Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

The spatial distribution of ultraviolet line and continuum emission in Herbig-Haro objects

Archival IUE data and monochromatic CCD images in the optical range are used to compare the spatial distribution of UV and optical emission in HH 1, HH 2, HH 24, HH 32, HH 43, and HH 47. For all six objects, the observed UV radiation is shown to originate in the objects themselves. The results indicate that the C IV and semiforbidden emission-line regions are small. Although the continuum in the IUE short-wavelength range displays a distribution that is broader than that of any measured line emission in the UV or optical range, the continuum distribution in the IUE long-wavelength range is quite narrow.

Lee, M. G.↗

Optimal focusing for a linac-based hard x-ray source

In spite of having a small average beam current limit, a linac can have features that make it attractive as an x-ray source: high energy, ultralow emittance and energy spread, and flexible beamline optics. Unlike a storage ring, in which an (undulator) radiation source is necessarily short and positioned at an electron beam waist, in a linac the undulator can be long and the electron beam can be adjusted to have a (virtual) waist far downstream toward the x-ray target. Using a planned CEBAF beamline as an example, this paper shows that a factor of 2000 in beam current can be overcome to produce a monochromatic hard x-ray source comparable with, or even exceeding, the performance of an x-ray line at a third generation storage ring. Optimal electron beam focusing conditions for x-ray flux density and brilliance are derived, and are verified by simulations using the SRW code.

43 PARTICLE ACCELERATORS↗

An Algorithm to Calibrate and Correct the Response to Unpolarized Radiation of the X-Ray Polarimeter Onboard IXPE

The Gas Pixel Detector (GPD) is an X-ray polarimeter to fly onboard IXPE and other missions. To correctly measure the source polarization, the response of IXPE’s GPDs to unpolarized radiation has to be calibrated and corrected. In this paper, we describe the way such response is measured with laboratory sources and the algorithm to apply such correction to the observations of celestial sources. The latter allows to correct the response to polarization of single photons, therefore allowing great flexibility in all the subsequent analysis. Our correction approach is tested against both monochromatic and nonmonochromatic laboratory sources and with simulations, finding that it correctly retrieves the polarization up to the statistical limits of the planned IXPE observations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Radiation shielding analysis of the small-angle X-ray scattering flight tube end station of APS upgrade project

The CSSI beamline of the APSU will have a 20.5 m long, 2.75 m diameter SS end station designed to accept pink beam. In this work, the radiation shielding analysis of this end station is analyzed using STAC8 and FLUKA codes. Effect of mirror properties such as reflectivity, coating, inclination and roughness as well as variation in the steel composition are also studied. 8 mm thick SS is found to be adequate if the source is defined by a pinhole and the white beam is reflected with two mirrors inclined at 3.0 mradian or more. The dose rates from monochromatic beams are found to be below the desired levels when the XOP calculated bandwidth (BW) are used while the use of a flat 0.1% BW requires the mirror inclinations to be above 2.5 mradian or more. STAC8 results are consistently higher than the FLUKA results by about 1.5–2.0 times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonant inelastic X-ray scattering using a miniature dispersive Rowland refocusing spectrometer

X-ray absorption spectroscopy (XAS) beamlines worldwide are steadily increasing their emphasis on full photon-in/photon-out spectroscopies, such as resonant inelastic X-ray scattering (RIXS), resonant X-ray emission spectroscopy (RXES) and high energy resolution fluorescence detection XAS (HERFD-XAS). In such cases, each beamline must match the choice of emission spectrometer to the scientific mission of its users. Previous work has recently reported a miniature tender X-ray spectrometer using a dispersive Rowland refocusing (DRR) geometry that functions with high energy resolution even with a large X-ray spot size on the sample. This instrument has been used in the laboratory in multiple studies of non-resonant X-ray emission spectroscopy using a conventional X-ray tube, though only for preliminary measurements at a low-intensity microfocus synchrotron beamline. This paper reports an extensive study of the performance of a miniature DRR spectrometer at an unfocused wiggler beamline, where the incident monochromatic flux allows for resonant studies which are impossible in the laboratory. Here, the results support the broader use of the present design and also suggest that the DRR method with an unfocused beam could have important applications for materials with low radiation damage thresholds and that would not survive analysis on focused beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A scanning angle energy-dispersive X-ray diffraction technique for high-pressure structure studies in diamond anvil cells

A scanning angle diffraction technique with an energy-dispersive solid-state detector (SSD) and white synchrotron radiation has been developed for high-pressure structure studies in diamond anvil cells (DACs). This technique is similar to the CAESAR technique [Y. Wang, T. Uchida, R. Von Dreele, M.L. Rivers, N. Nishiyama, K. Funakoshi, A. Nozawa, and H. Kaneko, A new technique for angle-dispersive powder diffraction using an energy-dispersive setup and synchrotron radiation, J. Appl. Cryst. 37 (2004), p. 947] developed for large-volume presses, but extended to DAC applications with high spatial resolution. The main feature of the technique is the well-defined collimation in the beam path to the detector, which improves the signal-to-noise ratio significantly, compared to routine monochromatic angle-dispersive powder diffraction with area detectors. This is particularly useful and essential for low-scattering materials and for amorphous and liquid diffraction/scattering studies using DACs. Data collected from crystalline and amorphous samples in DACs show that a coarse 2{theta} scan (0.1--0.2{sup o} for crystals and 0.5{sup o} for amorphous structure) is sufficient to obtain reasonable diffraction resolution. The scanning angle energy-dispersive X-ray diffraction technique provides angle-dispersive X-ray diffraction (ADXD) data in multiple energies. Such multi-energy ADXD data carry much more information than regular single-energy ADXD, which could provide site-specific atomic structure information for full structure refinement.

43 PARTICLE ACCELERATORS↗

SU-F-T-398: Improving Radiotherapy Treatment Planning Using Dual Energy Computed Tomography Based Tissue Characterization

Purpose: Both kVp settings and geometric distribution of various materials lead to significant change of the HU values, showing the largest discrepancy for high-Z materials and for the lowest CT scanning kVp setting. On the other hand, the dose distributions around low-energy brachytherapy sources are highly dependent on the architecture and composition of tissue heterogeneities in and around the implant. Both measurements and Monte Carlo calculations show that improper tissue characterization may lead to calculated dose errors of 90% for low energy and around 10% for higher energy photons. We investigated the ability of dual-energy CT (DECT) to characterize more accurately tissue equivalent materials. Methods: We used the RMI-467 heterogeneity phantom scanned in DECT mode with 3 different set-ups: first, we placed high electron density (ED) plugs within the outer ring of the phantom; then we arranged high ED plugs within the inner ring; and finally ED plugs were randomly distributed. All three setups were scanned with the same DECT technique using a single-source DECT scanner with fast kVp switching (Discovery CT750HD; GE Healthcare). Images were transferred to a GE Advantage workstation for DECT analysis. Spectral Hounsfield unit curves (SHUACs) were then generated from 50 to 140-keV, in 10-keV increments, for each plug. Results: The dynamic range of Hounsfield units shrinks with increased photon energy as the attenuation coefficients decrease. Our results show that the spread of HUs for the three different geometrical setups is the smallest at 80 keV. Furthermore, among all the energies and all materials presented, the largest difference appears at high Z tissue equivalent plugs. Conclusion: Our results suggest that dose calculations at both megavoltage and low photon energies could benefit in the vicinity of bony structures if the 80 keV reconstructed monochromatic CT image is used with the DECT protocol utilized in this work.

60 APPLIED LIFE SCIENCES↗

Treatment of atomic and molecular line blanketing by opacity sampling

A sampling technique for treating the radiative opacity of large numbers of atomic and molecular lines in cool stellar atmospheres is subjected to several tests. In this opacity sampling (OS) technique, the global opacity is sampled at only a selected set of frequencies, and at each of these frequencies the total monochromatic opacity is obtained by summing the contribution of every relevant atomic and molecular line. In accord with previous results, we find that the structure of atmospheric models is accurately fixed by the use of 1000 frequency points, and 100 frequency points are adequate for many purposes. The effects of atomic and molecular lines are separately studied. A test model computed using the OS method agrees very well with a model having identical atmospheric parameters, but computed with the giant line (opacity distribution function) method.

Johnson, H. R.↗

Focusing of millijoule picosecond K{sub a}lpha radiation from 100 TW laser-solid interaction

A calibrated x-ray spectrometer was used to characterize an intense 4.5 keV K{sub a}lpha source. Generated from the interaction of 30 J-320 fs laser pulses focused on 25 mum thick Ti foils, the conversion efficiency into Ti K{sub a}lpha line is estimated to (9+-6)x10{sup -5}. Highly efficient collection, monochromatization and focusing were achieved using an ellipsoidally bent highly oriented pyrolytic graphite crystal. The measured 700 mum full width half maximum (FWHM) focal spot leads to a fluence of (3.0+-2.1) mJ/cm{sup 2} hence paving the way to the study of intense x-ray pulse interaction with matter as demonstrated by a first simple experiment.

36 MATERIALS SCIENCE↗

Photovoltaic conversion of laser to electrical power

Transmission of power in space using lasers will require devices for converting the laser power to electrical power. One such type of device for accomplishing this is the photovoltaic converter. This paper reviews photovoltaic converters and their application for conversion of monochromatic laser power to electrical power. Laser power densities greater than 1000 W/sq cm are considered. For a converter operated at 300 K a lower bandgap limit of 0.67 eV (1.80 micron) is defined. For ideal conditions, an efficiency of 47.8 percent is calculated for Nd/Liquid laser radiation incident on an Si converter. Several types of photovoltaic converters are discussed. Series resistance is identified as a major problem. Vertical multijunction converters are the most promising photovoltaic devices for use as laser to electric power converters.

Walker, G. H.↗

Evaluation of high resolution X-ray monochromatic wavelength dispersive X-ray fluorescence instrument for determining Pu and U in nuclear reprocessing streams

In this study, an alpha-prototype benchtop instrument was developed and tested for measuring Pu and U in spent fuel dissolver tanks in a nuclear fuel reprocessing plant. The high resolution X-ray (hiRX) instrument was designed with the aim of providing a new capability to measure samples with high radiation background with selectivity, accuracy, and precision using ultra-low volumes (7 μL) of liquid. The instrument was tested with specimens from the operational reprocessing facility at Savannah River National Laboratory. The results showed that bias was <6% for Pu nitrate process solution and < 18% for Pu in U/HNO 3 matrix. Instrumental precision was <1% RSD while between microcell repeatability was <6% RSD. The limit of detection for Pu in HNO 3 matrix was 3 × 10 -5 g/L (100 s, 35 W). Finally, this study demonstrates that hiRX technology has the potential to provide rapid and simultaneous quantification of Pu and U without sample preparation, making it suitable for process monitoring and materials control and accountability applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum

Purpose: A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x rays emitted from thin targets, irradiated by electron beams circulating in the storage ring, is of primary interest for the design and the characterization of a beamline. This article, Part I, aims at optimizing some of the parameters which are critical for the design of medical applications based on the above compact light source. The goal was to evaluate the dependence of photon fluence and beam monochromaticity on electron-beam energy, target material, and thickness. Methods: The transport of 6 and 20 MeV electrons in a thin molybdenum, rhodium, and tungsten target is studied by means of Monte Carlo simulations using MCNPX. Configurations of the x-ray output port, different from the default forward-directed emission of the beam, are also investigated. A comparison with reference spectra for general diagnostic radiology and mammography is carried out. Results: It is shown that the emitted x-ray beams can be far more intense than those generated by conventional x-ray tubes for radiography applications. The profiles of the calculated polychromatic spectra resemble those generated by conventional x-ray tubes, with x-ray energies up to the energy of the incident-electron beam. An appreciable improvement in the monochromaticity of the beams can be obtained by viewing the x-ray emission from an output port antiparallel to the direction of the incident-electron beam. Conclusions: The optimum target thickness for tungsten target spectra is practically constrained by a trade-off between bremsstrahlung efficiency and focal-spot size requirements. A larger margin for optimization of target thickness is probably available for mammographic spectra. The constraint of a backward-directed (or, to a lesser extent, orthogonal) output port is to be considered mandatory for minimizing the high-energy tail of the spectral distribution and keeping the radiation dose to a reasonable level. It is also fundamental to evaluate the impact of the high-energy tail of the emitted spectra in x-ray imaging applications, since the energy range involved is significantly beyond the diagnostic range. This topic will be dealt with in Part II of the article.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Indium phosphide solar cells for laser power beaming applications

Lasers can be used to transmit power to photovoltaic cells. Solar cell efficiencies are enhanced significantly under monochromatic light, and therefore a laser beam of proper wavelength could be a very effective source of illumination for a solar array operating at very high efficiencies. This work reviews the modeling studies made on indium phosphide solar cells for such an application. These cells are known to be very radiation resistant and have a potential for high efficiency. Effects of cell series resistance, laser intensity, and temperature on cell performance have been discussed.

Jain, Raj K.↗

Opticsconcept for apair of undulatorbeamlines for MX

We describe a concept for X-ray optics to feed a pair of macromolecular crystallography (MX) beamlines, which view canted undulator radiation sources in the same storage ring straight section. It can be deployed at NSLS-II and at other low-emittance third-generation synchrotron radiation sources where canted undulators are permitted, and makes the most of these sources and beamline floor space, even when the horizontal angle between the two canted undulator emissions is as little as 1-2 mrad. The concept adopts the beam-separation principles employed at the 23-ID (GM/CA-CAT) beamlines at the Advanced Photon Source (APS), wherein tandem horizontally deflecting mirrors separate one undulator beam from the other, following monochromatization by a double-crystal monochromator. The scheme described here would, in contrast, deliver the two tunable monochromatic undulator beams to separate endstations that address rather different and somewhat complementary purposes, with further beam conditioning imposed as required. A downstream micro-focusing beamline would employ dual-stage focusing for work at the micron scale and, unique to this design, switch to single-stage focusing for larger beams. On the other hand, the upstream, more highly automated beamline would only employ single-stage focusing.

43 PARTICLE ACCELERATORS↗

Feasibility of one-shot-per-crystal structure determination using Laue diffraction

Structure determination was successfully carried out using single Laue exposures from a group of lysozyme crystals. The Laue method may be a viable option for collection of one-shot-per-crystal data from microcrystals. Crystal size is an important factor in determining the number of diffraction patterns which may be obtained from a protein crystal before severe radiation damage sets in. As crystal dimensions decrease this number is reduced, eventually falling to one, at which point a complete data set must be assembled using data from multiple crystals. When only a single exposure is to be collected from each crystal, the polychromatic Laue technique may be preferable to monochromatic methods owing to its simultaneous recording of a large number of fully recorded reflections per image. To assess the feasibility of solving structures using single Laue images from multiple crystals, data were collected using a ‘pink’ beam at the CHESS D1 station from groups of lysozyme crystals with dimensions of the order of 20–30 µm mounted on MicroMesh grids. Single-shot Laue data were used for structure determination by molecular replacement and correct solutions were obtained even when as few as five crystals were used.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Solar Constant, Climate, and Some Tests of the Storage Hypothesis

Activity related modulation of the solar constant can have practical consequences for climate only if storage is involved, as opposed to a detailed balance between sunspot blocking and facular reemission. Four empirical tests are considered that might distinguish between these opposing interpretations: monochromatic measurements of positive and negative flux; comparison of modelled and measured irradiance variations; the interpretation of secular trends in irradiance data; and the direct test of an anticipated signal in climate records of surface air temperature. The yet unanswered question of the role of faculae as possible reemitters of blocked radiation precludes a definitive answer, although other tests suggest their role to be minor, and that storage and an 11 year modulation is implicated. A crucial test is the behavior of the secular trend in irradiance in the declining years of the present activity cycle.

Eddy, J. A.↗

Results from Solar Reflective Band End-to-End Testing for VIIRS F1 Sensor Using T-SIRCUS

Verification of the Visible Infrared Imager Radiometer Suite (VIIRS) End-to-End (E2E) sensor calibration is highly recommended before launch, to identify any anomalies and to improve our understanding of the sensor on-orbit calibration performance. E2E testing of the Reflective Solar Bands (RSB) calibration cycle was performed pre-launch for the VIIRS Fight 1 (F1) sensor at the Ball Aerospace facility in Boulder CO in March 2010. VIIRS reflective band calibration cycle is very similar to heritage sensor MODIS in that solar illumination, via a diffuser, is used to correct for temporal variations in the instrument responsivity. Monochromatic light from the NIST T-SIRCUS was used to illuminate both the Earth View (EV), via an integrating sphere, and the Solar Diffuser (SD) view, through a collimator. The collimator illumination was cycled through a series of angles intended to simulate the range of possible angles for which solar radiation will be incident on the solar attenuation screen on-orbit. Ideally, the measured instrument responsivity (defined here as the ratio of the detector response to the at-sensor radiance) should be the same whether the EV or SD view is illuminated. The ratio of the measured responsivities was determined at each collimator angle and wavelength. In addition, the Solar Diffuser Stability Monitor (SDSM), a ratioing radiometer designed to track the temporal variation in the SD BRF by direct comparison to solar radiation, was illuminated by the collimator. The measured SDSM ratio was compared to the predicted ratio. An uncertainty analysis was also performed on both the SD and SDSM calibrations.

McIntire, Jeff↗

Observation of Strong Two-Electron-One-Photon Transitions in Few-Electron Ions

We resonantly excite the K series of O5+ and O6+ up to principal quantum number n = 11 with monochromatic x rays, producing K-shell holes, and observe their relaxation by soft-x-ray emission. Some photoabsorption resonances of O5+ reveal strong two-electron–one-photon (TEOP) transitions. We find that for the [(1s2s)15p3/2]3/2;1/2 states, TEOP relaxation is by far stronger than the radiative decay and competes with the usually much faster Auger decay path. This enhanced TEOP decay arises from a strong correlation with the near-degenerate upper states [(1s2p3/2 )14s]3/2;1/2 of a Li-like satellite blend of the He-like Kα transition. Even in three-electron systems, TEOP transitions can play a dominant role, and the present results should guide further research on the ubiquitous and abundant many-electron ions where electronic energy degeneracies are far more common and configuration mixing is stronger.

M Togawa↗