Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Resonant magnetic fields from inflation

We propose a novel scenario to generate primordial magnetic fields during inflation induced by an oscillating coupling of the electromagnetic field to the inflaton. This resonant mechanism has two key advantages over previous proposals. First of all, it generates a narrow band of magnetic fields at any required wavelength, thereby allaying the usual problem of a strongly blue spectrum and its associated backreaction. Secondly, it avoids the need for a strong coupling as the coupling is oscillating rather than growing or decaying exponentially. Despite these major advantages, we find that the backreaction is still far too large during inflation if the generated magnetic fields are required to have a strength of O(10{sup −15} Gauss) today on observationally interesting scales. We provide a more general no-go argument, proving that this problem will apply to any model in which the magnetic fields are generated on subhorizon scales and freeze after horizon crossing.

79 ASTRONOMY AND ASTROPHYSICS↗

Novel motor design for rotating anode x-ray tubes operating in the fringe field of a magnetic resonance imaging system

Purpose: Using hybrid x-ray/MR (XMR) systems for image guidance during interventional procedures could enhance the diagnosis and treatment of neurologic, oncologic, cardiovascular, and other disorders. The authors propose a close proximity hybrid system design in which a C-arm fluoroscopy unit is placed immediately adjacent to the solenoid magnet of a MR system with a minimum distance of 1.2 m between the x-ray and MR imaging fields of view. Existing rotating anode x-ray tube designs fail within MR fringe field environments because the magnetic fields alter the electron trajectories in the x-ray tube and act as a brake on the induction motor, reducing the rotation speed of the anode. In this study the authors propose a novel motor design that avoids the anode rotation speed reduction. Methods: The proposed design replaces the permanent magnet stator found in brushed dc motors with the radial component of the MR fringe field. The x-ray tube is oriented such that the radial component of the MR fringe field is orthogonal to the cathode-anode axis. Using a feedback position sensor and the support bearings as electrical slip rings, the authors use electrical commutation to eliminate the need for mechanical brushes and commutators. A vacuum compatible prototype of the proposed motor design was assembled, and its performance was evaluated at various operating conditions. The prototype consisted of a 3.1 in. diameter anode rated at 300 kHU with a ceramic rotor that was 5.6 in. in length and had a 2.9 in. diameter. The material chosen for all ceramic components was MACOR, a machineable glass ceramic developed by Corning Inc. The approximate weight of the entire assembly was 1750 g. The maximum rotation speed, angular acceleration, and acceleration time of the motor design were investigated, as well as the dependence of these parameters on rotor angular offset, magnetic field strength, and field orientation. The resonance properties of the authors' assembly were also evaluated to determine its stability during acceleration, and a pulse width modulation algorithm was implemented to control the rotation speed of the motor. Results: At a magnetic flux density of 41 mT orthogonal to the axis of rotation (on the lower end of the expected flux density in the MR suite) the maximum speed of the motor was found to be 5150 revolutions per minute (rpm). The acceleration time necessary to reach 3000 rpm was found to be approximately 10 s at 59 mT. The resonance frequency of the assembly with the anode attached was 1310 rpm (21.8 Hz) which is far below the desired operating speeds. Pulse width modulation provides an effective method to control the speed of the motor with a resolution of 100 rpm. Conclusions: The proposed design can serve as a direct replacement to the conventional induction motor used in rotating anode x-ray tubes. It does not suffer from a reduced rotation speed when operating in a MR environment. The presence of chromic steel bearings in the prototype prevented testing at the higher field strengths, and future iterations of the design could eliminate this shortcoming. The prototype assembly demonstrates proof of concept of the authors' design and overcomes one of the major obstacles for a MR compatible rotating anode x-ray tube.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in the Understanding of ELM Suppression by Resonant Magnetic Perturbations (RMPs) in DIII-D and Implications for ITER

Experiments on DIII-D have expanding the operating window for RMP ELM suppression to higher q95 with dominant electron heating and fully non-inductive current drive relevant to advanced modes of ITER operation. Robust ELM suppression has also been obtained with a reduced coil set, mitigating the risk of coil failure in maintaining ELM suppression in ITER. These results significantly expand the operating space and reduce risk for obtaining RMP ELM suppression in ITER. Efforts have also been made to search for 3D cause of ELM suppression. No internal non-axisymmetric structure is detected at the top of the pedestal, indicating that the dominant effect of the RMP is to produce an n=0 transport modification of the profiles. Linear two fluid MHD simulations using M3D-C1 indicate resonant field penetration and significant magnetic stochasticity at the top of the pedestal, consistent with the absence of detectable 3D structure in that region. A profile database was developed to compare the scaling of the pedestal and global confinement with the applied 3D field strength in ELM suppressed and ELM mitigated plasmas. The EPED pedestal model accurately predicts the measured pedestal pressure at the threshold of ELM suppression, increasing confidence in theoretical projections to ITER pedestal conditions. Both the H-factor (H(sub)98y2) and thermal energy confinement time do not degrade substantially with applied RMP fields near the threshold of ELM suppression, enhancing confidence in the compatibility of ITER high performance operation with RMP ELM suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward Ultra‐High‐Quality‐Factor Wireless Masing Magnetic Resonance Sensing

It has recently been shown that a bolus of hyperpolarized nuclear spins can yield stimulated emission signals similar in nature to maser signals, potentially enabling new ways of sensing hyperpolarized contrast media, including most notably [1- 13 C]pyruvate that is under evaluation in over 50 clinical trials for metabolic imaging of cancer. The stimulated NMR signal emissions lasting for minutes do not require radio-frequency excitation, offering unprecedented advantages compared to conventional MR sensing. However, creating nuclear spin maser emission is challenging in practice due to stringent fundamental requirements, making practical in vivo applications hardly possible using conventional passive MR detectors. Here, in this study, we demonstrate the utility of a wireless NMR maser detector, the quality factor of which was enhanced 22-fold (to 1,670) via parametric pumping. This active-feedback technique breaks the intrinsic fundamental limit of NMR detector circuit quality factor. We show the use of parametric pumping to reduce the threshold requirement for inducing nuclear spin masing at 300 MHz resonance frequency in a preclinical MRI scanner. Indeed, stimulated emission from hyperpolarized protons was obtained under highly unfavorable conditions of low magnetic field homogeneity (T 2 * of 3 ms). Greater gains of the quality factor of the MR detector (up to 1 million) were also demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-G-17A-04: Measurements of the Electron-Return-Effect in a Commercial Magnetic Resonance Image Guided Radiation Therapy (MR-IGRT) System

Purpose: The aim of this work was to measure the influences of the Lorentz force (electron return effect) on secondary electron transport in the presence of a low magnetic field produced in a commercial MR-IGRT system using a custom heterogeneous phantom. Methods: A commercial MR-IGRT system has been commissioned in our department. The system combines real-time imaging using a split-bore 0.35-T MRI and three Co-60 heads, each collimated with a doubly-focused MLC. The integrated treatment planning system uses a Monte-Carlo algorithm that models the magnetic field effects on scattered electrons. During commissioning, a custom heterogeneity phantom was designed to acquire ionization chamber and film measurements. The 30 cm cubic phantom consists of two waterfilled annuli, each containing a central region that simulates a 6 cm cubic lung tumor using polystyrene embedded in cork. Film may be placed inbetween the halves, and small-volume ionization chambers may be placed in different positions to measure dose to the tumor and near interfaces where the electron return effect is expected. The treatment planning system was used to create open-field and IMRT treatment plans on a CT scan of the phantom. Plans were delivered to the phantom, and radiographic film and ionization chamber measurements were obtained. Results: The mean ionization chamber measured dose ratio for 27 measurements for 5 plans was 0.993 ± 0.027. Lateral profile film measurements confirm that the electron-return-effect is observable, producing local dose variations of less than 10% over 5 mm with 0.35 T magnetic field for single field treatment plans. The effect becomes negligible for opposing-field and IMRT treatments. Conclusion: A heterogeneous phantom for measurement of the electron-return-effect has been designed. Ionization chamber and film measurements made with the phantom indicate that the dosimetric effect is minimal, and the treatment planning system predicts dose reasonably well for complex heterogeneous scenarios.

60 APPLIED LIFE SCIENCES↗

Markov Chain Monte Carlo Used in Parameter Inference of Magnetic Resonance Spectra

In this paper, we use Boltzmann statistics and the maximum likelihood distribution derived from Bayes’ Theorem to infer parameter values for a Pake Doublet Spectrum, a lineshape of historical significance and contemporary relevance for determining distances between interacting magnetic dipoles. A Metropolis Hastings Markov Chain Monte Carlo algorithm is implemented and designed to find the optimum parameter set and to estimate parameter uncertainties. In conclusion, the posterior distribution allows us to define a metric on parameter space that induces a geometry with negative curvature that affects the parameter uncertainty estimates, particularly for spectra with low signal to noise.

43 PARTICLE ACCELERATORS↗

Effects of strain and quantum confinement in optically pumped nuclear magnetic resonance in GaAs: Interpretation guided by spin-dependent band structure calculations

A combined experimental-theoretical study of optically pumped NMR (OPNMR) has been performed in a GaAs/Al 0.1 Ga 0.9 As quantum well film with thermally induced biaxial strain. The photon energy dependence of the Ga-71 OPNMR signal was recorded at magnetic fields of 4.9 and 9.4 T at a temperature of 4.8-5.4 K. The data were compared to the nuclear spin polarization calculated from differential absorption to spin-up and spin-down states of the conduction band using a modified Pidgeon Brown model. Reasonable agreement between theory and experiment is obtained, facilitating assignment of features in the OPNMR energy dependence to specific interband transitions. Despite the approximations made in the quantum-mechanical model and the inexact correspondence between the experimental and calculated observables, the results provide insight into how effects of strain and quantum confinement are manifested in OPNMR signals

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detection of magnetic resonance signals using a magnetoresistive sensor

A method and apparatus are described wherein a micro sample of a fluidic material may be assayed without sample contamination using NMR techniques, in combination with magnetoresistive sensors. The fluidic material to be assayed is first subject to pre-polarization, in one embodiment, by passage through a magnetic field. The magnetization of the fluidic material is then subject to an encoding process, in one embodiment an rf-induced inversion by passage through an adiabatic fast-passage module. Thereafter, the changes in magnetization are detected by a pair of solid-state magnetoresistive sensors arranged in gradiometer mode. Miniaturization is afforded by the close spacing of the various modules.

47 OTHER INSTRUMENTATION↗

SU-E-T-136: Dosimetric Robustness of a Magnetic Resonance Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the radiation delivery robustness of the first MR-IGRT system using a commercial cylindrical diode array detector (ArcCHECK) and an ionization thimble chamber (Exradin A18). Methods: The MR-IGRT system is composed of three evenly spaced Co-60 sources on a rotating gantry located between two magnet halves. The collimator for each source consists of 30 doubly-focused leaf pairs that allow the system to deliver both conformal and intensity modulated (IMRT) treatment plans. The system's delivery robustness was tested over a span of 6 months from September 2013 through February 2014. This was achieved by repeatedly delivering 10 patient plans. These plans consisted of 2 conformal prostates, 2 IMRT prostates, 2 IMRT head and neck, 2 IMRT breast, 1 IMRT pancreas, and 1 IMRT bladder. The plans were generated with the system's treatment planning software. Once the plans were generated, quality assurance plans were created on a digital ArcCHECK dataset. The ArcCHECK used for testing was specially designed to be MR-compatible by moving the power supply outside of the magnetic field. The A18 ionization chamber was placed in a custom plastic plug insert in the center of the ArcCHECK. Gamma analysis was used with the ArcCHECK for relative dose evaluating both 3%/3mm and 2%/2mm. Absolute point dose was compared between ion chamber measurement and treatment plan. Results: The ArcCHECK passing rate remained constant over the 6 month period. The average passing rate for 3%/3mm and 2%/2mm analysis was 98.6% ± 0.7 and 88.8% ± 2.9, respectively. The ion chamber measurements showed little variation with an average percent difference between planned dose verses measured dose of 0.9% ± 0.7. Conclusion: Minimal differences were noted in the delivery of the 10 patient plans. Over a period that included acceptance testing, commissioning, and clinical deliveries, the MR-IGRT system remained consistent in radiation delivery.

60 APPLIED LIFE SCIENCES↗

X-ray resonant magnetic scattering and x-ray magnetic circular dichroism branching ratios, L[subscript 3] / L[subscript 2], for heavy rare earths

In this study we have used first principles electronic structure methods to investigate the detailed contributions to the L{sub 3}/L{sub 2} branching ratio in the heavy rare earth elements. The calculations use the full potential, relativistic, linear augmented plane wave method with the LSDA+U approach for consideration of the local 4f electronic orbitals. With no spin orbit coupling (SOC) in the conducting bands, and with the same radial function for the 2p{sub 3/2} and 2p{sub 1/2} core states, the branching ratio (BR) is exactly 1:-1 for the x-ray magnetic circular dichroism spectra of the ferromagnetic heavy rare earth metals. However, with full SOC the BR ranges from 1.5 to 6.0 in going from Gd to Er. The energy and spin dependence of the 5d radial functions are important. The results point to problems with modified atomic models which have been proposed to explain the BR. Recent x-ray resonant magentic scattering experiments on (Gd,Tb,Dy,Ho,Er,Tm)Ni{sub 2}Ge{sub 2} are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cu nuclear magnetic resonance study of charge and spin stripe order in La 1.875 Ba 0.125 CuO 4

In this paper, we present a Cu nuclear magnetic/quadrupole resonance study of the charge stripe ordered phase of LBCO, with detection of previously unobserved (“wiped-out”) signal. We show that spin-spin and spin-lattice relaxation rates are strongly enhanced in the charge ordered phase, explaining the apparent signal decrease in earlier investigations. The enhancement is caused by magnetic, rather than charge fluctuations, conclusively confirming the long-suspected assumption that spin fluctuations are responsible for the wipeout effect. Observation of the full Cu signal enables insight into the spin and charge dynamics of the stripe-ordered phase, and measurements in external magnetic fields provide information on the nature and suppression of spin fluctuations associated with charge order. Lastly, we find glassy spin dynamics, in agreement with previous work, and incommensurate static charge order with charge modulation amplitude similar to other cuprate compounds, suggesting that the amplitude of charge stripes is universal in the cuprates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation study of fast ion losses associated with the rotating n = 1 resonant magnetic perturbations in KSTAR

In this work we describe a simulation framework for testing the fast ion loss mechanism associated with the experimentally observed beam ion losses when an externally applied toroidally rotating perturbed magnetic field is used to control edge localized modes in the KSTAR tokamak. The simulations reproduce the key qualitative features of neutral beam injection (NBI) ion detection by a fast ion loss detector. The NBI ion losses in the simulation mainly occur for passing particles due to orbit stochastization, which is caused by orbit resonance with the 3D field perturbations. The relative toroidal angle of NBI ion deposition to the orbit island determines the radial path of the particles between confinement or loss. The fast ion loss quantity depends on the toroidal angle rotation of the 3D field with respect to the beam deposition position. The averaged transport of toroidal canonical angular momentum reveals that linear and nonlinear resonance of the NBI ions within the 3D field are the main factors determining fast ion transport and loss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Delivering Robust Proton-Only Sensing of Hyperpolarized [1,2- 13 C 2 ]-Pyruvate Using Broad-Spectral-Range Nuclear Magnetic Resonance Pulse Sequences

Hyperpolarized [1- 13 C]pyruvate is the leading hyperpolarized injectable contrast agent and is currently under evaluation in clinical trials for molecular imaging of metabolic diseases, including cardiovascular disease and cancer. One aspect limiting broad scalability of the technique is that hyperpolarized 13 C MRI requires specialized 13 C hardware and software that are not generally available on clinical MRI scanners, which employ proton-only detection. Here, we present an approach that uses pulse sequences to transfer 13 C hyperpolarization to methyl protons for detection of the 13 C– 13 C pyruvate singlet, employing proton-only excitation and detection only. The new pulse sequences are robust to the B 1 and B 0 magnetic field inhomogeneities. The work focuses on singlet-to-magnetization (S2M) and rotor-synchronized (R) pulses, both relying on trains of hard pulses with broad spectral width coverage designed to effectively transform hyperpolarized 13 C 2 -singlet hyperpolarization to 1 H polarization on the CH 3 group of [1,2- 13 C 2 ]pyruvate. Finally, this approach may enable a broader adoption of hyperpolarized MRI as a molecular imaging technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the Oxygen Environment in UO22+ by Solid-State O-17 Nuclear Magnetic Resonance Spectroscopy and Relativistic Density Functional Calculations

A combined theoretical and solid-state O-17 NMR study of the electronic structure of the uranyl ion UO22+ in (NH4)4UO2(CO3)3 and rutherfordine UO2CO3 is presented, the former representing a system with a hydrogen-bonding environment around the uranyl oxygens, and the latter exemplifying a uranyl environment without hydrogens. A fully relativistic ab initio treatment reveals unique features of the U-O covalent bond, including the finding of O-17 chemical shift anisotropies that are among the largest ever reported (>1200 ppm). Computational results for the oxygen electric field gradient tensor are found to be consistently larger in magnitude than experimental solid-state O-17 NMR measurements in a 7.05 T magnetic field indicate. A modified version of the Solomon theory of the two-spin echo amplitude for a spin-5/2 nucleus is developed and applied to the analysis of the O-17 echo signal of UO22+. The William R. Wiley environmental Molecular Sciences Laboratory is a US Department of Energy national scientific user facility located at Pacific Northwest National Laboratory (PNNL) in Richland, Washington. PNNL is operated by Battelle for the US Department of Energy.

Environmental Molecular Sciences Laboratory↗

Laser surface modification of medical grade alloys for reduced heating in a magnetic resonance imaging environment

Nanoscale surface modification of medical grade metallic alloys was conducted using a neodymium-doped yttrium aluminum garnet laser-based dopant diffusion technique. The objective of this approach was to minimize the induction heating by reducing the absorbed radio frequency field. Such an approach is advantageous in that the dopant is diffused into the alloy and is not susceptible to detachment or spallation as would an externally applied coating, and is expected to not deteriorate the mechanical and electrical properties of the base alloy or device. Experiments were conducted using a controlled environment laser system with the ability to control laser properties (i.e., laser power, spot size, and irradiation time) and dopant characteristics (i.e., temperature, concentration, and pressure). The reflective and transmissive properties of both the doped and untreated samples were measured in a radio frequency (63.86 MHz) magnetic field using a system comprising a high power signal generator, a localized magnetic field source and sensor, and a signal analyzer. The results indicate an increase in the reflectivity of the laser-treated samples compared to untreated samples. The effect of reflectivity on the heating of the alloys is investigated through a mathematical model incorporating Maxwell’s equations and heat conduction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlating Protein Dynamics and Catalytic Activity of a Model Hydrogenase Using Paramagnetic and Biological Nuclear Magnetic Resonance Spectroscopy

Rational catalyst design remains a significant challenge, with electronic structure, steric, and electrostatic effects known to contribute to activity. Recently, dynamics has been recognized as another factor that impacts catalysis, though identifying and predicting these effects has remained out of reach. Nickel-substituted rubredoxin (NiRd), a protein-based mimic of a hydrogenase enzyme, serves as a model catalytic system in which dynamics can be systematically investigated with respect to activity. While over 30 secondary-sphere mutants of NiRd have been shown to be catalytically active, no significant correlation was observed between the rates and catalytic overpotential or electronic structure, prompting questions about the protein-derived factors that modulate activity. Here, in this work, NMR spectroscopy was used to investigate the roles of substrate accessibility, protein dynamics, and protein stability in controlling catalysis. Significant paramagnetic effects from the nickel center (S = 1) isolate the methylene proton resonances of the metal-coordinating cysteine residues. The sensitivity of resonance positions and linewidths to local environment offers an opportunity to study dynamical molecular changes around the metal center with high resolution. Machine learning algorithms were employed to identify correlations between the catalytic activity and the paramagnetic NMR spectra. These analyses revealed spectroscopic features of specific cysteine protons that report on catalytic overpotential and increased turnover rates, which are further supported by the results obtained using high-field NMR techniques. Collectively, these studies indicate the potential for multifrequency NMR techniques to resolve key contributors to catalytic activity and highlight the importance of local and outer-sphere dynamics.

Protein Engineering↗