Volumetric additive manufacturing of silica glass with microscale computed axial lithography

Glass is increasingly desired as a material for manufacturing complex microscopic geometries, from the micro-optics in compact consumer products to microfluidic systems for chemical synthesis and biological analyses. As the size, geometric, surface roughness, and mechanical strength requirements of glass evolve, conventional processing methods are challenged. We introduce microscale computed axial lithography (micro-CAL) of fused silica components, by tomographically illuminating a photopolymer-silica nanocomposite that is then sintered. We fabricated three-dimensional microfluidics with internal diameters of 150 micrometers, free-form micro-optical elements with a surface roughness of 6 nanometers, and complex high-strength trusses and lattice structures with minimum feature sizes of 50 micrometers. As a high-speed, layer-free digital light manufacturing process, micro-CAL can process nanocomposites with high solids content and high geometric freedom, enabling new device structures and applications.

36 MATERIALS SCIENCE↗

A robust method of nuclei isolation for single-cell RNA sequencing of solid tissues from the plant genus Populus

Single-cell transcriptome analysis has been extensively applied in humans and animal models to uncover gene expression heterogeneity between the different cell types of a tissue or an organ. It demonstrated its capability to discover key regulatory elements that determine cell fate during developmental programs. Single-cell analysis requires the isolation and labeling of the messenger RNA (mRNA) derived from each cell. These challenges were primarily addressed in mammals by developing microfluidic-based approaches. For plant species whose cells contain cell walls, these approaches have generally required the generation of isolated protoplasts. Many plant tissues’ secondary cell wall hinders enzymatic digestion required for individual protoplast isolation, resulting in an unequal representation of cell types in a protoplast population. This limitation is especially critical for cell types located in the inner layers of a tissue or the inner tissues of an organ. Consequently, single-cell RNA sequencing (scRNA-seq) studies using microfluidic approaches in plants have mainly been restricted to Arabidopsis roots, for which well-established procedures of protoplast isolation are available. Here we present a simple alternative approach to generating high-quality protoplasts from plant tissue by characterizing the mRNA extracted from individual nuclei instead of whole cells. We developed the protocol using two different plant materials with varying cellular complexity levels and cell wall structure, Populus shoot apices, and more lignified stems. Using the 10× Genomics Chromium technology, we show that this procedure results in intact mRNA isolation and limited leakage, with a broad representation of individual cell transcriptomes.

54 ENVIRONMENTAL SCIENCES↗

Monitoring the impact of confinement on hyphal penetration and fungal behavior

Through their expansive mycelium network, soil fungi alter the physical arrangement and chemical composition of their local environment. This can significantly impact bacterial distribution and nutrient transport and can play a dramatic role in shaping the rhizosphere around a developing plant. However, direct observation and quantitation of such behaviors is extremely difficult due to the opacity and complex porosity of the soil microenvironment. In this study, we demonstrate the development and use of an engineered microhabitat to visualize fungal growth in response to varied levels of confinement. Microfluidics were fabricated using photolithography and conventional soft lithography, assembled onto glass slides, and prepared to accommodate fungal cultures. Selected fungal strains across three phyla (Ascomycota: Morchella sextalata , Fusarium falciforme ; Mucoromycota: Linnemannia elongata , Podila minutissima , Benniella ; Basidiomycota: Laccaria bicolor , and Serendipita sp.) were cultured within microhabitats and imaged using time-lapse microscopy to visualize development at the mycelial level. Fungal hyphae of each strain were imaged as they penetrated through microchannels with well-defined pore dimensions. The hyphal penetration rates through the microchannels were quantified via image analysis. Other behaviors, including differences in the degree of branching, peer movement, and tip strength were also recorded for each strain. Our results provide a repeatable and easy-to-use approach for culturing fungi within a microfluidics platform and for visualizing the impact of confinement on hyphal growth and other fungal behaviors pertinent to their remodeling of the underground environment.

Guo, Yi-Syuan (ORCID:0000000340142225)↗

Preliminary characterization of active MEMS valves.

Partial characterization of a series of electrostatically actuated active microfluidic valves is to be performed. Tests are performed on a series of 24 valves from two different MEMS sets. Focus is on the physical deformation of the structures under variable pressure loadings, as well as voltage levels. Other issues that inhibit proper performance of the valves are observed, addressed and documented as well. Many microfluidic applications have need for the distribution of gases at finely specified pressures and times. To this end a series of electrostatically actuated active valves have been fabricated. Eight separate silicon die are discussed, each with a series of four active valves present. The devices are designed such that the valve boss is held at a ground, with a voltage applied to lower contacts. Resulting electrostatic forces pull the boss down against a series of stops, intended to create a seal as well as prevent accidental shorting of the device. They have been uniquely packaged atop a stack of material layers, which have inlaid channels for application of fluid flow to the backside of the valve. Electrical contact is supplied from the underlying printed circuit board, attached to external supplies and along traces on the silicon. Pressure is supplied from a reservoir of house compressed air, up to 100 Psig. This is routed through a Norgren R07-200-RGKA pressure regulator, rated to 150 Psig. From there flow passes a manually operated ball valve, and to a flow meter. Two flow meters were utilized; initially an Omega FMA1802 rated at 10 sccm, and followed by a Flocat model for higher flow rates up to 100 sccm. An Omega DPG4000-500 pressure gauge produced pressure measurements. Optical measurements were returned via a WYKO Interferometry probe station. This would allow for determination of physical deformations of the device under a variety of voltage and pressure loads. This knowledge could lead to insight as to the failure mechanisms of the device, yielding improvements for subsequent fabrications.

47 OTHER INSTRUMENTATION↗

Electrostatic microvalves utilizing conductive nanoparticles for improved speed, lower power, and higher force actuation.

We have designed and built electrostatically actuated microvalves compatible with integration into a PDMS based microfluidic system. The key innovation for electrostatic actuation was the incorporation of carbon nanotubes into the PDMS valve membrane, allowing for electrostatic charging of the PDMS layer and subsequent discharging, while still allowing for significant distention of the valveseat for low voltage control of the system. Nanoparticles were applied to semi-cured PDMS using a stamp transfer method, and then cured fully to make the valve seats. DC actuation in air of these valves yielded operational voltages as low as 15V, by using a supporting structure above the valve seat that allowed sufficient restoring forces to be applied while not enhancing actuation forces to raise the valve actuation potential. Both actuate to open and actuate to close valves have been demonstrated, and integrated into a microfluidic platform, and demonstrated fluidic control using electrostatic valves.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improved Production and Separation Technologies for Non-standard PET Radionuclides

Brief summary of activity issues, concerns, successes: Project 1 is completed. We have optimized plating parameters with the new target bodies and slanted target plating system. The target station has been mounted on the end of the beamline, service lines have been Installed to allow for helium and water cooling. We have routinely produced copper-64 using the new slanted target system in conjunction with our automated system. In project 2, we successfully fabricated and tested microfluidic extraction devices made out of two organic solvent-resistant polymers, thiolene and SIFEL. Initially, we developed analytical and computational models to describe the extraction process, and used the model to design the microfluidic devices. Then we optimized the microfabrication procedures to manufacture microreactors, followed by optimization of the operational parameters to obtain a stable aqueous-organic interface, which is critical for efficient extraction. When we tested the thiolene devices for extraction of copper-64, we observed very low extraction efficiencies (less than 5%) due to adhesion of copper to thiolene. However, we observed very high extraction efficiencies with SIFEL devices (greater than 95%), which are due to the high interfacial area for extraction and shorter diffusion lengths.

07 ISOTOPE AND RADIATION SOURCES↗

Genomics-enabled sensor platform for rapid detection of viruses related to disease outbreak.

Bioweapons and emerging infectious diseases pose growing threats to our national security. Both natural disease outbreak and outbreaks due to a bioterrorist attack are a challenge to detect, taking days after the outbreak to identify since most outbreaks are only recognized through reportable diseases by health departments and reports of unusual diseases by clinicians. In recent decades, arthropod-borne viruses (arboviruses) have emerged as some of the most significant threats to human health. They emerge, often unexpectedly, from cryptic transmission foci causing localized outbreaks that can rapidly spread to multiple continents due to increased human travel and trade. Currently, diagnosis of acute infections requires amplification of viral nucleic acids, which can be costly, highly specific, technically challenging and time consuming. No diagnostic devices suitable for use at the bedside or in an outbreak setting currently exist. The original goals of this project were to 1) develop two highly sensitive and specific diagnostic assays for detecting RNA from a wide range of arboviruses; one based on an electrochemical approach and the other a fluorescent based assay and 2) develop prototype microfluidic diagnostic platforms for preclinical and field testing that utilize the assays developed in goal 1. We generated and characterized suitable primers for West Nile Virus RNA detection. Both optical and electrochemical transduction technologies were developed for DNA-RNA hybridization detection and were implemented in microfluidic diagnostic sensing platforms that were developed in this project.

Brozik, Susan M↗

Microbiological-enhanced mixing across scales during in-situ bioreduction of metals and radionuclides at Department of Energy Sites

Bioreduction is being actively investigated as an effective strategy for subsurface remediation and long-term management of DOE sites contaminated by metals and radionuclides (i.e. U(VI)). These strategies require manipulation of the subsurface, usually through injection of chemicals (e.g., electron donor) which mix at varying scales with the contaminant to stimulate metal reducing bacteria. There is evidence from DOE field experiments suggesting that mixing limitations of substrates at all scales may affect biological growth and activity for U(VI) reduction. Although current conceptual models hold that biomass growth and reduction activity is limited by physical mixing processes, a growing body of literature suggests that reaction could be enhanced by cell-to-cell interaction occurring over length scales extending tens to thousands of microns. Our project investigated two potential mechanisms of enhanced electron transfer. The first is the formation of single- or multiple-species biofilms that transport electrons via direct electrical connection such as conductive pili (i.e. ‘nanowires’) through biofilms to where the electron acceptor is available. The second is through diffusion of electron carriers from syntrophic bacteria to dissimilatory metal reducing bacteria (DMRB). The specific objectives of this work are (i) to quantify the extent and rate that electrons are transported between microorganisms in physical mixing zones between an electron donor and electron acceptor (e.g. U(IV)), (ii) to quantify the extent that biomass growth and reaction are enhanced by interspecies electron transport, and (iii) to integrate mixing across scales (e.g., microscopic scale of electron transfer and macroscopic scale of diffusion) in an integrated numerical model to quantify these mechanisms on overall U(VI) reduction rates. We tested these hypotheses with five tasks that integrate microbiological experiments, unique micro-fluidics experiments, flow cell experiments, and multi-scale numerical models. Continuous fed-batch reactors were used to derive kinetic parameters for DMRB, and to develop an enrichment culture for elucidation of syntrophic relationships in a complex microbial community. Pore and continuum scale experiments using microfluidic and bench top flow cells were used to evaluate the impact of cell-to-cell and microbial interactions on reaction enhancement in mixing-limited bioactive zones, and the mechanisms of this interaction. Some of the microfluidic experiments were used to develop and test models that considers direct cell-to-cell interactions during metal reduction. Pore scale models were incorporated into a multi-scale hybrid modeling framework that combines pore scale modeling at the reaction interface with continuum scale modeling. New computational frameworks for combining continuum and pore-scale models were also developed

54 ENVIRONMENTAL SCIENCES↗

Advanced Diagnostic and Sample Preparation Platform for Early Threat Surveillance

Emerging infectious diseases present a profound threat to global health, economic development, and political stability, and therefore represent a significant national security concern for the United States. The increased prevalence of international travel and globalized trade further amplify the threat of infectious disease outbreaks of catastrophic effect. The key to containing and eradicating an outbreak before it goes global is rapid identification of index cases and initial clusters of affected individuals. This depends upon establishment of a biosurveillance network that effectively reaches infectious disease hotspots in even the most remote regions of the world and provides a network-integrated, location-appropriate diagnostic capability. At present, there are two critical needs which must be addressed in order to extend biosurveillance activities beyond centralized laboratory facilities: 1) A simple, reliable, and safe method for immediate stabilization of clinical specimens in the field; and 2) A flexible sample processing platform that enables in-field preparation of clinical specimens for rapid, on-site analysis using a variety of diagnostic assay platforms. These needs are not necessarily mutually exclusive; in fact, we propose that they are most efficiently addressed by a deployable sample processing platform that immediately stabilizes the information content of clinical specimens through transformation of the inherently unstable analytes of interest into stable equivalents that are appropriately formatted for downstream analysis. In order to address this problem, we have developed a sample processing pipeline and microfluidics-based platform modules enabling: 1) Extraction of total RNA from finger-stick quantities of human whole blood; and 2) Microscale synthesis of appropriately-formatted cDNA products that capture the information content of blood RNA in a stable form that supports pathogen detection and/or characterization via PCR and/or Second Generation Sequencing (SGS). Through this research we have discovered new, effective solutions for problems that thus far have hindered use of digital microfluidics (DMF) in biomedical applications. Our work reveals a clear path forward to fieldable, automated sample processing systems that will enable rapid, on-site identification of usual-suspect and novel pathogens in clinical specimens for improved biosurveillance.

59 BASIC BIOLOGICAL SCIENCES↗

Hybrid Encapsulated Ionic Liquids for Post-Combustion Carbon Dioxide (CO 2 ) Capture

It is increasingly clear that carbon dioxide (CO 2 ) capture and sequestration (CCS) must play a critical role in curbing worldwide CO 2 emissions to the atmosphere. Previously, we have developed ionic liquids (ILs) and phase change ionic liquids (PCILs) for post-combustion CO 2 capture. In this project, we synthesized and tested 19 ILs and PCILs and chose one of each for further development. The IL selected for further development was triethyl(octyl)phosphonium 2-cyanopyrrolide ([P 2228 ][2CNPyr]), which has the same anion but a different cation, than used in our previous work. The new cation imparts a lower viscosity than the prior cation. The PCIL selected for further development was tetraethylphosphonium benzimidazolide ([P 2222 ][BnIm]), which was developed in an Advanced Research Projects Agency-Energy (ARPA-E) project. Although we made numerous other candidates, none were better than this original PCIL. Here we showed that the CO 2 absorption by the IL and the PCIL was completely reversible, even when water was present. We determined and quantified the additional chemistry, involving the formation of bicarbonate, when water is present. The IL and PCIL were encapsulated in silicone shells using a microfluidic device. Compatibility between the IL/PCIL and the polymer, viscosity, and surface tension issues, getting sufficiently high IL/PCIL loading and leakage (likely from insufficient cross-linking), were serious challenges. Small quantities (~ 1 g) of microcapsules with good integrity of both the IL and the PCIL were produced. The CO 2 uptake by these capsules was the same as for the free IL and PCIL and the capacity of the capsules decreased only slightly even after five absorption and desorption cycles. As expected, the IL and PCIL (and subsequently the encapsulated IL and PCIL) reacted readily with SO 2 and NO, so, like aqueous amine absorbents, the CO 2 capture unit would have to be located downstream of the flue gas desulfurization and other gas treatment units. Large samples (~70 g and 100 g) of encapsulated PCIL were produced in a parallel microfluidic device and in an in-air device. These capsules were tested in a Laboratory Scale Unit (LSU) to demonstrate uptake capacity in a fluidized bed. We also used the LSU to determine recyclability and mass transfer coefficients. Unfortunately, equivalent experiments with the IL were not possible due to difficulties with producing large samples of the encapsulated IL. This IL encapsulation “scale-up” problem was not solved during the course of this project. Nonetheless, using the PCIL microcapsules we demonstrated that, as expected, the mass transfer is internally controlled. In concert with a new rate-based model of the fluidized bed, we determined that the productivity is increased by a factor of 4.75 in the microcapsule fluidized bed absorber compared to a conventional liquid-gas packed bed absorber. The initial technoeconomic model shows that the capital cost for the microcapsule IL continuous fluidized bed process is similar to that of an aqueous amine process (specifically, the Econamine FG Plus technology). However, the stripping heat requirements are about 35% less for the model IL microcapsule case compared to the monoethanolamine (MEA) case. Thus, encapsulated ILs/PCILs in a continuous fluidized bed absorber for post-combustion CO 2 capture are a significant improvement over the free IL/PCIL case and represent a major reduction in the parasitic energy requirements compared to aqueous amine process.

20 FOSSIL-FUELED POWER PLANTS↗

A Handheld Medical Diagnostic Device for Harsh Environments

Medical diagnostic capabilities for extreme environments, are currently limited in nature to single marker type assays. We propose to develop a handheld device for medical diagnostics in extreme environments that provide sensitive and specific detection of biomarkers with an emphasis initially on radiation exposure. Such a device will have multiple uses, and will be easily adaptable to many applications. For example, first responders, the battlefield, in low resource settings in developing countries facing emerging disease outbreaks, and during long-duration space flights. To this end, we will develop highly adaptable microfluidic devices (cards) for profiling different biomarkers with an emphasis on those related to radiation exposure. We will leverage the previous centrifugal separator work from LLNL and Sandia National Laboratory. The radiation exposure biomarker work at LLNL will provide a biological platform for demonstrating the utility of the device. We will develop a fluidic system using a pump-less mechanical method (centrifugal) to move, control, order and layer fluids in the platform. This decreases complexity, while enabling simultaneous cell separation and plasma generation for two uses: the first is differential blood cell counts and the second is biomarker assay panels. This work will be accomplished in three Aims: Aim 1) Test multiplex microfluidic cards and integrated reader. Aim 2) Demonstrate system capabilities to take and process blood samples for multi-endpoint analysis. Aim 3) Test multiplex detection based on measuring differential blood cell counts, while measuring plasma protein biomarkers. The proposed work addresses the mission research challenge of chemical and biological countermeasure in that our work aims to provide new research capabilities to respond to man-made or natural outbreaks of pandemic diseases in particular in low resource and triage environments.

60 APPLIED LIFE SCIENCES↗

High throughput single cell multiomics platform [Abstract]

In this collaborative project, PNNL and Scienion will co-develop an integrated microfluidic technology to co-measure the transcriptome and proteome in single cells. The technology will enable us to efficiently separate proteins from mRNA transcripts between two microchips, barcode the molecules, and measure them separately with next-generation sequencing and mass spectrometry, respectively. Multicellular organisms contain diverse cell types and tremendous cell-to-cell heterogeneity that dictates a multitude of biological functions in both physiological and pathological environments. Even in the case of microbes, these genetically identical organisms can randomly differentiate into many subpopulations that assume different roles for the survival of the community. Bulk-scale measurements are insufficient to resolve such complexities. The development and applications of high throughput single-cell omics technologies have transformed our understanding of cellular heterogeneities and their differential responses to internal signaling events or external stimulations. Despite these advances, most current single-cell omic technologies provide information on only one type of biomolecule. Perse, such measurements provide incomplete information because the cell phenotype is determined by multiple layers of biomolecules and the interplay between genome, epigenome, transcriptome, and proteome. For example, mRNA abundance in one cell can not be precisely referred to the corresponding DNA and protein in other cells because of the potential subtle difference in genotype (e.g., somatic mutation or copy number variation) or phenotype (external microenvironment and cell-cell interactions). As such, parallel measurement of multiple biomolecules in the same single cells can offer unique advantages compared with measuring them separately in different single cells. Scienion is a world-leading biotech company focusing on precision liquid handling and its application in single-cell whole-genome sequencing and RNA sequencing. PNNL is the leading institution in ultrasensitive mass spectrometry, microfluidics, and untargeted single-cell proteomics (scProteomics). This collaboration will facilitate a unique fusion between scTranscriptomics capability at Scienion and scProteomics capabilities at PNNL to, for the first time, perform both untargeted transcriptomics and proteomics from the same single cells.

59 BASIC BIOLOGICAL SCIENCES↗

Kinetics and Mechanism of Tetravalent Cerium Extraction by Di-2-Ethylhexyl Isobutyramide (DEHiBA)

DEHiBA is a fully-incinerable, CHON extractant with a high selectivity for hexavalent actinides. However, as a recently-developed ligand, much remains unknown about its physical and chemical properties, including its extraction and phase disengagement rates. Here, we present data on the phase transfer kinetics of Ce(IV) extraction and stripping by both DEHiBA and TBP collected using microfluidic devices. Ce(IV) was selected as a surrogate for Pu(IV) and Np(IV) in the initial tests of the microfluidics system prior to testing with the actinides. Pseudo first-order reaction rate constants are determined for both systems, and the corresponding Damköhler numbers (Da) are calculated to establish whether the extraction and stripping processes are kinetically or diffusion controlled. The stoichiometry of the extracted Ce(IV)-DEHiBA complex is determined, and the phase disengagement properties under extraction conditions are assessed using the dimensionless dispersion number. A possible explanation for the favorable extraction of Ce(IV) by DEHiBA, which is known to poorly extract many tetravalent cations, is presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Out of the Lab: 3D Printing on Non-Ideal Surfaces

In this work, coaxial direct ink writing is utilized to print sensitive or encapsulated materials onto heterogeneous and rough substrates. By enclosing the core fluid within a rigid ceramic shell, continuity is maintained even when printing on substrates traditionally considered challenging. This work presents the development of a coaxial ceramic direct ink writing system and investigates co-flow dynamics through microfluidic principles. A specially designed coaxial nozzle enables the co-extrusion of an alumina shell, with indium-tin-oxide inks serving as the core material. This approach allows the fabrication of core-shell ceramic structures suitable for future high-temperature applications on rough surfaces. The colloidal inks are tailored to achieve the necessary rheological properties and sintering performance. Additionally, flow simulations, guided by microfluidic co-flow principles, are employed to define the processing parameters for coaxial printing, ensuring precise control over the core-shell architectures. Physical modeling is further applied to study core deformation and eccentricity. These simulations are experimentally validated, supporting the successful deposition of coaxial ceramic features on heterogeneous, high-temperature ceramic substrates.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluating Polymer Properties with Different Additives for Carbon Capture and Other Applications

Anthropogenic climate change is one of this generation’s most pressing concerns, with the potential to completely alter the delicate balance we’ve struck with nature. Already, global temperatures have risen 1.29°C, leading to disrupted weather systems, extinctions, increased risks of wildfires, and sea level rise, to name a few effects. Carbon dioxide emission from the combustion of fossil fuels and other industrial activity is a large driver of this phenomenon, as it absorbs heat before it can be radiated away from Earth, trapping it. Carbon dioxide has reached unprecedented levels in our atmosphere, showing a 50% increase from preindustrial averages to a whopping 430 ppm. Thus, reducing the amount of carbon dioxide via carbon capture technology is an important endeavor that serves to benefit everyone. The Microencapsulated CO 2 Sorbent (MECS) team at Lawrence Livermore National Laboratory (LLNL) has turned to microencapsulation to approach this endeavor. Microcapsules provide an attractive approach to carbon capture, combining large surface areas for more efficient mass transfer, regenerative abilities, reduced solvent loss, and improved handling. Additionally, while existing carbon capture technology relies on industrial plants, capsules could present a modular approach to carbon capture, reducing the need for extensive physical infrastructure. The MECS team’s design consists of a polymer membrane that contains a liquid carbon sequestering sorbent, aqueous sodium carbonate. The carbon capturing reaction occurs in three distinct steps, the first of which is the dissolution of carbon dioxide into the sorbent solution and its conversion into carbonic acid (H 2 CO 3 ), shown in equations 1 and 2 respectively. Because this step hinges upon the ability of carbon dioxide to reach the solution inside the capsule, it is necessary that the microcapsule shell is permeable to carbon dioxide gas. The MECS team produces these microcapsules using the in-air droplet encapsulation apparatus (IDEA) shown in figure 1, which can produce uniform micron-scale droplets at speeds much faster than traditional single-dispersal microfluidic-based techniques. The IDEA Is 100 times faster than these current techniques and can reach up to 1000 times their speed when incorporating a multi-nozzle design. Additionally, because droplets are produced in-air via vibration, IDEA can decrease post-processing times and material waste by 99% and can fabricate microgels that are 10 to 100 times more viscous than can be produced via traditional microfluidics. While this design represents a breakthrough in the throughput, efficiency, and tunability of microcapsule production, it imposes a major constraint on the microcapsule curing process. Because microcapsule shells are crosslinked with UV light while falling 30 cm through the air, this gives them a reaction window of approximately 0.2 seconds. Thus, the system and shell formulations must be optimized such that the shells can be fully crosslinked within this very narrow window, prompting investigations into curing behavior.

36 MATERIALS SCIENCE↗

Molecular Aspects of Transport in Thin Films of Controlled Architecture

Our laboratory focuses on developing spatially localized chemistries which can produce structures of controlled architecture on the supermolecular length scale -- structures which allow us to control the motion of molecular species with high spatial resolution, ultimately on nanometer length scales. Specifically, nanocapillary array membranes (NCAMs) contain an array of nanometer diameter pores connecting vertically separated microfluidic channels. NCAMs can manipulate samples with sub-femtoliter characteristic volumes and attomole sample amounts and are opening the field of chemical analysis of mass-limited samples, because they are capable of digital control of fluid switching down to sub-attoliter volumes; extension of analytical “unit operations” down to sub-femtomole sample sizes; and exerting spatiotemporal control over fluid mixing to enable studies of reaction dynamics. Digital flow switching mediated by nanocapillary array membranes can be controlled by bias, ionic strength, or pore diameter and is being studied by observing the temporal characteristics of transport across a single nanopore in thin PMMA membranes. The control of flow via nanopore surface characteristics, charge density and functional group presentation, is being studied by coupled conductivity and laser-induced fluorescence (LIF) measurements. Reactive mixing experiments previously established low millisecond mixing times for NCAM-mediated fluid transfer, and this has been exploited to demonstrate capture of mass-limited target species by Au colloids. Voltage and thermally-activated polymer switches have been developed for active control of transport in NCAMs. Thermally-switchable and size-selective transport was achieved by grafting poly(N-isopropylacrylamide) brushes onto the exterior surface of a Au-coated polycarbonate track-etched membrane, while the voltage-gated properties of poly(hydroxyethylmethacrylate) were characterized dynamically. Electrophoretic separations have been coupled to analyte sampling both by LIF and mass spectrometry. Detection of electrophoresis separation products by electrospray mass spectrometry was achieved through direct interfacing to an electrospray mass spectrometer. Pb(II) interactions with the DNAzyme have been realized in an NCAM-coupled integrated microfluidic structure allowing cation separations to be coupled to molecular beacon detection motifs for the determination of Pb(II) in an electroplating sludge reference material. By changing the DNAzyme to select for other compounds of interest, it is possible to incorporate multiple sensing systems within a single device, thereby achieving great flexibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reducing the matrix effect in mass spectral imaging of biofilms using flow-cell culture

The interactions between soil microorganisms and soil minerals play a crucial role in the formation and evolution of minerals and the stability of soil aggregates. Due to the heterogeneity and diversity of the soil environment, the under-standing of the functions of bacterial biofilms in soil minerals at the microscale is limited. A soil mineral-bacterial biofilm system was used as a model in this study, and it was analyzed by time-of-flight secondary ion mass spectrometry (ToF-SIMS) to acquire molecular level information. Static culture in multi-wells and dynamic flow-cell culture in microfluidics of biofilms were investigated. Our results show that more characteristic molecules of biofilms can be observed in SIMS spectra of the flow-cell culture. In contrast, biofilm signature peaks are buried under the mineral components in SIMS spectra in the static culture case. Spectral overlay was used in peak selection prior to performing Principal component analysis (PCA). Comparisons of the PCA results between the static and flow-cell culture show more pronounced molecular features and higher loadings of organic peaks of the dynamic cultured specimens. For example, fatty acids secreted from bacterial biofilm extracellular polymeric substance are likely to be responsible for biofilm dispersal due to mineral treatment up to 48 h. Such findings suggest that the use of microfluidic cells to dynamically culture biofilms be a more suitable method for reducing the matrix effect arisen from the growth medium and minerals as a perturbation fac-tor for improved spectral and multivariate analysis of complex mass spectral data in ToF-SIMS. These results show that the interaction mechanism between biofilms and soil minerals at the molecular level can be better studied using the flow-cell culture and advanced mass spectral imaging techniques like ToF-SIMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro-Detection System for Determination of the Biotic or Abiotic Origin of Amino Acids

The research carried out under this PIDDP involves the development of a breadboard version of a spacecraft-based system for the detection of amino acid chirality (molecular handedness) on solar system bodies. Chirality provides an unambiguous way of distinguishing between abiotic and biotic origins since only one mirror-image form is used in the functional molecules of life. Recent advances in a variety of nano-fabrication technologies have resulted in concepts for enabling miniaturized chemical and biological analytical systems. These are complete application-specific systems that integrate fluid micro handling systems for extracting and reacting target molecules, micro-separation technologies for enhanced sensitivity and resolution, and advanced detection technologies. This effort makes use of a relatively new technology that shows demonstrated promise for spacecraft-based amino acid analysis: microchip-based capillary electrophoresis (μCE). The μCE system is capable of analyzing the type of amino acids present as well as the relative amounts of their mirror image forms. The system we developed will be able to chirally resolve all of the major amino acids found in extraterrestrial material (Gly, Ala, Val, Pro, Asp, Glu, a-aminoisobutyric acid, and isovaline) at sub-part-per-billion levels. The -CE analysis requires that the amino acids be extracted from the sample and derivatized for either optical or electrochemical detection. In our implementation, the amino acids are released from the sample by sublimation and prepared for μCE analysis using a microfluidic circuit. In addition, we have investigated the use of a microfluidic circuit for the release of amino acids from samples in which sublimation has proven to be problematic.