Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optimized Configurations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

The fast neutron source at UTK: a project with Massimo Salvatores

This article is dedicated to the memory of Massimo Salvatores and offers an overview of the history of the design of the Fast Neutron Source (FNS) flexible experiment system at the University of Tennessee. Our collaboration with Massimo set much of the over-arching design goals and inspired the concept that we have today. The decision to design the FNS as a subcritical assembly rather than a critical one stems back to discussions with Massimo Salvatores and his advocacy for subcritical Accelerator Driven Systems (ADS) which coincides with lower licensing time, costs and greater safety for a university-operated nuclear experimental facility. The second contribution of Massimo to the design concept of the FNS was the direct instruction to design the FNS as an extremely flexible facility. This article provides an update on the current design concept and discusses the future innovations in design optimization of flexible, re-configurable nuclear experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Programmable-trajectory ultrafast flying focus pulses

“Flying focus” techniques produce laser pulses with dynamic focal points that travel distances much greater than a Rayleigh length. The implementation of these techniques in laser-based applications requires the design of optical configurations that can both extend the focal range and structure the radial group delay. This article describes a method for designing optical configurations that produce ultrashort flying focus pulses with programmable-trajectory focal points. The method is illustrated by several examples that employ an axiparabola for extending the focal range and either a reflective echelon or a deformable mirror-spatial light modulator pair for structuring the radial group delay. The latter configuration enables rapid exploration and optimization of flying foci, which could be ideal for experiments.

47 OTHER INSTRUMENTATION↗

Phase II Final Report Computer Optimization of Electron Guns

This program implemented advanced computer optimization into an adaptive mesh, finite element, 3D, charged particle code. The routines can optimize electron gun performance to achieve a specified current, beam size, and perveance. It can also minimize beam ripple and electric field gradients. The magnetics optimization capability allows design of coil geometries and magnetic material configurations to achieve a specified axial magnetic field profile. The optimization control program, built into the charged particle code Beam Optics Analyzer (BOA) utilizes a 3D solid modeling package to modify geometry using design tables. Parameters within the graphical user interface (currents, voltages, etc.) can be directly modified within BOA. The program implemented advanced post processing capability for the optimization routines as well as the user. A Graphical User Interface allows the user to set up goal functions, select variables, establish ranges of variation, and define performance criteria. The optimization capability allowed development of a doubly convergent multiple beam gun that could not be designed using previous techniques.

43 PARTICLE ACCELERATORS↗

ePLAS Development for Jet Modeling and Applications

Plasma jets provide an alternate approach to the creation of high energy density laboratory plasmas (HEDLP). For the Plasma Liner Experiment (PLX), typically 30 partially ionized argon jets, produced with mini-rail guns, will be focused into a central volume for subsequent magnetic compression into high density plasma liners that can reach high (0.1 Mbar) peak pressures upon stagnation. The jets are typically 2.5 cm in radius traveling at Mach number 30. Ultimate success will require optimized tuning of the rail configurations, the nozzles injecting the gases, and the careful implementation of pre-ionization. The modeling of plasma jet transport is particularly challenging, due the large space (100 sq cm) and time scales (microseconds) involved. Even traditional implicit methods are insufficient, due to the usual need to track electrons explicitly on the mesh. Wall emission and chemistry must be managed, as must ionization of the jet plasma. Ions in the jets are best followed as particles to account properly for collisions upon jet merger. This Phase I Project developed the code ePLAS to attack and successfully surmount many of these challenges. It invented a new 'super implicit' electromagnetic scheme, using implicit electron moment currents that allowed for modeling of jets over multi-cm and multi-picoseconds on standard, single processor 2 GHz PCs. It enabled merger studies of two jets, in preparation for the multi-jet merger problem. The Project explored particle modeling for the ions, and prepared for the future addition of a grid-base jet ion collision model. Access was added to tabular equations of state for the study of ionization effects in merging jets. The improved code was discussed at the primary plasma meetings (IEEE and APS) during the Project period. Collaborations with National Laboratory and industrial partners were nurtured. Code improvements were made to facilitate code use. See: http://www.researchapplicationscorp.com. The ePLAS code enjoys EAR99 export control treatment, permitting distribution to most foreign countries without a license.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance Verification of Production-Scalable Energy-Efficient Solutions: Winchester/Camberley Homes Mixed-Humid Climate

Winchester/Camberley Homes with the Building America program and its NAHB Research Center Industry Partnership collaborated to develop a new set of high performance home designs that could be applicable on a production scale. The new home designs are to be constructed in the mixed humid climate zone four and could eventually apply to all of the builder's home designs to meet or exceed future energy codes or performance-based programs. However, the builder recognized that the combination of new wall framing designs and materials, higher levels of insulation in the wall cavity, and more detailed air sealing to achieve lower infiltration rates changes the moisture characteristics of the wall system. In order to ensure long term durability and repeatable successful implementation with few call-backs, this report demonstrates through measured data that the wall system functions as a dynamic system, responding to changing interior and outdoor environmental conditions within recognized limits of the materials that make up the wall system. A similar investigation was made with respect to the complete redesign of the heating, cooling, air distribution, and ventilation systems intended to optimize the equipment size and configuration to significantly improve efficiency while maintaining indoor comfort. Recognizing the need to demonstrate the benefits of these efficiency features, the builder offered a new house model to serve as a test case to develop framing designs, evaluate material selections and installation requirements, changes to work scopes and contractor learning curves, as well as to compare theoretical performance characteristics with measured results.

2X6 WALLS↗

CO{sub 2} Capture by Sub-ambient Membrane Operation

The main objective of the project was to develop a CO{sub 2} capture process based on sub-ambient temperature operation of a hollow fiber membrane. The program aims to reach the eventual DOE program goal of > 90% CO{sub 2} capture from existing PC fired power plants with < 35% increase in the cost of electricity. The project involves closed-loop testing of commercial fiber bundles under simulated process conditions to test the mechanical integrity and operability of membrane module structural component under sub ambient temperature. A commercial MEDAL 12” bundle exhibited excellent mechanical integrity for 2 months. However, selectivity was ~25% lower than expected at sub-ambient conditions. This could be attributed to a small feed to permeate leak or bundle non-ideality. To investigate further, and due to compressor flow limitations, the 12” bundle was replaced with a 6” bundle to conduct tests with lower permeate/feed ratios, as originally planned. The commercial 6” bundle was used for both parametric testing as well as long-term stability testing at sub-ambient conditions. Parametric studies were carried out both near the start and end of the long-term test. The parametric studies characterized membrane performance over a broad range of feed conditions: temperature (-25°C to -45°C), pressure (160 psig to 200 psig), and CO{sub 2} feed concentration (18% to 12%). Performance of the membrane bundle was markedly better at lower temperature (-45ºC), higher pressure (200 psig) and higher CO{sub 2} feed concentration (18%). The long-term test was conducted at these experimentally determined “optimum” feed conditions. Membrane performance was stable over 8 months at sub-ambient temperature operation. The experimentally measured high performance of the membrane bundle at sub-ambient operating conditions provides justification for interest in sub-ambient membrane processing of flue gas. In a parallel activity, the impact of contaminants (100 ppm SOx and NOx) on membrane performance was tested in the laboratory with membrane minipermeators. NO permeance is intermediate between CO{sub 2} and N{sub 2}; while both SO{sub 2} and NO{sub 2} are more permeable than CO{sub 2} at cold condition. This implies that SO{sub 2} and NO{sub 2} will be efficiently removed with CO{sub 2} into the membrane permeate in the proposed cold membrane process. Calculations were performed by Air Liquide Engineering (ALE) to estimate capture costs based on the proposed sub-ambient temperature membrane process for 90% CO{sub 2} capture from an air- fired coal power plant delivering 550 MW net electricity. Membrane performance in the process simulation was defined by the final parametric test results. This analysis involved refining the process simulation model, obtaining relevant capital cost estimates and using these to estimate a 20-year levelized cost of electricity (LCOE). A sensitivity analysis shows CO{sub 2} capture specific energy requirements of 216-242 kwh/T CO{sub 2} captured. The LCOE estimating methodology followed DOE/NETL study 2010/1397. This analysis indicates increases in LCOE between 48% and 53%. For most equipment, the budgetary capital cost estimates are expected to be valid within ± 20%. The most significant capital costs are due to the (i) feed compression and associated gas pretreatment and (ii) membrane system. For both items, there is a realistic chance for cost reductions in the immediate future (0-5 years) as well as long term reductions. The process continues to hold promise with anticipated cost reductions in compression and membrane operations. In particular, membrane costs could be reduced significantly by increased production volume (economy of scale) as well as optimization of bundle size and configuration for this application. PFD definition for a potential field test has been completed through (i) simulation work at DRTC, (ii) discussions with compressor manufacturers and (iii) a field visit to t e NCCC, Wilsonville, AL. The PC4 facility at the NCCC is a suitable site for a 0.1 MW scale test.

54 ENVIRONMENTAL SCIENCES↗

Spectroscopic research of Lambda hypernuclei up to medium-heavy mass region with the (e,e'K + ) reaction

In 2009 (August-November), the E05-115 experiment was carried out at JLab to investigate L hypernuclei in the wide mass region up to A = 52 ($7\atop{Λ}$He, $10\atop{Λ}$Be, $12\atop{Λ}$B and $52\atop{Λ}$V) with the (e,e'K + ) reaction. This is the first attempt to investigate a medium heavy L hypernucleus with the (e,e'K + ) reaction. Experimentally, it is difficult to measure heavier L hypernuclei as background rates of particles which originate from electromagnetic processes are roughly in proportion to Z2 (Z: target proton number) in the (e,e'K + ) experiment. To perform the experiment, many experimental techniques have been developed and introduced such as optimization of the electron spectrometer configuration (tilt method), clean kaon identification, particle tracking under high multiplicity environment, precise energy scale calibration and so on. In the present thesis, experimental results of the elementary process of p(e,e'K + )L, L hypernuclei of $7\atop{Λ}$He, $10\atop{Λ}$Be, $12\atop{Λ}$B and $52\atop{Λ}$V are shown. Elementary processes of the electroproduction of L and Σ 0 , p(e,e'K + )L, Σ 0 were used for the absolute energy scale calibration of our spectrometer systems. A careful Monte Carlo simulation shows that the binding energy can be obtained with a systematic error of 0.11 MeV with our energy scale calibration method. A study of the elementary process of L is important to understand L hypernuclei as it is essential for theoretical calculations of L hypernuclei. The differential cross section of the p(e,e'K + )L reaction at the small K + scattering angle (theta-CM/gamma-K approx. 15.5°), the small Q 2 (approx 0.01 [GeV/c] 2 ) and the total energy of W = 1.92 GeV, where no experimental data exists was obtained to be 235 ± 13$+28\atop{-24}$ nb/sr. The ground state (1/2 + ) binding energy of $7\atop{Λ}$He was already measured in JLab E01-011 (2005). In the present work, the binding energy of 1/2 + state was determined to be B Λ = 5.55 ± 0.10 ±0.11 MeV with five times more statistic and smaller systematic errors than those of the previous experiment. The ground state binding energy is important to test the phe- nomenologically introduced CSB (Charge Symmetry Breaking) LN interaction for A = 7, T = 1 hypernuclear systems. In addition, a peak which is interpreted as 3/2 + and 5/2 + states was measured to be B Λ = 3.65 ± 0.20 ±0.11 MeV with sufficient statistic for the first time. Only three events of the ground state of $10\atop{Λ}$ Be had been observed in the emulsion experiments. The present experiment is the first spectroscopic measurement of 10/L-Be, and the detailed structures have been successfully measured for the first time. About three times better energy resolution was achieved in the present experiment (0.78 MeV in FWHM) than that of the mirror L hy- pernucleus, $10\atop{Λ}$B (2.2 MeV in FWHM) which was measured in the (π + ,K + ) experiment at KEK. The result of the ground state binding energy was obtained to be B Λ = 8.55 ± 0.07 ± 0.11 MeV which serves also to discuss about the CSB effect in the LN interaction. $12\atop{Λ}$B has been measured with the world best energy resolution of 0:5 MeV (FWHM) among the reaction spectroscopy of L hypernuclei. The results of $12\atop{Λ}$B are compared with the experimental results in the previous experiments to confirm the consistency. Furthermore, the obtained ground state binding energies of $12\atop{Λ}$B (B Λ = 11.38 ± 0.02 ± 0.11 MeV) and $52\atop{Λ}$V (B Λ = 21.88 ± 0.59 ± 0.11 MeV) indicate that the reported value of 12/L-C which has been used as a reference of binding energy measurements for the (π + ,K + ) experiments would be shallower by ~ 0.5 MeV. A pilot study for investigation in the medium-heavy mass region with the (e,e'K + ) experiment was performed by measuring $52\atop{Λ}$V. The ground state binding energy of $52\atop{Λ}$V has been measured, overcoming high multiplicity environment. The results are discussed with the ex- perimental results of 51/L-V measured at KEK. The present result is the first measurement of L's binding energy of the ground state without the emulsion reference in the medium-heavy mass region, which could be a substantial improvement in the information needed for understanding the single particle potential of L. In the present experiment, L hypernuclear measurement with a small systematic error of ~ 0.1 MeV by the (e,e'K + ) reaction has been established. Moreover, the present work opened a door to the heavier L hypernuclear measurement with the (e,e'K + ) reaction in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct Air Capture Case Studies: Solvent System

This case study provides cost and performance estimates for a solvent-based direct air capture (DAC) system at varying scales. The performance of the DAC system is largely based upon vendor performance while the costs of the system were developed as independently as possible. This study is representative of an example DAC system configuration and is not an optimized design.

42 ENGINEERING↗

Voltage Optimization

Voltage optimization refers to a volt-var optimization technique which was originally designed to minimize energy consumption and improve end-use efficiency on the distribution system. This reduces source voltage at a substation, which lowers generation demand, reduces system losses, and improves system stability. This has been the conventional implementation of voltage optimization: focusing on regulation of voltages throughout the distribution system via coordinated adjustments of load tap changers, line-voltage regulators, switched shunt compensation, and the targeted placement of new shunt compensation. These methods have received increased focus following a growth in distributed-energy resources (DERs) interconnecting at the distribution level, given their developing capability to participate in voltage regulation. This is paired with the intermittency challenges they pose, load imbalances, and voltage fluctuations. Voltage optimization has long been an area of extensive research within the distribution system, with various strategies and philosophies demonstrating a range of effects. The conventional focus on the distribution system owes to the typical operation of transmission systems, which assumes firm local resources and flows strictly from generation resources to loads. The strategies employed in distribution have also been optimized for this typically radial configuration and operation of the distribution system.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Reservoir Characterization and Techno-Economic Analysis of Enhanced Geothermal and Closed-Loop Systems in the Wattenberg Field of the Denver-Julesburg Basin, Colorado

This report provides details of reservoir characterization and techno-economic analysis for enhanced geothermal systems and closed-loop geothermal systems in the Denver-Julesburg Basin Wattenberg area. The analysis contributes to the Geothermal Limitless Approach to Drilling Efficiencies (GLADE) project, a multi-institutional research initiative focused on advancing geothermal energy development by reducing drilling costs and improving the rate of penetration. The GLADE project brings together national laboratories, academic institutions, and industry partners, including the U.S. Department of Energy's Geothermal Technologies Office, Occidental Petroleum, the National Laboratory of the Rockies (NLR), Los Alamos National Laboratory, Colorado School of Mines, Louisiana State University, Texas A&M University, and several drilling technology companies. As part of this effort, NLR developed and applied slender-body theory modeling tools and the GEOPHIRES simulator to support techno-economic analysis. The slender-body theory wellbore simulator evaluated thermal performance in U-loop, Eavor-type multilateral, and enhanced geothermal system well configurations. Results indicated that an optimized single U-loop design delivers an outlet temperature of 168.8 degrees Celsius,stabilizing at a final outlet temperature of 135.3 degrees Celsius. Heat production also improved significantly, with an average thermal output of 16.9 MWth and a final thermal output of 11.0 MWth. These results provided critical baseline data for selecting optimized systems for techno-economic analysis. Building on these outputs, NLR applied the GEOPHIRES techno-economic simulator to estimate the levelized cost of electricity for both the Eavor multilateral and enhanced geothermal systems. The sensitivity analysis showed that drilling costs exert a particularly strong impact on the levelized cost of electricity of multilateral systems. Therefore, advances in drilling technology and improved drilling rates could yield significant gains in the economic performance of these systems. In this context, the GLADE project directly supports the U.S. Department of Energy's mission to reduce the cost of geothermal energy and accelerate the deployment of next-generation geothermal technologies.

15 GEOTHERMAL ENERGY↗

NREL Price Series Developed for the ARPA-E FLECCS Program

The price data for four regions (CAISO, ERCOT, MISO-W, and PJM-W) are developed using the ReEDS to PLEXOS conversion as described in (Gagnon et al. 2020). The reference ReEDS case chosen is based on the 2020 Standard Scenario Mid-case, which uses the 2020 ReEDS model version (Cole et al. 2020; Ho et al. 2021). All ReEDS model inputs use 2020 Standard Scenarios Mid-case assumptions except for CO2 prices, which are implemented as linearly increasing CO2 price trajectories beginning at $0/tCO2 in 2020 and ending at either $100/tCO2 or $150/tCO2 in 2035 to dive capacity expansion towards a low-carbon system that could support CCS deployment. However, these scenarios also prohibit CCS deployment in this time frame so that resulting price data are not influenced by the deployment and operation of CCS itself. Implementing the ReEDS to PLEXOS conversion tool, PLEXOS is then simulated using the 2035 ReEDS infrastructure for both CO2 price scenarios, with the following model version and setup: PLEXOS Version: 8.2 Solver: Xpress-MP 35.01.01 Mixed integer optimization relative gap 1% System configuration: • Total number of nodes: 134 (consistent with ReEDS balancing areas) • Line losses enforced using piecewise linear approximation • Energy dump was enabled Price data is aggregated to the ISO/RTO level using load-weighted averages. References: Cole, Wesley, Sean Corcoran, Nathaniel Gates, Daniel Mai, Trieu, and Paritosh Das. 2020. “2020 Standard Scenarios Report: A U.S. Electricity Sector Outlook.” NREL/TP-6A20-77442. Golden, CO: National Renewable Energy Laboratory. https://www.nrel.gov/docs/fy21osti/77442.pdf. Gagnon, Pieter, Will Frazier, Elaine Hale, and Wesley Cole. 2020. “Cambium Documentation: Version 2020.” NREL/TP-6A20-78239. National Renewable Energy Lab. (NREL), Golden, CO (United States). https://doi.org/10.2172/1734551. Ho, Jonathan, Jonathon Becker, Maxwell Brown, Patrick Brown, Ilya (ORCID:0000000284917814) Chernyakhovskiy, Stuart Cohen, Wesley (ORCID:000000029194065X) Cole, et al. 2021. “Regional Energy Deployment System (ReEDS) Model Documentation: Version 2020.” NREL/TP-6A20-78195. Golden, CO: National Renewable Energy Laboratory. https://doi.org/10.2172/1788425.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-speed, intra-system networks

Recently, engineers have been studying on-payload networks for fast communication paths. Using intra-system networks as a means to connect devices together allows for a flexible payload design that does not rely on dedicated communication paths between devices. In this manner, the data flow architecture of the system can be dynamically reconfigured to allow data routes to be optimized for the application or configured to route around devices that are temporarily or permanently unavailable. To use intra-system networks, devices will need network controllers and switches. These devices are likely to be affected by single-event effects, which could affect data communication. In this paper we will present radiation data and performance analysis for using a Broadcom network controller in a neutron environment.

42 ENGINEERING↗

Auto-Calibration and Control Strategy Determination for a Variable-Speed Heat Pump Water Heater Using Optimization

This paper introduces applications of the GenOpt optimizer coupled with a vapor compression system model for auto-calibration and control strategy determination towards the development of a variable-speed ground-source heat pump water heating unit. The GenOpt optimizer can be linked with any simulation program using input and output text files. It effectively facilitates optimization runs. Using our GenOpt wrapper program, we can flexibly define objectives for optimizations, targets, and constraints. Those functionalities enable running extensive optimization cases for model calibration, configuration design and control strategy determination. In addition, we describe a methodology to improve prediction accuracy using functional calibration curves. Using the calibrated model, we investigated control strategies of the ground-source heat pump water heater, considering multiple control objectives, covering the entire operation range.

Shen, Bo↗

New Whole-House Solutions Case Study: Winchester Homes and Camberly Homes

The Partnership for Home Innovation team worked with the builder to develop a new set of high performance home designs—including advanced wall and HVAC systems—that could be applicable on a production scale. The new home designs are to be constructed in the mixed humid climate zone and could eventually apply to all of the builder's home designs to meet or exceed future energy codes or performance-based programs. However, the builder recognized that the combination of new wall framing designs and materials, higher levels of insulation in the wall cavity, and more detailed air sealing to achieve lower infiltration rates changes the moisture characteristics of the wall system. In order to ensure long term durability and repeatable successful implementation with few call-backs, this report demonstrates through measured data that the wall system functions as a dynamic system, responding to changing interior and outdoor environmental conditions within recognized limits of the materials that make up the wall system. A similar investigation was made with respect to the complete redesign of the heating, cooling, air distribution, and ventilation systems intended to optimize the equipment size and configuration to significantly improve efficiency while maintaining indoor comfort. Recognizing the need to demonstrate the benefits of these efficiency features, the builder offered a new house model to serve as a test case to develop framing designs, evaluate material selections and installation requirements, changes to work scopes and contractor learning curves, as well as to compare theoretical performance characteristics with measured results.

2x6 walls↗

Online Measurement of the Energy Spread of Multi-Turn Beam in the Fermilab Booster at Injection

We have developed a computer program interfaced with the ACNET environment of Fermilab accelerators to measure energy spread of the proton beam from the LINAC at an injection into the Booster. It uses a digitizing oscilloscope and provides users an ability to configure the scope settings for optimal data acquisition from a resistive wall current monitor. When the program is launched, a) a one shot timeline is generated to initiate beam injection into the Booster, b) a gap of about 40 ns is produced in the injected beam using a set of fast kickers, c) collects line charge distribution data from the wall current monitor for the first 200 μs from the injection and d) performs complete data analysis to extract full beam energy spread of the beam. The program also gives the option to store the data for offline analyses. We illustrate a case with an example. We also present results on beam energy spread as a function of beam intensity from recent measurements.

43 PARTICLE ACCELERATORS↗

Techno-economic Analysis of an Integrated Gasification Direct-Fired Supercritical CO2 Power Cycle

This presentation describes recent systems studies of a coal-fueled, oxy-fired direct supercritical CO2 (sCO2) power cycle, which inherently captures carbon for storage (CCS). In this plant, coal is gasified in an entrained flow gasifier, the syngas is cleaned and burned with oxygen and diluent sCO2 in the cycle’s oxy-combustor. This is followed by turbine expansion and recuperation of thermal energy in the exhaust. After water is condensed from the working fluid, some of the CO2 is exhausted for CCS, and the balance is compressed and heated in the recuperator for return to the combustor. The conceptual design and system model for the plant are discussed, including thermal integration between the sCO2 cycle and the gasifier, and optimization of the overall plant configuration and operating conditions. The capital cost, operating expenses, and cost of electricity (COE) are also estimated. Results show improved efficiency and COE relative to IGCC plants with CCS.

Weiland, Nathan↗