Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle stack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Synthesis, crystal structures and characterization of four coordination polymers based on 5-amino-2,4,6-triiodoisophthalic acid

One homochiral 1D coordination polymer [Cu(ATIBDC)(2,2'-bipy)].3H{sub 2}O.CH{sub 3}OH (1) and three achiral 1D coordination polymers: [Cd(ATIBDC)(2,2'-bipy)(H{sub 2}O)].3H{sub 2}O (2), [Cd(ATIBDC)(phen)(H{sub 2}O)].4H{sub 2}O (3), and [Mn(ATIBDC)(phen){sub 2}].5H{sub 2}O (4) have been synthesized and characterized (H{sub 2}ATIBDC=5-amino-2,4,6-triiodoisophthalic acid, 2,2'-bipy=2,2'-bipyridine, and phen=1,10-phenanthroline). Extended high dimensional network architectures are further constructed with the help of weak secondary interactions, such as hydrogen bonding, aromatic stacking, and halogen bonding (C-I..{pi} and C-I...N/O). Complex 1 crystallizes in the monoclinic system with chiral space group P2(1) and exhibits a right-handed 2{sub 1} helical chain structure. The homochirality of 1 was confirmed by CD spectrum. Interestingly, two new configurations of decameric water cluster are found in 3 and 4. The acyclic tetrameric cluster (H{sub 2}O){sub 3}(CH{sub 3}OH) in 1 and (H{sub 2}O){sub 4} in 2 array into highly ordered helical infinite chains. Thermal stabilities of all the complexes have been studied. Solid state fluorescent properties of the Cd(II) complexes have been explored. -- Graphical abstract: The synthesis, crystal structures and characterization of one 1D homochiral coordination polymer and three achiral 1D coordination polymers with 5-amino-2,4,6-triiodoisophthalic acid (H{sub 2}ATIBDC) are reported. Display Omitted highlights: > Four 1D coordination polymers with 5-amino-2,4,6-triiodoisophthalate are reported. > The halogen bonds play important roles in the supramolecular assembly. > Solid state fluorescent properties of the Cd(II) complexes are explored.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Quantum Efficiency Uni-Traveling-Carrier Photodiode for Optical to Microwave Transduction

Modern Quantum Information Systems (QIS) employ optical photons for long distance communication, operating at ambient temperature, between microwave cavities, which house microwave photons used in quantum computing and microwave detection. These optical photons, carried by fiber-optic or free-space links, offer a low-cost, uncooled alternative to bulky, expensive microwave coaxial cables, which are lossy, susceptible to EMI, and a significant thermal conductor to the outside ambient environment. To convert between these two types of photons and implement these optical interconnects, it is necessary to develop a high-performance photodetector for optical to microwave transduction. Freedom Photonics and the University of Virginia have a well-established partnership in developing high-performance photodiodes. In this Phase I effort, we collaborated in designing, fabricating, and testing an advanced, high-speed, high quantum efficiency prototype photodiode for transduction from optical to microwave frequencies. These devices have applications not only in quantum computing and axion detection, but also in other optical-cryogenic interconnect applications, in fields such as radio astronomy and quantum cryptography, as well as in quantum metrology and plasmonics. During this Phase I DOE program, we designed, fabricated, and tested prototype PIN GaAs photodiodes which targeted the performance parameters defined by the program. This process involved identifying a new target wavelength, different from that proposed initially, based on conversations with the Oak Ridge National Lab customer. We designed an epitaxial stack, optimized in theory for ≥95% quantum efficiency at 795 nm, ≥5 GHz, per the target objectives of the program. Additionally, we designed a fabrication process and associated mask plates for top-illuminated, AR-coated devices with device diameters ranging from 50 µm to 800 µm. Using these, we fabricated two 3” wafer quarters of devices, and characterized the devices’ dark current, quantum efficiency, and bandwidth for various device diameters. The prototype devices achieved a quantum efficiency of 89% at the target 795 nm detection wavelength. The bandwidth of the devices proved tricky to characterize, but a 50 µm diameter device shows a 3-dB bandwidth of at least 1.6 GHz, possibly a full 5 GHz, depending on the measurement setup. In the future, we plan to characterize the bandwidth of these devices using an impulse response measurement. All tasks for the Phase I were successfully completed, and sample prototype devices were provided to Oak Ridge National Lab Quantum Information Science researchers. The work performed in Phase I has established a strong foundation for future design and fabrication cycles in Phase II, if granted. The early tests at Oak Ridge National Labs will provide guidance for the required photodiode performance in devices to be supplied in Phase II.

42 ENGINEERING↗

Development of High Average Power Lasers for the Photon Collider

The laser and optics system for the photon collider seeks to minimize the required laser power by using an optical stacking cavity to recirculate the laser light. An enhancement of between 300 to 400 is desired. In order to achieve this the laser pulses which drive the cavity must precisely match the phase of the pulse circulating within the cavity. We report on simulations of the performance of a stacking cavity to various variations of the drive laser in order to specify the required tolerances of the laser system. We look at the behavior of a simple four mirror cavity as shown in Fig. 1. As a unit input pulse is applied to the coupling mirror a pulse begins to build up in the interior of the cavity. If the drive pulses and the interior pulse arrive at the coupling mirror in phase the interior pulse will build up to a larger value. The achievable enhancement is a strong function of the reflectivity of the cavities. The best performance if attained when the reflectivities of the input coupler is matched to the internal reflectivities of the cavity. In Fig. 2 we show the build up of the internal pulse after a certain number of drive pulses, assuming the input coupler has a reflectivity of 0.996 and the interior mirrors have 0.998 reflectivity. With these parameters the cavity will reach an enhancement factor of 450. Reducing the coupler reflectivity gives a faster cavity loading rate but with a reduced enhancement of the internal pulse. The enhancement as a function of coupler reflectivity and total internal cavity reflectivity is shown in Fig. 3. The best enhancement is achieved when the coupling mirror is matched to the reflectivity of the cavity. A coupler reflectivity just below the internal cavity reflectivity minimizes the required laser power.

42 ENGINEERING↗

Synthesis, structures, luminescent and magnetic properties of four coordination polymers with the flexible 1,3-phenylenediacetate ligands

Four coordination polymers, [Zn(pda)(bpy)(H{sub 2}O)]{sub n}.nH{sub 2}O (1), [Cd(pda)(prz)(H{sub 2}O)]{sub n} (2), [Co{sub 3}({mu}{sub 3}-OH){sub 2}(pda){sub 2}(pyz)]{sub n}.2nH{sub 2}O (3) and [Pr{sub 2}(pda){sub 3}(H{sub 2}O){sub 2}]{sub n} (4) (H{sub 2}pda=1,3-phenylendiacetic acid, bpy=4,4'-bipyridine, prz=piperazine and pyz=pyrazine) have been hydrothermally synthesized and characterized. Complex 1 is a 1D wheel-like chain structure, which is further extended into a 3D metal-organic supramolecular framework by H-bonds and {pi}-{pi} stacking interactions. Complex 2 is a 1D ladder-like chain structure, which is also further extended into a 3D metal-organic supramolecular framework by H-bonds. Complex 3 possess a 2D sheet structure with infrequent two pairs of double-helix chains. Complex 4 features a 3D structure. Both 1 and 2 display strong blue fluorescent emission at room temperature. Magnetic susceptibility measurements of complexes 3 and 4 exhibit antiferromagnetic interactions between the nearest metal ions, with C=9.99 and 3.43 cm{sup 3} mol{sup -1} K, and {theta}=-23.9 and -46.3 K, respectively. -- Graphical abstract: Four new coordination polymers with 1,3-phenylenediacetate ligands have been hydrothermally synthesized and characterized. Complexes 1 and 2 display strong blue fluorescent emission at room temperature. Magnetic susceptibility measurements of 3 and 4 exhibit antiferromagnetic interactions between the nearest metal centers. Display Omitted Research highlights: > Coordinative property of H{sub 2}pda ligand was shown when bonded by different block metals. > Careful selection of co-ligand and metals resulted in dramatic framework evolution. > (c) The compounds constructed with Zn{sup 2+} and Cd{sup 2+} exhibit strong blue fluorescent emission. > The magneto-structural correlation of the complexes constructed with Co{sup 2+} and Pr{sup 3+} was elucidated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First Experiments with the Polarized Internal Gas Target (PIT) at ANKE/COSY

For future few-nucleon interaction studies with polarized beams and targets at COSY-Juelich, a polarized internal storage-cell gas target was implemented at the magnet spectrometer ANKE. First commissioning of the polarized Atomic Beam Source (ABS) at ANKE was carried out and some improvements of the system have been done. Storage-cell tests to determine the COSY beam dimensions have been performed. Electron cooling combined with stacking and stochastic cooling have been studied. Experiments with N{sub 2} gas in the storage cell to simulate the background produced by beam interaction with the aluminum cell walls were performed to investigate the beam heating by the target gas. The analysis of the d-vectorp-vector->dp and d-vectorp-vector->(dp{sub sp})pi{sup 0} reactions showed that events from different positions of the extended target can be clearly identified in the ANKE detector system. The polarization of the atomic beam of the ABS, positioned close to the strong dipole magnet D2 of ANKE, was tuned with a Lamb-shift polarimeter (LSP) beneath the target chamber. With use of the known analyzing powers of the quasi-free np->dpi{sup 0} reaction, the polarization in the storage cell was measured to be Q{sub y} = 0.79+-0.07 in the vertical stray field of the D2 magnet acting as a holding field. The target thickness achieved was 2x10{sup 13} atoms/cm{sup 2} for one hyperfine state populated in the ABS beam only. With a COSY beam intensity of 6x10{sup 9} stored polarized deuterons in the ring, the luminosity for double polarized experiments was 1x10{sup 29} cm{sup -2} s{sup -1}.

43 PARTICLE ACCELERATORS↗

New members of ternary rare-earth metal boride carbides containing finite boron-carbon chains: RE{sub 25}B{sub 14}C{sub 26} (RE=Pr, Nd) and Nd{sub 25}B{sub 12}C{sub 28}

New ternary rare-earth metal boride carbides RE{sub 25}B{sub 14}C{sub 26} (RE=Pr, Nd) and Nd{sub 25}B{sub 12}C{sub 28} were synthesized by co-melting the elements. Nd{sub 25}B{sub 12}C{sub 28} is stable up to 1440 K. RE{sub 25}B{sub 14}C{sub 26} (RE=Pr, Nd) exist above 1270 K. The crystal structures were investigated by means of single-crystal X-ray diffraction. Nd{sub 25}B{sub 12}C{sub 28}: space group P1-bar, a=8.3209(7) A, b=8.3231(6) A, c=29.888(2) A, {alpha}=83.730(9){sup o}, {beta}=83.294(9){sup o}, {gamma}=89.764(9){sup o}. Pr{sub 25}B{sub 14}C{sub 26}: space group P2{sub 1}/c, a=8.4243(5) A, b=8.4095(6) A, c=30.828(1) A, {beta}=105.879(4){sup o}, V=2100.6(2) A{sup 3}, (R1=0.048 (wR2=0.088) from 2961 reflections with I{sub o}>2{sigma}(I{sub o})); for Nd{sub 25}B{sub 14}C{sub 26} space group P2{sub 1}/c, Z=2, a=8.3404(6) A, b=8.3096(6) A, c=30.599(2) A, {beta}=106.065(1){sup o}. Their structures consist of a three-dimensional framework of rare-earth metal atoms resulting from the stacking of slightly corrugated and distorted square nets, leading to cavities filled with cumulene-like molecules [B{sub 2}C{sub 4}]{sup 6-} and [B{sub 3}C{sub 3}]{sup 7-}, nearly linear [BC{sub 2}]{sup 5-} and bent [BC{sub 2}]{sup 7-} units and isolated carbon atoms. Structural and theoretical analysis suggests the ionic formulation for RE{sub 25}B{sub 14}C{sub 26}: (RE{sup 3+}){sub 25}[B{sub 2}C{sub 4}]{sup 6-}([B{sub 3}C{sub 3}]{sup 7-}){sub 2}([BC{sub 2}]{sup 5-}){sub 4}([BC{sub 2}]{sup 7-}){sub 2}(C{sup 4-}){sub 4}.5e{sup -} and for Nd{sub 25}B{sub 12}C{sub 28}: (Nd{sup 3+}){sub 25}([B{sub 2}C{sub 4}]{sup 6-}){sub 3}([BC{sub 2}]{sup 5-}){sub 4}([BC{sub 2}]{sup 7-}){sub 2}(C{sup 4-}){sub 4}.7e{sup -}. Accordingly, extended Hueckel tight-binding calculations indicate that the compounds are metallic in character. - Graphical Abstract: New ternary rare-earth metal boride carbides RE{sub 25}B{sub 14}C{sub 26} (RE=Pr, Nd) and Nd{sub 25}B{sub 12}C{sub 28} were synthesized by co-melting the elements. Nd{sub 25}B{sub 12}C{sub 28} is stable up to 1440 K. RE{sub 25}B{sub 14}C{sub 26} (RE=Pr, Nd) exist above 1270 K. The crystal structures were investigated by means of single-crystal X-ray diffraction. Their structures consist of a three-dimensional framework of rare-earth metal atoms resulting from the stacking of slightly corrugated and distorted square nets, leading to cavities filled with cumulene-like molecules [B{sub 2}C{sub 4}]{sup 6-} and [B{sub 3}C{sub 3}]{sup 7-}, nearly linear [BC{sub 2}]{sup 5-} and bent [BC{sub 2}]{sup 7-} units and isolated carbon atoms, respectively. Structural and theoretical analysis suggests the ionic formulation for RE{sub 25}B{sub 14}C{sub 26}: (RE{sup 3+}){sub 25}[B{sub 2}C{sub 4}]{sup 6-}([B{sub 3}C{sub 3}]{sup 7-}){sub 2}([BC{sub 2}]{sup 5-}){sub 4}([BC{sub 2}]{sup 7-}){sub 2}(C{sup 4-}){sub 4}.5e{sup -} and for Nd{sub 25}B{sub 12}C{sub 28}: (Nd{sup 3+}){sub 25}([B{sub 2}C{sub 4}]{sup 6-}){sub 3}([BC{sub 2}]{sup 5-}){sub 4}([BC{sub 2}]{sup 7-}){sub 2}(C{sup 4-}){sub 4}.7e{sup -}. Highlights: > New rare-earth metal boride carbides RE{sub 25}B{sub 14}C{sub 26} (RE=Pr, Nd) and Nd{sub 25}B{sub 12}C{sub 28}. > Structures contain 1-D finite B{sub 3}C{sub 3}, B{sub 2}C{sub 4}, BC{sub 2} units as well as isolated C atoms. > B/C distribution in the crystal structures was approved by EH-TB calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electromagnetic calorimeter for the Heavy Photon Search Experiment at Jefferson Lab

The Heavy Photon Search Experiment (HPS) seeks to detect a hypothesised hidden sector boson, the A', predicted to be produced in dark matter decay or annihilation. Theories suggest that the A' couples weakly to electric charge through kinetic mixing, allowing it, as a result, to decay to Standard Matter (SM) lepton pair, which may explain the electron and positron excess recently observed in cosmic rays. Measuring the lepton pair decay of the A' could lead to indirect detection of dark matter. The HPS experiment is a fixed target experiment that will utilize the electron beam produced at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The detector set-up includes a silicon vertex tracker (SVT) and an Electromagnetic Calorimeter (ECal). The ECal will provide the trigger and detect e+e- pairs and its construction and testing forms the focus of this thesis. The ECal consists of 442 PbWO 4 - tapered crystals with a length 16cm and a 1.6x1.6cm 2 cross-section, stacked into a rectangular array and are coupled to Large Area APDs and corresponding pre-amplifiers. Supplementary to the ECal is a Light Monitoring System (LMS) consisting of bi-coloured LEDs that will monitor changes in APD gain and crystal transparency due to radiation damage. Before construction of the ECal each of the components were required to be individually tested to determine a number of different characteristics. Irradiation tests were performed on PbWO 4 ECal crystals and, as a comparison, one grown by a different manufacturer to determine their radiation hardness. A technique for annealing the radiation damage by optical bleaching, which involves injecting light of various wavelengths into the crystal, was tested using the blue LED from the LMS as a potential candidate. The light yield dependence on temperature was also measured for one of the PbWO 4 crystal types. Each APD was individually tested to determine if they functioned correctly and within the requirements of the experiment, then arranged into groups of similar gain at chosen applied voltages, for connection to High Voltage (HV) supplies. Each bi-coloured LED was also tested to determine if they functioned within the specifications of the experiment; including their signal quality at high frequency and their radiation hardness. The HPS crystals were recycled from a previous Jefferson Lab detector, the Inner Calorimeter from CLAS, which needed to be dismantled and reconditioned using various removal and cleaning techniques. The HPS ECal was then constructed in a new formation using a combination of different gluing and construction techniques, and initial functionality tests were performed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Search for Dark Photon Dark Matter with a madmax Prototype

We report the first result from a dark photon dark matter search in the mass range from 78.62 to 83.95 μ eV / c 2 with a dielectric haloscope prototype for (Magnetized Disc and Mirror Axion eXperiment). Putative dark photons would convert to detectable photons within a stack consisting of three sapphire disks and a mirror. The emitted power of this system is received by an antenna and successively digitized using a low-noise receiver. No significant signal attributable to dark photons has been observed above the expected background. Assuming unpolarized dark photon dark matter with a local density of ρ χ = 0.3 G eV cm 3 we exclude a dark photon to photon mixing parameter χ > 2.7 × 10 − 12 over the full mass range and χ > 1.1 × 10 − 13 at a mass of 80.57 μ eV / c 2 with a 95% confidence level. This is the first physics result from a prototype and exceeds previous constraints on χ in this mass range by up to almost three orders of magnitude. Published by the American Physical Society 2025

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Composition of conglomerates analyzed by the Curiosity rover: Implications for Gale Crater crust and sediment sources

The Curiosity rover has analyzed various detrital sedimentary rocks at Gale Crater, among which fluvial and lacustrine rocks are predominant. Conglomerates correspond both to the coarsest sediments analyzed and the least modified by chemical alteration, enabling us to link their chemistry to that of source rocks on the Gale Crater rims. Here, we report the results of six conglomerate targets analyzed by Alpha-Particle X-ray Spectrometer and 40 analyzed by ChemCam. The bulk chemistry derived by both instruments suggests two distinct end-members for the conglomerate compositions. The first group (Darwin type) is typical of conglomerates analyzed before sol 540; it has a felsic alkali-rich composition, with a Na 2 O/K 2 O > 5. The second group (Kimberley type) is typical of conglomerates analyzed between sols 540 and 670 in the vicinity of the Kimberley waypoint; it has an alkali-rich potassic composition with Na 2 O/K 2 O < 2. The variety of chemistry and igneous textures (when identifiable) of individual clasts suggest that each conglomerate type is a mixture of multiple source rocks. Conglomerate compositions are in agreement with most of the felsic alkali-rich float rock compositions analyzed in the hummocky plains. The average composition of conglomerates can be taken as a proxy of the average igneous crust composition at Gale Crater. Finally, the differences between the composition of conglomerates and that of finer-grained detrital sediments analyzed by the rover suggest modifications by diagenetic processes (especially for Mg enrichments in fine-grained rocks), physical sorting, and mixing with finer-grained material of different composition.

58 GEOSCIENCES↗

WE-EF-303-04: An Advanced Image Processing Method to Improve the Spatial Resolution of Proton Radiographies

Purpose: We present an optimization method to improve the spatial resolution and the water equivalent thickness accuracy of proton radiographies. Methods: The method is designed for imaging systems measuring only the residual range of protons without relying on tracker detectors to determine the beam trajectory before and after the target. Specifically, the method was used for an imaging set-up consisting of a stack of 61 parallel-plate ionization chambers (PPIC) working as a range telescope. The method uses a decomposition approach of the residual range signal measured by the PPIC and constructs subimages with small size pixels geometrically rearranged and appropriately averaged to be merged into a final single radiography. The method was tested using Monte Carlo simulated and experimental proton radiographies of a PMMA step phantom and an anthropomorphic head phantom. Results: For the step phantom, the effective spatial resolution was found to be 4 and 3 times higher than the nominal resolution for the simulated and experimental radiographies, respectively. For the head phantom, a gamma index was calculated to quantify the conformity of the simulated proton radiographies with a digitally reconstructed X-ray radiography convolved with a Gaussian kernel equal to the proton beam spot-size. For DTA=2.5 mm and RD=2.5%, the passing ratio was 100%/85% for the optimized/non-optimized case, respectively. An extension of the method allows reducing the dose given to the patient during radiography acquisition. We show that despite a dose reduction of 25 times (leading to a dose of 0.016 mGy for the current imaging set-up), the image quality of the optimized radiographies remains fairly unaffected for both the simulated and experimental results. Conclusion: The optimization method leads to a significant increase of the spatial resolution allowing recovering image details that are unresolved in non-optimized radiographies. These results represent a major step towards clinical application of proton radiography.

60 APPLIED LIFE SCIENCES↗

TH-CD-201-07: Experimentally Investigating Proton Energy Deposition On the Microscopic Scale Using Fluorescence Nuclear Track Detectors

Purpose: In order to further understand the interplay between proton physics and radiobiology it is necessary to consider proton energy deposition on the microscopic scale. In this work we used Fluorescent Nuclear Track Detectors (FNTDs) to experimentally investigate proton energy deposition, track-by-track. Methods: We irradiated 8×4×0.5mm{sup 3} FNTD chips (Landauer Inc) at seven water depths along a pristine proton Bragg peak with range=12cm. After irradiation, the FNTDs were scanned using a confocal microscope (FV1200, Olympus) with a high-power red laser and an oil-immersion objective lens (UPLSAPO60XO, NA=1.35). 10 slice image stacks were acquired with a slice-thickness of 2µm at multiple positions across each FNTD. Image-based analyses of track radius and track “mass” (integrated signal intensity) were performed using trackpy. For comparison, Monte Carlo simulated data were obtained using TOPAS and TOPAS-nBio. Results: Excellent correlation was observed between median track mass and TOPAS dose-averaged linear energy transfer. The resolution of the imaging system was determined insufficient to detect a relationship between track radius and exposure depth. Histograms of track mass (i) displayed strong repeatability across positions within an FNTD and (ii) varied in peak position and shape as a function of depth. TOPAS-nBio simulations implemented on the nanometer scale using physics lists from GEANT4-DNA yielded energy deposition distributions for individual protons and electrons scored within a virtual FNTD. Good agreement was found between these simulated datasets and the FNTD track mass distributions. Conclusion: Robust experimental measurements of the integral energy deposited by individual proton tracks can be performed using FNTDs. Monte Carlo simulations offer an exceedingly powerful approach to the quantification of proton energy deposition on the microscopic scale, but whilst they have been well validated at the macroscopic level, their microscopic validation is far from complete. Our results demonstrate that FNTD-based study can play an important role in addressing this deficit. Tracy Underwood gratefully acknowledges the support of the European Commission under an FP7 Marie Curie International Outgoing Fellowship for Career Development (#630064).

60 APPLIED LIFE SCIENCES↗

Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade

The Short Strip ASIC (SSA) is one of the four front-end chips designed for the upgrade of the CMS Outer Tracker for the High Luminosity LHC. Together with the Macro-Pixel ASIC (MPA) it will instrument modules containing a strip and a macro-pixel sensor stacked on top of each other. The SSA provides both full readout of the strip hit information when triggered, and, together with the MPA, correlated clusters called stubs from the two sensors for use by the CMS Level-1 (L1) trigger system. Results from the first prototype module consisting of a sensor and two SSA chips are presented. The prototype module has been characterized at the Fermilab Test Beam Facility using a 120 GeV proton beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Weak lensing mass-richness relation of redMaPPer clusters in LSST DESC DC2 simulations

Cluster scaling relations are key ingredients in cluster abundance-based cosmological studies. In optical cluster cosmology, where clusters are detected through their richness, cluster-weak gravitational lensing has proven to be a powerful tool to constrain the cluster mass-richness relation. This work is conducted as part of the Dark Energy Science Collaboration (DESC), which aims to analyze the Legacy Survey of Space and Time (LSST) of the Vera C. Rubin Observatory, starting in 2026. Cluster properties inferred from weak lensing, such as mass, suffer from several sources of bias. In this paper, we aim to test the impact of modeling choices and observational systematics in cluster lensing on the inference of the mass-richness relation. We constrained the mass-richness relation of 3600 clusters detected by the redMaPPer algorithm in the cosmoDC2 extragalactic mock catalog of the LSST DESC DC2 simulation, covering 440 deg 2 , using number count measurements and either stacked weak lensing profiles or mean cluster masses in several intervals of richness (20 ≤ λ ≤ 200) and redshift (0.2 ≤ z ≤ 1). We provide the first constraints on the redMaPPer cluster mass-richness relation detected in cosmoDC2. We find that for an LSST-like source galaxy density, our constraints are robust to changes in the concentration-mass relation, as well as the dark matter density profile modeling choices, when source redshifts and shapes are perfectly known. We find that photometric redshift uncertainties can introduce bias at the 1σ level, which could be mitigated by an overall correction factor fitted jointly with the scaling parameters. We find that including positive shear-richness covariance in the fit shifts the results by up to 0.5σ. Our constraints also offer a fair comparison to a fiducial mass-richness relation, obtained from matching cosmoDC2 halo masses to redMaPPer-detected cluster richness results.

galaxy clusters↗

Measurement of cosmic-ray reconstruction efficiencies in the MicroBooNE LArTPC using a small external cosmic-ray counter

The MicroBooNE detector is a liquid argon time projection chamber at Fermilab designed to study short-baseline neutrino oscillations and neutrino-argon interaction cross-section. Due to its location near the surface, a good understanding of cosmic muons as a source of backgrounds is of fundamental importance for the experiment. We present a method of using an external 0.5 m (L) x 0.5 m (W) muon counter stack, installed above the main detector, to determine the cosmic-ray reconstruction efficiency in MicroBooNE. Data are acquired with this external muon counter stack placed in three different positions, corresponding to cosmic rays intersecting different parts of the detector. The data reconstruction efficiency of tracks in the detector is found to be $\epsilon_{\mathrm{data}}=(97.1\pm0.1~(\mathrm{stat}) \pm 1.4~(\mathrm{sys}))\%$, in good agreement with the Monte Carlo reconstruction efficiency $\epsilon_{\mathrm{MC}} = (97.4\pm0.1)\%$. This analysis represents a small-scale demonstration of the method that can be used with future data coming from a recently installed cosmic-ray tagger system, which will be able to tag $\approx80\%$ of the cosmic rays passing through the MicroBooNE detector.

47 OTHER INSTRUMENTATION↗

Atmospheric {sup 41}Ar Plume Tracking of the UF Training Reactor Using a Large-Volume NaI Detector

The ability to track and monitor gaseous radioactive materials is important in the event of a radioactive release such as from a nuclear power plant accident, weapons testing, or other unintended release scenarios. The International Monitoring System (IMS) is currently in place to monitor for weapons testing and has been used to monitor nuclear power plant accidents. However, only 80 radionuclide stations for the IMS exist in the world and are stationary, limiting the resolution of any radioactive plumes detected. Furthermore, the IMS radionuclide stations are designed to be sensitive specifically to atmospheric radio-xenon and no other radionuclides. Historically, monitoring radioactive releases has been limited to the detection of radio-xenon and radio-krypton, both arising as fission products from nuclear fuel. After the accident at Three Mile Island Unit 2, scientists were interested in finding the dose the public received from released radioactive material. This was achieved by analyzing radiation monitors in the exhaust stack and filters within the reactor building. furthermore, a series of 20 thermoluminescent dosimeters (TLD's), 8 air sampling station positioned around Three Mile Island, and a helicopter survey which used a NaI(Tl) detector array provided data on radionuclides, specifically {sup 137}Cs, that escaped the confines of the reactor building. The TLD's and air sampling stations were stationary, and therefore limited the resolution of the radioactive release plume. The helicopter survey using the NaI detectors was limited by the technology available at the time. The NaI detector array output was compressed from 1024 channels to 256 channels, limiting the energy resolution of the spectral data. The helicopter used a microwave ranging system to establish position. Since this survey was taken in October of 1982, advancements in technology allow spectral data to be saved in its full 1024 channel format and the advent of GPS can give a more accurate account of the detector position. An updated mobile system for tracking a radioactive release would help to alleviate these issues as well as gain the ability to track a radioactive release in real-time. We investigate the feasibility of mobile tracking through study and measurement of the {sup 41}Ar plume released from the University of Florida Training Reactor (UFTR) research reactor. We use a large-volume NaI(Tl) detector placed on the roof near the reactor. This detector may also be placed and moved on a cart to survey the area surrounding the reactor. We compare the spectral data taken when the reactor is running at full power to the background to analyze the effectiveness of the detector at identifying atmospheric {sup 41}Ar. Finally we discuss the implications of these measurements with regards to validation of plume models and the capability to track releases over a localized area from the source. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Specifications and pre-production of n + -in-p large-format strip sensors fabricated in 6-inch silicon wafers, ATLAS18, for the Inner Tracker of the ATLAS Detector for High-Luminosity Large Hadron Collider

Abstract The ATLAS experiment is constructing new all-silicon inner tracking system for HL-LHC. The strip detectors cover the radial extent of 40 to 100 cm. A new approach is adopted to use p-type silicon material, making the readout in n + -strips, so-called n + -in-p sensors. This allows for enhanced radiation tolerance against an order of magnitude higher particle fluence compared to the LHC. To cope with varying hit rates and occupancies as a function of radial distance, there are two barrel sensor types, the short strips (SS) for the inner 2 and the long strips (LS) for the outer 2 barrel cylinders, respectively. The barrel sensors exhibit a square, 9.8 × 9.8 cm 2 , geometry, the largest possible sensor area from a 6-inch wafer. The strips are laid out in parallel with a strip pitch of 75.5 μm and 4 or 2 rows of strip segments. The strips are AC-coupled and biased via polysilicon resistors. The endcap sensors employ a “stereo-annulus” geometry exhibiting a skewed-trapezoid shapes with circular edges. They are designed in 6 unique shapes, R0 to R5, corresponding to progressively increasing radial extents and which allows them to fit within the petal geometry and the 6-inch wafer maximally. The strips are in fan-out geometry with an in-built rotation angle, with a mean pitch of approximately 75 μm and 4 or 2 rows of strip segments. The eight sensor types are labeled as ATLAS18xx where xx stands for SS, LS, and R0 to R5. According to the mechanical and electrical specifications, CAD files for wafer processing were laid out, following the successful designs of prototype barrel and endcap sensors, together with a number of optimizations. A pre-production was carried out prior to the full production of the wafers. The quality of the sensors is reviewed and judged excellent through the test results carried out by vendor. These sensors are used for establishing acceptance procedures and to evaluate their performance in the ATLAS collaboration, and subsequently for pre-production of strip modules and stave and petal structures.

Instruments & Instrumentation↗

Channels occupancy and distortion in new lithium uranyl phosphates with three-dimensional open-frameworks

Three new lithium uranyl phosphates, Li{sub 2}(UO{sub 2}){sub 3}(PO{sub 4}){sub 2}O (1), Li(UO{sub 2}){sub 4}(PO{sub 4}){sub 3} (2) and Li{sub 3}(UO{sub 2}){sub 7}(PO{sub 4}){sub 5}O (3) were synthesized and studied. Powders of 1 and 2 were synthesized via solid state reaction, and single crystals of the three compounds were obtained by melting of 1 and 2 powders. The structures of the three compounds have been solved and refined from single crystal X-ray diffraction data. In the three compounds, the uranium atoms occupy square and pentagonal bipyramids. The uranium square bipyramids and phosphate tetrahedra are connected by vertices to form two types of layers with autunite sheet anion-topology {sub i}nfinity{sup 2}[(UO{sub 2})(PO{sub 4}){sub 2}]{sup 4-} and {sub i}nfinity{sup 2}[(UO{sub 2}){sub 2}(PO{sub 4}){sub 3}]{sup 5-}denoted S and D, respectively. The uranyl pentagonal bipyramids share opposite equatorial edges to form {sub i}nfinity{sup 1}[UO{sub 5}]{sup 4-} infinite chains. Mutually perpendicular chains are hung on each side of the sheets to build frameworks with non-crossing perpendicular channels that accommodate the lithium ions. Various stacking sequences of the S and D layers, S-S, D-D and S-D, generate three different frameworks in 1, 2 and 3, respectively. These compounds are similar to the recently reported vanadate analogous. However, the phosphate tetrahedra, smaller than the vanadate ones, gives distortion of the layers and a lowering of the symmetry and/or a change of periodicity. The electrical conductivity of 1 and 2 was measured using impedance spectroscopy method. The rather low conductivity of the lithium cations is explained by the crystal structure and the Li{sup +} position within the tunnels. These results corroborate those on the analogous three-dimensional alkaline uranyl vanadates. Crystallographic data: 293 K, BRUKER X8-APEX2 X-ray diffractometer, 4 K CCD detector, MoKalpha, lambda=0.71073 A, full-matrix least-squares refinement on the basis of F. 1, Tetragonal symmetry, space group I4{sub 1}/amd, Z=4 with a=7.1109(2) A and c=25.0407(8) A, R=0.034 and wR=0.047 for 38 parameters with 479 independent reflections with I>=3sigma(I). 2, monoclinic symmetry, space group P2{sub 1}/c, Z=4 and a=9.8829(2) A, b=9.8909(2) A, c=17.4871(4) A and beta=106.198(1){sup o}, R=0.021 and wR=0.031 for 249 parameters with 4201 independent reflections with I>=3sigma(I). 3, Tetragonal symmetry, space group P4-bar2{sub 1}m with a=9.9305(2) A and c=14.5741(3) A, R=0.035 and wR=0.038 for 137 parameters with 4527 independent reflections with i>=3sigma(I). - Graphical abstract: The three new lithium uranyl phosphates Li{sub 2}(UO{sub 2}){sub 3}(PO{sub 4}){sub 2}O, Li(UO{sub 2}){sub 4}(PO{sub 4}){sub 3} and Li{sub 3}(UO{sub 2}){sub 7}(PO{sub 4}){sub 5}O were synthesised via solid state reaction. The structures of these compounds are based upon three-dimensional open-frameworks built from {sub i}nfinity{sup 1}[UO{sub 5}]{sup 4-} chains connected through two types of layers, S and D, in the sequences S-S, D-D and S-D, respectively. The lithium atoms distribution along the channels induces various distortions of the {sub i}nfinity{sup 1}[UO{sub 5}]{sup 4-} chains.

36 MATERIALS SCIENCE↗

Beam test performance studies of CMS Phase-2 Outer Tracker module prototypes

A new tracking detector will be installed as part of thePhase-2 upgrade of the CMS detector for the high-luminosity LHC era.This tracking detector includes the Inner Tracker, equipped withsilicon pixel sensor modules, and the Outer Tracker, consisting ofmodules with two parallel stacked silicon sensors. The Outer Trackerfront-end ASICs will be able to correlate hits from chargedparticles in these two sensors to perform on-module discriminationof transverse momenta (p$_{T}$). The p$_{T}$information is generated at a frequency of 40 MHz and will be usedin the Level-1 trigger decision of CMS. Prototypes of theso-called 2S modules were tested at the Test Beam Facility at DESYHamburg between 2019 and 2020. These modules use the finalfront-end ASIC, the CMS Binary Chip (CBC), and for the firsttime the Concentrator Integrated Circuit (CIC), optical readoutand on-module power conversion. In total, seven modules were tested,one of which was assembled with sensors irradiated with protons. Animportant aspect was to show that it is possible to read out modulessynchronously. A cluster hit efficiency of about 99.75 % wasachieved for all modules. The CBC p$_{T}$ discriminationmechanism has been verified to work together with the CIC andoptical readout. The measured module performance meets therequirements for operation in the upgraded CMS tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗