Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERMANENT MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

10MW Class Direct Drive HTS Wind Turbine: Cooperative Research and Development Final Report, CRADA Number CRD-08-00312

This paper summarizes the work completed under the CRADA between NREL and American Superconductor (AMSC). The CRADA combined NREL and AMSC resources to benchmark high temperature superconducting direct drive (HTSDD) generator technology by integrating the technologies into a conceptual wind turbine design, and comparing the design to geared drive and permanent magnet direct drive (PMDD) windturbine configurations. Analysis was accomplished by upgrading the NREL Wind Turbine Design Cost and Scaling Model to represent geared and PMDD turbines at machine ratings up to 10 MW and then comparing cost and mass figures of AMSC's HTSDD wind turbine designs to theoretical geared and PMDD turbine designs at 3.1, 6, and 10 MW sizes.

17 WIND ENERGY↗

Recycler Chromaticities and End Shims for NOvA at Fermilab

In era of NOvA operation, it is planned to slip-stack six on six Booster proton batches in the Recycler ring for a total intensity of 5 x 10{sup 13} protons/cycle. During the slip-stacking, the chromaticities are required to be jumped from (-2,-2) to (-20,-20). However, with the existing 2 families of powered sextupoles in the lattice, the chromaticities can only be adjusted to (-12,-12) from (-2,-2). On the other hand, the presently designed Recycler lattice for Nova replaces the 30 straight section with 8 'D-D half FODO cells'. With the limit of the feasible quad strength, 3 quads in a half-cell were used to obtain the working point under, and the maximum beta-functions in this section cannot be less than 80 m. In this paper, we re-designed the end shims of the permanent magnets in the ring lattice with appropriate quadrupole and sextupole components to meet both chromaticity and tune requirements. We are able to use 2 quads in a half cell in RR30 straight section within feasible quad strength. The maximum beta-functions are also lowered to around 55 m. The dynamic aperture tracking has been done using MAD to simulate the scenario of beam injection into the Recycler ring for Nova.

43 PARTICLE ACCELERATORS↗

Charge-state distributions of metallic electron cyclotron resonance plasmas

The authors have developed metallic ion beams in the energy range of a few keV to a few MeV using a low-energy ion-beam facility (LEIBF) consisting of a 10 GHz all-permanent-magnet electron cyclotron resonance (ECR) ion source placed on a high-voltage (200 kV) platform. The metallic vapors were achieved by plasma sputtering, using a micro-oven and volatile compounds to produce multiply charged ECR plasma. The ions were then extracted from the plasma and their energy and momentum were analyzed using a high-resolution dipole magnet. Charge-state distributions (CSDs) of three metallic ECR plasmas (Cu, Ni, and Sn) produced by different techniques are presented to help in using low-energy metallic ions for implantation. We present the CSD studies of metallic ECR plasma and highlight the physics of the process involved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Knot Undulator to Generate Linearly Polarized Photons with Low on-Axis Power Density

Heat load on beamline optics is a serious problem to generate pure linearly polarized photons in the third generation synchrotron radiation facilities. For permanent magnet undulators, this problem can be overcome by a figure-8 operating mode. But there is still no good method to tackle this problem for electromagnetic elliptical undulators. Here, a novel operating mode is suggested, which can generate pure linearly polarized photons with very low on-axis heat load. Also the available minimum photon energy of linearly polarized photons can be extended much by this method.

43 PARTICLE ACCELERATORS↗

Liquid metal alloy ion source based metal ion injection into a room-temperature electron beam ion source

We have carried out a series of measurements demonstrating the feasibility of using the Dresden electron beam ion source (EBIS)-A, a table-top sized, permanent magnet technology based electron beam ion source, as a charge breeder. Low charged gold ions from an AuGe liquid metal alloy ion source were injected into the EBIS and re-extracted as highly charged ions, thereby producing charge states as high as Au{sup 60+}. The setup, the charge breeding technique, breeding efficiencies as well as acceptance and emittance studies are presented.

43 PARTICLE ACCELERATORS↗

Development of a compact filament-discharge multi-cusp H{sup -} ion source

A 14 MeV medical cyclotron with the external ion source has been designed and is being constructed at China Institute of Atomic Energy. The H{sup -} ion will be accelerated by this machine and the proton beam will be extracted by carbon strippers in dual opposite direction. The compact multi-cusp H{sup -} ion source has been developed for the cyclotron. The 79.5 mm long ion source is 48 mm in diameter, which is consisting of a special shape filament, ten columns of permanent magnets providing a multi-cusp field, and a three-electrode extraction system. So far, the 3 mA/25 keV H{sup -} beam with an emittance of 0.3 {pi} mm mrad has been obtained from the ion source. The paper gives the design details and the beam test results. Further experimental study is under way and an extracted beam of 5 mA is expected.

43 PARTICLE ACCELERATORS↗

Electron cyclotron resonance ion sources in use for heavy ion cancer therapy

The use of electron cyclotron resonance (ECR) ion sources for producing ion beams for heavy ion cancer therapy has been established for more than ten years. After the Heavy Ion Medical Accelerator (HIMAC) at Chiba, Japan started therapy of patients with carbon ions in 1994 the first carbon ion beam for patient treatment at the accelerator facility of GSI was delivered in 1997. ECR ion sources are the perfect tool for providing the required ion beams with good stability, high reliability, and easy maintenance after long operating periods. Various investigations were performed at GSI with different combinations of working gas and auxiliary gas to define the optimal beam conditions for an extended use of further ion species for the dedicated Heidelberg Ion Beam Therapy (HIT) facility installed at the Radiological University Hospital Heidelberg, Germany. Commercially available compact all permanent magnet ECR ion sources operated at 14.5 GHz were chosen for this facility. Besides for {sup 12}C{sup 4+} these ion sources are used to provide beams of {sup 1}H{sub 3}{sup 1+}, {sup 3}He{sup 1+}, and {sup 16}O{sup 6+}. The final commissioning at the HIT facility could be finished at the end of 2006.

43 PARTICLE ACCELERATORS↗

Compact LINAC for deuterons

We are developing a compact deuteron-beam accelerator up to the deuteron energy of a few MeV based on room-temperature inter-digital H-mode (IH) accelerating structures with the transverse beam focusing using permanent-magnet quadrupoles (PMQ). Combining electromagnetic 3-D modeling with beam dynamics simulations and thermal-stress analysis, we show that IHPMQ structures provide very efficient and practical accelerators for light-ion beams of considerable currents at the beam velocities around a few percent of the speed of light. IH-structures with PMQ focusing following a short RFQ can also be beneficial in the front end of ion linacs.

43 PARTICLE ACCELERATORS↗

Broadband electromagnetic power harvester from vibrations via frequency conversion by impact oscillations

In this paper, we propose an electromagnetic power harvester that uses a transformative multi-impact approach to achieve a wide bandwidth response from low frequency vibration sources through frequency-up conversion. The device consists of a pick-up coil, fixed at the free edge of a cantilever beam with high resonant frequency, and two cantilever beams with low excitation frequencies, each with an impact mass attached at its free edge. One of the two cantilevers is designed to resonate at 25 Hz, while the other resonates at 50 Hz within the range of ambient vibration frequency. When the device is subjected to a low frequency vibration, the two low-frequency cantilevers responded by vibrating at low frequencies, and thus their thick metallic masses made impacts with the high resonance frequency cantilever repeatedly at two locations. This has caused it along with the pick-up coil to oscillate, relative to the permanent magnet, with decaying amplitude at its resonance frequency, and results in a wide bandwidth response from 10 to 63 Hz at 2 g. A wide bandwidth response between 10–51 Hz and 10–58 Hz at acceleration values of 0.5 g and 2 g, respectively, were achieved by adjusting the impact cantilever frequencies closer to each other (25 Hz and 45 Hz). A maximum output power of 85 μW was achieved at 5 g at 30 Hz across a load resistor, 2.68 Ω.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A comparison of efficiency-aware model-predictive control approaches for wave energy devices

In this study, we compare four different formulations of model predictive control that attempt to maximise electrical power generated by a wave energy converter (WEC). Control laws include (1) pure maximisation of mechanical power, (2) maximisation of mechanical power with a control penalty factor, (3) maximisation of electrical power using power conversion efficiency, and (4) maximisation of electrical power using the full electro-mechanical model of a system. For this study, a wave-to-wire model is developed for a floating spherical buoy connected to a permanent magnet synchronous generator. The performance of the controllers, including the mechanical and electrical power outputs, is compared in irregular wave conditions for the unconstrained and force-constrained scenarios. The results demonstrate that the controller designed to maximise mechanical power is not suitable for practical applications and may lead to negative electrical power output due to the non-ideal power take-off efficiency. Moreover, the replacement of the power take-off dynamics by the efficiency coefficient does not guarantee the maximum electrical power production.

16 TIDAL AND WAVE POWER↗

Knot undulator to generate linearly polarized photons with low on-axis power density

Heat load on beamline optics is a serious obstacle for devices designed to generate pure linearly polarized photons in third generation synchrotron radiation facilities. For permanent magnet undulators, this problem can be overcome by implementing a figure-eight design configuration. As yet there has been no good method to tackle this problem for electromagnetic elliptical undulators. Here, a novel design and operational mode is suggested, which can generate pure linearly polarized photons with very low on-axis heat load. Additionally, the minimum photon energy capability of linearly polarized photons can be significantly extended by this method.

43 PARTICLE ACCELERATORS↗

Advanced Lightweight HiE PMDD Generator for WTGs

Preliminary designs of advanced lightweight permanent magnet direct drive generators for offshore and “tall wind” onshore applications utilizing funding from DOE/EERE/WETO were developed by WEG, RTX, NREL and supporting partners. This work significantly reduces tower head mass, increases efficiency, reduces the rare earth content of the generator, and leads to additional turbine system benefits that improve competitiveness, such as the use of taller towers onshore and less expensive foundations (“hull”) for floating offshore. The end result is an approximately 10% reduction of LCOE in both cases, which could significantly improve competitiveness and support the EERE/DOE goal of promoting US manufacturing.

17 WIND ENERGY↗

Interaction Region Upgrades of e+ e- B-Factories

Both the PEP-II and KEKB B-Factories have plans to upgrade their Interaction Regions (IRs) in order to improve luminosity performance. Last summer PEP-II added cooling to the IR beam pipe in order to increase beam currents thereby raising the luminosity. In addition, PEP-II is working on a design that modifies the permanent magnets near the Interaction Point (IP) for an even higher luminosity increase. KEKB is also planning an improvement to their IR that will decrease the detector beam pipe radius. In addition, KEK has a design to increase the luminosity of KEKB to 1 x 10{sup 35} cm{sup -2} sec{sup -1} which includes changes to the IR. PEP-II is also investigating the feasibility of a 1 x 10{sup 36} cm{sup -2} sec{sup -1} luminosity design. I summarize these various upgrades and concentrate on issues common to the different designs.

43 PARTICLE ACCELERATORS↗

Efficient low-beta H-mode accelerating structures with PMQ focusing

We are developing high-efficiency room-temperature RF accelerating structures for beam velocities in the range of a few percent of the speed of light by merging two well-known ideas: H-mode cavities and the transverse beam focusing with permanent-magnet quadrupoles (PMQ). Combining electromagnetic 3-D modeling with beam dynamics simulations and thermal-stress analysis, we have found that the H-mode structures with PMQ focusing provide a very efficient and practical accelerator for light-ion beams of considerable currents. Such accelerating structures following a short RFQ can be used in the front end of ion linacs or in stand-alone applications such as a compact deuteron-beam accelerator up to the energy of a few MeV.

43 PARTICLE ACCELERATORS↗

Submersible Generator for Marine Hydrokinetics

A submersible generator was designed as a distinct and critical subassembly of marine hydrokinetics systems, specifically tidal and stream energy conversion. The generator is designed to work with both vertical and horizontal axis turbines. The final product is a high-pole-count, radial-flux, permanent magnet, rim mounted generator, initially rated at twenty kilowatts in a two-meter-per-second flow, and designed to leverage established and simple manufacturing processes. The generator was designed to work with a 3 meter by 7 meter Gorlov Helical Turbine or a marine hydrokinetic version of the FloDesign wind turbine. The team consisted of experienced motor/generator design engineers with cooperation from major US component suppliers (magnetics, coil winding and electrical steel laminations). Support for this effort was provided by Lucid Energy Technologies and FloDesign, Inc. The following tasks were completed: Identified the conditions and requirements for MHK generators. Defined a methodology for sizing and rating MHK systems. Selected an MHK generator topology and form factor. Completed electromechanical design of submersible generator capable of coupling to multiple turbine styles. Investigated MHK generator manufacturing requirements. Reviewed cost implications and financial viability. Completed final reporting and deliverables

13 HYDRO ENERGY↗

Fractional order PID controller for improvement of PMSM speed control in aerospace applications

Because of the benefits reduced size, cost and maintenance, noise, CO2 emissions and increased control flexibility and precision, to meet these expectations, electrical equipment increasingly utilize in modern aircraft systems and aerospace industry rather than conventional mechanic, hydraulic, and pneumatic power systems. Electric motor drives are capable of converting electrical power to drive actuators, pumps, compressors, and other subsystems at variable speeds. In the past decades, permanent magnet synchronous motor (PMSM) and brushless dc (BLDC) motor were investigated for aerospace applications such as aircraft actuators. In this paper, the fractional-order PID controller is used in the design of speed loop of PMSM speed control system. Having more parameters for tuning fractional order PID controller lead to good performance ratio to integer order. This good performance is shown by comparison fractional order PID controller with the conventional PI and tuned PID controller by Genetic algorithm in MATLAB soft wear.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simple Penning ion source for laboratory research and development applications

A simple Penning ion generator (PIG) that can be easily fabricated with simple machining skills and standard laboratory accessories is described. The PIG source uses an iron cathode body, samarium cobalt permanent magnet, stainless steel anode, and iron cathode faceplate to generate a plasma discharge that yields a continuous 1 mA beam of positively charged hydrogen ions at 1 mTorr of pressure. This operating condition requires 5.4 kV and 32.4 W of power. Operation with helium is similar to hydrogen. The ion source is being designed and investigated for use in a sealed-tube neutron generator; however, this ion source is thoroughly described so that it can be easily implemented by other researchers for other laboratory research and development applications.

43 PARTICLE ACCELERATORS↗

Study on proton fraction of beams extracted from electron cyclotron resonance ion source

A permanent magnet electron cyclotron resonance ion source PMECR II is used to generate proton ions for radio frequency quadrupole (RFQ) injection at Peking University (PKU). The proton fractions of the extracted beam were measured at the positions both after extraction system of ion source and the end of low energy beam transport line (LEBT). Experiments show that the proton fraction has a rise time within a beam pulse, and its value varies with pulse width and microwave power. The proton fractions measured at different positions are comparable.

43 PARTICLE ACCELERATORS↗