Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microstrip”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Neutron Transfer Reactions on Neutron-Rich N = 50 and N = 82 Nuclei Near the r-Process Path

Neutron transfer (d,p) reaction studies on the N = 50 isotones, {sup 82}Ge and {sup 84}Se, and A{approx_equal}130 nuclei, {sup 130,132}Sn and {sup 134}Te, have been measured. Direct neutron capture cross sections for {sup 82}Ge and {sup 84}Se (n,{gamma}) have been calculated and are combined with Hauser-Feshbach expectations to estimate total (n,{gamma}) cross sections. The A{approx_equal}130 studies used an early implementation of the ORRUBA array of position-sensitive silicon strip detectors for reaction proton measurements. Preliminary excitation energy and angular distribution results from the A{approx_equal}130 measurements are reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

STAR Vertex Detector Upgrade-HFT Pixel Development

Development and prototyping efforts directed towards construction of a new vertex detector for the STAR experiment at the RHIC accelerator at BNL are presented. This new detector will extend the physics range of STAR by allowing for precision measurements of yields and spectra of particles containing heavy quarks. The innermost central part of the new detector is a high resolution pixel-type detector (PIXEL). PIXEL requirements are discussed as well as a conceptual mechanical design, a sensor development path, and a detector readout architecture. Selected progress with sensor prototypes dedicated to the PIXEL detector is summarized and the approach chosen for the readout system architecture validated in tests of hardware prototypes is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Elemental Discrimination of Low-Energy Ions using Risetime Analysis of Silicon-Strip Detector Signals

To make measurements with the intense (but often contaminated) radioactive beams available today, one often needs to identify the reaction products to determine the events of interest. The low energies required for many astrophysics measurements make impossible the use of traditional energy loss techniques, and additional constraints are required. We demonstrate a simple technique to measure the risetimes of silicon strip-detector signals and show partial discrimination can be obtained even at energies below 1 MeV/u.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon Detectors-Tools for Discovery in Particle Physics

Since the first application of Silicon strip detectors in high energy physics in the early 1980ies these detectors have enabled the experiments to perform new challenging measurements. With these devices it became possible to determine the decay lengths of heavy quarks, for example in the fixed target experiment NA11 at CERN. In this experiment Silicon tracking detectors were used for the identification of particles containing a c-quark. Later on, the experiments at the Large Electron Positron collider at CERN used already larger and sophisticated assemblies of Silicon detectors to identify and study particles containing the b-quark. A very important contribution to the discovery of the last of the six quarks, the top quark, has been made by even larger Silicon vertex detectors inside the experiments CDF and D0 at Fermilab. Nowadays a mature detector technology, the use of Silicon detectors is no longer restricted to the vertex regions of collider experiments. The two multipurpose experiments ATLAS and CMS at the Large Hadron Collider at CERN contain large tracking detectors made of Silicon. The largest is the CMS Inner Tracker consisting of 200 m{sup 2} of Silicon sensor area. These detectors will be very important for a possible discovery of the Higgs boson or of Super Symmetric particles. This paper explains the first applications of Silicon sensors in particle physics and describes the continuous development of this technology up to the construction of the state of the art Silicon detector of CMS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarized Proton-Proton Elastic Scattering at RHIC

The Relativistic Heavy Ion Collider provides colliding polarized proton beams of 25 to 250 GeV/c momentum. With silicon strip detectors installed in Roman Pots at about 58 m on either side of the interaction point (IP) of the STAR detector, elastic scattering will be studied at a center of mass (cms) energy of 200 GeV and four momentum transfer squared range of 0.003 GeV{sup 2}/c{sup 2}<=|t|<=0.03 GeV{sup 2}/c{sup 2}, with 100% acceptance and full phi coverage. Measurements of single and double spin asymmetries will be carried out with special beam optics. An upgrade with additional Roman pots closer to the IP will increase the kinematic range to |t|<=1.5 GeV{sup 2}/c{sup 2} at sq root(s) = 500 GeV. Simulation studies of the detector acceptance for 200 GeV cms energy will be given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The RHIC p-Carbon CNI Polarimeter Upgrade For The Beam Polarization And Intensity Measurements

Proton polarization measurements in the AGS and RHIC (Relativistic Heavy Ion Collider at the beam energies 24-250 GeV) are based on proton-carbon and proton-proton elastic scattering in the Coulomb Nuclear Interference (CNI) region. Polarimeter operation in the scanning mode also gives polarization profile and beam intensity profile (beam emittance) measurements. Bunch by bunch emittance measurement is a very powerful tool for machine setup. Presently, the polarization and beam intensity profile measurements (in both vertical and horizontal planes) are restricted by the long target switching time and possible target destruction during this complicated motion. The RHIC polarimeters were operated near the limit of the counting rate for present silicon strip detectors. The ongoing polarimeter upgrade for the 2009 run will address all these problems. The upgrade should allow significant reduction of the polarization measurement errors by making feasible the complete polarization measurements, which includes polarization profiles in both the horizontal and vertical planes.

43 PARTICLE ACCELERATORS↗

Two-proton Emission from {sup 29}S and {sup 17}Ne Excited States via Coulomb Excitation

The experiments of two-proton emission from {sup 29}S and {sup 17}Ne excited levels were performed at HIRFL-RIBLL facility of Institute of Modern Physics, Lanzhou. Complete kinematics measurements were achieved by the detectors of silicon strip and CsI+PIN array after the {sup 197}Au target. The preliminary results show the strong correlation of two protons according to the spectrum of correlated proton-proton energies in the laboratory reference frame.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectroscopy of {sup 16}O Using {alpha}+{sup 12}C Resonant Scattering in Inverse Kinematics

A measurement of the {alpha}({sup 12}C,{alpha}){sup 12}C reaction has been performed using resonant scattering with a gas target. Beam energies of 46, 51, 56 and 63 MeV were used to populate resonances in the excitation energy range of 11.6 to 22.9 MeV in {sup 16}O. The angular distributions of the elastic scattering were measured at zero degrees using an array of segmented silicon strip detectors with a minimum range of 0 deg. to 30 deg. in the centre of mass. The spins of 8 resonances between 14.1 and 18.5 MeV were obtained, confirming spin assignments made using elastic scattering in normal kinematics. An R-matrix analysis of the data was performed which indicates that the present understanding of {sup 16}O in this region is good, but not complete.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron Reconstruction and Identification with the ATLAS Detector

Several Standard Model processes contain electrons in the final state. Also, many signatures expected from physics beyond the Standard Model include one or more electrons. This paper describes the electron reconstruction along with some of the identification criteria used in the ATLAS detector. The expected performance at the start-up of the experiment are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Very Low Energy Protons From the Beta Decay of Proton Rich Nuclei For Nuclear Astrophysics

We have developed a new experimental technique to measure very low energy protons from beta-delayed p-decay of proton-rich nuclei produced and separated with the MARS recoil spectrometer at TAMU. Recently we have investigated the beta-delayed p-decays of {sup 23}Al and {sup 31}Cl and obtained information on the resonances in the reactions {sup 22}Na(p,gamma){sup 23}Mg and {sup 30}P(p,gamma){sup 31}S, respectively. These reactions are important in explosive H-burning in Novae. A simple setup consisting of a telescope made of a thin double sided Si strip detector (p-detector) backed or sandwiched between two thick Si detectors (beta-detectors) was designed. We studied two different p-detectors and found that the thinner detectors with a small cell size are best to measure proton energies as low as 2-300 keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Active Correlation Technique: Status and Development

During the recent years, at the FLNR (JINR) a successful cycle of experiments has been accomplished on the synthesis of the superheavy elements with Z = 112-118 with {sup 48}Ca beam. From the viewpoint of the detection of rare decays and background suppression, this success was achieved due to the application of a new radical technique--the method of active correlations. The method employs search in a real-time mode for a pointer to a probable correlation like recoil-alpha for switching the beam off. In the case of detection in the same detector strip an additional alpha-decay event, of 'beam OFF' time interval is prolonged automatically.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anomalous behaviour of DSSSDs

Double Sided Silicon Strip Detectors (DSSSDs) are often used in nuclear physics experiments in a wide energy range. According to the previous experiments, when a particle hits the interstrip region of these detectors, different effects may occur. Charge sharing, pulse height deficits and inverse polarity pulses on adjacent strips can influence the measured charge. In order to understand these effects and improve DSSSD utilization, an experiment was performed at the scanning proton microbeam of the Ruder Boskovic Institute (RBI) using low proton microbeam intensity ({approx}fA) and two DSSSDs of thickness 75 {mu}m and 998 {mu}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

β-decay spectroscopy for the r-process nucleosynthesis

Series of decay spectroscopy experiments, utilizing of high-purity Ge detectors and double-sided silicon-strip detectors, have been conducted to harvest the decay properties of very exotic nuclei relevant to the r-process nucleosynthesis at the RIBF. The decay properties such as β-decay half-lives, low-lying states, β-delayed neutron emissions, isomeric states, and possibly Q{sub β} of the very neutron-rich nuclei are to be measured to give significant constraints in the uncertainties of nuclear properties for the r-process nucleosynthesis. Recent results of βγ spectroscopy study using in-flight fission of {sup 238}U-beam will be presented together with our future perspectives.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results of the 2015 testbeam of a 180 nm AMS High-Voltage CMOS sensor prototype

We investigated the active pixel sensors based on the High-Voltage CMOS technology as a viable option for the future pixel tracker of the ATLAS experiment at the High-Luminosity LHC. Our paper reports on the testbeam measurements performed at the H8 beamline of the CERN Super Proton Synchrotron on a High-Voltage CMOS sensor prototype produced in 180 nm AMS technology. These results in terms of tracking efficiency and timing performance, for different threshold and bias conditions, are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hardness studies of AMS HV-CMOS 350 nm prototype chip HVStripV1

CMOS active pixel sensors are being investigated for their potential use in the ATLAS inner tracker upgrade at the HL-LHC. The new inner tracker will have to handle a significant increase in luminosity while maintaining a sufficient signal-to-noise ratio and pulse shaping times. This paper focuses on the prototype chip "HVStripV1" (manufactured in the AMS HV-CMOS 350nm process) characterization before and after irradiation up to fluence levels expected for the strip region in the HL-LHC environment. The results indicate an increase of depletion region after irradiation for the same bias voltage by a factor of ≈2.4 and ≈2.8 for two active pixels on the test chip. As a result, there was also a notable increase in noise levels from 85 e – to 386 e – and from 75 e – to 277 e – for the corresponding pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new strips tracker for the upgraded ATLAS ITk detector

The ATLAS detector has been created and determined to function in the environment of the present Large Hadron Collider (LHC). At the next-generation tracking detector proposed for the High Luminosity LHC (HL-LHC), the so-called ATLAS Phase-II Upgrade, the fluences and radiation levels will be higher by as much as a factor of ten. The new sub-detectors must thus be faster, of larger area, more segmented and more radiation hard while the amount of inactive material should be minimized and the power supply to the front-end systems should be increased. For those reasons, the current inner tracker of the ATLAS detector will be fully replaced by an all-silicon tracking system that consists of a pixel detector at small radius close to the beam line and a large area strip tracker surrounding it. This report gives an overview of the design of the strip inner tracker (Strip ITk) and summarises the intensive R&D activities performed over the last years by the numerous institutes within the Strips ITk collaboration. These studies are accompanied with a strong prototyping effort to contribute to the optimisation of the Strip ITk's structure and components. This effort culminated recently in the release of the ATLAS Strips ITk Technical Design Report (TDR).

Si microstrip and pad detectors↗

Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector

For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at (z) = 3.5 m and covering the region 2.4 < (Eta) < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 Mu-m thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3x1.3 mm2 and arrays with 2x2 pads with a surface area of 2x2 mm2 or 3x3 mm2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in autumn 2016 with a pion beam of 120 GeV energy at the CERN SPS. In addition to several quantities measured inclusively for each pad, the gain, efficiency and time resolution have been estimated as a function of the position of the incident particle inside the pad by using a beam telescope with a position resolution of few Mu-m. Different methods to measure the time resolution are compared, yielding consistent results. The sensors with a surface area of 1.3x1.3 mm 2 have a time resolution of about 40 ps for a gain of 20 and of about 27 ps for a gain of 50 and fulfill the HGTD requirements. Larger sensors have, as expected, a degraded time resolution. All sensors show very good efficiency and time resolution uniformity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First beam tests of prototype silicon modules for the CMS High Granularity Endcap Calorimeter

The High Luminosity phase of the Large Hadron Collider will deliver 10 times more integrated luminosity than the existing collider, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry. As part of its upgrade program, the Compact Muon Solenoid collaboration is designing a high-granularity calorimeter (HGCAL) to replace the existing endcap calorimeters. It will feature unprecedented transverse and longitudinal readout and triggering segmentation for both electromagnetic and hadronic sections. The electromagnetic section and a large fraction of the hadronic section will be based on hexagonal silicon sensors of 0.5–1 cm 2 cell size, with the remainder of the hadronic section being based on highly-segmented scintillators with silicon photomultiplier readout. The intrinsic high-precision timing capabilities of the silicon sensors will add an extra dimension to event reconstruction, especially in terms of pileup rejection. First hexagonal silicon modules, using the existing Skiroc2 front-end ASIC developed for CALICE, have been tested in beams at Fermilab and CERN in 2016. Here, we present results from these tests, in terms of system stability, calibration with minimum-ionizing particles and resolution (energy, position and timing) for electrons, and the comparisons of these quantities with GEANT4-based simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗