Search NASA⌕ Search

SEARCH · Search NASA

Results for “Occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Intersecting heuristic adaptive strategies, building design and energy saving intentions when facing discomfort environment: A cross-country analysis

Occupants' adaptive strategies play an important role in the energy consumption of office buildings. Previous research has mostly focused on the adaptive strategies triggered by occupants' indoor discomfort; however, it is crucial to understand if specific adaptive strategies are linked to occupants' energy-saving intentions. This study explores the relationships among employees’ heuristic decision-making in their first choice of adaptive strategies (technological solutions or personal adjustments) when facing extreme discomfort conditions, and their energy-saving intentions, then links these patterns with building design, workplace contextual factors, and demographics. A cross-sectional survey was collected among university employees from China, Brazil, Italy, Poland, Switzerland, and the US. Our results demonstrated that the accessibility to indoor environmental controls (IECs) and office type are the significant factors for adaptive strategies. There was a positive relationship between the number of IEC features and the percentage of employees choosing a technological solution. When feeling too hot, occupants in private offices are more likely to adopt a technological solution, whereas occupants in cubicles are more likely to choose a personal adjustment. Occupants with energy-saving intentions are less likely to choose thermostat adjustments or use portable devices as adaptive strategies than their counterparts. Lastly, the cluster analysis suggests females were more likely to use adaptive strategies for energy-saving purposes than males. The majority of occupants would turn on/off lighting to save energy. The study provides the contributions in the connection between the heuristic decision-making process and energy-saving intentions and recommendations on design strategies for building architects, engineers, and managers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BLEMS (award #DE-EE0004019) Final Report

This project focused on the development and testing of a non-intrusive “bolt-on” solution called the Building Level Energy Management System (BLEMS) which reduces day-to-day electric energy consumption by at least 20% while maintaining or improving occupant comfort. BLEMS learns occupants’ energy usage behavior, and comfort preferences, as well as building system behavior and uses this information to reduce energy consumption and related greenhouse gas emissions, while simultaneously meeting occupants’ comfort and building usage needs (i.e., day-to-day energy usage goals, demand response energy usage levels, etc.). In BLEMS, humans and building systems and devices interact ubiquitously in real time through an integrated sensor and control system for reduced building electricity consumption. The solution enables bidirectional communication between building systems and occupants, obtains occupant input on comfort level preferences, and operates the building based on measured system response, occupant feedback, and predicted occupancy. Although designed to be used in any building, we focused on commercial buildings as they are a major consumer of HVAC power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exceptionally Complex Electronic Structures of Lanthanide Oxides and Small Molecules

Lanthanide (Ln) oxide clusters and molecular systems provide a bottom-up look at the electronic structures of the bulk materials because of close parallels in the patterns of Ln 4fN subshell occupancy between the molecular and bulk Ln 2 O 3 size limits. At the same time, these clusters and molecules offer a challenge to the theory community to find appropriate and robust treatments for the 4f N patterns across the Ln series. Anion photoelectron (PE) spectroscopy provides a powerful experimental tool for studying these systems, mapping the energies of the ground and low-lying excited states of the neutral relative to the initial anion state, providing spectroscopic patterns that reflect the Ln 4f N occupancy. In this Account, we review our anion PE spectroscopic and computational studies on a range of small lanthanide molecules and cluster species. The PE spectra of LnO – (Ln = Ce, Pr, Sm, Eu) diatomic molecules show spectroscopic signatures associated with detachment of an electron from what can be described as a diffuse Ln 6s-like orbital. While the spectra of all four diatomics share this common transition, the fine structure in the transition becomes more complex with increasing 4f occupancy. This effect reflects increased coupling between the electrons occupying the corelike 4f and diffuse 6s orbitals with increasing N. Understanding the PE spectra of these diatomics sets the stage for interpreting the spectra of polyatomic molecular and cluster species. In general, the results confirm that the partial 4f N subshell occupancy is largely preserved between molecular and bulk oxides and borides. However, they also suggest that surfaces and edges of bulk materials may support a low-energy, diffuse Ln 6s band, in contrast to bulk interiors, in which the 6s band is destabilized relative to the 5d band. We also identify cases in which the molecular Ln centers have 4f N+1 occupancy rather than bulklike 4f N , which results in weaker Ln–O bonding. Specifically, Sm centers in mixed Ce–Sm oxides or in Sm x O y – (y ≤ x) clusters have this higher 4f N+1 occupancy. The PE spectra of these particular species exhibit a striking increase in the relative intensities of excited-state transitions with decreasing photon energy (resulting in lower photoelectron kinetic energy). Furthermore, this is opposite of what is expected on the basis of the threshold laws that govern photodetachment. We relate this phenomenon to strong electron–neutral interactions unique to these complex electronic structures. The time scale of the interaction, which shakes up the electronic configuration of the neutral, increases with decreasing electron momentum. From a computational standpoint, we point out that special care must be taken when considering Ln cluster and molecular systems toward the center of the Ln series (e.g., Sm, Eu), where treatment of electrons explicitly or using an effective core potential can yield conflicting results on competing subshell occupancies. However, despite the complex electronic structures associated with partially filled 4f N subshells, we demonstrate that inexpensive and tractable calculations yield useful qualitative insight into the general electronic structural features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System and method of energy management control

A method of controlling energy consumption in a building includes receiving occupancy data including at least one of occupant request data and occupant schedule data, receiving weather data including at least one of current weather measurement data and weather forecast data, generating an output control signal based on the occupancy data and the weather data, and transmitting the output control signal to a building automation system (BAS) of the building. The occupant request data includes a current request, and the occupant schedule data includes a predicted occupant schedule. The output control signal adjusts a building control device in a zone in the building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wynkoop Building Performance Measurement: Water

This report is a summary of the water analysis performance for the Denver, Colorado Wynkoop Building. The Wynkoop Building (Figure 1) was built in 2006 as the Environmental Protection Agency (EPA) Region 8 Headquarters intended to house over 900 occupants in the 301,292 gross square feet (248,849 rentable square feet). The building was built on a brownfield in the Lower Downtown Historic District as part of an urban redevelopment effort. The building was designed and constructed through a public-private partnership with the sustainable design elements developed jointly by General Services Administration (GSA) and EPA. That partnership is still active with all parties still engaged to optimize building operations and use the building as a Learning Laboratory. The building design achieved U.S. Green Building Council Leadership in Energy and Environmental Design for New Construction (LEED-NC) Gold Certification in 2008 (Figure 2) and a 2008 EPA Energy Star Rating of 96 with design highlights that include: (1) Water use was designed to use 40% less than a typical design baseline. The design included low flow fixtures, waterless urinals and dual flush toilets; (2) Native and adaptive vegetation were selected to minimize the need for irrigation water for landscaping; and (3) Energy use intensity was modeled at 66.1 kBtus/gross square foot, which is 39% better than ASHRAE 90.1 1999. The Wynkoop Building water use (10 gallons/square foot) was measured at lower than industry average (15 gallons/square foot) and GSA goals (13 gallons/square foot), however, it was higher than building management expected it would be. The type of occupants and number of occupants can have a significant impact on fixture water use. The occupancy per floor varied significantly over the study time period, which added uncertainty to the data analysis. Investigation of the fixture use on the 2nd, 5th, and 7th floors identified potential for water use reduction if the flush direction of the dual-flush toilet handles was reversed. The building management retrofitted the building's toilets with handles that operated on reduced flush when pushed down (0.8 gallons) and full flush when pulled up (1.1 gallons). The water pressure on the 5th floor (< 30 psi) is less than half the pressure on the 7th floor (>80 psi). The measured water savings post-retrofit was lower on the 5th floor than the 7th floor. The differences in water pressure may have had an impact on the quantity of water used per floor. The second floor water use was examined prior to and following the toilet fixture retrofit. This floor is where conference rooms for non-building occupants are available for use, thus occupancy is highly variable. The 3-day average volume per flush event was higher post-retrofit (0.79 gallons per event), in contrast to pre-retrofit (0.57 gallons per event). There were 40% more flush events post retrofit, which impacted the findings. Water use in the third floor fitness center was also measured for a limited number of days. Because of water line accessibility, only water use on the men's side of the fitness center was measured and from that the total fitness center water use was estimated. Using the limited data collected, the fitness center shower water use is approximately 2% of the whole building water use. Overall water use in the Wynkoop Building is below the industry baseline and GSA expectations. The dual flush fixture replacement appears to have resulted in additional water savings that are expected to show a savings in the total annual water use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Air Distribution Effectiveness for Residential Mechanical Ventilation: Simulation and Comparison of Normalized Exposures

The purpose of ventilation is to dilute indoor contaminants that an occupant is exposed to. Even when providing the same nominal rate of outdoor air, different ventilation systems may distribute air in different ways, affecting occupants' exposure to household contaminants. Exposure ultimately depends on the home being considered, on source disposition and strength, on occupants' behavior, on the ventilation strategy, and on operation of forced air heating and cooling systems. In any multi-zone environment dilution rates and source strengths may be different in every zone and change in time, resulting in exposure being tied to occupancy patterns.This paper will report on simulations that compare ventilation systems by assessing their impact on exposure by examining common house geometries, contaminant generation profiles, and occupancy scenarios. These simulations take into account the unsteady, occupancy-tied aspect of ventilation such as bathroom and kitchen exhaust fans. As most US homes have central HVAC systems, the simulation results will be used to make appropriate recommendations and adjustments for distribution and mixing to residential ventilation standards such as ASHRAE Standard 62.2.This paper will report on work being done to model multizone airflow systems that are unsteady and elaborate the concept of distribution matrix. It will examine several metrics for evaluating the effect of air distribution on exposure to pollutants, based on previous work by Sherman et al. (2006).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Energy Savings Potential from the Use of Demand Controlled Ventilation in General Office Spaces in California

A prototypical office building meeting the prescriptive requirements of the 2008 California building energy efficiency standards (Title 24) was used in EnergyPlus simulations to calculate the energy savings potential of demand controlled ventilation (DCV) in five typical California climates per three design occupancy densities and two minimum ventilation rates. The assumed minimum ventilation rates in offices without DCV, based on two different measurement methods employed in a large survey, were 38 and 13 L/s per occupant. The results of the life cycle cost analysis show DCV is cost effective for office spaces if the typical minimum ventilation rate without DCV is 38 L/s per person, except at the low design occupancy of 10.8 people per 100 m2 in climate zones 3 (north coast) and 6 (south Coast). DCV was not found to be cost effective if the typical minimum ventilation rate without DCV is 13 L/s per occupant, except at high design occupancy of 21.5 people per 100 m2 in climate zones 14 (desert) and 16 (mountains). Until the large uncertainties about the base case ventilation rates in offices without DCV are reduced, the case for requiring DCV in general office spaces will be a weak case. Under the Title 24 Standards office occupant density of 10.8 people per 100 m2, DCV becomes cost effective when the base case minimum ventilation rate is greater than 42.5, 43.0, 24.0, 19.0, and 18.0 L/s per person for climate zone 3, 6, 12, 14, and 16 respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unitizing worker expertise and maximizing the brain reward centers

People are experts when it comes to the work they do; unfortunately their expertise is not utilized as frequently as it could be. More opportunities need to be provided that allow people to participate in the design of their work including: accident investigations, job planning, and process improvements. Many employers use some form of job hazard analysis process to identify and document hazards and controls, but the front line worker is rarely involved. This presentation will show the core principles supporting employee involvement, provide examples where workers had brilliant ideas but no one listened, and provide examples where workers were given the opportunity to use their expertise to improve occupational safety. According to Abraham Maslow's Hierarch of Needs model, one essential human need is to be innovative and solve problems. Advances in brain science have proven, through functional magnetic resonance imaging (fMRI) studies, the brain reward pathway is activated when people are recognized for their intellectual contributions. As people contribute their expertise to improve occupational safety more frequently they will feel a sense of gratification. In addition, safety professionals will have more time to spend on strategic planning of emerging occupational safety issues. One effect of the current global recession is that SH&E professionals are asked to do more with less. Therefore, to be successful it is essential that SH&E professionals incorporate worker expertise in job planning. This will be illustrated in the presentation through an example where a worker had the answer to a difficult decision on appropriate personal protective equipment for a job but no one asked the worker for his idea during the job planning phase. Fortunately the worker was eventually consulted and his recommendation for the appropriate personal protective equipment for the job was implemented before work began. The goal of this presentation is to expand the awareness and knowledge of SH&E professionals on the benefits and opportunities for leveraging brain science. This will include an overview of the components of the brain reward pathway and the biological mechanisms that make workers feel a sense of gratification when they contribute their ideas toward improving occupational safety. On-the-job examples where it is hypothesized that the brain reward pathway was activated in workers will be provided. Finally, the presentation will include a model illustrating the importance of empowering workers to participate in occupational safety programs. SH&E professionals can use this model to maintain a robust safety and health program with limited resources. The model will also help SH&E professionals prepare for challenges in the SH&E fields by showing them how to allocate more time for strategic planning of emerging issues. Many recent best selling business books such as Wikinomics, Crowdsourcing, and Sway, illustrate how the benefit of harnessing the collective knowledge of employees is a key to company success. Companies like Google and Pixar have mastered the ability to capture empFoyee knowledge in terms of technology. Why should occupational safety be any different? Workers know how to improve safety in their workplace. SH&E professionals can harness this collective safety knowledge just as top companies do with technology, and workers will feel grateful for contributing.

57↗

Superstructures and Superconductivity Linked with Pd Intercalation in Nb 2 Pd x Se 5

Single crystals of Nb 2 Pd x Se 5 have been grown covering a broad range of palladium stoichiometries, from x = 0.68 to x = 0.95 (Pd2 occupancies 0.36 and 0.90 respectively). Miscibility gaps in the Pd stoichiometry range are related to superstructures resulting from staged filling and ordering of the partially filled Pd atom site (Pd2, Wyckoff site 2a). For Pd2 near 1/2 occupancy, a superstructure based on an incommensurate occupation wave with modulation along the monoclinic b-axis is identified. Here, a superconducting dome is found for Pd2 occupancies above 0.58, with maximum Tc for Pd2 occupancy of approximately 2/3. DFT calculations for the fully and 1/2 occupied Pd2 site show that Nb 2 Pd x Se 5 can be considered an intercalation compound for Pd2 occupancy above the minimum required for structural stability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure and stability of solid Xe(H{sub 2}){sub n}

Mixtures of xenon and molecular hydrogen form a series of hexagonal, van der Waals compounds at high pressures and at 300 K. Synchrotron, x-ray, single crystal diffraction studies reveal that below 7.5 GPa, Xe(H{sub 2}){sub 8} crystallizes in a P3{sup -}m1 structure that displays pressure-induced occupancy changes of two pairs of xenon atoms located on the 2c and 2d sites (while the third pair on yet another 2c site remains fully occupied). The occupancy becomes 1 at the P3{sup -}m1 to R3 transition and all the xenon atoms occupy the 3d sites in the high-pressure structure. These pressure-induced changes in occupancy coincide with volume changes that maintain the average Xe:H{sub 2} stoichiometry fixed at 1:8. The synchrotron x-ray diffraction and Raman measurements show that this unique hydrogen-bearing compound that can be synthesized at 4.2 GPa and 300 K, quenched at low temperatures to atmospheric pressure, and retained up to 90 K on subsequent warming.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Turning a pyroelectric infrared motion sensor into a high-accuracy presence detector by using a narrow semi-transparent chopper

Pyroelectric infrared (PIR) sensors are the most popular presence detectors. However, their applications are limited to motion detection only, as the pyroelectric sensing element is only sensitive to radiated heat power fluctuation. Here, this letter reports a chopped PIR (C-PIR) presence sensor, capable of detecting both the stationary and the moving occupants at high accuracy by introducing a narrow semi-transparent optical chopper to shutter the incident radiation periodically. More importantly, even though the narrow chopper can efficiently shutter the unidirectional infrared (IR) power radiated by stationary occupants, it has near-zero influence on the omnidirectional power radiated from the ambient environment. Therefore, the voltage difference generated by the C-PIR sensor between occupied and unoccupied scenarios can be directly used for identifying the presence of stationary occupants with high-accuracy. For moving occupant detection, the optical chopper can barely affect the variation of the radiated power and thus lead to the same high-accuracy detection as the on-board PIR. An approximate theoretical model is created to illustrate the physics and dynamics of IR radiation shuttered by the optical chopper. Parametric studies, experimental characterization, and empirical analysis were performed to obtain the optimal setting of the chopper in terms of its thickness and chopping frequency. Experimental results reveal that the C-PIR sensor can detect stationary occupants for up to 4.0 m and moving occupants for up to 8.0 m, while maintaining an accuracy of 100%. The field of view of the C-PIR was found at 110° horizontally and 90° vertically, consistent with that of the on-board PIR sensor.

47 OTHER INSTRUMENTATION↗

Structural hierarchy as a key to complex phase selection in Al-Sm

Investigating the unknown structure of the complex cubic phase, previously observed to crystallize from melt-spun amorphous Al–10 at.% Sm alloy, we determine the structure in full site-occupancy detail, highlighting several critical structural features that govern the far-from-equilibrium phase selection pathway. Using an efficient genetic algorithm combining molecular dynamics, density functional theory, and x-ray diffraction, the structure is clearly identified as body-centered cubic Im¯3m (No. 229) with ~140 atoms per cubic unit cell and a lattice parameter of 1.4 nm. The complex structure is further refined to elucidate the detailed site occupancy, revealing full Sm occupancy on 6b sites and split Sm/Al occupancy on 16f sites. Based on the refined site occupancy associated with the experimentally observed phase, we term this phase ε–Al 60 Sm 11 (bcc), corresponding to the limiting situation when all 16f sites are occupied by Sm. However, it should be recognized that the range of solubility enabled by split occupancy at Sm sites is an important feature in phase selection under experimental conditions, permitting an avenue for transition with little or no chemical partitioning. Our analysis shows that the ε–Al 60 Sm 11 (bcc) exhibits a “3-6-6-1” first-shell packing around Sm centers on 16f sites, the same dominant motif exhibited by the undercooled liquid. Here, the coincident motif supports the notion that liquid/glass ordering at high undercooling may give rise to topological invariants between the noncrystalline and crystalline states that provide kinetic pathways to metastable phases that are not accessible during near-equilibrium processing.

36 MATERIALS SCIENCE↗

Nucleotide-binding flexibility in ultrahigh-resolution structures of the SRP GTPase Ffh

Two structures of the nucleotide-bound NG domain of Ffh, the GTPase subunit of the bacterial signal recognition particle (SRP), have been determined at ultrahigh resolution in similar crystal forms. One is GDP-bound and one is GMPPCP-bound. The asymmetric unit of each structure contains two protein monomers, each of which exhibits differences in nucleotide-binding conformation and occupancy. The GDP-bound Ffh NG exhibits two binding conformations in one monomer but not the other and the GMPPCP-bound protein exhibits full occupancy of the nucleotide in one monomer but only partial occupancy in the other. Thus, under the same solution conditions, each crystal reveals multiple binding states that suggest that even when nucleotide is bound its position in the Ffh NG active site is dynamic. Some differences in the positioning of the bound nucleotide may arise from differences in the crystal-packing environment and specific factors that have been identified include the relative positions of the N and G domains, small conformational changes in the P-loop, the positions of waters buried within the active site and shifts in the closing loop that packs against the guanine base. However, 'loose' binding may have biological significance in promoting facile nucleotide exchange and providing a mechanism for priming the SRP GTPase prior to its activation in its complex with the SRP receptor.

59 BASIC BIOLOGICAL SCIENCES↗

Comfort in High-Performance Homes in a Hot-Humid Climate

TO5 2.3.2: Large-Scale Temperature Study Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known about how space-conditioning systems are actually operating in the field and if these systems are meeting those standards. Unconventional space-conditioning systems may be necessary for low-load homes in the future. It is important to know how current systems are functioning in existing homes and to what temperatures occupants typically set the thermostats in their homes. The U.S. Department of Energy's Building America research team IBACOS set out to find some answers. By using low-cost data loggers and occupant surveys to monitor 37 single-family homes that have standard heating, ventilating, and air-conditioning (HVAC) equipment, the team gained insight into how sensitive occupants are to comfort in their homes relative to the ACCA and ASHRAE standards. This study focused on one climate zone (hot-humid); however, future studies may find differences among occupants- ideas of thermal comfort in other climate zones. Data were collected from installed sensors during a 2-month period from late August 2014 through late October 2014. The final aspect of this project was to review the business metrics associated with builders involved in a comfort and performance guarantee program. The results of this study-taken as an aggregate-show that the homes provided room-to-room temperature differences less than 6 degrees F 95% of the time. Temperature differences were less than 4 degrees F 80% of the time. Some homes showed better or worse performance. On average, two-story homes had a 3.3 degrees F temperature difference between rooms; single-story homes had an average of a 2.2 degrees F temperature difference between rooms. Occupants who did not use programmable thermostats had an average set point of 75 degrees F. Homes in which the thermostats were programmed with a setback schedule showed a median baseline temperature value of 74 degrees F and had a median afternoon setback of 75 degrees F. System runtime was analyzed and showed that the room-to-room temperature uniformity in some homes worsened during an on cycle, whereas the uniformity improved in other homes. That is, when the system was running, some rooms were receiving too much or too little air relative to the rest of the house, and the temperatures in those rooms were moving away from the temperatures of the other rooms in the house. Finally, analysis of the thermostat data shows a wide degree of variability among homes in the study. Interpretation of the measured data suggests that 21 occupants made no regular adjustments to the thermostats in their homes, seven had regular setbacks, seven showed varying setbacks, and 10 appeared to follow no pattern (with random adjustments). Ultimately, the data show that current systems are maintaining expected levels of comfort. As expected, it is more challenging to maintain a uniform temperature in all rooms of two-story homes, and future systems should address this issue. Furthermore, the data show that the majority of homes maintained relative humidity levels below 60% without any supplemental dehumidification

ACCA Manual RS↗

A tesselated probabilistic representation for spatial robot perception and navigation

The ability to recover robust spatial descriptions from sensory information and to efficiently utilize these descriptions in appropriate planning and problem-solving activities are crucial requirements for the development of more powerful robotic systems. Traditional approaches to sensor interpretation, with their emphasis on geometric models, are of limited use for autonomous mobile robots operating in and exploring unknown and unstructured environments. Here, researchers present a new approach to robot perception that addresses such scenarios using a probabilistic tesselated representation of spatial information called the Occupancy Grid. The Occupancy Grid is a multi-dimensional random field that maintains stochastic estimates of the occupancy state of each cell in the grid. The cell estimates are obtained by interpreting incoming range readings using probabilistic models that capture the uncertainty in the spatial information provided by the sensor. A Bayesian estimation procedure allows the incremental updating of the map using readings taken from several sensors over multiple points of view. An overview of the Occupancy Grid framework is given, and its application to a number of problems in mobile robot mapping and navigation are illustrated. It is argued that a number of robotic problem-solving activities can be performed directly on the Occupancy Grid representation. Some parallels are drawn between operations on Occupancy Grids and related image processing operations.

Elfes, Alberto↗

Vertical Drop Testing and Analysis of the WASP Helicopter Skid Gear

Human occupant modeling and injury risk assessment have been identified as areas of research for improved prediction of rotorcraft crashworthiness within the NASA Aeronautics Program's Subsonic Rotary Wing Project. As part of this effort, an experimental program was conducted to assess the impact performance of a skid gear for use on the WASP kit-built helicopter, which is marketed by HeloWerks, Inc. of Hampton, Virginia. Test data from a drop test at an impact velocity of 8.4 feet-per-second were used to assess a finite element model of the skid gear test article. This assessment included human occupant analytic models developed for execution in LS-DYNA. The test article consisted of an aluminum skid gear mounted beneath a steel plate. A seating platform was attached to the upper surface of the steel plate, and two 95th percentile Hybrid III male Aerospace Anthropomorphic Test Devices (ATDs) were seated on the platform and secured using a four-point restraint system. The goal of the test-analysis correlation is to further the understanding of LS-DYNA ATD occupant models and responses in the vertical (or spinal) direction. By correlating human occupant experimental test data for a purely vertical impact with the LS-DYNA occupant responses, improved confidence in the use of these tools and better understanding of the limitations of the automotive-based occupant models for aerospace application can begin to be developed.

Fuchs, Yvonne T.↗

Vertical Drop Testing and Analysis of the WASP Helicopter Skid Gear

Human occupant modeling and injury risk assessment have been identified as areas of research for improved prediction of rotorcraft crashworthiness within the NASA Aeronautics Program s Subsonic Rotary Wing Project. As part of this effort, an experimental program was conducted to assess the impact performance of a skid gear for use on the WASP kit-built helicopter, which is marketed by HeloWerks, Inc. of Hampton, Virginia. Test data from a drop test at an impact velocity of 8.4 feet-per-second were used to assess a finite element model of the skid gear test article. This assessment included human occupant analytic models developed for execution in LS-DYNA. The test article consisted of an aluminum skid gear mounted beneath a steel plate. A seating platform was attached to the upper surface of the steel plate, and two 95th percentile Hybrid III male Aerospace Anthropomorphic Test Devices (ATDs) were seated on the platform and secured using a four-point restraint system. The goal of the test-analysis correlation is to further the understanding of LS-DYNA ATD occupant models and responses in the vertical (or spinal) direction. By correlating human occupant experimental test data for a purely vertical impact with the LS-DYNA occupant responses, improved confidence in the use of these tools and better understanding of the limitations of the automotive-based occupant models for aerospace application can begin to be developed.

Fuchs, Yvonne T.↗