Space Station

VEG-05 is an experiment to better define best practices for crop production and handling in space. Light can impact the growth habit, yield, nutritional composition, microbial levels, and flavor within crops and VEG-05 used the Veggie facilities on the International Space Station to grow ‘Red Robin’ dwarf tomatoes under different spectral compositions to assess these characteristics. Prior to launch, both a science verification test (SVT), and an experiment verification test (EVT) were conducted. SVT, and a previous fertilizer test, grew plants in both plant pillows and PONDS units and tested different fertilizer treatments, with each test under one of the light conditions. EVT used only plant pillows with the highest fertilizer composition tested, and two Veggie units were utilized. One Veggie had light settings consisting of equal levels of red: blue light while the second Veggie had a 90:10 ratio of red: blue light, both with the addition of ~10% green. For SVT, under the equal red: blue light treatment, fruit ripening in plant pillows was delayed. For EVT we saw fruit ripening earlier, especially in the red-rich treatment. In SVT we had mostly daily watering, and this led to excess water in plant pillows which leaked and caused fungus to grow. We reduced this excess in EVT, however, wilting events occurred. Regardless, more than 10 fruit were produced from each plant on average, with the high red treatment producing slightly heavier fruit. Microbial testing from fruit indicated that fruit were safe for consumption. VEG-05 flight operations ran December 2022 and March 2023, with considerable challenges in watering and unexpectedly low humidity on ISS during critical periods. Only 12 ripe fruit formed, and all were returned. Fruit and other samples are currently being analyzed. This research was co-funded by NASA’s Human Research Program and Space Biology.

Gioia D. Massa↗

Advancing Development of Emissions Detection (Final Report)

This document is the final report to the U.S. Department of Energy (DOE for contract DE-FE0031873) awarded to Colorado State University (CSU). CSU and partners at Harrisburg University of Science and Technology, University of Texas Arlington, and University of Texas at Austin organized several testing rounds to provide knowledge focused on advancing the detection capabilities of emissions monitoring devices. With this funding opportunity the research group began by establishing the Advancing the Development of Emission Detection (ADED) program, with the goal focused on enhancing the accuracy, reliability, and field applicability of methane detection technologies. This effort aimed to address the critical challenges of identifying and quantifying methane emissions while enabling industry stakeholders to meet regulatory compliance and environmental sustainability goals. The program engaged with industry, government, and technology stakeholders to promote adoption and consensus on testing techniques for methane detection solutions. Methane, a potent greenhouse gas, contributes significantly to global warming, and the oil and natural gas (O&G) sector is a primary source of methane emissions. Regulatory measures such as leak detection and repair (LDAR) programs have been implemented to address emissions. However, traditional LDAR approaches, reliant on handheld and component-level measurements, are resource-intensive. To address these limitations and move with evolving regulations, advanced methane technologies are emerging. These solutions include ground-based sensors, mobile systems (e.g., drones, vehicles, and aircraft), and satellite-based platforms. They offer innovative capabilities for autonomous monitoring, larger spatial coverage, and emission quantification using methods such as tracer gas techniques and inverse modeling with Gaussian plume analysis. The ADED program began with creating protocols for methane controlled release (CR) testing these continuous monitoring (CM) and survey technologies that detect and monitor methane emissions at O&G facilities. The protocols were then implemented throughout testing of CM and survey devices at CSU’s Methane Emissions Technology Evaluation Center (METEC) facility from 2021 through 2024. As apart of the protocol, solutions that tested under the ADED program installed their solutions at METEC, documented their system under test, and provided detection reports to the METEC team for analysis. The METEC team would provide the solutions with analyzed reports of their emissions and ground truth data of the releases conducted during their testing session. Under the ADED program, CMs were also tested at O&G facilities for a six week test run of challenge release (ChR) releases. The findings from the ADED program underscore the critical role of collaborative research and innovation in tackling methane emissions, offering a pathway for the oil and gas sector to achieve significant environmental and economic benefits. Results from METEC testing saw improvement of performance and accuracy across all solutions over the extent of the ADED experiments. The results also showed a variance in CM solution performance between CRs and ChRs. That variance pushed the team to further analyze the differences between CR testing environments and field conditions. With the drive from regulations and that variance in field conditions, the ADED team began designing a new CR testing protocol and additions to the METEC testing facility. The METEC team is furthering the progress made through the ADED program with awarded funding from DE-FE0032276. This funding pushes the development of METEC’s addition with new equipment, allowing for an updated facility layout. METEC still facilitates for traditional facilities, with a legacy pad, while expanding an new design based on how O&G infrastructure has Final Report - Contract Number: DE-FE0031873 been changed over the last decade. Throughout the ADED program the team has also been working with international partners to ensure staying in the trend globally. International partners have been essential in moving the new protocol forward to implement into CR testing at the METEC facility in Spring 2025.

42 ENGINEERING↗

Diffusion of trace gases for leak detection - A study

Study reveals quantitative measurements of the diffusion of trace gases /Freon and helium/ injected into systems by different methods. Results show that uniform mixing does not always occur, thus evaluation of the system under test and establishment of the method of trace gas injection are mandatory.

Brown, J. L.↗

Progress on Advancing Robotic Ultrasonic Volumetric Inspection Technology for Hanford Under-tank Inspection - 19474

The Hanford River Protection Project is reliant on safe interim storage of high-level waste at the Hanford site and will continue to depend on it until the waste has been treated and vitrified by the Hanford Waste Treatment and Immobilization Plant (WTP). The Hanford double-shell tanks (DSTs) have provided interim storage since the DSTs were put into service (1971 - 1986) and the RPP will continue to rely on their service until least 2050, at which time the 27 in-service DSTs will be 14-54 years beyond their original design lives. As the DSTs continue to age and be operated beyond design life, reliable leak integrity assessments of primary tanks and secondary liners will become increasingly important in order to provide situational awareness to tank operations personnel and to support risk-informed decisions on the selection of DSTs as waste feed staging tanks and the order and timing of future DST refurbishment or, alternatively, DST retrieval sequence. This paper summarizes progress made in fiscal year (FY) 2018 on the engineering of a robotic air-slot volumetric inspection system (RAVIS) that is designed to perform ultrasonic (volumetric) leak integrity inspections of physically inaccessible primary tank bottom plates and welds. Leak integrity inspections performed with the RAVIS will supplement today's primary tank leak integrity inspections, which are currently limited to physically accessible sidewall plates and welds. The RAVIS will be deployed into air slots of the insulating concrete (refractory) pad beneath the primary tanks and use its ultrasonic guided wave phased-array (GWPA) sensor to electronically steer an ultrasonic beam 360-degrees around the sensor to volumetrically examine adjacent carbon steel plates and welds covered by refractory pad material. Deployments of RAVIS down multiple air-slots will be performed to determine which regions of a tank bottom have sound leak integrity or which regions are in need of future wall thickness restoration or weld repair due to pitting corrosion, general corrosion, or heat/stress-induced cracks. The initial RAVIS design and the flaw detection test results for the first air-slot GWPA sensor that was designed to fit inside the air-slots will be presented in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lateral Earth Pressure at Rest and Shear Modulus Measurements on Hanford Sludge Simulants

This report describes the equipment, techniques, and results of lateral earth pressure at rest and shear modulus measurements on kaolin clay as well as two chemical sludge simulants. The testing was performed in support of the problem of hydrogen gas retention and release encountered in the double- shell tanks (DSTs) at the Hanford Site near Richland, Washington. Wastes from single-shell tanks (SSTs) are being transferred to double-shell tanks (DSTs) for safety reasons (some SSTs are leaking or are in danger of leaking), but the available DST space is limited.

08 HYDROGEN↗

AN ASSESSMENT OF THE SERVICE HISTORY AND CORROSION SUSCEPTIBILITY OF TYPE IV WASTE TANKS

Type IV waste tanks were designed and built to store waste that does not require auxiliary cooling. Each Type IV tank is a single-shell tank constructed of a steel-lined pre-stressed concrete tank in the form of a vertical cylinder with a concrete domed roof. There are four such tanks in F-area, Tanks 17-20F, and four in H-Area, Tanks 21-24H. Leak sites were discovered in the liners for Tanks 19 and 20F in the 1980's. Although these leaks were visually observed, the investigation to determine the mechanism by which the leaks had occurred was not completed at that time. Therefore, a concern was raised that the same mechanism which caused the leak sites in the Tanks in F-area may also be operable in the H-Area tanks. Data from the construction of the tanks (i.e., certified mill test reports for the steel, no stress-relief), the service history (i.e., waste sample data, temperature data), laboratory tests on actual wastes and simulants (i.e., electrochemical testing), and the results of the visual inspections were reviewed. The following observations and conclusions were made: (1) Comparison of the compositional and microstructural features indicate that the A212 material utilized for construction of the H-Area tanks are far more resistant to SCC than the A285 materials used for construction of the F-Area tanks. (2) A review of the materials of construction, temperature history, service histories concluded that F-Area tanks likely failed by caustic stress corrosion cracking. (3) The environment in the F-Area tanks was more aggressive than that experienced by the H-Area tanks. (4) Based on a review of the service history, the H-Area tanks have not been exposed to an environment that would render the tanks susceptible to either nitrate stress corrosion cracking (i.e., the cause of failures in the Type I and II tanks) or caustic stress corrosion cracking. (5) Due to the very dilute and uninhibited solutions that have been stored in Tank 23H, vapor space corrosion has occurred on some of areas of the liner. The mild pitting that was observed is broad and shallow and has no structural impact. Further significant pit growth has not been observed since the 1980's.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An experimental evaluation of metallic diaphragms for positive fuel expulsion in the Atmosphere Explorer, hydrazine propulsion subsystem

Four Arde conospheroid metallic diaphragms were tested at NASA to evaluate their capability for use in the orbit adjust propulsion subsystem (OAPS) of the Atmosphere Explorer spacecraft (AE's C, D, and E). The diaphragms will be used for positive propellant expulsion and spacecraft center of mass (c.m.) control. A leak-free cycle life capability of nine reversals was demonstrated. The diaphragms rolled smoothly from ring to ring in a predictable manner on the first reversal. Varying amounts of diaphragm cocking and ring skipping were observed on subsequent reversals. The diaphragm pressure differential did not exceed 10 psid during any reversal. Cycle life capability, reversal mode, and pressure differential were not affected by sudden reversals, environmental tests, or 18,000 partial reversals. An expulsion efficiency of approximately 97 percent was demonstrated. The results of these tests show that metallic diaphragms can be used as an effective means of positive fuel expulsion; however, to achieve spacecraft c.m. control, the diaphragm must not be reversed prior to flight.

Woodruff, W. L.↗

Demonstration Testing for Ground Servicing of the Commercial Crew Vehicle Emergency Breathing Air Assembly

The new Commercial crew vehicle (CCV) Breathing Air Assembly (CEBAA) is a Composite Overwrapped Pressure Vessel (COPV) filled with high-pressure air, which is designed to provide portable emergency breathing air for up to five crew in the event of an ammonia leak aboard the International Space Station (ISS). Industrially, several common methods of delivering breathing air exist; however, ground processing constraints and flight requirements necessitate the more unusual approach of servicing a COPV with high purity gaseous nitrogen and oxygen serially to achieve a specific mixture of breathing air at approximately 4000 PSIA. A dwell period allows the gases to mix before sampling for composition verification. The novelty of this approach led to concerns about acceptable gas mixing and the ability to deliver accurate gas compositions. Tests examining mixing rate over a series of post-servicing dwell periods were conducted to determine the optimal time for achieving a homogeneous mixture. Further testing was conducted to examine process accuracy using temperature-pressure load criteria to target a specific concentration of oxygen and nitrogen. Test results show that while some stratification of nitrogen and oxygen was observed, a seven-day dwell is adequate time to achieve an acceptable level of mixing, and that existing ground support equipment can accurately service CEBAA COPVs to the required temperature, pressure and composition for flight.

Active Thermal↗

Noble and Major Gases Released from Rock Core Materials as Intrinsic Tracers for Detecting Carbon Dioxide Leakage – Laboratory Evaluation

The elemental and isotopic compositions of noble gases constitute a set of non-reactive geochemical tracers. Noble gases released from geological formations in contact with pore water acidified by leaked carbon dioxide (CO2) can potentially be employed as tracers for detection of CO2 leakage from storage reservoirs in carbon sequestration sites. In a set of laboratory tests, core materials from a stratigraphic borehole at the proposed FutureGen 2.0 carbon storage site (Jacksonville, IL, USA) were reacted with an aqueous acid to simulate contact with aqueous CO2 and the gas released from the reaction was collected. The major gas components, the noble gas concentrations and isotopic ratios were determined to evaluate the feasibility of using the released noble gases as tracers for crustal water-rock interactions. Experiments yielded several promising tracer candidates for intrinsic monitoring of CO2 leakage at the proposed FutureGen 2.0 site. The most robust signals stem from CH4 and 4He released by carbonates associated with dolomite and shale formations from the primary containment zone. No useful signal was obtained from the sandstone formation due to its very low yield of gas when acidified. Xenon released from the primary-containment zone also showed promise as a tracer, but a more robust analysis requires a different experimental set up. A general enrichment of CH4, N2 and light noble gas isotopes with respect to Ar abundance was observed and is consistent with the addition of major gases (CO2, CH4, and to a lesser extent N2) released by a combination of the decomposition of carbonate mineral phases and/or organic matter in the dolomite and shale formations. The enrichment of these major gases leads to enhanced signals from heterogeneous molecular and isotopic ratios including 3He/4He, 4He/22Ne, 20Ne/22Ne, 21Ne*/22Ne, 20Ne/36Ar, 84Kr/36Ar, 132Xe/36Ar, and 132Xe/84Kr, amongst others.

noble gases, tracers, carbon sequestration, CO2, i↗

Systems Modeling to Implement Integrated System Health Management Capability

ISHM capability includes: detection of anomalies, diagnosis of causes of anomalies, prediction of future anomalies, and user interfaces that enable integrated awareness (past, present, and future) by users. This is achieved by focused management of data, information and knowledge (DIaK) that will likely be distributed across networks. Management of DIaK implies storage, sharing (timely availability), maintaining, evolving, and processing. Processing of DIaK encapsulates strategies, methodologies, algorithms, etc. focused on achieving high ISHM Functional Capability Level (FCL). High FCL means a high degree of success in detecting anomalies, diagnosing causes, predicting future anomalies, and enabling health integrated awareness by the user. A model that enables ISHM capability, and hence, DIaK management, is denominated the ISHM Model of the System (IMS). We describe aspects of the IMS that focus on processing of DIaK. Strategies, methodologies, and algorithms require proper context. We describe an approach to define and use contexts, implementation in an object-oriented software environment (G2), and validation using actual test data from a methane thruster test program at NASA SSC. Context is linked to existence of relationships among elements of a system. For example, the context to use a strategy to detect leak is to identify closed subsystems (e.g. bounded by closed valves and by tanks) that include pressure sensors, and check if the pressure is changing. We call these subsystems Pressurizable Subsystems. If pressure changes are detected, then all members of the closed subsystem become suspect of leakage. In this case, the context is defined by identifying a subsystem that is suitable for applying a strategy. Contexts are defined in many ways. Often, a context is defined by relationships of function (e.g. liquid flow, maintaining pressure, etc.), form (e.g. part of the same component, connected to other components, etc.), or space (e.g. physically close, touching the same common element, etc.). The context might be defined dynamically (if conditions for the context appear and disappear dynamically) or statically. Although this approach is akin to case-based reasoning, we are implementing it using a software environment that embodies tools to define and manage relationships (of any nature) among objects in a very intuitive manner. Context for higher level inferences (that use detected anomalies or events), primarily for diagnosis and prognosis, are related to causal relationships. This is useful to develop root-cause analysis trees showing an event linked to its possible causes and effects. The innovation pertaining to RCA trees encompasses use of previously defined subsystems as well as individual elements in the tree. This approach allows more powerful implementations of RCA capability in object-oriented environments. For example, if a pressurizable subsystem is leaking, its root-cause representation within an RCA tree will show that the cause is that all elements of that subsystem are suspect of leak. Such a tree would apply to all instances of leak-events detected and all elements in all pressurizable subsystems in the system. Example subsystems in our environment to build IMS include: Pressurizable Subsystem, Fluid-Fill Subsystem, Flow-Thru-Valve Subsystem, and Fluid Supply Subsystem. The software environment for IMS is designed to potentially allow definition of any relationship suitable to create a context to achieve ISHM capability.

Figueroa, Jorge F.↗