Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Time structure of an accelerated beam using a radio-frequency quadrupole linac with direct plasma injection scheme

In direct plasma injection scheme, the relation between the ion current from a laser ion source and the accelerated beam current by a radio-frequency quadrupole (RFQ) linac was studied by a series of the following analyses. First, ion current at beam extraction was calculated from measured plasma parameters using a scaling law. Second, the beam emittance at the entrance of acceleration electrode region was evaluated by the simulation of the ion extraction out of the ion source plasma using the result of the first calculation. Last, the accelerated beam current could be reproduced by the simulation of beam acceleration using the results of the second. The second calculation revealed the time variation in the injected beam parameter to the RFQ linac. Then it was proved that the time structure of the accelerated beam was different from that of the injection beam because the degree of the matching between the injected beam emittance and the RFQ acceptance varied with time.

43 PARTICLE ACCELERATORS↗

CLIC RF High Power Production Testing Program

The CLIC Power Extraction and Transfer Structure (PETS) is a passive microwave device in which bunches of the drive beam interact with the impedance of the periodically loaded waveguide and generate RF power for the main linac accelerating structure. The demands on the high power production ({approx} 150 MW) and the needs to transport the 100 A drive beam for about 1 km without losses, makes the PETS design rather unique and the operation very challenging. In the coming year, an intense PETS testing program will be implemented. The target is to demonstrate the full performance of the PETS operation. The testing program overview and test results available to date are presented.

43 PARTICLE ACCELERATORS↗

Accelerated basis adaptation in homogeneous chaos spaces

Polynomial chaos expansions (PCE) provide an efficient approach to uncertainty quantification (UQ) and have been adapted to diverse applications across the spectrum of science and engineering. For situations involving large stochastic parameterizations, the curse of dimensionality renders PCE-based methods computationally prohibitive. A basis adaptation approach for PCE was proposed by Tipireddy and Ghanem (2014) which transforms the input random variables through an isometry such that sufficient probabilistic characterization of specific quantities of interest (QoI) is concentrated in an algebraic manifold embedded in the linear span of the dominant transformed variables. While quite versatile, that original version of the PCE basis adaptation exhibited slow convergence for a number of problems of practical significance. In the present paper, we propose two novel methods to accelerate the convergence of the original basis adaptation approach, thus expanding its reach while also providing insight into its performance. In the first method, information gained from a pilot PCE representation is used to correct the mean and Gaussian coefficients in the adapted space. By taking advantages of probabilistic information in higher dimensional adaptation gleaned from an initial adaptation, the second method updates the rotation matrix used to identify the dominant transformed variables. In this manner, the new rotation matrix concentrates even more probabilistic information in its first few dimensions. These two method can be combined to achieve even better performance, the combined method is referred to as sequentially optimized adaptation method. Here, the methods are demonstrated on an analytical test function and a model of a space structure with several sub-components and a non-smooth quantity of interest representing the maximum acceleration over time. Both methods achieve accelerated convergence of the basis adaptation approach with negligible additional costs.

Accelerated convergence↗

PROBING THE INNER JET OF THE QUASAR PKS 1510-089 WITH MULTI-WAVEBAND MONITORING DURING STRONG GAMMA-RAY ACTIVITY

We present results from monitoring the multi-waveband flux, linear polarization, and parsec-scale structure of the quasar PKS 1510 - 089, concentrating on eight major {gamma}-ray flares that occurred during the interval 2009.0-2009.5. The {gamma}-ray peaks were essentially simultaneous with maxima at optical wavelengths, although the flux ratio of the two wave bands varied by an order of magnitude. The optical polarization vector rotated by 720 deg. during a five-day period encompassing six of these flares. This culminated in a very bright, {approx}1 day, optical and {gamma}-ray flare as a bright knot of emission passed through the highest-intensity, stationary feature (the 'core') seen in 43 GHz Very Long Baseline Array images. The knot continued to propagate down the jet at an apparent speed of 22c and emit strongly at {gamma}-ray energies as a months-long X-ray/radio outburst intensified. We interpret these events as the result of the knot following a spiral path through a mainly toroidal magnetic field pattern in the acceleration and collimation zone of the jet, after which it passes through a standing shock in the 43 GHz core and then continues downstream. In this picture, the rapid {gamma}-ray flares result from scattering of infrared seed photons from a relatively slow sheath of the jet as well as from optical synchrotron radiation in the faster spine. The 2006-2009.7 radio and X-ray flux variations are correlated at very high significance; we conclude that the X-rays are mainly from inverse Compton scattering of infrared seed photons by 20-40 MeV electrons.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-BRA-01: A Real-Time Tumor Localization and Guidance Platform for Radiotherapy Using US and MRI

Purpose: To develop and validate a real-time motion management platform for radiotherapy that directly tracks tumor motion using ultrasound and MRI. This will be a cost-effective and non-invasive real-time platform combining the excellent temporal resolution of ultrasound with the excellent soft-tissue contrast of MRI. Methods: A 4D planar ultrasound acquisition during the treatment that is coupled to a pre-treatment calibration training image set consisting of a simultaneous 4D ultrasound and 4D MRI acquisition. The image sets will be rapidly matched using advanced image and signal processing algorithms, allowing the display of virtual MR images of the tumor/organ motion in real-time from an ultrasound acquisition. Results: The completion of this work will result in several innovations including: a (2D) patch-like, MR and LINAC compatible 4D planar ultrasound transducer that is electronically steerable for hands-free operation to provide real-time virtual MR and ultrasound imaging for motion management during radiation therapy; a multi- modal tumor localization strategy that uses ultrasound and MRI; and fast and accurate image processing algorithms that provide real-time information about the motion and location of tumor or related soft-tissue structures within the patient. Conclusion: If successful, the proposed approach will provide real-time guidance for radiation therapy without degrading image or treatment plan quality. The approach would be equally suitable for image-guided proton beam or heavy ion-beam therapy. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

Maps of CMB lensing deflection from N-body simulations in Coupled Dark Energy Cosmologies

We produce lensing potential and deflection-angle maps in order to simulate the weak gravitational lensing of the Cosmic Microwave Background (CMB) via ray-tracing through the COupled Dark Energy Cosmological Simulations (CoDECS), the largest suite of N-body simulations to date for interacting Dark Energy cosmologies. The constructed maps faithfully reflect the N-body cosmic structures on a range of scales going from the arcminute to the degree scale, limited only by the resolution and extension of the simulations. We investigate the variation of the lensing pattern due to the underlying Dark Energy (DE) dynamics, characterised by different background and perturbation behaviours as a consequence of the interaction between the DE field and Cold Dark Matter (CDM). In particular, we study in detail the results from three cosmological models differing in the background and perturbations evolution at the epoch in which the lensing cross section is most effective, corresponding to a redshift of ∼ 1, with the purpose to isolate their imprints in the lensing observables, regardless of the compatibility of these models with present constraints. The scenarios investigated here include a reference ΛCDM cosmology, a standard coupled DE (cDE) scenario, and a ''bouncing'' cDE scenario. For the standard cDE scenario, we find that typical differences in the lensing potential result from two effects: the enhanced growth of linear CDM density fluctuations with respect to the ΛCDM case, and the modified nonlinear dynamics of collapsed structures induced by the DE-CDM interaction. As a consequence, CMB lensing highlights the DE impact in the cosmological expansion, even in the degenerate case where the amplitude of the linear matter density perturbations, parametrised through σ{sub 8}, is the same in both the standard cDE and ΛCDM cosmologies. For the ''bouncing'' scenario, we find that the two opposite behaviours of the lens density contrast and of the matter abundance lead to a counter-intuitive effect, making the power of the lensing signal in this model lower by 10% than in the ΛCDM scenario. Moreover, we compare the behaviour of CDM and baryons in CoDECS separately, in order to isolate effects coming from the coupling with the DE component. We find that, in the bouncing scenario, baryons show an opposite trend with respect to CDM, due to the coupling of the latter with the DE component. These results confirm the relevance of CMB lensing as a probe for DE at the early stages of cosmic acceleration, and demonstrate the reliability of N-body based large scale CMB lensing simulations in the context of DE studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of beam loading and its compensation in the Compact Ultrafast Terahertz Free-Electron Laser injector linac

The RF properties of an accelerating structure, and the pulse structure and charge per bunch in the electron beam propagating through it are important parameters that determine the impact of beam loading in the structure. The injector linac of the Compact Ultrafast Terahertz Free-Electron Laser (CUTE-FEL) has been operated with two different pulse structures during initial commissioning experiments and the effect of beam loading on the accelerated electron beam parameters has been studied analytically for these two pulse structures. This paper discusses the analytical study of beam loading in a Standing Wave, Plane Wave Transformer linac employed in the CUTE-FEL setup, and a possible technique for its compensation for the electron beam parameters of the CUTE-FEL. A parametric study has been performed to study beam loading for different beam currents and to optimize injection time of the electron beam to compensate beam loading. Results from the parametric study have also been used to explain previously observed results from acceleration experiments in the CUTE-FEL setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an H{sup -} ion source for Japan Proton Accelerator Research Complex upgrade

A cesium (Cs) free H{sup -} ion source driven with a lanthanum hexaboride (LaB{sub 6}) filament was adopted as an ion source for the first stage of the Japan Proton Accelerator Research Complex (J-PARC). At present, the maximum H{sup -} ion current produced by the ion source is 38 mA, using which J-PARC can produce a proton beam power of 0.6 MW by accelerating it with the 181 MeV linac and the 3 GeV rapid cycling synchrotron. In order to satisfy the beam power of 1 MW required for the second stage of the J-PARC in the near future, we have to increase the ion current to more than 60 mA. Therefore, we have started to develop a Cs-seeded ion source by adding an external Cs-seeding system to a J-PARC test ion source that has a structure similar to that of the J-PARC ion source except for the fact that the plasma chamber is slightly larger. As a result, a H{sup -} ion current of more than 70 mA was obtained from the ion source using a tungsten filament instead of a LaB{sub 6} filament with a low arc discharge power of 15 kW (100 V, 150 A).

43 PARTICLE ACCELERATORS↗

Method and apparatus for recirculation with control of synchrotron radiation

A method for controlling beam quality degradation from ISR and CSR and stabilizing the microbunching instability (.mu.BI) in a high brightness electron beam. The method includes providing a super-periodic second order achromat line with each super period being individually linearly achromatic and isochronous, setting individual superperiod tunes to rational fractions of an integer (such as 4.sup.th or 6.sup.th integers), setting individual bend angles to be as small as practical to reduce driving terms due to dispersion and dispersive angle, and setting bend radii as large enough to suppress ISR but not negatively affect the radial dependence of CSR. The method includes setting the structure of the individual superperiods to minimize bend plane beam envelope values in the dipoles to reduce betatron response to a CSR event at a dispersed location, increasing beam angular divergence, and creating dispersion nodes in the dipoles to similarly reduce response to CSR events, and limit R.sub.56 modulation in order to mitigate .mu.BI.

42 ENGINEERING↗

Numerical insight into the seismic behavior of eight masonry towers in Northern Italy: FE pushover vs non-linear dynamic analyses

This study presents some FE results regarding the behavior under horizontal loads of eight existing masonry towers located in the North-East of Italy. The towers, albeit unique for geometric and architectural features, show some affinities which justify a comparative analysis, as for instance the location and the similar masonry material. Their structural behavior under horizontal loads is therefore influenced by geometrical issues, such as slenderness, walls thickness, perforations, irregularities, presence of internal vaults, etc., all features which may be responsible for a peculiar output. The geometry of the towers is deduced from both existing available documentation and in-situ surveys. On the basis of such geometrical data, a detailed 3D realistic mesh is conceived, with a point by point characterization of each single geometric element. The FE models are analysed under seismic loads acting along geometric axes of the plan section, both under non-linear static (pushover) and non-linear dynamic excitation assumptions. A damage-plasticity material model exhibiting softening in both tension and compression, already available in the commercial code Abaqus, is used for masonry. Pushover analyses are performed with both G1 and G2 horizontal loads distribution, according to Italian code requirements, along X+/− and Y+/− directions. Non-linear dynamic analyses are performed along both X and Y directions with a real accelerogram scaled to different peak ground accelerations. Some few results are presented in this paper. It is found that the results obtained with pushover analyses reasonably well fit expensive non-linear dynamic simulations, with a slightly less conservative trend.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stoichiometry and thickness dependence of superconducting properties of niobium nitride thin films

The current technology used in linear particle accelerators is based on superconducting radio frequency (SRF) cavities fabricated from bulk niobium (Nb), which have smaller surface resistance and therefore dissipate less energy than traditional nonsuperconducting copper cavities. Using bulk Nb for the cavities has several advantages, which are discussed elsewhere; however, such SRF cavities have a material-dependent accelerating gradient limit. In order to overcome this fundamental limit, a multilayered coating has been proposed using layers of insulating and superconducting material applied to the interior surface of the cavity. The key to this multilayered model is to use superconducting thin films to exploit the potential field enhancement when these films are thinner than their London penetration depth. Such field enhancement has been demonstrated in MgB{sub 2} thin films; here, the authors consider films of another type-II superconductor, niobium nitride (NbN). The authors present their work correlating stoichiometry and superconducting properties in NbN thin films and discuss the thickness dependence of their superconducting properties, which is important for their potential use in the proposed multilayer structure. While there are some previous studies on the relationship between stoichiometry and critical temperature T{sub C}, the authors are the first to report on the correlation between stoichiometry and the lower critical field H{sub C1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collective effects on the wakefield and stopping power of an ion beam pulse in plasmas

A two-dimensional (2D) particle-in-cell simulation is carried out to study the collective effects on the wakefield and stopping power for a hydrogen ion beam pulse propagation in hydrogen plasmas. The dependence of collective effects on the beam velocity and density is obtained and discussed. For the beam velocity, it is found that the collective effects have the strongest impact on the wakefield as well as the stopping power in the case of the intermediate beam velocities, in which the stopping power is also the largest. For the beam density, it is found that at low beam densities, the collective contribution to the stopping power increase linearly with the increase of the beam density, which corresponds well to the results calculated using the dielectric theory. However, at high beam densities, our results show that after reaching a maximum value, the collective contribution to the stopping power starts to decrease significantly with the increase of the beam density. Besides, at high beam densities, the wakefield loses typical V-shaped cone structures, and the wavelength of the oscillation wakefield increases as the beam density increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

H-mode accelerating structures with PMQ focusing for low-beta ion beams

We are developing high-efficiency normal-conducting RF accelerating structures based on inter-digital H-mode (IH) cavities and the transverse beam focusing with permanent-magnet quadrupoles (PMQ), for beam velocities in the range of a few percent of the speed of light. Such IH-PMQ accelerating structures following a short RFQ can be used in the front end of ion linacs or in stand-alone applications, e.g. a compact deuteron-beam accelerator up to the energy of several MeV. Results of combined 3-D modeling for a full IH-PMQ accelerator tank - electromagnetic computations, beam-dynamics simulations with high currents, and thermal-stress analysis - are presented. The accelerating field profile in the tank is tuned to provide the best beam propagation using coupled iterations of electromagnetic and beam-dynamics modeling. A cold model of the IH-PMQ tank is being manufactured.

43 PARTICLE ACCELERATORS↗

A mathematical model to systematically align superconducting radio frequency cavities employing the serial robot kinematic theory

In Superconducting Radio Frequency (SRF) cryomodules, precise alignment of cavities is necessary to ensure high beam quality and to increase the overall energetic efficiency. In the SSR1 (Single Spoke Resonator 1) cryomodule, the cavities are aligned using a system of seven screws which allows to control five Degree of Freedoms (DOFs). The relation between the rotation of each screw and the movement of the cavity is non-linear, thus the aligning process, currently based on a trial-and-error procedure, can be time consuming and affected by human error. In this paper the design of an alignment mathematical model, based on the serial robot kinematic, is described and tested on a SSR1 cavity. Furthermore, the goal of the proposed model is to give a step by step operational procedure that bring the SSR1 cavity to a desired location reducing the uncertainties related to the current operator-driven alignment process.

43 PARTICLE ACCELERATORS↗

Breakdown insensitive acceleration regime in a metamaterial accelerating structure

A new regime in radiofrequency (rf) breakdown, named the breakdown insensitive acceleration regime (BIAR), was observed in an 11.7 GHz metamaterial structure for wakefield acceleration driven by rf pulses with a duration of a few nanoseconds. In the BIAR, rf breakdown occurs without interrupting potential beam acceleration, resulting in greater resilience to breakdown. We have investigated the possibility that BIAR can support higher gradients by characterizing the breakdown in a high-power test. The peak gradient reached 190 MV / m when the structure was powered by 6 ns long rf pulses with 115 MW peak power. The short rf pulses were extracted from 65 MeV electron bunch trains with a total charge of up to 210 nC. This work has revealed the benefits of short-pulse acceleration by characterizing rf breakdown in the previously unexplored parameter space. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Observation and study of the baryonic B-meson decays B→D (*) pp̄(π)(π)

We present results for B-meson decay modes involving a charm meson, protons, and pions using 455×10⁶ BB¯¯¯ pairs recorded by the BaBar detector at the SLAC PEP-II asymmetric-energy e⁺e⁻ collider. The branching fractions are measured for the following ten decays: B¯¯¯⁰→D⁰pp̄, B¯¯¯⁰→D*⁰pp̄, B¯¯¯⁰→D⁺pp̄π⁻, B¯¯¯⁰→D*⁺pp̄π⁻, B⁻→D⁰pp̄π⁻, B⁻→D*⁰pp̄π⁻, B¯¯¯⁰→D⁰pp̄π⁻π⁺, B¯¯¯⁰→D*⁰pp̄π⁻π⁺, B⁻→D⁺pp̄π⁻π⁻, and B⁻→D*⁺pp̄π⁻π⁻. The four B⁻ and the two five-body B¯¯¯⁰ modes are observed for the first time. The four-body modes are enhanced compared to the three- and the five-body modes. In the three-body modes, the M(pp̄) and M(D(*)⁰p) invariant-mass distributions show enhancements near threshold values. In the four-body mode B¯¯¯⁰→D⁺pp̄π⁻, the M(pπ⁻) distribution shows a narrow structure of unknown origin near 1.5 GeV/c². The distributions for the five-body modes, in contrast to the others, are similar to the expectations from uniform phase-space predictions.

del Amo Sanchez, P.↗

SU-E-P-30: Clinical Applications of Spatially Fractionated Radiation Therapy (GRID) Using Helical Tomotherapy

Purpose: To present the first clinical applications of Helical Tomotherapy-based spatially fractionated radiotherapy (HT-GRID) for deep seated tumors and associated dosimetric study. Methods: Ten previously treated GRID patients were selected (5 HT-GRID and 5 LINAC-GRID using a commercially available GRID block). Each case was re-planned either in HT-GRID or LINAC-GRID for a total of 10 plans for both techniques using same prescribed dose of 20 Gy to maximum point dose of GRID GTV. For TOMO-GRID, a programmable virtual TOMOGRID template mimicking a GRID pattern was generated. Dosimetric parameters compared included: GRID GTV mean dose (Dmean) and equivalent uniform dose (EUD), GRID GTV dose inhomogeneity (Ratio(valley/peak)), normal tissue Dmean and EUD, and other organs-at-risk(OARs) doses. Results: The median tumor volume was 634 cc, ranging from 182 to 4646 cc. Median distance from skin to the deepest part of tumor was 22cm, ranging from 8.9 to 38cm. The median GRID GTV Dmean and EUD was 10.65Gy (9.8–12.5Gy) and 7.62Gy (4.31–11.06Gy) for HT-GRID and was 6.73Gy (4.44–8.44Gy) and 3.95Gy (0.14–4.2Gy) for LINAC-GRID. The median Ratio(valley/peak) was 0.144(0.05–0.29) for HT-GRID and was 0.055(0.0001–0.14) for LINAC-GRID. For normal tissue in HT-GRID, the median Dmean and EUD was 1.24Gy (0.34–2.54Gy) and 5.45 Gy(3.45–6.89Gy) and was 0.61 Gy(0.11–1.52Gy) and 6Gy(4.45–6.82Gy) for LINAC-GRID. The OAR doses were comparable between the HT-GRID and LINAC-GRID. However, in some cases it was not possible to avoid a critical structure in LINAC-GRID; while HT-GRID can spare more tissue doses for certain critical structures. Conclusion: HT-GRID delivers higher GRID GTV Dmean, EUD and Ratio(valley/peak) compared to LINAC-GRID. HT-GRID delivers higher Dmean and lower EUD for normal tissue compared to LINAC-GRID. TOMOGRID template can be highly patient-specific and allows adjustment of the GRID pattern to different tumor sizes and shapes when they are deeply-seated and cannot be safely treated with LINAC-GRID.

60 APPLIED LIFE SCIENCES↗

Development of an Extreme Environment Materials Research Facility at Princeton

The need for a fundamental understanding of material response to a neutron and/or high heat flux environment can yield development of improved materials and operations with existing materials. Such understanding has numerous applications in fields such as nuclear power (for the current fleet and future fission and fusion reactors), aerospace, and other research fields (e.g., high-intensity proton accelerator facilities for high energy physics research). A proposal has been advanced to develop a facility for testing various materials under extreme heat and neutron exposure conditions at Princeton. The Extreme Environment Materials Research Facility comprises an environmentally controlled chamber (48 m^3) capable of high vacuum conditions, with extreme flux beams and probe beams accessing a central, large volume target. The facility will have the capability to expose large surface areas (1 m^2) to 14 MeV neutrons at a fluence in excess of 10^13 n/s. Depending on the operating mode. Additionally beam line power on the order of 15-75 MW/m2 for durations of 1-15 seconds are planned... The multi-second duration of exposure can be repeated every 2-10 minutes for periods of 10-12 hours. The facility will be housed in the test cell that held the Tokamak Fusion Test Reactor (TFTR), which has the desired radiation and safety controls as well as the necessary loading and assembly infrastructure. The facility will allow testing of various materials to their physical limit of thermal endurance and allow for exploring the interplay between radiation-induced embrittlement, swelling and deformation of materials, and the fatigue and fracturing that occur in response to thermal shocks. The combination of high neutron energies and intense fluences will enable accelerated time scale studies. The results will make contributions for refining predictive failure modes (modeling) in extreme environments, as well as providing a technical platform for the development of new alloys, new materials, and the investigation of repair mechanisms. Effects on materials will be analyzed with in situ beam probes and instrumentation as the target is exposed to radiation, thermal fluxes and other stresses. Photon and monochromatic neutron fluxes, produced using a variable-energy (4-45 MeV) electron linac and the highly asymmetric electron-positron collisions technique used in high-energy physics research, can provide non-destructive, deep-penetrating structural analysis of materials while they are undergoing testing. The same beam lines will also be able to generate neutrons from photonuclear interactions using existing Bremsstrahlung and positrons on target quasi-monochromatic gamma rays. Other diagnostics will include infrared cameras, residual gas analyzer (RGA), and thermocouples; additional diagnostic capability will be added.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗