Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

SU-E-T-438: Frameless Cranial Stereotactic Radiosurgery Immobilization Effectiveness Evaluation

Purpose: To evaluate immobilization effectiveness of Brainlab frameless mask in cranial stereotactic radiosurgery (SRS). Methods: Two sets of setup images were collected pre-and post-treatment for 24 frameless SRS cases. The pre-treatment images were obtained after applying 2D-2D kV image-guided shifts with patients in treatment position and approved by physicians; the post-treatment images were taken immediately after treatment completion. All cases were treated on a Novalis linac with ExacTrac positioning system and Exact Couch. The two image sets were compared with the correctional shifts measured by ExacTrac 6D auto-fusion. The shift differences were considered patient motion within the frameless mask and were used to evaluate its effectiveness for immobilization. Two-tailed paired t-test was applied for significance comparison. Results: The correctional shifts (mean±STD, median) of pre-and post-treatment images were 0.33±0.27mm, 0.26mm and 0.34±0.27mm, 0.23mm (p=0.740) in lateral direction; 0.32±0.29mm, 0.22mm and 0.48±0.30mm, 0.50mm (p=0.012) in longitudinal direction; 0.31±0.22mm, 0.24mm and 0.33±0.21mm, 0.36mm (p=0.623) in vertical direction. The radial correctional shifts (mean±STD, median) of pre -and post-treatment images were 0.60±0.38mm, 0.45mm and 0.75±0.31mm, 0.66mm (p=0.033). The shift differences (mean±STD, median, maximum) were 0.35±0.28mm, 0.3mm, 1.05mm, 0.34±0.28mm, 0.3mm, 1.00mm, 0.24±0.15mm, 0.21mm, 0.60mm and 0.61±0.32mm, 0.57mm, 1.40mm in lateral, longitudinal, vertical and radial direction, respectively. Two shifts greater than 1 mm (1.06mm and 1.02mm) were acquired from post-treatment images. However, the shift differences were only 0.09 and 0.19mm for these two shifts. Two patients with shift differences greater than 1mm (1.05 and 1.04mm) were observed and didn’t coincide with those two who had post-correctional shifts greater than 1mm. Conclusion: Image-guided SRS allowed us to set up patients with sub-millimeter accuracy relative to simulation position. However, patient motion during treatment could affect treatment accuracy. Our Result shows that Brainlab frameless mask provides reasonable patient immobilization and maintains the mean post-treatment position within sub-millimeter accuracy with some borderline results observed.

60 APPLIED LIFE SCIENCES↗

SU-E-T-633: Preparation and Planning of a VMAT Multi - Arc Radiation Therapy Technique for Full Scalp Treatment

Purpose: The target volume for angiosarcoma of the scalp encompasses the entire scalp. Full scalp radiotherapy (FSRT) requires careful design of required bolus, immobilization and marking of the field before the patient CT is acquired. A VMAT multi-arc technique was designed to deliver FSRT for a patient with angiosarcoma of the scalp to a dose of 6000cGy in 25 fractions. Methods: A custom bolus helmet was fabricated from a 0.5 cm thick sheet of aquaplast material, which was molded to the patient’s head. With the bolus helmet in place the patient was then positioned supine on a H&N immobilization board. A custom vaclock bag positioned on a standard headrest and a thermoplastic mask were used to immobilize the patient. Additional bolus to cover the remaining treatment area was attached to the mask. We acquired two CT scans of the patient’s head, one in treatment position and an additional scan without the immobilization mask with wires marking the treatment area that the oncologist had delineated on the patient’s skin. The second scan was registered to the first and used to define the treatment CTV. A four-arc VMAT treatment planned using Varian-Eclipse was optimized to cover the skin with a PTV margin while sparing the brain and limiting the dose to the optic apparatus and lacrimal glands. Daily treatment setup was verified using anterior and lateral kV on-board-imaging. To verify the treated dose, TLDs were positioned on the patient’s scalp during one fraction. Results: With full dose coverage to the PTV, the mean dose to the brain was less than 24 Gy. The dose measured by the TLDs (mean difference 1%, standard deviation 4%)showed excellent agreement with the treatment planning calculation. Conclusion: FSRT delivered with a bolus helmet and a VMAT multi-arc technique can be accurately delivered with high dose uniformity and conformality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-BRA-01: Feasibility Study for Swallowing Prediction Using Pressure Sensors

Purpose: To develop a swallowing prediction system (SPS) using force sensing sensors and evaluate its feasibility. Methods: The SPS developed consists of force sensing sensor units, a thermoplastic mask, a signal transport device and a control PC installed with an in-house software. The SPS is designed to predict the pharyngeal stage of swallowing because it is known that internal organ movement occurs in pharyngeal stage. To detect prediction signal in the SPS, the force sensing sensor units were attached on both the submental muscle region and thyroid cartilage region of the thermoplastic mask. While the signal from the thyroid cartilage region informs the action of swallowing, the signal from the submental muscle region is utilized as a precursor for swallowing. Since the duration of swallowing is relatively short, using such precursor (or warning) signals for machine control is considered more beneficial. A volunteer study was conducted to evaluate the feasibility of the system. In this volunteer study, we intended to verify that the system could predict the pharyngeal stage of the swallowing. We measured time gaps between obtaining the warning signals in the SPS and starting points of the pharyngeal stage of swallowing. Results: The measured data was examined whether the time gaps were in reasonable order to be easily utilized. The mean and standard deviation values of these time gaps were 0.550 s ± 0.183 s. in 8 volunteers. Conclusion: The proposed method was able to predict the on-set of swallowing of human subjects inside the thermoplastic mask, which has never been possible with other monitoring systems such as camera-based monitoring system. With the prediction ability of swallowing incorporated into the machine control mechanism (in the future), beam delivery can be controlled to skip swallowing periods and significant dosimetric gain is expected in head & neck cancer treatments. This work was supported by the Radiation Technology R&D program (No. 2015M2A2A7038291) and by the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

SU-F-P-58: Squamous Cell and Basal Cell Carcinoma of the Skin Treated with a Freiburg Flap Applicator

Purpose: To treat squamous cell and basal cell carcinoma of the skin with the Freiburg flap applicator using a high dose rate modality of an Elekta Flexitron or MicroSelectron for radiation delivery by compensating the dose deviation resulting from the incomplete scatter environment. Methods: Patients were selected to have lesions greater than or equal to 2cm. A mask might be needed depending on special locations. The lesions on the eyelid and face presented in this research were, however, treated without a mask. Cutting the flap into a shape conformal to the target and attaching it to the mask were used in order to make the treatment reproducible. Patients were scanned with a Philips Big Bore Brilliant CT. A 1cm margin was added to the lesion. An Elekta Oncentra Brachy treatment planning system ver. 4.3 was used for treatment planning. 40 Gy in 10 or 8 fractions was prescribed to the 1cm depth. The Freiburg flap was aligned and verified by CT scanning prior to treatment. Results: Three patients with squamous cell and basal cell carcinoma of the skin were treated with the Freiburg flap applicator. Lesion sizes ranged from 2cm to 6 cm in a maximum dimension. With treatment planning, we made a dose correction for compensating the dose deviation resulting from the incomplete scatter environment of the flap applicators exposed to air. The flap was also covered by a 4cm bolus in order to obtain more back scattered radiation during treatment. Six month follow up showed a very good cosmetic result. Conclusion: The Freiburg flap brachytherapy offers a non-invasive skin cancer treatment with a high skin dose delivered to the tumor while a low dose sparing the surrounding health tissue. It is a promising alternative to skin cancer surgery or external beam radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-319: The Impact of Radiation Beam Obliquity and Air Gap Thickness On Optically Stimulated Luminescent in Vivo Dosimetry for Radiation Therapy

Purpose: Optically-stimulated luminescent dosimeters (OSLDs) are increasingly utilized for in vivo dosimetry of complex radiation delivery techniques. Measured doses, however, underestimate planned doses for plans that utilize thermoplastic mask immobilization. The purpose of this work was to quantify the effect of beam obliquity and air gap span between the mask and backscatter material, on measured-to-planned OSLD dose agreement. Methods: A previously-used thermoplastic mask was cut, reheated, and flattened to form a 33 by 9 cm{sup 2} stage approximately 2 mm thick. Two OSLDs were placed on the stage on 5 cm of solid water, covered with 50 by 50 by 5 mm{sup 3} square of bolus, and scanned in the CT simulator. Plans were created with 10 by 10 cm{sup 2} open fields using 4, 6, 10, and 15 MV photon beams at 0°, 45°, and 90° incidence. The isocenter was placed between the OSLDs at 5 mm depth. Dose was calculated and averaged for two OSLDs. Artificial air gaps of 3, 5, 10, and 20 mm were introduced in the plan and dose was recalculated for each energy/angle/gap combination. The experimental setup was replicated on a linear accelerator and air gaps were introduced by “bridging” the thermoplastic stage across solid water plastic of varying thickness. Fields were delivered as planned. OSLDs were read 12–15 hours after irradiation. Results: Measured-toplanned percent differences were constant with increasing gap thickness for 0° and 45° beam angles. At 90° and 0 cm gap, planned dose underestimated measured dose by 10–23% for all energies. This discrepancy decreased linearly to 0% with a 20 mm gap. OSLD signal did not decrease more than 6% for any gap span and energy. Conclusion: With the exception of parallel beam incidence, beam obliquity and air gap thickness did not have a substantial effect on measured-to-planned dose agreement.

07 ISOTOPE AND RADIATION SOURCES↗

Protecting Privacy of Shared Epidemiologic Data without Compromising Analysis Potential

Objective . Ensuring privacy of research subjects when epidemiologic data are shared with outside collaborators involves masking (modifying) the data, but overmasking can compromise utility (analysis potential). Methods of statistical disclosure control for protecting privacy may be impractical for individual researchers involved in small-scale collaborations. Methods . We investigated a simple approach based on measures of disclosure risk and analytical utility that are straightforward for epidemiologic researchers to derive. The method is illustrated using data from the Japanese Atomic-bomb Survivor population. Results . Masking by modest rounding did not adequately enhance security but rounding to remove several digits of relative accuracy effectively reduced the risk of identification without substantially reducing utility. Grouping or adding random noise led to noticeable bias. Conclusions . When sharing epidemiologic data, it is recommended that masking be performed using rounding. Specific treatment should be determined separately in individual situations after consideration of the disclosure risks and analysis needs.

Cologne, John↗

rubblepy

This code can be used to generate a damage map based on the presence of rubble. Rubble is often detectable in images with submeter resolution, and can indicate damage to structures from high winds or earthquakes. The process_images.py script outputs a mask indicating the pixels in the original image where rubble was detected. The mask can be used in a geospatial software application like ArcMap to generate a damage map based on the rubble density. The rubble detection mask will contain some false positives which are usually more isolated than true rubble, so a density map will provide a more accurate indication of affected areas than the indivdidual rubble detections will.

Matzner, Shari↗

Deep Learning Denoiser

SAND2022-14744 O The Deep Learning Denoiser uses a trained deep convolutional neural network (CNN) model to decompose an input waveform into a signal and noise waveform. In the approach, the CNN provides a signal mask and a noise mask for an input signal. The Short-Time Fourier Transform (STFT) of the estimated signal is obtained by multiplying the signal mask with the STFT of the input signal. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Koch, Clinton↗

pnnl/SAMIAm

We apply semantic boosting to the Segment Anything Model (SAM) to obtain microstructure segmentation for transmission electron microscopy. Our booster, SAM-I-Am, extracts geometric and textural features of various intermediate masks to perform mask removal and mask merging operations

Mesfin, Waqwoya↗

Contributions of Different Cloud Types to Feedbacks and Rapid Adjustments in CMIP5*

When using five climate model simulations of the response to an abrupt quadrupling of CO 2 , the authors perform the first simultaneous model intercomparison of cloud feedbacks and rapid radiative adjustments with cloud masking effects removed, partitioned among changes in cloud types and gross cloud properties. After CO 2 quadrupling, clouds exhibit a rapid reduction in fractional coverage, cloud-top pressure, and optical depth, with each contributing equally to a 1.1 W m -2 net cloud radiative adjustment, primarily from shortwave radiation. Rapid reductions in midlevel clouds and optically thick clouds are important in reducing planetary albedo in every model. As the planet warms, clouds become fewer, higher, and thicker, and global mean net cloud feedback is positive in all but one model and results primarily from increased trapping of longwave radiation. As was true for earlier models, high cloud changes are the largest contributor to intermodel spread in longwave and shortwave cloud feedbacks, but low cloud changes are the largest contributor to the mean and spread in net cloud feedback. The importance of the negative optical depth feedback relative to the amount feedback at high latitudes is even more marked than in earlier models. Furthermore, the authors show that the negative longwave cloud adjustment inferred in previous studies is primarily caused by a 1.3 W m -2 cloud masking of CO 2 forcing. Properly accounting for cloud masking increases net cloud feedback by 0.3 W m -2 K -1 , whereas accounting for rapid adjustments reduces by 0.14 W m -2 K -1 the ensemble mean net cloud feedback through a combination of smaller positive cloud amount and altitude feedbacks and larger negative optical depth feedbacks.

58 GEOSCIENCES↗

Immobilization of biomolecules onto surfaces according to ultraviolet light diffraction patterns

We developed a method for immobilization of biomolecules onto thiol functionalized surfaces according to UV diffraction patterns. UV light-assisted molecular immobilization proceeds through the formation of free, reactive thiol groups that can bind covalently to thiol reactive surfaces. We demonstrate that, by shaping the pattern of the UV light used to induce molecular immobilization, one can control the pattern of immobilized molecules onto the surface. Using a single-aperture spatial mask, combined with the Fourier transforming property of a focusing lens, we show that submicrometer (0.7 {mu}m) resolved patterns of immobilized prostate-specific antigen biomolecules can be created. If a dual-aperture spatial mask is used, the results differ from the expected Fourier transform pattern of the mask. It appears as a superposition of two diffraction patterns produced by the two apertures, with a fine structured interference pattern superimposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of an apodized imaged Hartmann wavefront sensor

Here, quantitative wavefront measurements are demonstrated using a Hartmann mask re-imaged onto a camera. The wavefront is reconstructed using standard algorithms applied to the difference of beamlet centroids determined from fluence distributions obtained for two different longitudinal locations of the mask. The wavefront of the optical wave in the object plane is measured independently of imaging-system collimation. Apodization obtained with spatially dithered distributions of small transparent or opaque pixels improves the measurement accuracy by reducing the spatial-frequency content of the mask holes. Simulations and experiments demonstrate the excellent accuracy of this diagnostic over a wide range of parameters, making it suitable, for example, to characterize laser systems.

47 OTHER INSTRUMENTATION↗

Achieving Hard X-ray Nanofocusing Using a Wedged Multilayer Laue Lens

Here, we report on the fabrication and the characterization of a wedged multilayer Laue lens for x-ray nanofocusing. The lens was fabricated using a sputtering deposition technique, in which a specially designed mask was employed to introduce a thickness gradient in the lateral direction of the multilayer. X-ray characterization shows an efficiency of 27% and a focus size of 26 nm at 14.6 keV, in a good agreement with theoretical calculations. Our results indicate that the desired wedging is achieved in the fabricated structure. Furthermore, we anticipate that continuous development on wedged MLLs will advance x-ray nanofocusing optics to new frontiers and enrich capabilities and opportunities for hard X-ray microscopy.

42 ENGINEERING↗

Synchrotron Infrared Confocal Microspectroscopical Detection of Heterogeneity Within Chemically Modified Single Starch Granules

This reports the first detection of chemical heterogeneity in octenyl succinic anhydride modified single starch granules using a Fourier transform infrared (FT-IR) microspectroscopical technique that combines diffraction-limited infrared microspectroscopy with a step size that is less than the mask projected spot size focused on the plane of the sample. The high spatial resolution was achieved with the combination of the application of a synchrotron infrared source and the confocal image plane masking system of the double-pass single-mask Continuum{reg_sign} infrared microscope. Starch from grains such as corn and wheat exists in granules. The size of the granules depends on the plant producing the starch. Granules used in this study typically had a median size of 15 {micro}m. In the production of modified starch, an acid anhydride typically is reacted with OH groups of the starch polymer. The resulting esterification adds the ester carbonyl (1723 cm{sup -1}) organic functional group to the polymer and the hydrocarbon chain of the ester contributes to the CH{sub 2} stretching vibration to enhance the intensity of the 2927 cm{sup -1} band. Detection of the relative modifying population on a single granule was accomplished by ratioing the baseline adjusted peak area of the carbonyl functional group to that of a carbohydrate band. By stepping a confocally defined infrared beam as small as 5 {micro}m x 5 {micro}m across a starch granule 1 {micro}m at a time in both the x and y directions, the heterogeneity is detected with the highest possible spatial resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of two different methods of image analysis for the assessment of microglial activation in patients with multiple sclerosis using (R)-[N-methyl-carbon-11]PK11195

Chronic active multiple sclerosis (MS) lesions have a rim of activated microglia/macrophages (m/M) leading to ongoing tissue damage, and thus represent a potential treatment target. Activation of this innate immune response in MS has been visualized and quantified using PET imaging with [ 11C]-(R)-PK11195 (PK). Accurate identification of m/M activation in chronic MS lesions requires the sensitivity to detect lower levels of activity within a small tissue volume. We assessed the ability of kinetic modeling of PK PET data to detect m/M activity in different central nervous system (CNS) tissue regions of varying sizes and in chronic MS lesions. Ten patients with MS underwent a single brain MRI and two PK PET scans 2 hours apart. Volume of interest (VOI) masks were generated for the white matter (WM), cortical gray matter (CGM), and thalamus (TH). The distribution volume (VT) was calculated with the Logan graphical method (LGM-VT) utilizing an image-derived input function (IDIF). The binding potential (BPND) was calculated with the reference Logan graphical method (RLGM) utilizing a supervised clustering algorithm (SuperPK) to determine the non-specific binding region. Masks of varying volume were created in the CNS to assess the impact of region size on the various metrics among high and low uptake regions. Chronic MS lesions were also evaluated and individual lesion masks were generated. The highest PK uptake occurred the TH and lowest within the WM, as demonstrated by the mean time activity curves. In the TH, both reference and IDIF based methods resulted in estimates that did not significantly depend on VOI size. However, in the WM, the test-retest reliability of BPND was significantly lower in the smallest VOI, compared to the estimates of LGM-VT. These observations were consistent for all chronic MS lesions examined. In this study, we demonstrate that BPND and LGM-VT are both reliable for quantifying m/M activation in regions of high uptake, however with blood input function LGM-VT is preferred to assess longitudinal m/M activation in regions of relatively low uptake, such as chronic MS lesions.

60 APPLIED LIFE SCIENCES↗

River bank erosion and accretion rates, and planform metrics of the East River, downstream of Gothic Colorado over intervals between 1955 and 2015

This dataset provides the tabular summary of analysis of an alluvial floodplain reach of the East River, downstream of Gothic, CO near Crested Butte. The measurements include bank erosion and accretion rates, channel width, bank curvature, and the aspect/orientation of the river banks. The measurements were derived from binary masks of the location of the river channel from aerial and satellite imagery collected on seven dates over a sixty-year timespan: 1955, 1973, 1983, 1990, 2001, 2011, and 2015. The masks were analyzed using the Spatially Continuous Riverbank Erosion and Accretion Measurements (SCREAM) software detailed in Rowland et al. 2016. The masks used in this analysis can be found an accompanying dataset (DOI: ). Rates of change along the East River were measured over a total of 8-time intervals: 1955-1973; 1955-2015; 1973-1983; 1983-1990; 1990-2001; 2001-2011; 2001-2015; and 2011-2015.In files with “summary” in the name, the data is provided at a pixel level, where each mapped bank pixel has an associated erosion or accretion value, a channel width, a curvature value, and an aspect each river and time period will have an individual file. Files with “Segments” in name provide data that is averaged along segments of the rivers. These segments are approximately 10 channel widths in length. In addition to erosion and accretion rates, the segment-based results include area measurements of erosion and accretion, islands, and channels. The number of islands is also included.

54 ENVIRONMENTAL SCIENCES↗

Deep Learning Denoising Applied to Regional Distance Seismic Data in Utah

Seismic waveform data are generally contaminated by noise from various sources. Suppressing this noise effectively so that the remaining signal of interest can be successfully exploited remains a fundamental problem for the seismological community. To date, the most common noise suppression methods have been based on frequency filtering. These methods, however, are less effective when the signal of interest and noise share similar frequency bands. Inspired by source separation studies in the field of music information retrieval (Jansson et al., 2017) and a recent study in seismology (Zhu et al., 2019), we implemented a seismic denoising method that uses a trained deep convolutional neural network (CNN) model to decompose an input waveform into a signal of interest and noise. In our approach, the CNN provides a signal mask and a noise mask for an input signal. The short-time Fourier transform (STFT) of the estimated signal is obtained by multiplying the signal mask with the STFT of the input signal. To build and test the denoiser, we used carefully compiled signal and noise datasets of seismograms recorded by the University of Utah Seismograph Stations network. Results of test runs involving more than 9000 constructed waveforms suggest that on average the denoiser improves the signal-to-noise ratios (SNRs) by ~5 db, and that most of the recovered signal waveforms have high similarity with respect to the target waveforms (average correlation coefficient of ~0.80) and suffer little distortion. Application to real data suggests that our denoiser achieves on average a factor of up to ~2-5 improvement in SNR over band-pass filtering and can suppress many types of noise that band-pass filtering cannot. For individual waveforms, the improvement can be as high as ~15 db.

58 GEOSCIENCES↗

RivGraph: Automatic extraction and analysis of river and delta channel network topology

River networks sustain life and landscapes by carrying and distributing water, sediment, and nutrients throughout ecosystems and communities. At the largest scale, river networks drain continents through tree-like tributary networks. At typically smaller scales, river deltas and braided rivers form loopy, complex distributary river networks via avulsions and bifurcations.In order to model flows through these networks or analyze network structure, the topology, or connectivity, of the network must be resolved. Additionally, morphologic properties of each river channel as well as the direction of flow through the channel inform how fluxes travel through the network’s channels. Riv Graphis a Python package that automates the extraction and characterization of river channel networks from a user-provided binary image, or mask, of a channel network (Fig. 1). Masks may be derived from (typically remotely-sensed) imagery, simulations, or even hand-drawn. RivGraph will create explicit representations of the channel network by resolving river centerlines as links, and junctions as nodes. Flow directions are solved for each link of the network without using auxiliary data, e.g., a digital elevation model (DEM). Morphologic properties are computed as well, including link lengths, widths, sinuosities, branching angles,and braiding indices. If provided,RivGraph will preserve georeferencing information of the mask and will export results as ESRI shapefiles, GeoJSONs, and GeoTIFFs for easy import into GIS software.RivGraph can also return extracted networks as networkx objects for convenient interfacing with the full-featured networkx package (Hagberg et al., 2008). Finally, RivGraph offers a suite of topologic metrics that were specifically designed for river channel network analysis (Tejedor et al., 2015b).

54 ENVIRONMENTAL SCIENCES↗