Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Cyclotron radiation emission spectroscopy of electrons from tritium $β$ decay and 83m Kr internal conversion

Project 8 has developed a novel technique, cyclotron radiation emission spectroscopy (CRES), for direct neutrino mass measurements. A CRES-based experiment on the beta spectrum of tritium has been carried out in a small-volume apparatus. Here, we provide a detailed account of the experiment, focusing on systematic effects and analysis techniques. In a Bayesian (frequentist) analysis, we measure the tritium endpoint as ${18}$ ${553}_{—19}^{+18}$ (${18}$ ${548}_{—19}^{+19}$) eV and set upper limits of 155 (152) eV (90% C.L.) on the neutrino mass. No background events are observed beyond the endpoint in 82 days of running. We also demonstrate an energy resolution of 1.66 ± 0.19 eV in a resolution-optimized magnetic trap configuration by measuring 83m Kr 17.8-keV internal-conversion electrons. These measurements establish CRES as a low-background, high-resolution technique with the potential to advance neutrino mass sensitivity

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bose-Einstein Condensation of Alkaline Earth Atoms: {sup 40}Ca

We have achieved Bose-Einstein condensation of {sup 40}Ca, the first for an alkaline earth element. The influence of elastic and inelastic collisions associated with the large ground-state s-wave scattering length of {sup 40}Ca was measured. From these findings, an optimized loading and cooling scheme was developed that allowed us to condense about 2x10{sup 4} atoms after laser cooling in a two-stage magneto-optical trap and subsequent forced evaporation in a crossed dipole trap within less than 3 s. The condensation of an alkaline earth element opens novel opportunities for precision measurements on the narrow intercombination lines as well as investigations of molecular states at the {sup 1}S-{sup 3}P asymptotes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization of flowing liquid films as a regenerating plasma mirror for high repetition-rate laser contrast enhancement

In this paper, we characterize a high repetition-rate regenerating plasma mirror produced by the thin film of liquid formed when two laminar streams collide. The use of a flowing liquid film is inexpensive and the interaction surface refreshes automatically, avoiding buildup of on-target debris. The composition of the liquid material and the relative angle of the film-generating nozzles was optimized for this application. Spectra measured in reflection from a water-based plasma mirror showed a blue shift but an optical reflectivity of up to 30%. The thickness of the film was found to be of the order of 2 μm, and the stability of the reflected spot was ≈1 mrad. The reflected beam profile was highly distorted but stable. Further optimization of the nozzles to affect the fluid flow should enable significant improvements in control of the fluid films and increase in the reflectivity of these mirrors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Characterization of High Thermal Conductivity Pipes from Roll-to- Roll Processed Hybrid Copper-Polymer Strips for Waste Heat Recovery

Metal based heat exchangers targeting low temperature (<150°C) waste heat recovery (WHR) face high maintenance and material costs [1] that result in long payback periods (>1 year). Low-cost polymer pipes suffer from poor thermal conductivity (~0.2 W/m.K), and thus a low overall heat transfer coefficient. Previous reports demonstrated thermal conductivity enhancement in polymers through systematic molecular alignment [2, 3, 4], or by metal micro-particle inclusions [5]. However, these approaches suffer from scalability issues for WHR heat exchangers in terms of cost [1, 3], and thermomechanical considerations [6, 7]. In this work, we propose hybrid metal-polymer strips that are strategically designed to enhance thermal conductivity by cladding copper around polymer strips. The polymer strips with copper-clad edges are wound helically to form the pipes for a heat exchanger. Through numerical simulations, we optimize the copper-polymer strip layouts to achieve high wall thermal conductivity (k > 1 W/m.K) and also have low volume fraction of copper (<70%) for the composite pipes. In copper-polymer composite heat exchangers, the bottlenecks for heat transfer are the thermal interfacial resistances of copper-copper and copper-polymer joints. We experimentally measured interfacial resistances to be ~1x10 -5 K.m 2 /W and ~4x10 -5 K.m 2 /W for copper-copper and copper-polymer joints, respectively. Using the measured interfacial resistances, we further optimized the design of the hybrid pipes to find high thermal conductivity (> 1 W/m.K) designs. We predict up to ~20 % enhancement in overall heat transfer relative to an all polymer (k = 0.2 W/m.K) heat exchanger system. Using a cohesive zone modelling (CZM) for predicting delamination at the weld joints, we find that our hybrid pipes can have operating internal pressures > 200 psi. The optimized designs of hybrid metal-polymer pipes provide a scalable and cost- effective means for harvesting waste heat from low temperature sources. Thekdi, A., and Nimbalkar, S. Oak Ridge National Lab (2014). Shen, Sheng, et al. Nature nanotechnology 5.4 (2010). Xu, Yanfei, et al. Science advances 4.3 (2018). Smith et al. ACS nano, 9(2), (2015). Sofian, N.M., et al., Journal of Thermoplastic Composite Materials (2001). Aymonier et al. Chemistry of Materials, 15(25), (2003). Tavman, I.H., Journal of Applied Polymer Science, 62(12), (1996).

C Rajagopal, Manjunath↗

Colliding Laser Pulses for Laser-Plasma Accelerator Injection Control

Decoupling injection from acceleration is a key challenge to achieve compact, reliable, tunable laser-plasma accelerators (LPA). In colliding pulse injection the beat between multiple laser pulses can be used to control energy, energy spread, and emittance of the electron beam by injecting electrons in momentum and phase into the accelerating phase of the wake trailing the driver laser pulse. At LBNL, using automated control of spatiotemporal overlap of laser pulses, two-pulse experiments showed stable operation and reproducibility over hours of operation. Arrival time of the colliding beam was scanned, and the measured timing window and density of optimal operation agree with simulations. The accelerator length was mapped by scanning the collision point.

43 PARTICLE ACCELERATORS↗

Optimal PMU Restoration for Power System Observability Recovery After Massive Attacks

Cyber-physically resilient power system operation requires rapid recovery of situational awareness after disastrous scenarios such as massive cyber attacks. In this article, the concept of optimal sequential restoration of Phasor Measurement Units is introduced, aiming at rapid recovery of power system observability in post-attack scenarios. Additionally, the observability recovery problem is formulated as a Mixed Integer Linear Programming problem to maximize the cumulative observability level gained over time during the restoration process. Three alternative objective functions-maximizing the number of observable buses, the number of observable branches, and the total amount of observable power flow-are considered. The effectiveness of the proposed optimal strategy is verified by comparing it with heuristic approaches on the IEEE 57-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measuring type Ia supernova angular-diameter distances with intensity interferometry

This paper investigates the potential of intensity interferometry, based on the Hanbury Brown-Twiss effect, for measuring supernova sizes and distances. With optimized telescope positioning, observing strategy, and advancements in single-photon detection technology, this method can provide precise angular size measurements of supernovae with apparent magnitudes as bright as 12 mag. For type Ia supernovae, this limiting brightness corresponds to a local volume extending to redshift z∼0.004 and an anticipated discovery rate of approximately 1 event per year. The combination of angular size data with known physical dimensions enables accurate distance determination. Multiple telescope pairs at different relative positions allow tomographic mapping of the ejecta structure while reducing distance uncertainties. As type Ia supernovae serve as standardizable candles for measuring the Universe’s expansion history, combining intensity interferometry distances with the supernova Hubble diagram facilitates measurements of the Hubble constant H0.

cosmological parameters↗

AWARE: The Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE) performed comprehensive meteorological and aerosol measurements and ground-based atmospheric remote sensing at two Antarctic stations using the most advanced instrumentation available. A suite of cloud research radars, lidars, spectral and broadband radiometers, aerosol chemical and microphysical sampling equipment, and meteorological instrumentation was deployed at McMurdo Station on Ross Island from December 2015 through December 2016. A smaller suite of radiometers and meteorological equipment, including radiosondes optimized for surface energy budget measurement, was deployed on the West Antarctic Ice Sheet between 4 December 2015 and 17 January 2016. AWARE provided Antarctic atmospheric data comparable to several well-instrumented high Arctic sites that have operated for many years and that reveal numerous contrasts with the Arctic in aerosol and cloud microphysical properties. These include persistent differences in liquid cloud occurrence, cloud height, and cloud thickness. Antarctic aerosol properties are also quite different from the Arctic in both seasonal cycle and composition, due to the continent’s isolation from lower latitudes by Southern Ocean storm tracks. Antarctic aerosol number and mass concentrations are not only non-negligible but perhaps play a more important role than previously recognized because of the higher sensitivities of clouds at the very low concentrations caused by the large-scale dynamical isolation. Antarctic aerosol chemical composition, particularly organic components, has implications for local cloud microphysics. The AWARE dataset, fully available online in the ARM Program data archive, offers numerous case studies for unique and rigorous evaluation of mixed-phase cloud parameterization in climate models.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-191: Commissioning and Dosimetric Characteristics of Elekta Agility for Total Skin Electron Beam (TSEB) Therapy

Purpose The purpose of this work is to publish beam data from Elekta Synergy(R) linear accelerators with Agility(TM) MLC for total skin electron beam (TSEB) therapy using the HDRE1 (High Dose Rate Electron 6MeV) energy. Method & Materials The optimal gantry angles for TSEB were determined using ion chamber measurements along a vertical profile at 450cm SSD. After gantry angles were chosen, field uniformity was measured over the entire treatment area. Uniformity was measured with and without the patient support device, allowing the dosimetric effect of the support device to be determined. Beam output and PDD were measured at the calibration point (450cm SSD) for a dual beam using a parallel plate chamber in solid water. These measurements were repeated with the chamber and phantom rotated about the patient isocenter at various angles, in order to measure the contribution from oblique beams. This technique provides a precise measurement of the treatment skin dose (TSD). Lastly, ion chamber measurements were verified by film and diodes. Results The optimal gantry angle for 450 cm SSD was determined to be 90±16°. This achieved uniformity better than 96% on the vertical axis, and 92% along the horizontal axis. HDRE1 was calibrated to deliver 10 cGy/MU at standard geometry (100 cm SSD, 1.2 cm depth). Thus at TSEB geometry (450 cm SSD, 0.1 cm depth) the output of the AP dual field was measured to be 0.35 cGy/MU. The TSD of a 20 cm radius cylinder for six (equally, 60° spaced) dual fields was measured to be 1.19 cGy/MU. Percent Depth Dose data for the AP dual field and TSD are shown in Figure 2. Conclusion This paper provides a modern procedure for commissioning TSEB therapy on a linear accelerator, and clinical beam data for the Elekta Synergy(R) with Agility(TM) MLC.

60 APPLIED LIFE SCIENCES↗

A Geometric Measure Theory Approach to Identify Complex Structural Features on Soft Matter Surfaces

The structural features that protrude above or below a soft matter interface are well-known to be related to interfacially mediated chemical reactivity and transport processes. It is a challenge to develop a robust algorithm for identifying these organized surface structures, as the morphology can be highly varied and they may exist on top of an interface containing significant interfacial roughness. A new algorithm that employs concepts from geometric measure theory, algebraic topology, and optimization is developed to identify candidate structures at a soft matter surface, and then, using a probabilistic approach, to rank their likelihood of being a complex structural feature. The algorithm is tested for a surfactant laden water/oil interface, where it is robust to identifying protrusions responsible for water transport against a set identified by visual inspection. To our knowledge, this is the first example of applying geometric measure theory to analyze the properties of a chemical/materials science system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extended flexibility of neutron Larmor diffraction for increased diffraction range in mosaicity measurements

Larmor diffraction (LD) is a neutron scattering technique that offers enhanced resolution by harnessing the Larmor precession of neutron spins in a magnetic field. By encoding subtle changes in neutron momentum transfer into significant alterations in the Larmor phase of neutron spins, LD can be employed to measure lattice expansion, lattice distortion, and mosaicity with exceptional resolution. As originally proposed by Rekveldt et al., LD necessitates the magnetic field boundaries to be tilted to be parallel to the crystal plane of interest. Here, this report explores the fundamental principles shared between LD and spin-echo small-angle neutron scattering (SESANS). Drawing inspiration from the flexibility of SESANS to adjust magnetic field boundaries to optimize the resolution in the measurement of the neutron momentum transfers q, we will demonstrate that the strict requirement of parallel alignment between the magnetic field boundaries and the crystal plane can be relaxed for the measurements of mosaicity. Such relaxation will expand the accessible diffraction angles for these situations that are highly constrained.

Larmor diffraction↗

Entanglement and symmetry in permutation-symmetric states

We investigate the relationship between multipartite entanglement and symmetry, focusing on permutation symmetric states. We give a highly intuitive geometric interpretation to entanglement via the Majorana representation, where these states correspond to points on a unit sphere. We use this to show how various entanglement properties are determined by the symmetry properties of the states. The geometric measure of entanglement is thus phrased entirely as a geometric optimization and a condition for the equivalence of entanglement measures written in terms of point symmetries. Finally, we see that different symmetries of the states correspond to different types of entanglement with respect to interconvertibility under stochastic local operations and classical communication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of LAPPD timing at CERN PS testbeam

Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm 2 sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns rise time followed by a slightly longer fall time and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. Finally, the measured time resolution for single photoelectrons is about 80 ps r.m.s.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of rabbit eardrum vibration through stroboscopic digital holography

In this work, we present a setup for high-power single shot stroboscopic digital holography and demonstrate it in an application on rabbit eardrum vibration measurement. The setup is able to make full-field time-resolved measurements of vibrating surfaces with a precision in the nanometer range in a broad frequency range. The height displacement of the measured object is visualized over the entire surface as a function of time. Vibration magnitude and phase maps can be extracted from these data, the latter proving to be very useful to reveal phase delays across the surface. Such deviations from modal motion indicate energy losses due to internal damping, in contrast to purely elastic mechanics. This is of great interest in middle ear mechanics and finite element modelling. In our setup, short laser pulses are fired at selected instants within the surface vibration period and are recorded by a CCD camera. The timing of the pulses and the exposure of the camera are synchronized to the vibration phase by a microprocessor. The high-power frequency-doubled Nd:YAG laser produces pulses containing up to 5 mJ of energy, which is amply sufficient to record single-shot holograms. As the laser pulse length is 8 ns and the smallest time step of the trigger electronics is 1 μs, vibration measurements of frequencies up to 250 kHz are achievable through this method, provided that the maximum vibration amplitude exceeds a few nanometers. In our application, middle ear mechanics, measuring frequencies extend from 5 Hz to 20 kHz. The experimental setup will be presented, as well as results of measurements on a stretched circular rubber membrane and a rabbit's eardrum. Two of the challenges when measuring biological tissues, such as the eardrum, are low reflectivity and fast dehydration. To increase reflectivity, a coating is applied and to counteract the undesirable effects of tissue dehydration, the measurement setup and software have been optimized for speed without compromising on the quality. Results of a repeatability test will be presented as well. Since the method measures the membrane motion as a function of time in small time steps, we do not only measure vibration amplitude like in time-average holography, but we can also measure non-linear elastic and transient behaviour. In conclusion, the combination of good spatial, depth and time resolution with the fast data acquisition and very wide frequency range make our technique applicable in a number of fields, including biological tissue vibrations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High fidelity ultrasound imaging of concrete structures

As plans are made to extend licenses for the aging fleet of commercial nuclear power plants for periods of sixty years and beyond, research into the long-term integrity of their concrete structures has increased. Ultrasound tomography is a useful tool for nondestructive evaluation of these concrete structures. Typically, pulse-echo measurements are made over a large surface and are processed using a reconstruction algorithm, producing a 3D image of the structure that highlights embedded defects. These measurements are processed using a delay-and-sum algorithm such as the synthetic aperture focusing technique (SAFT). Oak Ridge National Laboratory is developing novel ultrasound model-based image reconstruction (U-MBIR) algorithms to improve the imaging capability of pulse-echo ultrasound array imagers. U-MBIR is an inversion technique that reconstructs the sample under test from the ultrasound measurements by formulating and solving a mathematical optimization problem using two sets of terms: one set ensures that the reconstruction matches measured data based on a model for the physics of beam propagation with the noise in the detector, and another set ensures that the reconstruction has certain properties based on a model for the object being scanned. This paper compares three techniques: SAFT, frequency-banded SAFT (FB-SAFT), and U-MBIR. The U-MBIR method produces higher quality images of the underlying concrete structures compared to the images produced using SAFT and FB-SAFT from the same set of measurements. This paper also illustrates the detection of various defects with higher confidence due to the lower noise and artifact-free U-MBIR images.

Ezell, N Dianne↗

PASSAT: particle accelerator helioScopes for Slim Axion-like-particle deTection

We propose a novel method to search for axion-like particles (ALPs) at particle accelerator experiments. ALPs produced at the target via the Primakoff effect subsequently enter a region with a magnetic field, where they are converted to photons that are then detected. Dubbed Particle Accelerator helioScopes for Slim Axion-like-particle deTection (PASSAT), our proposal uses the principle of the axion helioscope but replaces ALPs produced in the Sun with those produced in a target material. Since we rely on ALP-photon conversions , our proposal probes light (slim) ALPs that are otherwise inaccessible to laboratory-based experiments which rely on ALP decay, and complements astrophysical probes that are more model-dependent. As a first application, we reinterpret existing data from the NOMAD experiment in light of PASSAT, and constrain the parameter space for ALPs lighter than $$\sim 100~\mathrm{eV}$$ ~ 100 eV and ALP-photon coupling larger than $$\sim 10^{-4}~\mathrm{GeV}^{-1}$$ ~ 10 - 4 GeV - 1 . As benchmarks of feasible low-cost experiments improving over the NOMAD limits, we study the possibility of re-using the magnets of the CAST and the proposed BabyIAXO experiments and placing them at the proposed BDF facility at CERN, together with some new detectors. We find that these realizations of PASSAT allow for a direct probe of the parameter space for ALPs lighter than $$\sim 100~\mathrm{eV}$$ ~ 100 eV and ALP-photon coupling larger than $$\sim 4\times 10^{-6}~\mathrm{GeV}^{-1}$$ ~ 4 × 10 - 6 GeV - 1 , which are regions that have not been probed yet by experiments with laboratory-produced ALPs. In contrast to other proposals aiming at detecting single or two-photon only events in hadronic beam dump environments, that rely heavily on Monte Carlo simulations, the background in our proposal can be directly measured in-situ , its suppression optimized, and the irreducible background statistically subtracted. Sensitivity evaluations with other beams will be the subject of a future paper. The measurements suggested in this paper represent an additional physics case for the BDF at CERN beyond those already proposed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In situ quantification of fracture slip induced by hydraulic injections in a deep borehole: A comparison of two different borehole techniques

In situ measurements of fracture deformation during fluid injection are rare, yet essential for understanding the mechanical response of fractured rock. In this study, we evaluate the reliability of two methods by comparing their slip vector estimates: high-resolution borehole acoustic televiewer images captured before and after injection tests, and displacement data from a three-component borehole deformation probe recorded during the injections. Acoustic televiewer images capture only final in-plane displacement, whereas three-component borehole deformation measurements provide full 3D, transient fracture movement. Four injection tests in a fractured granitic rock mass along an inclined borehole at the Bedretto Underground Laboratory (Switzerland), beneath more than 1100 m of overburden, were analyzed. The two methods yielded consistent kinematics and comparable slip magnitudes, typically in the range of 0.2 – 0.6 mm. Angular differences between estimated slip directions ranged from 0.2° to 28°. For two test intervals with pre-existing fractures optimally oriented for slip, the measured slip vectors agreed with forward-modeled slip vectors based on the regional in situ stress field, supporting the Wallace–Bott hypothesis. Measurable shear displacement was identified in two test intervals containing fractures oriented nearly perpendicular to the least principal stress, including a newly formed hydraulic fracture. This demonstrates that even fractures unfavorably oriented for slip can undergo shear due to local stress perturbations around an inclined borehole.

Acoustic televiewer↗

Mathematical efficiency calibration with uncertain source geometries using smart optimization

The In Situ Object Counting Software (ISOCS), a mathematical method developed by CANBERRA, is a well established technique for computing High Purity Germanium (HPGe) detector efficiencies for a wide variety of source shapes and sizes. In the ISOCS method, the user needs to input the geometry related parameters such as: the source dimensions, matrix composition and density, along with the source-to-detector distance. In many applications, the source dimensions, the matrix material and density may not be well known. Under such circumstances, the efficiencies may not be very accurate since the modeled source geometry may not be very representative of the measured geometry. CANBERRA developed an efficiency optimization software known as 'Advanced ISOCS' that varies the not well known parameters within user specified intervals and determines the optimal efficiency shape and magnitude based on available benchmarks in the measured spectra. The benchmarks could be results from isotopic codes such as MGAU, MGA, IGA, or FRAM, activities from multi-line nuclides, and multiple counts of the same item taken in different geometries (from the side, bottom, top etc). The efficiency optimization is carried out using either a random search based on standard probability distributions, or using numerical techniques that carry out a more directed (referred to as 'smart' in this paper) search. Measurements were carried out using representative source geometries and radionuclide distributions. The radionuclide activities were determined using the optimum efficiency and compared against the true activities. The 'Advanced ISOCS' method has many applications among which are: Safeguards, Decommissioning and Decontamination, Non-Destructive Assay systems and Nuclear reactor outages maintenance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗