Search NASA⌕ Search

SEARCH · Search NASA

Results for “Methods:data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Dynamics retrieval from stochastically weighted incomplete data by low-pass spectral analysis

Time-resolved serial femtosecond crystallography (TR-SFX) provides access to protein dynamics on sub-picosecond timescales, and with atomic resolution. Due to the nature of the experiment, these datasets are often highly incomplete and the measured diffracted intensities are affected by partiality. To tackle these issues, one established procedure is that of splitting the data into time bins, and averaging the multiple measurements of equivalent reflections within each bin. This binning and averaging often involve a loss of information. Here, we propose an alternative approach, which we call low-pass spectral analysis (LPSA). In this method, the data are projected onto the subspace defined by a set of trigonometric functions, with frequencies up to a certain cutoff. This approach attenuates undesirable high-frequency features and facilitates retrieving the underlying dynamics. A time-lagged embedding step can be included prior to subspace projection to improve the stability of the results with respect to the parameters involved. Subsequent modal decomposition allows to produce a low-rank description of the system's evolution. Using a synthetic time-evolving model with incomplete and partial observations, we analyze the LPSA results in terms of quality of the retrieved signal, as a function of the parameters involved. We compare the performance of LPSA to that of a range of other sophisticated data analysis techniques. We show that LPSA allows to achieve excellent dynamics reconstruction at modest computational cost. Finally, we demonstrate the superiority of dynamics retrieval by LPSA compared to time binning and merging, which is, to date, the most commonly used method to extract dynamical information from TR-SFX data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining biomolecular structures near room temperature using X-ray crystallography: concepts, methods and future optimization

For roughly two decades, cryocrystallography has been the overwhelmingly dominant method for determining high-resolution biomolecular structures. Competition from single-particle cryo-electron microscopy and micro-electron diffraction, increased interest in functionally relevant information that may be missing or corrupted in structures determined at cryogenic temperature, and interest in time-resolved studies of the biomolecular response to chemical and optical stimuli have driven renewed interest in data collection at room temperature and, more generally, at temperatures from the protein–solvent glass transition near 200 K to ∼350 K. Fischer has recently reviewed practical methods for room-temperature data collection and analysis [Fischer (2021), Q. Rev. Biophys. 54 , e1]. Here, the key advantages and physical principles of, and methods for, crystallographic data collection at noncryogenic temperatures and some factors relevant to interpreting the resulting data are discussed. For room-temperature data collection to realize its potential within the structural biology toolkit, streamlined and standardized methods for delivering crystals prepared in the home laboratory to the synchrotron and for automated handling and data collection, similar to those for cryocrystallography, should be implemented.

59 BASIC BIOLOGICAL SCIENCES↗

Solution of the inverse problem in spherical gravitational wave detectors using a model with independent bars

The direct detection of gravitational waves will provide valuable astrophysical information about many celestial objects. The SCHENBERG has already undergone its first test run. It is expected to have its first scientific run soon. In this work a new data analysis approach is presented, called the method of independent bars, which can be used with SCHENBERG's data. We test this method through the simulation of the detection of gravitational waves. With this method we find the source's direction without the need to have all six transducers operational. Also, we show that the method is a generalization of another one, already described in the literature, known as the mode channels method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Posteriori Error Analysis of a Cell-centered Finite Volume Method for Semilinear Elliptic Problems

In this paper, we conduct an a posteriori analysis for the error in a quantity of interest computed from a cell-centered finite volume scheme. The a posteriori error analysis is based on variational analysis, residual error and the adjoint problem. To carry out the analysis, we use an equivalence between the cell-centered finite volume scheme and a mixed finite element method with special choice of quadrature.

99 GENERAL AND MISCELLANEOUS↗

Changing Institutional Procurement Behavior to Achieve Energy Savings

Although federal policies regarding energy-efficient product procurement (EEPP) are long-standing and well-established, federal buyers do not typically request energy-efficient products when making purchases. This is a large missed opportunity: full compliance could save the U.S. federal government roughly $500 million in energy cost annually. In 2016, the U.S. Department of Energy’s Federal Energy Management Program (FEMP) began a new set of program activities to increase federal compliance with these procurement requirements. Program interventions included increased communication with contracting officers during the solicitation process; development of enhanced, targeted training; and collection and dissemination of procurement best practices across the federal sector. We have collected and analyzed ~2,500 solicitations from over 40 different federal agencies to evaluate the influence of these interventions. Compared to pre-intervention years (FY15 and FY11), annual compliance rates for FY16 and FY17 increased by about 10%. This paper provides an overview of the data collection process, analysis framework, intervention method, and results of our analysis. We discuss strategies to increase compliance rates by examining institutional factors that drive procurement behavior. By combining data collection with adjustment to program implementation, we have created an iterative process that is having a demonstrable effect in improving the impact of a long-running program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SAS PDF: pair distribution function analysis of nanoparticle assemblies from small-angle scattering data

SASPDF, a method for characterizing the structure of nanoparticle assemblies (NPAs), is presented. The method is an extension of the atomic pair distribution function (PDF) analysis to the small-angle scattering (SAS) regime. The PDFgetS3 software package for computing the PDF from SAS data is also presented. An application of the SASPDF method to characterize structures of representative NPA samples with different levels of structural order is then demonstrated. The SASPDF method quantitatively yields information such as structure, disorder and crystallite sizes of ordered NPA samples. The method was also used to successfully model the data from a disordered NPA sample. The SASPDF method offers the possibility of more quantitative characterizations of NPA structures for a wide class of samples.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Search for neutrinoless β + EC decay of Te 120 with CUORE-0

Here, we have performed a search for neutrinoless $\beta^{+}\hspace{-0.2em}EC$ decay of $^{120}$Te using the final CUORE-0 data release. We describe a new analysis method for the simultaneous fit of signatures with different event topology, and of data subsets with different signal efficiency, obtaining a limit on the half-life of the decay of $T_{1/2}>1.6\cdot10^{21}$ yr at $90\%$ CI. Combining this with results from Cuoricino, a predecessor experiment, we obtain the strongest limit to date, corresponding to $T_{1/2}>2.7\cdot10^{21}$ yr at $90\%$ CI.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High frequency, high time resolution time-to-digital converter employing passive resonating circuits

A method for measuring time intervals accurate to the picosecond range is based on phase measurements of oscillating waveforms synchronous with their beginning and/or end. The oscillation is generated by triggering an LC resonant circuit, whose capacitance is precharged. By using high Q resonators and a final active quenching of the oscillation, it is possible to conjugate high time resolution and a small measurement time, which allows a high measurement rate. Methods for fast analysis of the data are considered and discussed with reference to computing resource requirements, speed, and accuracy. Experimental tests show the feasibility of the method and a time accuracy better than 4 ps rms. Methods aimed at further reducing hardware resources are finally discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Effect of Data Transformations on Scalar Field Topological Analysis of High-Order FEM Solutions

High-order finite element methods (HO-FEM) are gaining popularity in the simulation community due to their success in solving complex flow dynamics. There is an increasing need to analyze the data produced as output by these simulations. Simultaneously, topological analysis tools are emerging as powerful methods for investigating simulation data. Yet, most of the current approaches to topological analysis have had limited application to HO-FEM simulation data for two reasons. First, the current topological tools are designed for linear data (polynomial degree one), but the polynomial degree of the data output by these simulations is typically higher (routinely up to polynomial degree six). Second, the simulation data and derived quantities of the simulation data have discontinuities at element boundaries, and these discontinuities do not match the input requirements for the topological tools. One solution to both issues is to transform the high-order data to achieve low-order, continuous inputs for topological analysis. Nevertheless, there has been little work evaluating the possible transformation choices and their downstream effect on the topological analysis. We perform an empirical study to evaluate two commonly used data transformation methodologies along with the recently introduced L-SIAC filter for processing high-order simulation data. Our findings indicate diverse behaviors are possible. We offer some guidance about how best to consider a pipeline of topological analysis of HO-FEM simulations with the currently available implementations of topological analysis.

97 MATHEMATICS AND COMPUTING↗

SU-F-T-464: Development of a Secondary Check Procedure to Evaluated Flatness and Symmetry Discrepancies Detected During Daily Morning QA

Purpose: A daily QA device is used to monitor output, flatness and symmetry constancy for all linac photon and electron energies. If large deviations from baseline in flatness or symmetry are reported it becomes necessary to crosscheck the measurements with a second device. Setting up another device such as Matrixx (IBA Dosimetry) can be time consuming, due to its warm-up time, and trained personnel may not be readily available to analyze the results. Furthermore, this discrepancy is frequently isolated to a single energy. Unaffected energies could still be used, avoiding further patient delays, if a method to gather data for offline analysis could be developed. We find that optically stimulated luminescent dosimeters (OSLDs) provide a quick, simple, and inexpensive solution to this important clinical problem. Methods: The exact geometry of the detectors on the daily tracker (Keithley Therapy Beam Evaluator) was reproduced by placing nanoDot OSLDs (Landauer) on a solid water phantom. A combination of bolus and solid water was placed on top to provide buildup and prevent air gaps. Standard daily measurements of output, flatness and symmetry were taken for 2 photon energies (6x,10x) and 5 electron energies (6e,9e,12e,15e,18e) using the tracker. These measurements were then repeated with the OSLD phantom. Results: The time it took to set up the OSLD phantom was comparable to that of the tracker. The inline and crossline OSLD phantom measurements of flatness and symmetry agreed with the tracker results to within 2%. Conclusion: OSLDs provide a good solution for a quick second check when questionable flatness and symmetry results are detected with the tracker during daily QA.

60 APPLIED LIFE SCIENCES↗

Prony Ringdown GUI (CERTS Prony Ringdown, part of the DSI Tool Box)

The PNNL Prony Ringdown graphical user interface is one analysis tool included in the Dynamic System Identification toolbox (DSI Toolbox). The Dynamic System Identification toolbox is a MATLAB-based collection of tools for parsing and analyzing phasor measurement unit data, especially in regards to small signal stability. It includes tools to read the data, preprocess it, and perform small signal analysis. 5. Method of Solution: The Dynamic System Identification Toolbox (DSI Toolbox) is designed to provide a research environment for examining phasor measurement unit data and performing small signal stability analysis. The software uses a series of text-driven menus to help guide users and organize the toolbox features. Methods for reading in populate phasor measurement unit data are provided, with appropriate preprocessing options for small-signal-stability analysis. The toolbox includes the Prony Ringdown GUI and basic algorithms to estimate information on oscillatory modes of the system, such as modal frequency and damping ratio.

Tuffner, Francis↗

SCALE-6 Sensitivity/Uncertainty Methods and Covariance Data

Computational methods and data used for sensitivity and uncertainty analysis within the SCALE nuclear analysis code system are presented. The methodology used to calculate sensitivity coefficients and similarity coefficients and to perform nuclear data adjustment is discussed. A description is provided of the SCALE-6 covariance library based on ENDF/B-VII and other nuclear data evaluations, supplemented by 'low-fidelity' approximate covariances.

99 GENERAL AND MISCELLANEOUS↗

A General Framework for Monitoring Image Acquisition Workflow in the Radiology Environment: Timeliness for Acute Stroke CT Imaging

Many facets of an image acquisition workflow leave a digital footprint, making workflow analysis amenable to an informatics-based solution. This paper describes a detailed framework for analyzing workflow and uses acute stroke response timeliness in CT as a practical demonstration. We review methods for accessing the digital footprints resulting from common technologist/device interactions. This overview lays a foundation for obtaining data for workflow analysis. We demonstrate the method by analyzing CT imaging efficiency in the setting of acute stroke. We successfully used digital footprints of CT technologists to analyze their workflow. We presented an overview of other digital footprints including but not limited to contrast administration, patient positioning, billing, reformat creation, and scheduling. A framework for analyzing image acquisition workflow was presented. This framework is transferable to any modality, as the key steps of image acquisition, image reconstruction, image post processing, and image transfer to PACS are common to any imaging modality in diagnostic radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmarking blockchain-based gene-drug interaction data sharing methods: A case study from the iDASH 2019 secure genome analysis competition blockchain track

Blockchain distributed ledger technology is just starting to be adopted in genomics and healthcare applications. Despite its increased prevalence in biomedical research applications, skepticism regarding the practicality of blockchain technology for real-world problems is still strong and there are few implementations beyond proof-of-concept. We focus on benchmarking blockchain strategies applied to distributed methods for sharing records of gene-drug interactions. We expect this type of sharing will expedite personalized medicine. We generated gene-drug interaction test datasets using the Clinical Pharmacogenetics Implementation Consortium (CPIC) resource. We developed three blockchain-based methods to share patient records on gene-drug interactions: Query Index, Index Everything, and Dual-Scenario Indexing. We achieved a runtime of about 60 s for importing 4,000 gene-drug interaction records from four sites, and about 0.5 s for a data retrieval query. Our results demonstrated that it is feasible to leverage blockchain as a new platform to share data among institutions.

60 APPLIED LIFE SCIENCES↗

Using Dynamic Quantum Clustering to Analyze Hierarchically Heterogeneous Samples on the Nanoscale

Dynamic Quantum Clustering (DQC) is an unsupervised, high visual data mining technique. DQC was tested as an analysis method for X-ray Absorption Near Edge Structure (XANES) data from the Transmission X-ray Microscopy (TXM) group. The TXM group images hierarchically heterogeneous materials with nanoscale resolution and large field of view. XANES data consists of energy spectra for each pixel of an image. It was determined that DQC successfully identifies structure in data of this type without prior knowledge of the components in the sample. Clusters and sub-clusters clearly reflected features of the spectra that identified chemical component, chemical environment, and density in the image. DQC can also be used in conjunction with the established data analysis technique, which does require knowledge of components present.

99 GENERAL AND MISCELLANEOUS↗

LOCAL NON-GAUSSIANITY IN THE COSMIC MICROWAVE BACKGROUND THE BAYESIAN WAY

We introduce an exact Bayesian approach to search for non-Gaussianity of local type in cosmic microwave background (CMB) radiation data. Using simulated CMB temperature maps, the newly developed technique is compared against the conventional frequentist bispectrum estimator. Starting from the joint probability distribution, we obtain analytic expressions for the conditional probabilities of the primordial perturbations given the data, and for the level of non-Gaussianity, f{sub NL}, given the data and the perturbations. We propose Hamiltonian Monte Carlo sampling as a means to derive realizations of the primordial fluctuations from which we in turn sample f{sub NL}. Although computationally expensive, this approach allows us to construct exactly the full target posterior probability distribution. When compared to the frequentist estimator, applying the Bayesian method to Gaussian CMB maps provides consistent results. For the analysis of non-Gaussian maps, however, the error bars on f{sub NL} do not show excess variance within the Bayesian framework. This finding is of particular relevance in the light of upcoming high-precision CMB measurements obtained by the Planck satellite mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Harmonizing tau positron emission tomography in Alzheimer's disease: The CenTauR scale and the joint propagation model

Abstract INTRODUCTION Tau‐positron emission tomography (PET) outcome data of patients with Alzheimer's disease (AD) cannot currently be meaningfully compared or combined when different tracers are used due to differences in tracer properties, instrumentation, and methods of analysis. METHODS Using head‐to‐head data from five cohorts with tau PET radiotracers designed to target tau deposition in AD, we tested a joint propagation model (JPM) to harmonize quantification (units termed “CenTauR” [CTR]). JPM is a statistical model that simultaneously models the relationships between head‐to‐head and anchor point data. JPM was compared to a linear regression approach analogous to the one used in the amyloid PET Centiloid scale. RESULTS A strong linear relationship was observed between CTR values across brain regions. Using the JPM approach, CTR estimates were similar to, but more accurate than, those derived using the linear regression approach. DISCUSSION Preliminary findings using the JPM support the development and adoption of a universal scale for tau‐PET quantification. Highlights Tested a novel joint propagation model (JPM) to harmonize quantification of tau PET. Units of common scale are termed “CenTauRs”. Tested a Centiloid‐like linear regression approach. Using five cohorts with head‐to‐head tau PET, JPM outperformed linearregressionbased approach. Strong linear relationship was observed between CenTauRs values across brain regions.

Neurosciences & Neurology↗