Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Implementation of Maxwell's equations in the reconstruction of the magnetic field in the g -2 storage ring

We present a method for implementing the constraints that are implied by Maxwell's equations in fits to measurements of the magnetic field in the muon storage ring of the $g - 2$ experiment. The method that we use makes use of toroidal-harmonic solutions of Laplace's equation. We point out that the fitting problem can be approximated well as a linear-algebra problem. We have devised an efficient algorithm for the linear-algebra problem that makes it possible to find a solution for 10 5 data points and 10 4 harmonics in less than an hour on a present-day desktop computer. We illustrate our method by applying it to some preliminary measurements of the magnetic field in the $g - 2$ storage ring.

43 PARTICLE ACCELERATORS↗

Multi-Core Microcontroller Hardware In the Loop System for Electric Machine Control

Hardware in the Loop (HIL) is a simulation technique used to reduce the software development cycle and test control systems in a non-destructive environment. This work describes a cost effective HIL simulator on a dual core microcontroller in which one core acts as a controller and the other emulates the system under control. The emulator runs one step per Pulse Width Modulation (PWM) period in real time. To handle the computational burden and prioritize execution of simulation and control tasks, an interrupt-based software architecture with task prioritization has been developed. As a demonstration, the HIL has been implemented on a Texas Instruments TMS320F28379D dual core microcontroller, which emulates a Permanent Magnet Synchronous Machine (PMSM) with resolver feedback. Hardware peripherals are developed and tested concurrently with the control system, providing higher confidence in the software. By using the peripherals in the HIL development, the controller exercises either the HIL emulation or a pin compatible PMSM testbench. To quantify performance and validate the processor based emulator, the HIL results are compared to the preexisting testbench for accuracy benchmarking at no-load and under load for a range of operating points.

33 ADVANCED PROPULSION SYSTEMS↗

A Large Bore Conduction Cooled Superconducting Magnet for the Princeton Axion Search

Princeton University (PU) is designing and building a new experiment, called the Princeton Axion Search (PXS), that aims to discover (or exclude) Quantum Chromodynamics (QCD) axions in the 0.8–2 μeV mass range that are the cosmological dark matter. Core elements of the experiment are new, and in particular new to the search for axion dark matter. An essential component of the experiment is a 5 T superconducting magnet with a total bore volume of ~500 L. The Princeton Plasma Physics Laboratory (PPPL), a Department of Energy (DOE) Laboratory managed by Princeton University, has the unique expertise and experimental facilities to design and construct such a solenoid magnet assembled with the cavity resonator for PXS. To support this, PPPL utilizes legacy ITER-Nb3Sn conductors, along with its experimental facilities and expertises to design, build and test low-cost conduction-cooled superconducting solenoid magnets to be integrated into the axion detector. This paper discusses the various coil design and integration challenges in the large bore conduction cooled magnet in support of PXS. In conclusion, the proposed instrumental methods will help optimize the path to future and more ambitious axion searches at lower masses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Proton Radiography for the Diagnostics of a Dense Plasma

The possibility of using high-energy proton radiography for dense plasma diagnostics is discussed. The designed telescopic ion optical system for a proton radiography installation with a 1 GeV beam is presented. The schematic diagram of the proton microscope is given. It is shown that the estimate of spatial resolution for the installation obtained with consideration of chromatic aberrations of magnetic quadrupole lenses is limited from below.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication and testing of high-performance all-metal neutron guides and axisymmetric mirrors by electrochemical replication

Neutron scattering is one of the most useful methods of studying the structure of matter, with applications to biomedical, structural, magnetic and energy-related materials. Neutron-scattering instruments are installed around research reactors or accelerator-based neutron sources, and neutron guides are critical components of these facilities. They are neutron-transport optical devices consisting of state-of-the-art mirrors often tens of meters long. Here we demonstrate a novel fabrication method of all-metallic neutron guides and axisymmetric mirrors by electroplating from precision mandrels. The process allows for the fabrication of single-piece all-metal guides of prismatic and axisymmetric shapes. We also demonstrate supermirror guides and axisymmetric focusing supermirrors produced with the same technology. We present the fabrication and tests of the multilayer-coated replicated guides and optic and show that the mandrel is reproduced with high fidelity and reliability. Furthermore, such supermirror optics will provide game-changing improvements in neutron techniques.

36 MATERIALS SCIENCE↗

2022 American Conference on Neutron Scattering (ACNS 2022)

The 11th American Conference on Neutron Scattering (ACNS 2022) will be held on June 5-9, 2022, in Boulder, CO. The Conference will provide essential information on the breadth and depth of current neutron-related research worldwide. Hosted by the Neutron Scattering Society of America, this year’s Conference will feature a combination of invited and contributed talks, poster sessions, and tutorials. Topics of the conference are: Advances in Neutron Facilities, Instrumentation and Software: Developments in sources, instrumentation, sample environments and control software. Hard Condensed Matter: Magnetism, correlated metals, quantum/topological materials, superconductors, ferroelectrics, multiferroics, glasses, and disorder phenomena. Submissions outlining examples of neutron scattering in industrial and engineering applications involving hard condensed matter systems are also encouraged. Soft Matter: Neutron studies of soft materials and related fields including in situ and in operando studies. Polymers, surfactants, emulsions, gels, nanoparticles, colloidal suspensions and more. Submissions of computational studies or applications of machine learning beneficial to neutron scattering experiments, as well as examples of neutron scattering in industrial and engineering applications are strongly encouraged. Biology, Biophysics and Biotechnology: Neutron studies of biological and biologically relevant systems. Proteins, bio membranes, biological assemblies, natural materials, nucleic acids, drug-delivery platforms and biomedical systems. Submissions of computational studies or applications of machine learning beneficial to biological neutron scattering experiments, as well as examples of neutron scattering in applied research involving biological systems, are strongly encouraged. Materials Chemistry and Energy: Neutron-based studies of functional materials and materials for energy applications. Examples include porous materials such as metal organic frameworks (MOFs), zeolites; phosphors; novel pigments; electrolytes; catalysts; ionic conductors/cathode materials; photovoltaic materials (hybrid perovskites); thermoelectrics; magnetocalorics/electrocalorics. Structural Materials and Engineering: Neutron scattering studies of materials and engineering processes including structural materials, concrete and metals, as well as engineering processes including combustion, corrosion, additive manufacturing, and others. Neutron Physics: Fundamental physical studies of the neutron and related areas. Emerging Applications in Neutron Scattering: Machine Learning and Data Science: Advances in computing power have contributed to rapidly evolving machine learning and data science fields that can be leveraged to the benefit of the neutron scattering community. The purpose of this session is to highlight recent advances in machine learning and data science and to serve as the foundation of a parallel data and computation track highlighting computation advances and applications in neutron scattering throughout the conference.

36 MATERIALS SCIENCE↗

Nuclear Magnetic Resonance Relaxation Pathways in Electrolytes for Energy Storage

Nuclear Magnetic Resonance (NMR) spin relaxation times have been an instrumental tool in deciphering the local environment of ionic species, the various interactions they engender and the effect of these interactions on their dynamics in conducting media. Of particular importance has been their application in studying the wide range of electrolytes for energy storage, on which this review is based. Here we highlight some of the research carried out on electrolytes in recent years using NMR relaxometry techniques. Specifically, we highlight studies on liquid electrolytes, such as ionic liquids and organic solvents; on semi-solid-state electrolytes, such as ionogels and polymer gels; and on solid electrolytes such as glasses, glass ceramics and polymers. Although this review focuses on a small selection of materials, we believe they demonstrate the breadth of application and the invaluable nature of NMR relaxometry.

25 ENERGY STORAGE↗

PLASMA ENVIRONMENT AROUND COMET 67P/CHURYUMOV–GERASIMENKO AT PERIHELION: MODEL COMPARISON WITH ROSETTA DATA

The plasma environment near comet 67P/Churyumov–Gerasimenko (67P/CG) is dynamically affected by various factors, including the incident solar wind and outgassing from the nucleus. The Rosetta spacecraft MAGnetometer (MAG) instrument observations near perihelion showed crossing events into a magnetic field-free region at about 170 km from the nucleus in 2015 July at 1.26 au from the Sun. At each crossing, the magnitude of the magnetic field dropped by more than 20 nT to near zero. We compared the Ion and Electron Sensor (IES) electron differential flux energy spectrum inside and outside the crossing boundaries. The IES observations show a modest but consistent drop in electron flux for energies between 40 eV and a few hundred eV at each cavity crossing event. This drop in the electron spectra might be due to the absence or attenuation of solar wind electrons inside the observed diamagnetic regions, which might or might not be a diamagnetic cavity. There is no apparent simple linear correlation between the electron count rate measured by the IES at different energies and the magnitude of the magnetic field, however; at all energies, the highest electron count rates are recorded at the highest magnetic field magnitudes. From model-data comparisons it seems that inside diamagnetic regions, pure coma photoelectrons are not sufficient to explain the observations and that a trapping mechanism and/or infused solar wind electrons are necessary to explain the observed electron fluxes.

79 ASTRONOMY AND ASTROPHYSICS↗

A high-resolution Fourier Transform Spectrometer for planetary spectroscopy

The employment of a high-resolution Fourier Transform Spectrometer (FTS) is described for planetary and other astronomical spectroscopy in conjunction with the 88-inch telescope at Mauna Kea Observatory. The FTS system is designed for a broad range of uses, including double-beam laboratory spectroscopy, infrared gas chromatography, and nuclear magnetic resonance spectroscopy. The data system is well-suited to astronomical applications because of its great speed in acquiring and transforming data, and because of the enormous storage capability of the magnetic tape unit supplied with the system. The basic instrument is outlined 2nd some of the initial results from the first attempted use on the Mauna Kea 88-inch telescope are reported.

Cruikshank, D. P.↗

Simulation, guidance and navigation of the B-737 for rollout and turnoff using MLS measurements

A simulation program is described for the B-737 aircraft in landing approach, a touchdown, rollout and turnoff for normal and CAT III weather conditions. Preliminary results indicate that microwave landing systems can be used in place of instrument landing systems landing aids and that a single magnetic cable can be used for automated rollout and turnoff. Recommendations are made for further refinement of the model and additional testing to finalize a set of guidance laws for rollout and turnoff.

Pines, S.↗

Correlated observations of several auroral substorms on February 17, 1971

The purpose of this study is to correlate in detail auroral activity with the corresponding disturbances in the magnetotail. The auroral data were recorded by optical instruments aboard an airplane flying over the Arctic Ocean along the Alaska meridian and by the Alaska meridian chain of all-sky cameras. The corresponding magnetotail observations were made by various instruments on Vela 6A and Imp 5; the interplanetary magnetic field was monitored concurrently by Explorer 35. Three successive substorms were observed on February 17, 1971. Each substorm was readily identified by the classical auroral and magnetic signatures which accompanied its onset. The observed variations of plasma and magnetic field in the magnetotail were consistent with the idea that a neutral line formed in the range X sub SM between -12 and -18 R sub E at the onset of each substorm expansive phase and then moved tailward past X sub SM = -18 R sub E some tens of minutes afterward. The Z component of the tail magnetic field decreased rather steadily for a period of 1-2 1/2 hours after each substorm and until the onset of the next expansive phase, reaching a minimum value just before each onset.

Hones, E. W., Jr.↗

A vector autopilot system

Current technology has evolved low cost, highly reliable solid state vector magnetometers with excellent angular resolution. This paper discusses the role of a three-axis magnetometer as a new instrument for aircraft attitude determination. Using flight data acquired by an instrumented aircraft, attitude is calculated using the earth's magnetic field vector and compared to measured attitudes. The magnetic field alone is not adequate to resolve all attitude variations and the need for a second reference angle or vector is discussed. A system combining the functions of heading determination and attitude measurement is presented to show that both functions can be implemented with essentially the same component count required to measure heading alone. It is concluded that with the correlation achieved in calculated and measured attitude there is a potential application of vector magnetometry in attitude measurement systems.

Pietila, R.↗

News conference on Voyager-2-Jupiter encounter

The proceedings of a news conference on the Voyager 2 Jupiter project are presented. Topics include the instrumentation on the Voyager 2, Jupiter's atmosphere and magnetic field, the Jupiter moons, and the observations of lightning on Jupiter.

Source record↗

Space Processing Applications Rocket (SPAR) project, SPAR 9

SPAR 9 (R-17) payload configuration, rocket performance, payload support, science payload instrumentation, and payload recovery are discussed. Directional solidification of magnetic composites, directional solidification of immiscible aluminum-indium alloys, and comparative alloy solidification experiments are reported.

Poorman, R.↗

Gamma-radiation with E gamma 5 MeV detected from Seyfert galaxy 3C120 and region with 1" = 190 deg and b" = 20 deg

The observation of the Galaxy anticenter region in gamma-rays with E gamma = 5 / 100 MeV was made by gamma-telescope Natalya-1 in a balloon flight. The flight was performed at the ceiling 5.1 + or - 0.1 g/sq cm, magnetic cutoff being 17 GV. The description of the instrument and the analysis of the experiment conditions are given. The tracks of electron-positron pairs generated by gamma-quanta in the convertors were detected by wire spark chambers. The recorded events were classified manually by an operator using a graphic display into three classes: pairs, single and bad events. The arrival angle of gamma-quanta and their energy for selected gamma-ray events (pairs and singles) were determined through multiple scattering of pair components in the convertors. On the basis of the data obtained the celestial maps were made in gamma-rays for E sub gamma 5 MeV and E gamma 20 MeV energy ranges.

Damle, S. V.↗

Geophysical remote sensing

The types of remote sensing images which have applications in geophysical studies are reviewed. Features of the Shuttle Imaging Radar, a synthetic aperture radar, are described and a sample image is provided to illustrate the capabilities for mapping large-scale geological structure. A combined Landsat-Seasat image is shown to yield data on crustal composition. Sea surface topographic features that result from gravitational effects are demonstrated to be amenable to characterization with another Seasat instrument, a radar altimeter. Magsat data allow identification of magnetic perturbations produced by crustal magnetization. Finally, auroral imagery gathered with the Atmospheric Dynamics Explorer are presented which show that the effects of particles bombarding the atmosphere can be detected at UV wavelengths.

Mcpherron, Robert L.↗

Spatial scale of the substorm onset region determined from multi-point satellite and ground-based observations

The temporal and spatial scale of the onset of two substorm events is investigated using high resolution energetic particle and magnetic field data at synchronous orbit plus auroral and magnetic field data simultaneously taken from the ground based instrumentation. During both intervals the major expansion onset had precursor localized expansions without significant negative bay enhancement ('pseudobreakups'). Typical magnetospheric onset signatures such as tail current diversion, dipolarization, and injection were observed associated with some of the pseudobreakups. The major expansion, on the other hand, consisted of a number of rather localized injections and expansions, each of which had times scales of 5 to approximately 10 minutes, a comparable time scale to that of pseudobreakups. The number of occurrences, as well as the scale size of the magnetospheric source region, would constitute the major difference between pseudobreakup and the global expansion onset.

Nakamura, Rumi↗

Particle and field signatures during pseudobreakup and major expansion onset

The temporal and spatial scales of the onset of two types of substorm events are investigated. These substorms were cases where the expansion onset had precursor localized auroral activation without significant negative bay enhancement, that is, 'pseudobreakup'. High-resolution energetic particle and magnetic field data at synchronous orbit are used for the analysis together with auroral and magnetic field data simultaneously taken from ground-based instrumentation. The auroral structure following the pseudobreakup significantly resembled the major expansion aurora, except in its spatial scale. Typical magnetospheric onset signatures such as tail current diversion, dipolarization, and injection were observed associated with some of the pseudobreakups. The major expansion, on the other hand, consisted of a number of rather localized injections and expansions, each of which had timescales of 2-8 min, a comparable timescale to that of pseudobreakups. This study shows that there does not appear to be any phenomenological differences between pseudobreakups and major expansion onsets. The major difference between pseudobreakups and major expansion onsets would be the number of occurrences, as well as the intensity and the scale size of the magnetospheric source.

Nakamura, Rumi↗