Search NASA⌕ Search

SEARCH · Search NASA

Results for “Objectives”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Gravimeter Search for Compact Dark Matter Objects Moving in the Earth

Dark matter could be composed of compact dark objects (CDOs). These objects may interact very weakly with normal matter and could move freely inside the Earth. A CDO moving in the inner core of the Earth will have an orbital period near 55 min and produce a time-dependent signal in a gravimeter. Data from superconducting gravimeters rule out such objects moving inside the Earth unless their mass m D and or orbital radius a are very small so that m D a < 1.2 × 10 - 13 M ⊕ R ⊕ . Here, M ⊕ and R ⊕ are the mass and radius of the Earth, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Inspection of the objects on the sea floor by using 14 MeV tagged neutrons

Variety of objects found on the sea floor needs to be inspected for the presence of materials which represent the threat to the environment and to the safety of humans. We have demonstrated that the sealed tube 14 MeV neutron generator with the detection of associated alpha particles can be used underwater when mounted inside ROV equipped with the hydraulic legs and variety of sensors for the inspection of such objects for the presence of threat materials. Such a system is performing the measurement by using the NaI gamma detector and an API-120 neutron generator which could be rotated in order to maximize the inspected target volume. The neutron beam intensity during the 10-30 min. measurements is usually 1 x 10{sup 7} n/s in 4{pi}. In this report the experimental results for some of commonly found objects containing TNT explosive or its simulant are presented. The measured gamma spectra are dominant by C, O and Fe peaks enabling the determination of the presence of explosives inside the ammunition shell. Parameters influencing the C/O ratio are discussed in some details. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AMG Preconditioners based on parallel hybrid coarsening and multi-objective graph matching

We describe preliminary results from a multi-objective graph matching algorithm, in the coarsening step of an aggregation-based Algebraic MultiGrid (AMG) preconditioner, for solving large and sparse linear systems of equations on high-end parallel computers. We have two objectives. First, we wish to improve the convergence behavior of the AMG method when applied to highly anisotropic problems. Second, we wish to extend the parallel package \texttt{PSCToolkit} to exploit multi-threaded parallelism at the node level on multi-core processors. Our matching proposal balances the need to simultaneously compute high weights and large cardinalities by a new formulation of the weighted matching problem combining both these objectives using a parameter $\lambda$. We compute the matching by a parallel $2/3-\varepsilon$-approximation algorithm for maximum weight matchings. Results with the new matching algorithm show that for a suitable choice of the parameter $\lambda$ we compute effective preconditioners in the presence of anisotropy, i.e., smaller solve times, setup times, iterations counts, and operator complexity.

D'Ambra, Pasqua↗

A Multi-objective Microgrid Assessment and Sizing Framework for Economic and Resilience Benefits

This paper presents an innovative multi-objective assessment and sizing framework for battery energy storage system paired with photovoltaics for a cost-effective and resilient microgrid. In the proposed framework, we simultaneously consider i) economic benefits from bundling grid services in grid-connected mode and ii) enhanced resilience by operating the microgrid in island mode upon outages of the main grid. Instead of simply treating resilience as another monetary value stream, this paper models resilience and economic benefits as two separate objectives. Multi-objective optimization is developed to explore different sizing and dispatch options and generate the Pareto front to assist decision-making in system design. Case studies on a real-world microgrid project in Puget Sound Energy system are presented to illustrate the proposed modeling and sizing methods.

Battery energy storage, Microgrid, Optimal Sizingp↗

Data Management in the Continuum: Cross-facility Object-based Data Transfers

Scientific workflows are evolving from relying on a monolithic storage subsystem at a single High-Performance Computing (HPC) facility to using geographically distributed file systems, repositories, and cloud storage. As a result, storing, accessing, transferring, and managing scientific data have become highly complex and prone to performance inefficiencies. This paper delves into these challenges by exploring an optimized end-to-end interface designed to seamlessly connect various local and remote storage systems, enabling efficient data movement of objects across HPC–Cloud and HPC–HPC environments. We showcase this capability through an object-focused data management runtime system, discuss the effects of relaxed consistency semantics in distributed object scenarios, and illustrate its application in an earthquake simulation workflow. Besides reducing the amount of data by selectively transferring regions of interest, our facility-local results achieved a speedup of 45 × over an optimized HDF5 usage and 15 × over the HDF5 with caching by using the new interface in PDC-XF.

Bez, Jean Luca↗

Cyber-Physical Attacks With Control Objectives

This study studies attackers with control objectives against cyber-physical systems (CPSs). The goal of the attacker is to counteract the CPS's controller and move the system to a target state while evading detection. We formulate a cost function that reflects the attacker's goals, and, using dynamic programming, we show that the optimal attack strategy reduces to a linear feedback of the attacker's state estimate. By changing the parameters of the cost function, we show how an attacker can design optimal attacks to balance the control objective and the detection avoidance objective. In conclusion, we provide a numerical illustration based on a remotely controlled helicopter under attack.

97 MATHEMATICS AND COMPUTING↗

Objective assessment of image quality and dose reduction in CT iterative reconstruction

Purpose: Iterative reconstruction (IR) algorithms have the potential to reduce radiation dose in CT diagnostic imaging. As these algorithms become available on the market, a standardizable method of quantifying the dose reduction that a particular IR method can achieve would be valuable. Such a method would assist manufacturers in making promotional claims about dose reduction, buyers in comparing different devices, physicists in independently validating the claims, and the United States Food and Drug Administration in regulating the labeling of CT devices. However, the nonlinear nature of commercially available IR algorithms poses challenges to objectively assessing image quality, a necessary step in establishing the amount of dose reduction that a given IR algorithm can achieve without compromising that image quality. This review paper seeks to consolidate information relevant to objectively assessing the quality of CT IR images, and thereby measuring the level of dose reduction that a given IR algorithm can achieve. Methods: The authors discuss task-based methods for assessing the quality of CT IR images and evaluating dose reduction. Results: The authors explain and review recent literature on signal detection and localization tasks in CT IR image quality assessment, the design of an appropriate phantom for these tasks, possible choices of observers (including human and model observers), and methods of evaluating observer performance. Conclusions: Standardizing the measurement of dose reduction is a problem of broad interest to the CT community and to public health. A necessary step in the process is the objective assessment of CT image quality, for which various task-based methods may be suitable. This paper attempts to consolidate recent literature that is relevant to the development and implementation of task-based methods for the assessment of CT IR image quality.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-01: A Logistic Regression Model to Predict Objective Function Weights in Prostate Cancer IMRT

Purpose: To develop a statistical model that predicts optimization objective function weights from patient geometry for intensity-modulation radiotherapy (IMRT) of prostate cancer. Methods: A previously developed inverse optimization method (IOM) is applied retrospectively to determine optimal weights for 51 treated patients. We use an overlap volume ratio (OVR) of bladder and rectum for different PTV expansions in order to quantify patient geometry in explanatory variables. Using the optimal weights as ground truth, we develop and train a logistic regression (LR) model to predict the rectum weight and thus the bladder weight. Post hoc, we fix the weights of the left femoral head, right femoral head, and an artificial structure that encourages conformity to the population average while normalizing the bladder and rectum weights accordingly. The population average of objective function weights is used for comparison. Results: The OVR at 0.7cm was found to be the most predictive of the rectum weights. The LR model performance is statistically significant when compared to the population average over a range of clinical metrics including bladder/rectum V53Gy, bladder/rectum V70Gy, and mean voxel dose to the bladder, rectum, CTV, and PTV. On average, the LR model predicted bladder and rectum weights that are both 63% closer to the optimal weights compared to the population average. The treatment plans resulting from the LR weights have, on average, a rectum V70Gy that is 35% closer to the clinical plan and a bladder V70Gy that is 43% closer. Similar results are seen for bladder V54Gy and rectum V54Gy. Conclusion: Statistical modelling from patient anatomy can be used to determine objective function weights in IMRT for prostate cancer. Our method allows the treatment planners to begin the personalization process from an informed starting point, which may lead to more consistent clinical plans and reduce overall planning time.

60 APPLIED LIFE SCIENCES↗

Computer aided detection of surgical retained foreign object for prevention

Purpose: Surgical retained foreign objects (RFOs) have significant morbidity and mortality. They are associated with approximately $1.5 × 10{sup 9} annually in preventable medical costs. The detection accuracy of radiographs for RFOs is a mediocre 59%. The authors address the RFO problem with two complementary technologies: a three-dimensional (3D) gossypiboma micro tag, the μTag that improves the visibility of RFOs on radiographs, and a computer aided detection (CAD) system that detects the μTag. It is desirable for the CAD system to operate in a high specificity mode in the operating room (OR) and function as a first reader for the surgeon. This allows for fast point of care results and seamless workflow integration. The CAD system can also operate in a high sensitivity mode as a second reader for the radiologist to ensure the highest possible detection accuracy. Methods: The 3D geometry of the μTag produces a similar two dimensional (2D) depiction on radiographs regardless of its orientation in the human body and ensures accurate detection by a radiologist and the CAD. The authors created a data set of 1800 cadaver images with the 3D μTag and other common man-made surgical objects positioned randomly. A total of 1061 cadaver images contained a single μTag and the remaining 739 were without μTag. A radiologist marked the location of the μTag using an in-house developed graphical user interface. The data set was partitioned into three independent subsets: a training set, a validation set, and a test set, consisting of 540, 560, and 700 images, respectively. A CAD system with modules that included preprocessing μTag enhancement, labeling, segmentation, feature analysis, classification, and detection was developed. The CAD system was developed using the training and the validation sets. Results: On the training set, the CAD achieved 81.5% sensitivity with 0.014 false positives (FPs) per image in a high specificity mode for the surgeons in the OR and 96.1% sensitivity with 0.81 FPs per image in a high sensitivity mode for the radiologists. On the independent test set, the CAD achieved 79.5% sensitivity with 0.003 FPs per image in a high specificity mode for the surgeons and 90.2% sensitivity with 0.23 FPs per image in a high sensitivity mode for the radiologists. Conclusions: To the best of the authors’ knowledge, this is the first time a 3D μTag is used to produce a recognizable, substantially similar 2D projection on radiographs regardless of orientation in space. It is the first time a CAD system is used to search for man-made objects over anatomic background. The CAD system for the μTags achieved reasonable performance in both the high specificity and the high sensitivity modes.

60 APPLIED LIFE SCIENCES↗

Models for predicting objective function weights in prostate cancer IMRT

Purpose: To develop and evaluate the clinical applicability of advanced machine learning models that simultaneously predict multiple optimization objective function weights from patient geometry for intensity-modulated radiation therapy of prostate cancer. Methods: A previously developed inverse optimization method was applied retrospectively to determine optimal objective function weights for 315 treated patients. The authors used an overlap volume ratio (OV) of bladder and rectum for different PTV expansions and overlap volume histogram slopes (OVSR and OVSB for the rectum and bladder, respectively) as explanatory variables that quantify patient geometry. Using the optimal weights as ground truth, the authors trained and applied three prediction models: logistic regression (LR), multinomial logistic regression (MLR), and weighted K-nearest neighbor (KNN). The population average of the optimal objective function weights was also calculated. Results: The OV at 0.4 cm and OVSR at 0.1 cm features were found to be the most predictive of the weights. The authors observed comparable performance (i.e., no statistically significant difference) between LR, MLR, and KNN methodologies, with LR appearing to perform the best. All three machine learning models outperformed the population average by a statistically significant amount over a range of clinical metrics including bladder/rectum V53Gy, bladder/rectum V70Gy, and dose to the bladder, rectum, CTV, and PTV. When comparing the weights directly, the LR model predicted bladder and rectum weights that had, on average, a 73% and 74% relative improvement over the population average weights, respectively. The treatment plans resulting from the LR weights had, on average, a rectum V70Gy that was 35% closer to the clinical plan and a bladder V70Gy that was 29% closer, compared to the population average weights. Similar results were observed for all other clinical metrics. Conclusions: The authors demonstrated that the KNN and MLR weight prediction methodologies perform comparably to the LR model and can produce clinical quality treatment plans by simultaneously predicting multiple weights that capture trade-offs associated with sparing multiple OARs.

60 APPLIED LIFE SCIENCES↗

TU-FG-209-05: Demonstration of the Line Focus Principle Using the Generalized Measured-Relative Object Detectability (GM-ROD) Metric

Purpose: Demonstrate and quantify the augmented resolution due to focalspot size decrease in images acquired on the anode side of the field, for both small and medium (0.3 and 0.6mm) focal-spot sizes using the experimental task-based GM-ROD metric. Theoretical calculations have shown that a medium focal-spot can achieve the resolution of a small focal-spot if acquired with a tilted anode, effectively providing a higher-output small focal-spot. Methods: The MAF-CMOS (micro-angiographic fluoroscopic complementary-metal-oxide semiconductor) detector (75µm pixel pitch) imaged two copper wire segments of different diameter and a pipeline stent at the central axis and on the anode side of the beam, achieved by tilting the x-ray C-arm (Toshiba Infinix) to 6° and realigning the detector with the perpendicular ray to correct for x-ray obliquity. The relative gain in resolution was determined using the GM-ROD metric, which compares images on the basis of the Fourier transform of the image and the measured NNPS. To emphasize the geometric unsharpness, images were acquired at a magnification of two. Results: Images acquired on the anode side were compared to those acquired on the central axis with the same target-area focal-spot to consider the effect of an angled tube, and for all three objects the advantage of the smaller effective focal-spot was clear, showing a maximum improvement of 36% in GM-ROD. The images obtained with the small focal-spot at the central axis were compared to those of the medium focal-spot at the anode side and, for all objects, the relative performance was comparable. Conclusion: For three objects, the GM-ROD demonstrated the advantage of the anode side focal-spot. The comparable performance of the medium focal-spot on the anode side will allow for a high-output small focal-spot; a necessity in endovascular image-guided interventions. Partial support from an NIH grant R01EB002873 and an equipment grant from Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Local-field anisotropy of a light wave in quasi-two-dimensional soft-matter objects

Experimental values of the Lorentz tensor components L{sub j} for uniaxial quasi-two dimensional 'soft matter' objects on substrates (bilayer lipid membranes, multilayer Langmuir films, smectics A, hexatic smectics B, submicron films of discotics Col{sub hd}, micron anisotropic films of liquid-crystal comblike polymers and macromolecular polymers, submicron films of conjugated conductive polymers), freely suspended submicron films of smectics A, and uniaxially stretched micron films of conjugated conductive polymers have been determined using dispersion of refractive indices in the visible range. The dependences of the components L{sub j} on the type of orientation (axial, planar) of uniaxial molecules (structural units of the film) with respect to the optical axis of the film, the film thickness, the substrate type, the chemical structure of molecules, and their long-range orientational order are established. It is revealed that the smectic A-hexatic B phase transition and two-dimensional crystallization of the smectic layer lead to changes in the components L{sub j} due to the change in the orientational ordering of molecules as a result of the relation between the orientational and hexatic order parameters. All the above objects are characterized by isotropization of the Lorentz tensor L and the local-field tensor f with a simultaneous decrease in the birefringence of the sample and in the anisotropy of the molecular polarizability due to the change in the electronic structure of molecules. The correction for the anisotropy of the local-field tensor f to the orientational order parameter or the anisotropy of the molecular polarizability increases. The existing model approaches to calculating the components L{sub j} for the objects under consideration are compared with the experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interaction of the equipotential surface of a charged object with weak laser radiation

Experiments were carried out on how laser radiation affects both the shape of an escaping plasma jet and the formation of a luminous object after the jet has been ejected from the electrode. It is shown that a 1-mW laser beam with an intensity as low as 0.001 W/cm{sup 2} can change the shape of the jet and its propagation direction. In applying laser diagnostic methods, it is necessary to take into account possible change in the configuration of such objects when they interact with laser radiation. It is confirmed that the temperature of a luminous object decreases sharply with time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A review of projection radiography of plasma and biological objects in X-Pinch radiation

A review of studies on the X-pinch as a radiation source for X-ray projection shadow radiography (XPSR) and X-ray absorption spectroscopy (XAS) is presented. The ultimate capabilities of the techniques and ways of their achievement are considered. XPSR has been successfully used to study high-energy-density plasma objects, in particular, exploding wires and wire arrays. Using XPSR, the internal structure and dynamics of a wire explosion and wire array implosion have been investigated for the first time, which has made it possible to develop an adequate consistent theory of the processes occurring in the wire loads of generators with currents from several units of kiloamperes to a few tens of megamperes. The use of XAS for diagnostics of wire loads has allowed one for the first time to measure the parameters of matter in the wire core and plasma corona of the load. X-ray images of various biological objects have obtained, including those with the use of the phase contrast method. This review is a logical continuation of the review ''X-Pinch'' [Plasma Phys. Rep. 41, 319, 493 (2015)], in which the X-pinch as a physical object was considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flexible and Effective Object Tiering for Heterogeneous Memory Systems

Computing platforms that package multiple types of memory, each with their own performance characteristics, are quickly becoming mainstream. To operate efficiently, heterogeneous memory architectures require new data management solutions that are able to match the needs of each application with an appropriate type of memory. As the primary generators of memory usage, applications create a great deal of information that can be useful for guiding memory tiering, but the community still lacks tools to collect, organize, and leverage this information effectively. To address this gap, this work introduces a novel software framework that collects and analyzes object-level information to guide memory tiering. Using this framework, this study evaluates and compares the impact of a variety of data tiering choices, including how the system prioritizes objects for faster memory as well as the frequency and timing of migration events. The results, collected on a modern Intel platform with conventional DRAM as well as non-volatile RAM, show that guiding data tiering with object-level information can enable significant performance and efficiency benefits compared to standard hardware- and software-directed data tiering strategies.

Kammerdiener, Brandon↗

Generalized spatial filtering velocimetry and accelerometry for uniform and nonuniform objects

We present a technique to measure velocity, acceleration, and higher order derivatives of motion using periodic and nonperiodic spatial filters. The technique can be applied using a single detector or an array of detectors. In one configuration, the velocity distribution of an object such as a fluid can be measured by imaging the object onto an array of detectors. In another configuration, multiple projections of an object are used to reconstruct a cross-sectional velocity distribution using a tomography algorithm. The advantages and disadvantages of our technique applied to uniform and spatially varying motions are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Height measurement of transparent objects by adopting differential interference contrast technology

In this study, the differential interference contrast (DIC) approach originally used for image enhancement to increase the contrast between a transparent object and the background is adopted for the dimension measurement of transparent structures. With the phase difference image retrieved using the DIC technique, the phase map of the examined object can be approximated by integrating the phase difference. The need of integration accuracy is much higher for measurement than for image enhancement. In this study, a modified Fourier phase integration is proposed to reduce the effects of noise on surface profile reconstruction. The simulation results show that the proposed approach can effectively reduce the effects of noise. Experimental results are also conducted to study the feasibility of using the transmitted DIC with the proposed integration method for transparent object measurement. The results show that the height of a transparent structure measured using the DIC method is quite close to those measured using an atomic force microscope, while those measured using the white-light interference method result in a much larger measurement than all others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Incorporating the effects of objects in an approximate model of light transport in scattering media

A computationally efficient radiative transport model is presented that predicts a camera measurement and accounts for the light reflected and blocked by an object in a scattering medium. The model is in good agreement with experimental data acquired at the Sandia National Laboratory Fog Chamber Facility (SNLFC). The model is applicable in computational imaging to detect, localize, and image objects hidden in scattering media. Here, a statistical approach was implemented to study object detection limits in fog.

42 ENGINEERING↗