Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Reconstruction of Charged Particle Tracks in Realistic Detector Geometry Using a Vectorized and Parallelized Kalman Filter Algorithm

One of the most computationally challenging problems expected for the High-Luminosity Large Hadron Collider (HL-LHC) is finding and fitting particle tracks during event reconstruction. Algorithms used at the LHC today rely on Kalman filtering, which builds physical trajectories incrementally while incorporating material e ects and error estimation. Recognizing the need for faster computational throughput, we have adapted Kalman-filterbased methods for highly parallel, many-core SIMD and SIMT architectures that are now prevalent in high-performance hardware. Previously we observed significant parallel speedups, with physics performance comparable to CMS standard tracking, on Intel Xeon, Intel Xeon Phi, and (to a limited extent) NVIDIA GPUs. While early tests were based on artificial events occurring inside an idealized barrel detector, we showed subsequently that our mkFit software builds tracks successfully from complex simulated events (including detector pileup) occurring inside a geometrically accurate representation of the CMS-2017 tracker. Here, we report on advances in both the computational and physics performance of mkFit, as well as progress toward integration with CMS production software. Recently we have improved the overall eciency of the algorithm by preserving short track candidates at a relatively early stage rather than attempting to extend them over many layers. Moreover, mkFit formerly produced an excess of duplicate tracks; these are now explicitly removed in an additional processing step. We demonstrate that with these enhancements, mkFit becomes a suitable choice for the first iteration of CMS tracking, and eventually for later iterations as well. We plan to test this capability in the CMS High Level Trigger during Run 3 of the LHC, with an ultimate goal of using it in both the CMS HLT and oine reconstruction for the HL-LHC CMS tracker.

Cerati, Giuseppe↗

A zero dead-time multi-particle time and position sensitive detector based on correlation between brightness and amplitude

A new multi-particle time and position sensitive detector using only a set of microchannel plates, a waveform digitizer, a phosphor screen, and a CMOS camera is described. The assignment of the timing information, as taken from the microchannel plates by fast digitizing, to the positions, as recorded by the camera, is based on the COrrelation between the BRightness of the phosphor screen spots, defined as their integrated intensity and the Amplitude of the electrical signals (COBRA). Tests performed by observing the dissociation of HeH, the fragmentation of H{sub 3} into two or three fragments, and the photo-double-ionization of Xenon atoms are presented, which illustrate the performances of the COBRA detection scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high-resolution alpha spectrometry for nuclear forensics and safeguards applications

We will present our work on the development of ultra-high-resolution detectors for alpha particle spectrometry. These detectors, based on superconducting transition-edge sensors, offer energy resolution that is five to ten times better than conventional silicon detectors. Using these microcalorimeter detectors, the isotopic composition of mixed-actinide samples can be determined rapidly without the need for actinide separation chemistry to isolate each element, or mass spectrometry to separate isotopic signatures that can not be resolved using traditional alpha spectrometry (e.g. Pu-239/Pu-240, or Pu-238/Am-241). This paper will cover the detector and measurement system, actinide source preparation, and the quantitative isotopic analysis of a number of forensics- and safeguards-relevant radioactive sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Characterization of Low Gain Avalanche Detector Prototypes’ Response to Gamma Radiation

Motivated by the need for fast timing detectors to withstand up to 2 MGy of ionizing dose at the High Luminosity Large Hadron Collider, prototype low gain avalanche detectors (LGADs) have been fabricated in a single pad configuration, 2 × 2 arrays, and related p-i-n diodes, and exposed to Co-60 sources for study. Devices were fabricated with a range of dopant layer concentrations, and for the arrays, a variety of inter-pad distances and distances from the active area to the edge. Measurements of capacitance versus voltage and leakage current versus voltage have been made to compare pre- and post-irradiation characteristics in gain layer depletion voltage, full bulk depletion voltage, and breakdown voltage. Conclusions are drawn regarding the effects of the gammas on both surface and interface states and on their contribution to acceptor removal through non-ionizing energy loss from Compton electrons or photoelectrons. Comparison of the performances of members of the set of devices can be used to optimize gain layer parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

5 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_single

Single particle gun for detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 0.5, 5, 50, 500 , 5000 GeV (alternated). Uniform distribution in Phi. Uniform distribution in in the range [-4.5, 4.5].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

5 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_single_mu40

Single particle gun for detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 0.5, 5, 50, 500, 5000 GeV (alternated). Particles are generated using a uniform distribution in Phi and uniform distribution in Eta (pseudorapidity) in the range [-4.5,4.5]. Mixing with pileup: Each event is mixed with pileup using the tool described in arXiv:1510.06638. The pileup events use ATLAS A2 tune (all inelastic, including single and double diffractive events). The CM energy was 14 TeV. Events were generated with PYTHIA8. Events are mixed using a Poisson distribution with the mean mu=40 (average number of MinBias events). Then, only pileup particles around the single pion where taken in the cone 0.1 defined in eta and phi.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

5 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_single_mu140

Single particle gun for detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 0.5, 5, 50, 500, 5000 GeV (alternated). Particles are generated using a uniform distribution in Phi and uniform distribution in Eta (pseudorapidity) in the range [-4.5,4.5]. Mixing with pileup: Each event is mixed with pileup using the tool described in arXiv:1510.06638. MinBias events use the ATLAS A2 tune (all inelastic processes, including single and double diffractive events). The CM pp energy was 14 TeV. MinBias events were generated with PYTHIA8. Events are mixed using a Poisson distribution with the mean mu=140 (average number of MinBias events). Then, only pileup particles around the single pion where taken in the cone 0.1 defined in eta and phi.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

5 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_single_mu200

Single particle gun for detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 0.5, 5, 50, 500, 5000 GeV (alternated). Particles are generated using a uniform distribution in Phi and uniform distribution in Eta (pseudorapidity) in the range [-4.5,4.5]. Mixing with pileup: Each event is mixed with pileup using the tool described in arXiv:1510.06638. MinBias events use the ATLAS A2 tune (all inelastic processes, including single and double diffractive events). The CM pp energy was 14 TeV. MinBias events were generated with PYTHIA8. Events are mixed using a Poisson distribution with the mean mu=200 (average number of MinBias events). Then, only pileup particles around the single pion where taken in the cone 0.1 defined in eta and phi.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

10 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_1to10000gev

Single particle gun for detector studies: A particle gun with single pions. One pion per event. 5000 events per file, 50 files per sample. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pi is 1 , 10, 100, 1000, 10000 GeV. Uniform distribution in Phi. Uniform distribution in the Eta (pseudorapidity) range [-4.5, 4.5].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

5 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_mu_single

Single particle gun for detector studies: A particle gun with single muons. One muon per event. Production at (x,y,z,t)=(0,0,0,0). Charge is alternated. Momentum of muons is 0.4, 4, 40, 400 , 4000 GeV (alternated). Uniform distribution in Phi. Uniform distribution in in the range [-4.5, 4.5].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗