Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational adaptability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

The Challenges of Repository Operation in an Existing Mine - 19339

A generally accepted principle related to long term management of radioactive waste/ spent fuel is the isolation in a geological repository. In Germany, the disposal operation of low-level waste (LLW) and intermediate-level waste (ILW) started in the Asse II mine in 1967 and in the former German Democratic Republic in the Morsleben repository in 1971. After the German reunification, the responsibility for the existing sites changed several times until the Bundesgesellschaft fuer Endlagerung (BGE) became new license holder for both sites in 2017. The BGE is responsible to carry out the operative tasks of searching for a high-level waste (HLW) repository, the planning and construction of the Konrad repository for the emplacement of low- and intermediate-level waste (LILW), the operation of the Asse II mine including the retrieval of the emplaced waste, and the preparation for the closure of the Morsleben repository. Nevertheless, the challenges of repository operation in an existing mine have not changed in all these years, as the regulatory framework is mainly written for Nuclear Power Plants (NPPs) and is difficult to adapt for a repository mine. In particular, conditions in a mine are substantially different from 'clean' above-ground nuclear installations. Dust due to mining activities, relatively high temperatures, and a corrosive atmosphere in a salt mine might be present. Therefore, the usability of the repository for several decades during the different operational phases, i.e. planning, construction, emplacement, and closure, can only be ensured by continuous maintenance. Furthermore, the atomic law is applicable for above-ground facilities and the mining law for mines of every description. The difficulty of geological repositories is to ensure that both laws are going to be applied above and below ground with no regulatory framework tailored especially for such sites. A special case is the Asse II mine where the mining law was applied from the very beginning, before the atomic law needed to be established later on and now requires the retrieval of the radioactive waste before decommissioning. In this presentation, similarities and differences in the legal framework of the repositories in the responsibility of BGE and some operational experiences throughout the years are described. This applies to the radiation protection regime, the excavation ratio, the host rock stability and the backfilling concepts of the mining areas. Further challenges arise from the demonstration of long term safety according to the state-of-the-art of science and technology for either existing repositories/ mines or those under construction or planned. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-Time, Adaptive Radiological Anomaly Detection and Isotope Identification Using Non-Negative Matrix Factorization

Spectroscopic anomaly detection and isotope identification algorithms are integral components in nuclear nonproliferation applications such as search operations. The task is especially challenging in the case of mobile detector systems because the observed gamma-ray background changes more than for a static detector system, and a pretrained background model can easily find itself out of domain. The result is that algorithms may exceed their intended false alarm rate or sacrifice detection sensitivity to maintain the desired false alarm rate. Non-negative matrix factorization (NMF) is a powerful tool for spectral anomaly detection and identification, but, like many similar algorithms that rely on data-driven background models, in its conventional implementation, it is unable to update in real time to account for environmental changes that affect the background spectroscopic signature. Here, we have developed a novel NMF-based algorithm that periodically updates its background model to accommodate changing environmental conditions. The adaptive NMF algorithm involves fewer assumptions about its environment, making it more generalizable than existing NMF-based methods while maintaining or exceeding detection performance on simulated and real-world datasets.

Anomaly detection↗

Fuel-Based Nash Bargaining Approach for Adaptive Signal Control in an N -Player Cooperative Game

This paper presents a fuel-based game-theoretic approach for adaptive signal control. Our controller applies Nash bargaining (NB) in an n-player cooperative game to identify optimal phasing splits considering future traffic demands. The fuel-based NB controller utilizes an objective function that combines operational measures (delays and stops) with fuel consumption measures at intersections. The proposed controller was encoded in Python and then implemented and evaluated in a VISSIM microscopic traffic simulation model in an intersection with increasing volumes. The performance of the NB controller was compared to a traditional actuated control as the baseline. The results show that the NB controller was able to achieve superior environmental gains with a 17% saving in fuel consumption and a 17% reduction in CO emissions. In addition, the proposed controller was capable of maintaining acceptable operational conditions as it achieved a 20% reduction in delay, 8% reduction in the number of stops, and 8% reduction in queue lengths compared to the actuated controller. Compared to similar studies that applied NB for adaptive signal control, our fuel-based NB controller stands out as a promising approach to significantly improve fuel consumption at signalized intersections.

Engineering↗

Adaptive Data-Driven Model Predictive Control for Heat Pipe Microreactors

To establish a technical basis for self-regulating microreactors, a model predictive control (MPC) system is investigated to proactively respond to anomalies and disturbances in anticipation of potential deviations from operating setpoints. Due to the difficulty of developing a physics-based surrogate model that can accurately match plant data in various operating conditions, machine learning algorithms are used in MPC, which allow for learning from both simulation and operation data, thus efficiently describing the targeted transient with arbitrary accuracy. However, one of the biggest concerns in applying ML algorithms like artificial neural networks (ANNs) is that the predictive capabilities of ANN are limited by training data. If there are gaps between the training and target domain, the accuracy of an ANN can degrade significantly when it is used to predict unseen data. To improve the predictive capability of ANN and enable a confident use of data-driven MPCs outside the training data, this study proposes an adaptive data-driven MPC framework. The system will monitor the discrepancy between plant responses and surrogate predictions, fine-tune the ANN-based surrogate when a large discrepancy is detected, and continue MPC operation with updated surrogates. The framework is demonstrated on a point kinetic model for microreactors. The hyperparameters of the update strategy, including layers to update, error thresholds, learning rate discount, and number of data points used for fine-tuning, are optimized so the simulated microreactor is able to follow changes in setpoint with the smallest of deviations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Protection schemes used in North American microgrids

This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Load Shedding Application Architecture and Bi-Level Predictive Estimator Algorithm

Increasing penetrations of distributed renewables are decreasing the effectiveness of traditional decentralized under-frequency load shedding (UFLS) schemes. As more distribution circuits begin to back-feed the transmission system, operation of traditional UFLS may exacerbate frequency instability. This paper presents the conceptual framework for a data-rich environment to coordinate UFLS across multiple distribution providers based on the laminar coordination framework in order to ensure optimal adaptive setting of UFLS relays. Communication and control are enabled through a distributed implementation of the IEC 61968-1 Common Information Model message bus structure. In addition to the proposed architecture, a novel adaptive UFLS scheme informed by a bi-level state estimator to create optimal relay setpoints is introduced. Initial simulation results are presented for the IEEE 14-bus test system on scenarios leading to mis-operation of traditional UFLS.

Anderson, Alexander A.↗

ACTIVE

The Automated Control Testbed for Integration, Verification, and Emulation (ACTIVE) framework is a software platform designed to support the optimized operation and management of a wide range of building types. It enables the development, testing, and validation of diverse control strategies, including AI-based, rule-based, and model-based approaches. The platform facilitates a seamless transition from simulation-based evaluation of control strategies to real-world field validation and deployment. ACTIVE supports the full building management lifecycle, encompassing data acquisition and management, system monitoring, optimized control, adaptive learning services, device dispatch and coordination, as well as advanced analytics and visualization. Together, these capabilities provide an integrated environment for improving building performance, operational efficiency, reducing energy cost, and reliability.

Smith, Robert [Oak Ridge National Laboratory (ORNL↗

Learned adaptive properties for mitigation of weight perturbations in embedded spiking networks

Recent years have seen an increased importance of neural network inference in edge-based scenarios, which impose size and power constraints requiring novel computing devices. These same edge scenarios may require operating over long periods of time, or exposure to extreme environments, resulting in a drift of neural network weights that cause degraded performance. In searching for ways to develop neural network approaches that perform robustly under these conditions, we propose a biologically-inspired mechanism for the dynamic adaptation of within-neuron parameters that is guided by a global context signal carrying information about perturbations and variability in incoming stimuli. Specifically, we demonstrate that adaptive voltage thresholds or neuronal time constants, when informed by a global context signal, can enable network-level mechanisms to recover from perturbed synaptic weights. Consistent with prior literature, the context-modulated approach is effective for recurrent, but not feedforward networks, by modulating network level dynamics. We demonstrate this approach successfully recovers performance in image classification tasks and spatiotemporal tracking tasks under idealized and Gaussian noise as well as for realistic perturbations from a memristive device when exposed to ionizing radiation. Finally, we discuss how this approach enables the design of robust and energy-efficient neuromorphic systems that perform well, even in resource-constrained scenarios with extreme environments such as edge processing.

context modulation↗

Methods and apparatuses for operating nuclear reactors and for determining power levels in the nuclear reactors

An apparatus may include two or more electrical conductors, one or more signal devices, and an analyzer. The one or more signal devices may be adapted to apply one or more signals to the two or more electrical conductors and receive one or more signals from the two or more electrical conductors. The analyzer may be adapted to determine power level in the nuclear reactor using at least one of the applied signals and at least one of the received signals. A method of determining power level in a nuclear reactor may include: measuring impedance values of two or more electrical conductors disposed in the nuclear reactor and using the measured impedance values to determine the power level. A method of operating a nuclear reactor may include: measuring the impedance values and using the measured impedance values to determine parameters of the nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wastewater treatment plant online monitoring and control

A method of operating a waste water treatment plant (WWTP) having at least one of an aerobic digester (AD) and a membrane bioreactor (MBR) is described. The method of operating AD is comprised of monitoring and controlling AD in real-time using an online extended Kalman filter (EKF) having a online dynamic model of AD. The EKF uses real-time AD measured data, and online dynamic model of AD to update adapted model parameters and estimate model based inferred variables for AD, which are used for AD control by AD control system having supervisory and low-level control layers. The method of operating MBR is similar to that of AD. The supervisory control ensures the WWTP satisfying the effluent quality requirement while minimize the operation cost. A WWTP having at least one of AD or MBR is disclosed. The method of operating a WWTP can be implemented using a computer.

Kumar, Aditya↗

Adaptive four-level modeling of laser cooling of solids

Laser cooling of rare-earth doped solids has been demonstrated across a wide range of material platforms, inspiring the development of simple phenomenological models such as the four-level model to elucidate the universal properties of laser cooling under various operating conditions. However, these models usually require the input of full absorption spectra that must be provided experimentally or by additional complicated atomic modeling. In this Letter, we propose that a four-level model, when extended to admit effective energy levels adaptive to the pumping photon energy, can accurately predict the cooling efficiency as a function of temperature and pumping frequency using only few inputs such as the absorption coefficient measured at a single frequency and temperature. Our model exploits the quasi-equilibrium properties of the excitation of rare-earth ions for the determination of the effective four energy levels. The model is validated against published experimental results for a span of materials including ytterbium/thulium-doped glass and crystals. With the verified model, we derive explicit expressions for the optimal frequency and the operating bandwidth of pumping lasers. Our model significantly simplifies the modeling process of laser cooling and is expected to stimulate further development of optical refrigeration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive differentiation and rapid evolution of a soil bacterium along a climate gradient

Significance Increasing evidence suggests that evolutionary processes frequently shape ecological patterns; however, most microbiome studies thus far have focused on only the ecological responses of these communities. By using parallel field experiments and focusing in on a model soil bacterium, we showed that bacterial “species” are differentially adapted to local climates, leading to changes in their composition. Furthermore, we detected strain-level evolution, providing direct evidence that both ecological and evolutionary processes operate on annual timescales. The consideration of eco-evolutionary dynamics may therefore be important to understand the response of soil microbiomes to future environmental change.

54 ENVIRONMENTAL SCIENCES↗

Climate and water resource change impacts and adaptation potential for US power supply

Power plants that require cooling currently (2015) provide 85% of electricity generation in the United States. These facilities need large volumes of water and sufficiently cool temperatures for optimal operations, and projected climate conditions may lower their potential power output and affect reliability. We evaluate the performance of 1,080 thermoelectric plants across the contiguous US under future climates (2035-2064) and their collective performance at 19 North American Electric Reliability Corporation (NERC) sub-regions. Joint consideration of engineering interactions with climate, hydrology and environmental regulations reveals the region-specific performance of energy systems and the need for regional energy security and climate-water adaptation strategies. Despite climate-water constraints on individual plants, the current power supply infrastructure shows potential for adaptation to future climates by capitalizing on the size of regional power systems, grid configuration and improvements in thermal efficiencies. Without placing climate-water impacts on individual plants in a broader power systems context, vulnerability assessments that aim to support adaptation and resilience strategies misgauge the extent to which regional energy systems are vulnerable. As a result, climate-water impacts can lower thermoelectric reserve margins, a measure of systems-level reliability, highlighting the need to integrate climate-water constraints on thermoelectric power supply into energy planning, risk assessments, and system reliability management.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Injection data analysis using material balance time for CO 2 storage capacity estimation in deep closed saline aquifers

Estimating the ultimate storage capacity of deep saline aquifers is important to address the formation potential to store the envisioned large volumes of CO 2 . Injection data (i.e. injection rate, bottomhole pressure, and cumulative injected volume of CO 2 ) are routinely recorded during storage operations. These data contain valuable information on the subsurface (e.g. the reservoir pore volume and the formation storage capacity) that can be extracted. In this paper, we present a two-step graphical technique to infer the pore volume and the ultimate storage capacity of closed saline aquifers by analyzing the available injection data. First, the pore volume is inferred through adapting the concept of the material balance time. Material balance time is an approximate superposition time function developed to interpret production data from oil and gas wells operating at variable pressure/rate conditions during the boundary-dominated flow period. Using material balance techniques, the ultimate storage capacity is then estimated through linear extrapolation of the average pressure trend to the maximum allowable pressure the formation can withstand. The average pressure is not available in practice, but is can be obtained from the injection data. Two approaches are presented in this study to calculate the average pressure; namely the rigorous and the approximate approaches. Unlike the rigorous approach, the approximate approach does not require a prior knowledge of some reservoir properties (e.g. relative permeability, absolute permeability, formation porosity and thickness) to calculate the average pressure. To investigate its potential and reliability in analyzing CO 2 injection data, the proposed technique is applied to four synthetic cases representing different well operating conditions. Results indicate that the approximate approach consistently overestimates the actual (simulated) storage capacity as compared to the rigorous approach. The agreement - between the inferred and the simulated reservoir pore volume, and between the analytical and numerical estimates of storage capacity - validates the potential application of the technique to CO 2 storage in closed saline aquifers. The technique is further substantiated through application to a field data set utilized from a commercial-scale geological storage (CGS) project. Finally, field data interpretation shows that the proposed technique can be utilized to identify the degree of hydraulic continuity and reservoir compartmentalization within a target formation by interpreting the corresponding pressure and rate responses.

02 PETROLEUM↗

Introduction: Neuromorphic Materials

The explosive growth in data collection and the need to process it efficiently, as well as the desire to automate increasingly complex tasks in transportation, medical care, manufacturing, security and many other fields have motivated a growing interest in neuromorphic computing. Unlike the binary, transistorbased ON/OFF logic gates and separate logic and memory functionalities employed in digital computing, neuromorphic computing is inspired by animal brains that use interconnected synapses and neurons to perform processing, storage and transmission of information at the same location, while only consuming ~20 W or less of power. Motivated by the brain’s efficiency, adaptability, self-learning and resiliency qualities, neuromorphic computing can be broadly defined as an approach to processing and storing information using hardware and algorithms inspired by models of biological neural systems. Present research in neuromorphic computing encompasses approaches that vary significantly in their degree of neuro-inspiration, from systems that only incorporate features such as asynchronous, event-driven operation or use crossbar arrays of non-volatile memory (NVM) elements to accelerate deep neural networks (DNNs), to designs that embrace the extreme parallelism, sparsity, reconfigurability, adaptability, complexity and stochasticity observed in nervous systems. The term ‘neuromorphic’ computing is often credited to Carver Mead, who in the 1980s investigated Si-based analog electronics to replicate functions of the animal retina. Earlier important advances in this field include the work of Frank Rosenblatt, who proposed the concept of the perceptron, Bernard Widrow, who used this concept to build one of the first analog neural networks, the Adaline and many other researchers (see ref. 6 for an historical perspective on neuromorphic computing). With the recent increase in the use of artificial intelligence and large language models, and rising concerns over the associated energy costs, interest in neuromorphic hardware has expanded rapidly. According to some estimates, driven largely by the drastic growth in the training use of artificial intelligence (AI) models using the current computing architectures, the energy cost of computing is projected to reach the energy supply worldwide by 2045. Furthermore, while this is not a realistic outcome, it means that, if more efficient computing technologies are not developed -- soon -- the world will soon become one where demand for energy and market constraints limit the continued increase of societal access to AI and cloud services from data centers. Data centers used for training and use of these models consume hundreds of terawatt hours of electricity, already past 4% of the US electricity demand.

Circuits↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Coordinated Control Strategy of a Battery Energy Storage System to Support a Wind Power Plant Providing Multi-Timescale Frequency Ancillary Services

With increasing penetrations of wind generation on electric grids, wind power plants (WPPs) are encouraged to provide frequency ancillary services (FAS); however, it is a challenge to ensure that variable wind generation can reliably provide these ancillary services. This paper proposes using a battery energy storage system (BESS) to ensure the WPPs' commitment to FAS. This method also focuses on reducing the BESS's size and extending its lifetime. In this paper, a state-machine-based coordinated control strategy is developed to utilize a BESS to support the obliged FAS of a WPP (including both primary and secondary frequency control). This method takes into account the operational constraints of the WPP (e.g., real-time reserve) and the BESS (e.g., state of charge [SOC], charge and discharge rate) to provide reliable FAS. Meanwhile, an adaptive SOC-feedback control is designed to maintain SOC at the optimal value as much as possible and thus reduce the size and extend the lifetime of the BESS. In conclusion, the effectiveness of the control strategy is validated with an innovative, multi-area, interconnected power system simulation platform that can mimic realistic power systems operation and control by simulating real-time economic dispatch, regulating reserve scheduling, multi-area automatic generation control, and generators' dynamic response.

25 ENERGY STORAGE↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗