Search NASA⌕ Search

SEARCH · Search NASA

Results for “ORGANIC COMPOUND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Use of the Viatorr Expanded Polytetrafluoroethylene-Covered Stent-Graft for Transjugular Intrahepatic Portosystemic Shunt Creation in Children: Initial Clinical Experience

Four children, three boys and one girl, with a median age of 9 years 8 months, underwent transjugular intrahepatic portosystemic shunt creation with an expanded polytetrafluoroethylene (e-PTFE)-covered nitinol stent. The stent-graft was successfully placed in all four patients without any complication. Clinical and biochemical improvement was noted in all four patients during follow-up. Radiological follow-up with use of duplex ultrasound showed a recurrent stenosis of the shunt 180 days after stent-graft implantation in one patient. This was treated with placement of an additional stent-graft, re-expanding completely the recurrent stenosis. In the other three patients, the stent-graft remained fully patent until the end of the study or until orthotopic liver transplantation. These preliminary results suggest that use of the Viatorr ePTFE-covered stent-graft in children is safe and feasible, with potentially the same high patency rate and improved clinical outcome as reported in adult patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Ischemic Model Using a Radiofrequency Wire Electrode in a Rabbit Hindlimb

The purpose of this study was to establish an ischemic rabbit hindlimb model using a radiofrequency (RF) wire electrode. We inserted a polytetrafluoroethylene-coated wire with a 2-cm exposed tip into the left superficial femoral artery of seven New Zealand white rabbits and performed RF ablation (RFA) while pulling the wire back. We assessed the clinical findings, angiography, computed tomography perfusion, and permeability surface until 6 weeks after RFA. The angiography demonstrated complete obstruction from the proximal external iliac artery to the distal superficial femoral artery and showed a gradual increment in the angiogenic score, which represents the degree of angiogenesis (r = 0.86, p < 0.0001). The left-to-right ratios of the computed tomography perfusion and permeability surface were significantly reduced after 4 days (p < 0.05), and then they gradually increased with time. We conclude that endovascular RFA using an RF wire electrode is a reproducible and measurable way to create an ischemic rabbit hindlimb model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AngioJet Thrombectomy for Occluded Dialysis Fistulae: Outcome Data

This study evaluates AngioJet thrombectomy of occluded autogenous dialysis fistulae and polytetrafluoroethylene (PTFE) grafts in a UK hemodialysis population. Comparison is made with published data of alternative percutaneous thrombectomy methods. All patients with occluded dialysis fistulae who sought care at the Royal Liverpool University Hospital between October 2006 and June 2008 were included in the study. All patients were treated with the AngioJet Rheolytic Thrombectomy Device (Possis, Minneapolis, MN). Demographics, time of occlusion, adjunctive therapies, complications, and follow-up data have been prospectively recorded. A total of 64 thrombectomy procedures were performed in 48 patients. Forty-four autogenous fistulas were treated in 34 patients (19 brachiocephalic, 8 radiocephalic, and 7 transposed brachiobasilic). Twenty PTFE grafts were treated in 14 patients (9 brachioaxillary, 3 brachiocephalic loop grafts, 1 brachiobasilic, and 1 femoro-femoral). The average length of occlusion was 24 cm. Average time to intervention was 4 days. Immediate primary patency was 91%. Primary patency at 1, 3, and 6 months, respectively, was 71%, 60%, and 37%. Secondary patency at 3, 6, and 12 months was 87%, 77%, and 62%, respectively. Angioplasty was carried out in all procedures. Patients required stent insertion in 34 of the 64 thrombectomies to treat angioplasty-resistant stenoses. Complications included a puncture-site hematoma, and three angioplasty-related vein ruptures in one patient, all treated with covered stent grafts. Two cases of distal brachial arterial embolization were successfully treated by thrombosuction. AngioJet thrombectomy in dialysis access occlusion is safe and effective, comparing favorably with other methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Double-Layered PTFE-Covered Nitinol Stents: Experience in 32 Patients with Malignant Esophageal Strictures

We evaluated the effectiveness of a double-layered polytetrafluoroethylene (PTFE)-covered nitinol stent in the palliative treatment of malignant esophageal strictures. A double-layered PTFE-covered nitinol stent was designed to reduce the propensity to migration of conventional covered stent. The stent consists of an inner PTFE-covered stent and an outer uncovered nitinol stent tube. With fluoroscopic guidance, the stent was placed in 32 consecutive patients with malignant esophageal strictures. During the follow-up period, the technical and clinical success rates, complications, and cumulative patient survival and stent patency were evaluated. Stent placement was technically successful in all patients, and no procedural complications occurred. After stent placement, the symptoms of 30 patients (94%) showed improvement. During the mean follow-up of 103 days (range, 9-348 days), 11 (34%) of 32 patients developed recurrent symptoms due to tumor overgrowth in five patients (16%), tumor ingrowth owing to detachment of the covering material (PTFE) apart from the stent wire in 3 (9%), mucosal hyperplasia in 2 (6%), and stent migration in 1 (3%). Ten of these 11 patients were treated by means of placing a second covered stent. Thirty patients died, 29 as a result of disease progression and 1 from aspiration pneumonia. The median survival period was 92 days. The median period of primary stent patency was 190 days. The double-layered PTFE-covered nitinol stent seems to be effective for the palliative treatment of malignant esophageal strictures. We believe that the double-layer configuration of this stent can contribute to decreasing the stent's migration rate.

36 MATERIALS SCIENCE↗

Use of PTFE Stent Grafts for Hemodialysis-related Central Venous Occlusions: Intermediate-Term Results

Purpose: To assess the safety and effectiveness of a polytetrafluoroethylene (PTFE) encapsulated nitinol stents (Bard Peripheral Vascular, Tempe, AZ) for treatment of hemodialysis-related central venous occlusions. Materials and Methods: Study design was a single-center nonrandomized retrospective cohort of patients from May 2004 to August 2009 for a total of 64 months. There were 14 patients (mean age 60 years, range 50-83 years; 13 male, 1 female). All patients had autogenous fistulas. All 14 patients had central venous occlusions and presented with clinical symptoms of the following: extremity swelling (14%, 2 of 14), extremity and face swelling (72%, 10 of 14), and face swelling/edema (14%, 2 of 14). There was evidence of access dysfunction with decreased access flow in 36% (5 of 14) patients. There were prior interventions or previous line placement at the site of the central venous lesion in all 14 patients. Results were assessed by recurrence of clinical symptoms and function of the access circuit (National Kidney Foundation recommended criteria). Results: Sixteen consecutive straight stent grafts were implanted in 14 patients. Average treated lesion length was 5.0 cm (range, 0.9-7 cm). All 14 patients had complete central venous occlusion (100% stenosis). The central venous occlusions were located as follows: right subclavian and brachiocephalic vein (21%, 3 of 14), right brachiocephalic vein (36%, 5 of 14), left brachiocephalic vein (36%, 5 of 14), and bilateral brachiocephalic vein (7%, 1 of 14). A total of 16 PTFE stent grafts were placed. Ten- or 12-mm-diameter PTFE stent grafts were placed. The average stent length was 6.1 cm (range, 4-8 cm). Technical (deployment), anatomic (<30% residual stenosis), clinical (resolution of symptoms), and hemodynamic (resolution of access dysfunction) success were 100%. At 3, 6, and 9 months, primary patency of the treated area and access circuit were 100% (14 of 14). Conclusions: This PTFE encapsulated stent graft demonstrates encouraging intermediate-term patency results for central vein occlusions. Further prospective studies with long-term assessment and larger patient populations will be required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pull-Through Technique for Recanalization of Occluded Portosystemic Shunts (TIPS): Technical Note and Review of the Literature

Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction is an important problem after creation of shunts. Most commonly, TIPS recanalization is performed via the jugular vein approach. Occasionally it is difficult to cross the occlusion. We describe a hybrid technique for TIPS revision via a direct transhepatic access combined with a transjugular approach. In two cases, bare metal stents or polytetrafluoroethylene (PTFE)-covered stent grafts had been placed in TIPS tract previously, and they were completely obstructed. The tracts were inaccessible via the jugular vein route alone. In each case, after fluoroscopy or computed tomography-guided transhepatic puncture of the stented segment of the TIPS, a wire was threaded through the shunt and snared into the right jugular vein. The TIPS was revised by balloon angioplasty and additional in-stent placement of PTFE-covered stent grafts. The patients were discharged without any complications. Doppler sonography 6 weeks after TIPS revision confirmed patency in the TIPS tract and the disappearance of ascites. We conclude that this technique is feasible and useful, even in patients with previous PTFE-covered stent graft placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Palliation of Pancreatic Head Cancer: Randomized Comparison of ePTFE/FEP-Covered Versus Uncovered Nitinol Biliary Stents

The purpose of this study was to compare the clinical effectiveness of expanded polytetrafluoroethylene/fluorinated-ethylene-propylene (ePTFE/FEP)-covered stents with that of uncovered nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer. Eighty patients were enrolled in a prospective randomized study. Bare nitinol stents were used in half of the patients, and ePTFE/FEP-covered stents were used in the remaining patients. Patency, survival, complications, and mean cost were calculated in both groups. Mean patency was 166.0 {+-} 13.11 days for the bare-stent group and 234.0 {+-} 20.87 days for the covered-stent group (p = 0.007). Primary patency rates at 3, 6, and 12 months were 77.5, 69.8, and 69.8% for the bare-stent group and 97.5, 92.2, and 87.6% for the covered-stent group, respectively. Mean secondary patency was 123.7 {+-} 22.5 days for the bare-stent group and 130.3 {+-} 21.4 days for the covered-stent group. Tumour ingrowth occurred exclusively in the bare-stent group in 27.5% of cases (p = 0.002). Median survival was 203.2 {+-} 11.8 days for the bare-stent group and 247.0 {+-} 20 days for the covered-stent group (p = 0.06). Complications and mean cost were similar in both groups. Regarding primary patency and ingrowth rate, ePTFE/FEP-covered stents have shown to be significantly superior to bare nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer and pose comparable cost and complications. Use of a covered stent does not significantly influence overall survival rate; nevertheless, the covered endoprosthesis seems to offer result in fewer reinterventions and better quality of patient life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Seven-Year, Single-Centre Experience of the Long-Term Outcomes of Bovine Ureter Grafts Used as Novel Conduits for Haemodialysis Fistulas

Purpose: To report the long-term outcomes of bovine ureter grafts as novel conduits for haemodialysis fistulas. Materials and Methods: Thirty-five patients underwent placement of a total of 40 SynerGraft 100 (SG100; CryoLife Europa{sup Registered-Sign}, Guildford, UK) bovine ureter grafts between April 2002 and February 2009. Prospective data were collected on all patients, including active surveillance with blood flow studies and 6-monthly duplex ultrasound studies. Main outcome measures were primary and secondary patency rates. Results: Mean follow-up time was 97 weeks (range 4-270). Thirteen patients died from unrelated causes during the study period; 12 of these patients had a functioning graft at the time of death. Five patients underwent transplantation, and all had a functioning graft at transplantation. Twelve patients had a functioning graft at the end of the study period. One hundred and ten stenoses were detected, and 97 venoplasty procedures were performed. Of the stenoses, 41.8% were located at the venous anastomosis, 12.7% within the graft, 17.3% in the outflow veins, and 28.1% in central veins. No arterial stenoses were detected. Primary patency rates were 53% at 6 months and 14% at 1 year. Secondary patency rates were 81% at 6 months, 75% at 1 year, and 56% at 2 years. Conclusions: Active surveillance and intervention was able to achieve satisfactory long-term secondary patency for these novel conduits compared with those made of PTFE seen in other studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypothyroidism After Radiotherapy for Nasopharyngeal Cancer Patients

Purpose: The aim of this study was to determine the long-term incidence and possible predictive factors for posttreatment hypothyroidism in nasopharyngeal carcinoma (NPC) patients after radiotherapy. Methods and Materials: Four hundred and eight sequential NPC patients who had received regular annual thyroid hormone surveys prospectively after radiotherapy were included in this study. Median patient age was 47.3 years, and 286 patients were male. Thyroid function was prospectively evaluated by measuring thyroid-stimulating hormone (TSH) and serum free thyroxine (FT4) levels. Low FT4 levels indicated clinical hypothyroidism in this study. Results: With a median follow-up of 4.3 years (range, 0.54-19.7 years), the incidence of low FT4 level was 5.3%, 9.0%, and 19.1% at 3, 5, and 10 years after radiotherapy, respectively. Hypothyroidism was more common with early T stage (p = 0.044), female sex (p = 0.037), and three-dimensional conformal therapy with the altered fractionation technique (p = 0.005) after univariate analysis. N stage, chemotherapy, reirradiation, and neck electron boost did not affect the incidence of hypothyroidism. Younger age and conformal therapy were significant factors that determined clinical hypothyroidism after multivariate analysis. Overall, patients presented with a low FT4 level about 1 year after presenting with an elevated TSH level. Conclusion: Among our study group of NPC patients, 19.1% experienced clinical hypothyroidism by 10 years after treatment. Younger age and conformal therapy increased the risk of hypothyroidism. We suggest routine evaluation of thyroid function in NPC patients after radiotherapy. The impact of pituitary injury should be also considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3'-deoxy-3'-[{sup 18}F]fluorothymidine PET Quantification of Bone Marrow Response to Radiation Dose

Purpose: The purpose of this study was to quantify the relationship of bone marrow response to radiation dose, using 3'-deoxy-3'-[{sup 18}F]fluorothymidine ([{sup 18}F]FLT)-labeled uptake quantified in positron-emission tomography (PET) scans. Methods and Materials: Pre- and post-Week 1 treatment [{sup 18}F]FLT PET images were registered to the CT images used to create the radiation treatment plan. Changes in [{sup 18}F]FLT uptake values were measured using profile data of standardized uptake values (SUVs) and doses along the vertebral bodies located at a field border where a range of radiation doses were present for 10 patients. Data from the profile measurements were grouped into 1 Gy dose bins from 1 to 9 Gy to compare SUV changes for all patients. Additionally, the maximum pretreatment, the post-Week 1 treatment, and the dose values located within the C6-T7 vertebrae that straddled the field edge were measured for all patients. Results: Both the profile and the individual vertebral data showed a strong correlation between SUV change and radiation dose. Relative differences in SUVs between bins >1 Gy and <7 Gy were statistically significant (p < 0.01, two-sample t test). The reduction in SUV was approximately linear until it reached a reduction threshold of 75%-80% in SUV for doses greater than 6 Gy/week for both the dose-binned data and the vertebral maximum SUVs. Conclusions: The change in SUV observed in head and neck cancer patients treated with chemoradiation shows the potential for using [{sup 18}F]FLT PET images for identifying active bone marrow and monitoring changes due to radiation dose. Additionally, the change in [{sup 18}F]FLT uptake observed in bone marrow for different weekly doses suggests potential dose thresholds for reducing bone marrow toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synthesis of anatase nanoparticles with extremely wide solid solution range and ScTiNbO{sub 6} with alpha-PbO{sub 2} structure

Anatase-type nanoparticles Sc{sub X}Ti{sub 1-2X}Nb{sub X}O{sub 2} with wide solid solution range (X=0-0.35) were hydrothermally formed at 180 deg. C for 5 h. The lattice parameters a{sub 0} and c{sub 0}, and the optical band gap of anatase gradually and linearly increased with the increase of the content of niobium and scandium from X=0 to 0.35. Their photocatalytic activity and adsorptivity by the measurement of the concentration of methylene blue (MB) that remained in the solution in the dark or under UV-light irradiation were evaluated. The anatase phase existed stably up to 900 deg. C for the samples with X=0.25-0.30 and 750 deg. C for that with X=0.35 during heat treatment in air. The phase with alpha-PbO{sub 2} structure and the rutile phases coexisted in the samples with X=0.25-0.30 after heated at temperatures above 900-950 deg. C. The alpha-PbO{sub 2} structure having composition ScTiNbO{sub 6} with possibly some cation order similar to that seen in wolframite existed as almost completely single phase after heat treatment at temperatures 900-1500 deg. C through phase transformation from anatase-type ScTiNbO{sub 6}. - Graphical abstract: Anatase-type Sc{sub X}Ti{sub 1-2X}Nb{sub X}O{sub 2} solid solutions with wide solid solution range (X=0-0.35) were hydrothermally formed as nanoparticles from the precursor solutions of Sc(NO{sub 3}){sub 3}, TiOSO{sub 4}, NbCl{sub 5} at 180 deg. C for 5 h using the hydrolysis of urea. Anatase-type ScTiNbO{sub 6} was synthesized under hydrothermal condition. ScTiNbO{sub 6} having alpha-PbO{sub 2} structure with possibly some cation order similar to that seen in wolframite was formed through phase transformation above 900 deg. C.

36 MATERIALS SCIENCE↗

Disruption of thyroid hormone homeostasis in Ugt1a-deficient Gunn rats by microsomal enzyme inducers is not due to enhanced thyroxine glucuronidation

Microsomal enzyme inducers (MEI) that increase UDP-glucuronosyltransferases (UGTs) are thought to increase glucuronidation of thyroxine (T{sub 4}), thus reducing serum T{sub 4}, and subsequently increasing thyroid stimulating hormone (TSH). Ugt1a1 and Ugt1a6 mediate T{sub 4} glucuronidation. Therefore, this experiment determined the involvement of Ugt1a enzymes in increased T{sub 4} glucuronidation, decreased serum T{sub 4}, and increased TSH after MEI treatment. Male Wistar and Ugt1a-deficient Wistar (Gunn) rats were fed a control diet or diet containing pregnenolone-16{alpha}-carbonitrile (PCN; 800 ppm), 3-methylcholanthrene (3-MC; 200 ppm), or Aroclor 1254 (PCB; 100 ppm) for 7 days. Serum T{sub 4}, triiodothyronine (T{sub 3}), and TSH concentrations, hepatic T{sub 4}/T{sub 3} glucuronidation, and thyroid histology and follicular cell proliferation were investigated. PCN, 3-MC, and PCB treatments decreased serum T{sub 4}, whereas serum T{sub 3} was maintained in both Gunn and Wistar rats (except for PCB treatment). TSH was increased in Wistar and Gunn rats after PCN (130 and 277%) or PCB treatment (72 and 60%). T{sub 4} glucuronidation in Wistar rats was increased after PCN (298%), 3-MC (85%), and PCB (450%), but was extremely low in Gunn rats, and unchanged after MEI. T{sub 3} glucuronidation was increased after PCN (121%) or PCB (58%) in Wistar rats, but only PCN increased T{sub 3} glucuronidation in Gunn rats (43%). PCN treatment induced thyroid morphological changes and increased follicular cell proliferation in both strains. These data demonstrate that T{sub 4} glucuronidation cannot be increased in Ugt1a-deficient Gunn rats. Thus, the decrease in serum T{sub 4}, increase in TSH, and increase in thyroid cell proliferation after MEI are not dependent on increased T{sub 4} glucuronidation, and cannot be attributed to Ugt1a enzymes.

3-METHYLCHOLANTHRENE↗

Esculetin-induced protection of human hepatoma HepG2 cells against hydrogen peroxide is associated with the Nrf2-dependent induction of the NAD(P)H: Quinone oxidoreductase 1 gene

Esculetin (6,7-dihydroxy coumarin), is a potent antioxidant that is present in several plant species. The aim of this study was to investigate the mechanism of protection of esculetin in human hepatoma HepG2 cells against reactive oxygen species (ROS) induced by hydrogen peroxide. Cell viability, cell integrity, intracellular glutathione levels, generation of reactive oxygen species and expression of antioxidant enzymes were used as markers to measure cellular oxidative stress and response to ROS. The protective effect of esculetin was compared to a well-characterized chemoprotective compound quercetin. Pre-treatment of HepG2 cells with sub-lethal (10-25 {mu}M) esculetin for 8 h prevented cell death and maintained cell integrity following exposure to 0.9 mM hydrogen peroxide. An increase in the generation of ROS following hydrogen peroxide treatment was significantly attenuated by 8 h pre-treatment with esculetin. In addition, esculetin ameliorated the decrease in intracellular glutathione caused by hydrogen peroxide exposure. Moreover, treatment with 25 {mu}M esculetin for 8 h increased the expression of NAD(P)H: quinone oxidoreductase (NQO1) at both protein and mRNA levels significantly, by 12-fold and 15-fold, respectively. Esculetin treatment also increased nuclear accumulation of Nrf2 by 8-fold indicating that increased NQO1 expression is Nrf2-mediated. These results indicate that esculetin protects human hepatoma HepG2 cells from hydrogen peroxide induced oxidative injury and that this protection is provided through the induction of protective enzymes as part of an adaptive response mediated by Nrf2 nuclear accumulation.

60 APPLIED LIFE SCIENCES↗

Modulation of methylmercury uptake by methionine: Prevention of mitochondrial dysfunction in rat liver slices by a mimicry mechanism

Methylmercury (MeHg) is an ubiquitous environmental pollutant which is transported into the mammalian cells when present as the methylmercury-cysteine conjugate (MeHg-Cys). With special emphasis on hepatic cells, due to their particular propensity to accumulate an appreciable amount of Hg after exposure to MeHg, this study was performed to evaluate the effects of methionine (Met) on Hg uptake, reactive species (RS) formation, oxygen consumption and mitochondrial function/cellular viability in both liver slices and mitochondria isolated from these slices, after exposure to MeHg or the MeHg-Cys complex. The liver slices were pre-treated with Met (250 {mu}M) 15 min before being exposed to MeHg (25 {mu}M) or MeHg-Cys (25 {mu}M each) for 30 min at 37 {sup o}C. The treatment with MeHg caused a significant increase in the Hg concentration in both liver slices and mitochondria isolated from liver slices. Moreover, the Hg uptake was higher in the group exposed to the MeHg-Cys complex. In the DCF (dichlorofluorescein) assay, the exposure to MeHg and MeHg-Cys produced a significant increase in DFC reactive species (DFC-RS) formation only in the mitochondria isolated from liver slices. As observed with Hg uptake, DFC-RS levels were significantly higher in the mitochondria treated with the MeHg-Cys complex compared to MeHg alone. MeHg exposure also caused a marked decrease in the oxygen consumption of liver slices when compared to the control group, and this effect was more pronounced in the liver slices treated with the MeHg-Cys complex. Similarly, the loss of mitochondrial activity/cell viability was greater in liver slices exposed to the MeHg-Cys complex when compared to slices treated only with MeHg. In all studied parameters, Met pre-treatment was effective in preventing the MeHg- and/or MeHg-Cys-induced toxicity in both liver slices and mitochondria. Part of the protection afforded by Met against MeHg may be related to a direct interaction with MeHg or to the competition of Met with the complex formed between MeHg and endogenous cysteine. In summary, our results show that Met pre-treatment produces pronounced protection against the toxic effects induced by MeHg and/or the MeHg-Cys complex on mitochondrial function and cell viability. Consequently, this amino acid offers considerable promise as a potential agent for treating acute MeHg exposure.

60 APPLIED LIFE SCIENCES↗

1D GAS-DYNAMIC SIMULATION OF SHOCK-WAVE PROCESSES VIA INTERNET

We present a Web-interface for 1D simulation of different shock-wave experiments. The choosing of initial parameters, the modeling itself and output data treatment can be made directly via the Internet. The interface is based upon the expert system on shock-wave data and equations of state and contains both the Eulerian and Lagrangian Godunov hydrocodes. The availability of equations of state for a broad set of substances makes this system a useful tool for planning and interpretation of shock-wave experiments. As an example of simulation with the system, results of modeling of multistep shock loading of potassium between polytetrafluoroethylene and stainless steel plates are presented in comparison with experimental data from Shakhray et al.(2005).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lateral propagation of MeV electrons generated by femtosecond laser irradiation

The propagation of MeV electrons generated by intense (approx =10{sup 20} W/cm{sup 2}) femtosecond laser irradiation, in the lateral direction perpendicular to the incident laser beam, was studied using targets consisting of irradiated metal wires and neighboring spectator wires embedded in electrically conductive (aluminum) or resistive (Teflon) substrates. The K shell spectra in the energy range 40-60 keV from wires of Gd, Dy, Hf, and W were recorded by a transmission crystal spectrometer. The spectra were produced by 1s electron ionization in the irradiated wire and by energetic electron propagation through the substrate material to the spectator wire of a different metal. The electron range and energy were determined from the relative K shell emissions from the irradiated and spectator wires separated by varying substrate lateral distances of up to 1 mm. It was found that electron propagation through Teflon was inhibited, compared to aluminum, implying a relatively weak return current and incomplete space-charge neutralization. The energetic electron propagation in the direction parallel to the electric field of the laser beam was larger than perpendicular to the electric field. Energetic electron production was lower when directly irradiating aluminum or Teflon compared to irradiating the heavy metal wires. These experiments are important for the determination of the energetic electron production mechanism and for understanding lateral electron propagation that can be detrimental to fast-ignition fusion and hard x-ray backlighter radiography.

74 ATOMIC AND MOLECULAR PHYSICS↗

Reflectance of polytetrafluoroethylene for xenon scintillation light

Gaseous and liquid xenon particle detectors are being used in a number of applications including dark matter search and neutrino-less double beta decay experiments. Polytetrafluoroethylene (PTFE) is often used in these detectors both as electrical insulator and as a light reflector to improve the efficiency of detection of scintillation photons. However, xenon emits in the vacuum ultraviolet (VUV) wavelength region ({lambda}{approx_equal}175 nm) where the reflecting properties of PTFE are not sufficiently known. In this work, we report on measurements of PTFE reflectance, including its angular distribution, for the xenon scintillation light. Various samples of PTFE, manufactured by different processes (extruded, expanded, skived, and pressed) have been studied. The data were interpreted with a physical model comprising both specular and diffuse reflections. The reflectance obtained for these samples ranges from about 47% to 66% for VUV light. Other fluoropolymers, namely, ethylene tetrafluoroethylene (ETFE), fluorinated ethylene propylene (FEP), and perfluoro-alkoxyalkane (PFA) were also measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗