Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Assessment of Nuclear Structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

803 records · Page 45

In-service Inspection of Radioactive Waste Tanks at the Savannah River Site – 15410

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is approximately 1.70 millimeter deep (i.e., less than 10% through-wall). Improvements to the inspection program were recently instituted to provide additional confidence in the degradation rates. Thickness measurements from a single vertical strip along the accessible height of the primary tank have been used as a baseline to compare historical measurements. Changes in wall thickness and pit depths along this vertical strip are utilized to estimate the rate of corrosion degradation. An independent review of the ISI program methodology, results, and path forward was held in August 2009. The review recommended statistical sampling of the tanks to improve the confidence of the single strip inspection program. The statistical sampling plan required that SRS increase the amount of area scanned per tank. Therefore, in addition to the baseline vertical strip that is obtained for historical comparisons, four additional randomly selected vertical strips are inspected. To date, a total of 104 independent vertical strips along the height of the primary tank have been completed. A statistical analysis of the data indicates that at this coverage level there is a 99.5% confidence level that one of the worst 5% of all the vertical strips was inspected. That is, there is a relatively high likelihood that the SRS inspection program has covered one of the most corroded areas of any of the Type III/IIIA waste tanks. These data further support the conclusion that there are no significant indications of wall thinning or pitting. Random sampling will continue to increase the confidence that one of the worst 5% has been inspected. In order to obtain the additional vertical strips, and minimize budget and schedule impacts, data collection speed for the UT system was optimized. Prior to 2009, the system collected data at a rate of 32 square centimeters per minute. The scan rate was increased to 129 - 160 square centimeters per minute by increasing the scanner step and pixel sizes in the data acquisition set-up. Laboratory testing was utilized to optimize the scan index/pixel size such that the requirements for wall thinning and pit detection were still maintained. SRS continues to evaluate improvements to ultrasonic equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Conditioned System-Level Groundwater Model to Evaluate Long-Term Groundwater Impacts within a Performance Assessment - 20115

A preliminary performance assessment (PA) of single-shell tank Waste Management Area (WMA) A-AX located at the U.S. Department of Energy (DOE)'s Hanford Site in southeastern Washington is being conducted to satisfy the requirements of DOE Order 435.1 [1] as it relates to closure of the single-shell radioactive waste tanks in the WMA A-AX tank farms. A PA assesses the fate, transport, and impacts of radionuclides within a low-level radioactive waste disposal facility in its assumed closure configuration and the subsequent potential doses to humans over a 1,000-year compliance period and a 10,000-year performance evaluation period. The WMA A-AX preliminary PA evaluation is structured around the complementary use of process-level and system-level models to calculate the facility performance against established DOE Order 435.1 [1] performance objectives. Process-level models are those that represent a detailed phenomenological representation of processes of concern in the PA. Process models typically only represent one or a few of the components of the PA, such as groundwater flow and transport, and must be integrated with other modeling elements to perform PA calculations. System-level models are those that are abstracted from the process models, retaining the essential features of the process model, while allowing integration of all aspects of the PA in a single modeling framework. System-level models are often characterized by coarser numerical discretization, lower dimensionality, or other similar simplifications compared to the process-level model. Traditionally, a three-dimensional (3-D) process-level model is utilized primarily to evaluate the long-term impact on groundwater and the potential doses to individuals who consume contaminated groundwater. System-level models are also utilized to evaluate the groundwater pathway in PAs. These models typically have reduced dimensionality (1-D) and are conditioned utilizing flow fields (Darcy fluxes) and moisture content distributions that are abstracted from the process level models. The abstraction approach assures that the flow field in both models is consistent for a specific set of input parameters for flow, differing only in the discretization and dimensionality of the two models. The preliminary WMA A-AX PA incorporates a detailed representation of the geological system and hydraulic properties within the 3-D model STOMP{sup C} numerical code so that the effects of relevant features and processes on water flow and radionuclide transport in the subsurface can be evaluated. The complementary system-level model is developed utilizing the GoldSim{sup C} code to implement a simplified, 1-D equivalent model to represent the groundwater pathway. Contaminant transport through the vadose zone and unconfined aquifer for Tc-99 and I-129 were evaluated in each of the models. Adjustments to the saturated portion of the GoldSim{sup C} 1-D model were required to mimic the dispersion effect captured with the 3-D STOMP{sup C} model. Once this conditioning was conducted, highly similar results for the transport of Tc-99 and I-129 were achieved at the point of calculation, located 100 m downgradient from the WMA A-AX fenceline. These radionuclides represent elements that are regarded as primary dose drivers in the PA groundwater pathway analysis. The high degree of conformance between the two models suggests that the use of the equivalent 1-D system model is suitable for evaluating the full suite of radionuclides that will be released from the tank sources within WMA A-AX over the 1,000-year compliance period and over the 10,000-year evaluation period. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-service inspection of radioactive waste tanks at the Savannah River Site - 15410

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks, will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is approximately 1.70 millimeter deep (i.e., less than 10% through-wall). Improvements to the inspection program were recently instituted to provide additional confidence in the degradation rates. Thickness measurements from a single vertical strip along the accessible height of the primary tank have been used as a baseline to compare historical measurements. Changes in wall thickness and pit depths along this vertical strip are utilized to estimate the rate of corrosion degradation. An independent review of the ISI program methodology, results, and path forward was held in August 2009. The review recommended statistical sampling of the tanks to improve the confidence of the single strip inspection program. The statistical sampling plan required that SRS increase the amount of area scanned per tank. Therefore, in addition to the baseline vertical strip that is obtained for historical comparisons, four additional randomly selected vertical strips are inspected. To date, a total of 104 independent vertical strips along the height of the primary tank have been completed. A statistical analysis of the data indicates that at this coverage level there is a 99.5% confidence level that one of the worst 5% of all the vertical strips was inspected. That is, there is a relatively high likelihood that the SRS inspection program has covered one of the most corroded areas of any of the Type III/IIIA waste tanks. These data further support the conclusion that there are no significant indications of wall thinning or pitting. Random sampling will continue to increase the confidence that one of the worst 5% has been inspected. In order to obtain the additional vertical strips, and minimize budget and schedule impacts, data collection speed for the UT system was optimized. Prior to 2009, the system collected data at a rate of 32 square centimeters per minute. The scan rate was increased to 129 - 160 square centimeters per minute by increasing the scanner step and pixel sizes in the data acquisition set-up. Laboratory testing was utilized to optimize the scan index/pixel size such that the requirements for wall thinning and pit detection were still maintained. SRS continues to evaluate improvements to ultrasonic equipment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

R and DE Robotic Sensor Intern Team: Sensor Suite Mock Up Testing

Assess sensor suite performance: - Mounted on crawler typical to what would be used in tunnel; - In test bed simulating the tunnel environment. The SuperDroid fiber tethered LT-F crawler is a general-purpose surveillance robot that our team has refurbished as a testing platform for the sensor suite. This crawler was selected because its dimensions are similar to the actual crawler that will be deployed in the field. Crawler preparation included: - Communicating with vendor to resolve software and platform issues; - Configuring a laptop with the crawler control software; - Reconfiguration of communication protocol between computer and crawler; - Resolution of control board checksum errors; - Installation of a mounting fixture on the base; - In progress: addition of lighting needed for total darkness. A solution for hosting the selected sensors onto a single unit that could function standalone or be mounted on the crawler was needed. Sensor mount requirements included: - Host Lidar, panospheric cameras and IMU sensors; - Cable management for rotating Lidar; - House on-board crawler computer; - Method for affixing to crawler; - Robust and vibration proof. The Lidar sensor required a sturdy mount that ensured the axis of rotation be centered with the LiDAR's desired laser path and included a slender profile in order to not block the scanning FOV. The mounting plate holds two 180-degree cameras on either side and the servo on the center. The servo mount is located so the axis of rotation is in the center of the plate. The mount features a set of guides that hold the wires and ensure they wrap around the spool area properly. The sensor box design features thick walls for added strength, holes for mounting the sensor suite to the crawler, notches on the bottom for the different components and holes for cable routing and management. The sensor mounts were designed using CREO and printed in the R and DE Additive Manufacturing Lab. To test the performance of the sensor suite for our application it was desired to design and build a test bed simulating the H-Canyon tunnel environment. Requirements included: - Dimensions similar to the tunnel; - Wall surfaces simulating the eroded tunnel walls; - Complete darkness; - Even and uneven crawler path; - Ability to change the tunnel width to simulate erosion. The HCAEX tunnel changes in height and includes several bends ranging from approximately 30 to 80 degrees, for that reason a test bed capable of easily being changed was needed. The final design includes two sections that can be connected to provide a 16' tunnel or placed at an angle to create a tunnel bend. The test bed features caster wheels for easy movement and has a sliding inner wall that enables tunnel width to be controlled. In order to simulate the tunnel walls without adding a lot of weight to the test bed, sheets of faux stone are to be used on the inner walls. To create a completely dark tunnel, 100% black-out film will be draped over the tunnel structure. Carpet remnants in the lab will enable folds to be introduced in the floor to generate uneven surface data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of Multi-Step CADIS Parameter Sensitivity to Neutron Flux Spectrum in Shutdown Dose Rate Calculations

Shutdown dose rate (SDDR) analysis requires (a) a neutron transport calculation to estimate neutron flux fields, (b) an activation calculation to compute radionuclide inventories and associated photon sources, and (c) a photon transport calculation to estimate final dose rate. In some applications, accurate full-scale Monte Carlo (MC) SDDR simulations are needed for very large systems with massive amounts of shielding materials. For example, SDDR assessments are required throughout the biological shield (bio-shield) of the ITER experimental facility to evaluate the required waiting period after the shutdown of ITER and to identify the locations where human accessibility should be prohibited. The bio-shield is a large cylindrical concrete structure (30 m tall and 34 m in diameter) surrounding the very complex tokamak machine. Determining the effects on SDDR of important factors, such as the cross talk (interactions) between the different ports of ITER, is possible only through full-scale simulations that involve all the complex inner details of the ITER tokamak machine. These simulations are impractical because calculation of space- and energy-dependent neutron fluxes throughout the structural materials is needed to estimate the distribution of radioisotopes causing the SDDR. Determining a good importance function that can be used in biasing a neutron MC calculation for SDDR is complicated because it is difficult to explicitly express the SDDR response function, which depends on subsequent computational steps. The Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) hybrid MC/deterministic method was developed to speed up the SDDR MC neutron transport calculation using an importance function that represents the neutron importance to the final SDDR. The MS-CADIS method uses the CADIS method, which has been Notice: This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC0500OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for the United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan). successfully used for more than a decade in radiation shielding applications to generate consistent source biasing and weight window (WW) variance reduction parameters to accelerate continuous-energy MC simulations. However, because MS-CADIS focuses on multi-step shielding calculations such as SDDR calculations, it develops an importance function for the initial radiation transport calculation (e.g., the neutron calculations in SDDR simulations) that represents the importance of particles to the final response of the overall simulation. To develop this importance function, the MS-CADIS method uses an adjoint calculation with a specific neutron adjoint source that represents the neutron's contribution to the final SDDR. Brute force calculation of the MS-CADIS neutron adjoint source requires a deterministic neutron transport calculation coupled with activation calculations in each element of the deterministic mesh. These calculations are needed to determine the MS-CADIS parameter for the neutron interactions that produce radioisotopes contributing to the SDDR. The MS-CADIS parameter is the microscopic cross section of the radioisotope-producing interaction, multiplied by the mass of this radioisotope existing at the end of the irradiation and decay scenario, and divided by the steady-state rate of the interaction. Because the activation calculations are performed for each radionuclide in each mesh element, implementation of the MS-CADIS method can be computationally expensive. However, these neutron transport and activation calculations are not needed if we assume that the radioisotopes are created due to single neutron interactions and their concentrations do not change as a result of burnup by neutron irradiation. The use of this approximation, which renders the MS-CADIS parameter independent of the neutron flux, seems reasonable in calculating the MS-CADIS importance function because this function is needed only to speed up the MC calculation, not to calculate the final SDDR. In this work, we investigate the validity of this approximation by investigating the behavior of the MS-CADIS parameter as a function of the neutron flux spectra in the Fusion Evaluated Nuclear Data Library (FENDL) Neutronics and Shielding Benchmark problem that contains representative isotopes and flux environments of fusion energy systems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photometric redshift analysis in the Dark Energy Survey Science Verification data

In this study, we present results from a study of the photometric redshift performance of the Dark Energy Survey (DES), using the early data from a Science Verification period of observations in late 2012 and early 2013 that provided science-quality images for almost 200 sq. deg. at the nominal depth of the survey. We assess the photometric redshift (photo-z) performance using about 15 000 galaxies with spectroscopic redshifts available from other surveys. These galaxies are used, in different configurations, as a calibration sample, and photo-z's are obtained and studied using most of the existing photo-z codes. A weighting method in a multidimensional colour–magnitude space is applied to the spectroscopic sample in order to evaluate the photo-z performance with sets that mimic the full DES photometric sample, which is on average significantly deeper than the calibration sample due to the limited depth of spectroscopic surveys. In addition, empirical photo-z methods using, for instance, artificial neural networks or random forests, yield the best performance in the tests, achieving core photo-z resolutions σ68 ~ 0.08. Moreover, the results from most of the codes, including template-fitting methods, comfortably meet the DES requirements on photo-z performance, therefore, providing an excellent precedent for future DES data sets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Creep-­Fatigue Models on Advanced Materials for SFR Applications (Final Report)

This report provides an update on the materials performance criteria and methodology relevant to sodium-cooled fast reactors (SFRs). The report is the second deliverable (Level 2) in FY11 (M2A11AN040303) under the work package A-11AN040303 “Materials Performance Criteria and Methodology” as part of the Advanced Structural Materials Program for the Advanced Reactor Concepts. The overall objective of the Materials Performance Criteria and Methodology work project is to evaluate the key requirements for the ASME Code qualification and the Nuclear Regulatory Commission (NRC) approval of advanced structural materials in support of the design and performance of sodium-cooled fast reactors. Advanced materials are a critical element in the development of fast reactor technologies. Enhanced materials performance not only improves safety margins and provides design flexibility, but also is essential for the economics of future advanced fast reactors. Qualification and licensing of advanced materials are prominent needs for the development and implementation of advanced fast reactor technologies. Nuclear structural component designs in the U.S. comply with the ASME Boiler and Pressure Vessel (B&PV) Code Section III (Rules for Construction of Nuclear Facility Components), and the NRC grants licensing. As the SFRs will operate at higher temperatures than the current light water reactors (LWRs), the design of elevated-temperature components must comply with ASME Section III Subsection NH (Class 1 Components in Elevated Temperature Service). A number of technical issues relevant to materials performance criteria and high temperature design methodology in the SFR were identified and presented in earlier reports. A viable approach to resolve these issues and the R&D priority were also recommended. The development of mechanistically based creep-fatigue interaction models for life prediction and reliable data extrapolation was chosen to be the central focus in near-term efforts. Our current focus is on the creep-fatigue damage issue in high-strength ferritic/martensitic steels such as mod.9Cr-1Mo (G91) and NF616 (G92) steels. The current ASME creep-fatigue design rule puts severe limits of fatigue and creep loads for G91 steel, the lead structural material for fast reactors. High-strength ferritic/martensitic steels behave fundamentally differently from austenitic stainless steels, for which the current ASME creep-fatigue design rules were developed. The unique deformation and damage characteristics in G91 steel, e.g. cyclic softening, degradation of creep and rupture strength during cyclic service, demands a new creep-fatigue design procedure that explicitly accounts for the material’s unique creep-fatigue behavior. G92 steel, a variant of G91 steel, is the lead candidate in the Advanced Alloy Development program. There is currently no creep-fatigue design rule available for this advanced alloy. To support the predictive model development and resolve the over-conservative issue with the ASME design rule for G91 steel, we recovered stress relaxation data from thirteen creep-fatigue tests conducted in the late 1980s and early 1990s at Oak Ridge National Laboratory, and conducted extensive data analysis in FY10. Based on this database and available literature data, we have developed a Cyclic Softening Model and a Stress Relaxation Model specifically applied to G91 steel. The Cyclic Softening Model describes the cyclic stress variation as a function of cycle number during creep-fatigue loading, and well captures the cyclic softening effect in G91 steel. The Stress Relaxation Model predicts the stress relaxation curve during the hold time of cyclic loading, and its dependence on the cyclic softening effect of G91 steel. Two creep-fatigue test systems have been set up to conduct model-oriented creep-fatigue experiments. Results from three creep-fatigue experiments on Heat 30176 of G91 steel are presented in the report: (1) a test performed at 550°C with total strain amplitude of 0.25% and a hold time of 60 s applied at peak strains in both tension and compression, (2) a test performed at 400°C with total strain amplitude of 0.5% and a tension and compression hold time of 60 s, and (3) a test performed at 20°C with total strain amplitude of 0.5% and a tension and compression hold time of 60 s. Three different test temperatures were chosen for two primary reasons: to determine the transition temperature of creep-fatigue interaction from a plasticity-dominated process to a creep-dominated process; to develop unified creep-fatigue models applicable for a wide range of temperatures. With the detailed information obtained in the creep-fatigue experiments, we have further refined the Cyclic Softening Model and Stress Relaxation Model. The Cyclic Softening Model and Stress Relaxation Model were incorporated into the Bilinear Creep-Fatigue Damage Model, forming a powerful framework for the life prediction by an improved creep-fatigue evaluation methodology. The cyclic softening and consecutive stress relaxation responses in G91 steel can be considered for each cycle of the entire cyclic process in the model calculation. The creep-fatigue damage in G91 steel was evaluated using the improved Bilinear Creep-Fatigue Damage Model without any safety margins. It was found that due to the significant cyclic softening in G91 steel, the unit creep damage in each cycle decreased continuously with increasing number of cycles. This continuous change in creep damage with cycling has significant implication in the evaluation of the total creep-fatigue damage. The total creep damage can be one order of magnitude lower when the unit creep damage at half-life was used in the evaluation in comparison with the calculations using the unit creep damage at cycle 10. An important conclusion was that the accurate assessment of the creep-fatigue damage in G91 steel must consider the history of cycling. This analysis provides a more realistic assessment of creep-fatigue damage and identifies critical factors that must be considered in the development of future advanced models for high-strength ferritic/martensitic alloys. An accelerated creep-fatigue testing methodology is proposed for the design of model-oriented experiments to guide and validate model developments. Future work will focus on creep-fatigue experiments of both G91 and G92 steels, and development of creep-fatigue models applicable to advanced ferritic/martensitic alloys. The Cyclic Softening Model and Stress Relaxation Model will be improved by incorporating microstructural parameters of dislocation density, subgrain structure, and second-phase particles. Collaborative modeling of combined Cyclic Softening Model, Stress Relaxation Model, and Interactive Damage Rate Model will be pursued for life prediction under creep-fatigue loading with extended hold time. Accelerated, well-controlled creep-fatigue tests will be conducted to provide high-quality experimental data to refine key material parameters and validate models.

Li, Meimei↗

Sensor Network Demonstration for In Situ Decommissioning - 13332

Florida International University's (FIU's) Applied Research Center is currently supporting the Department of Energy's (DOE) Environmental Management Office of D and D and Facility Engineering program. FIU is supporting DOE's initiative to improve safety, reduce technical risks, and limit uncertainty within D and D operations by identifying technologies suitable to meet specific facility D and D requirements, assessing the readiness of those technologies for field deployment, and conducting feasibility studies and large scale demonstrations of promising technologies. During FY11, FIU collaborated with Savannah River National Laboratory in the development of an experimental test site for the demonstration of multiple sensor systems for potential use in the in situ decommissioning process. In situ decommissioning is a process in which the above ground portion of a facility is dismantled and removed, and the underground portion is filled with a cementious material such as grout. In such a scenario, the question remains on how to effectively monitor the structural health of the grout (cracking, flexing, and sinking), as well as track possible migration of contaminants within and out of the grouted monolith. The right types of sensors can aid personnel in better understanding the conditions within the entombed structure. Without sensors embedded in and around the monolith, it will be very difficult to estimate structural integrity and contaminant transport. Yet, to fully utilize the appropriate sensors and the provided data, their performance and reliability must be evaluated outside a laboratory setting. To this end, a large scale experimental setup and demonstration was conducted at FIU. In order to evaluate a large suite of sensor systems, FIU personnel designed and purchased a pre-cast concrete open-top cube, which served as a mock-up of an in situ DOE decommissioned facility. The inside of the cube measures 10 ft x 10 ft x 8 ft. In order to ensure that the individual sensors would be immobilized during the grout pouring activities, a set of nine sensor racks were designed. The 270 sensors provided by Idaho National Laboratory (INL), Mississippi State University (MSU), University of Houston (UH), and University of South Carolina (USC) were secured to these racks based on predetermined locations. Once sensor racks were installed inside the test cube, connected and debugged, approximately 32 cubic yards of special grout material was used to entomb the sensors. MSU provided and demonstrated four types of fiber loop ring-down (FLR) sensors for detection of water, temperature, cracks, and movement of fluids. INL provided and demonstrated time differenced 3D electrical resistivity tomography (ERT), advanced tensiometers for moisture content, and thermocouples for temperature measurements. University of Houston provided smart aggregate (SA) sensors, which detect crack severity and water presence. An additional UH sensor system demonstrated was a Fiber Bragg Grating (FBG) fiber optic system measuring strain, presence of water, and temperature. USC provided a system which measured acoustic emissions during cracking, as well as temperature and pH sensors. All systems were connected to a Sensor Remote Access System (SRAS) data networking and collection system designed, developed and provided by FIU. The purpose of SRAS was to collect and allow download of the raw sensor data from all the sensor system, as well as allow upload of the processed data and any analysis reports and graphs. All this information was made available to the research teams via the Deactivation and Decommissioning Knowledge Management and Information Tool (D and D KM-IT). As a current research effort, FIU is performing an energy analysis, and transferring several sensor systems to a Photovoltaic (PV) System to continuously monitor energy consumption parameters and overall power demands. Also, One final component of this research is focusing on developing an integrated data network to capture, log and analyze sensor system data in near real time from a single interface. FIU personnel and DOE Fellows monitored the progress and condition of the sensors for a period of six months. During this time, the sensors recorded data pertaining to strain, compression, temperature, crack detection, moisture presence, fluid mobility, shock resistance, monolith movement, and electrical resistivity. In addition, FIU regularly observed the curing process of the grout and documented the cube condition via the nine racks of sensors. The sensors held up throughout the curing process, withstood the natural elements for six months, and monitored the integrity of the grout. The large scale experiment and demonstration conducted at FIU was the first of its kind to demonstrate the feasibility of state of the art sensors for in situ decommissioning applications. These efforts successfully measured the durability, performance, and precision of the sensors in question as well as monitored and recorded the curing process of the selected grout material under natural environmental conditions. The current energy analysis work is resulting in data on the constraints placed by some of the sensor systems on a power network that requires high reliability and low losses. In addition, a sensor system demonstration has determined that it is feasible to develop an integrated data network where data can be accessed in near real-time from all systems, thereby allowing for larger-scale integrated system testing to be performed. Information collected during the execution of this research project will aid decision makers in the identification of sensors to be used in nuclear facilities selected for in situ decommissioning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Probability of Pinching Failure in PWR SNF after Long-Term Storage

A probabilistic assessment was performed on pinching failure of PWR SNF rod cladding under accidental SNF cask transport conditions. a set of 3,000 rod pinching scenarios was analyzed, with different geometrical, material, and loading parameters, using a Latin Hypercube Sampling (LHS). The investigated accidents include train derailments leading to cask collisions or cask drops. Pinching failure was related to cladding offset strain, defined as the plastic deformation interval in radial cladding direction normalized with respect to the outer cladding diameter. Finite element (FE) models were used to compute SNF rod deformations and the offset strain demand OSD in each of the assessed pinching scenarios. The numerical models account for the contribution of the degraded fuel pellets to rod pinching stiffness. The offset strain capacity OSC was computed using regression and interpolation models based on ring compression (RCT) test results, and account for hydride-related effects on cladding ductility. The results show a low probability of pinching failure. Hydride-related cladding embrittlement affects the structural integrity of PWR SNF rods after long-term dry storage of up to 300 years. Radial hydride patterns or large amounts of circumferentially oriented hydrides reduce the cladding ductile deformation capability when pinched at low material temperatures. The probability of hydride-related pinching failure of PWR cladding is estimated after long-term dry storage to address: How do PWR SNF rod conditions like hydrogen content, vacuum drying peak cladding hoop stress σ{sub θ}, and cladding material temperature affect cladding ductility? Is hydride-related cladding embrittlement a material degradation mechanism that affects the structural integrity of PWR SNF rods under pinching loading? What are the controlling parameters for deformation demands in PWR SNF rods under pinching loading? Is the pinching load amplitude an important parameter that controls the probability of pinching failure? How do parameters like pellet-cladding gap or fuel pellet degradation affect the pinching loading capacity of PWR SNF rods? Statistical modelling of PWR SNF rod conditions in U.S. inventory: A pseudo rod database was generated based on EIA database. Analysis of train accident scenarios: a probability density function (pdf) of a pinching load distribution P{sub 9m} of a 9-m cask drop is linearly scaled to generate a more representative: distribution P{sub AS}. The new distribution considers train collision velocities, cask drops for on- and off-bridge accidents, and cask impact orientation. LHS generates 3,000 rod pinching scenarios based on nine independent geometrical, material, and loading parameters. Probabilistic FE Analysis: The LHS realizations are used to generate 3,000 FE models. The FE analysis is conducted for P{sub 9m}, and P{sub AS}. The workflow is automatized. The OSC is computed with regression and interpolation models, as a function of the hydrogen content C{sub H}, vacuum drying peak σ{sub θ}, and SNF temperature T{sub FR}: The regression data was obtained in RCTs on PWR cladding. The OSD is derived from the cladding deformations in the FE models. Cladding failure was identified via a comparison of OSC and OSD. A 300 and a 30 years-of-dry-storage duration is investigated: The dry-storage period affects the expected SNF temperature and consequently, the OSC and the OSD. The material temperature LHS population is adapted to account for a SNF temperature variation. The probability of hydride-related, ductile cladding failure during a severe transportation accident is not significantly affected by the pinching load amplitude: The probability is slightly reduced from a range of less than 0.0333% to 0.1667% for P{sub 9m}, to a range of less than 0.0333% to 0.1333% for P{sub AS}, depending on the vacuum drying peak cladding hoop stress modelling assumptions. Further, the SNF dry-storage duration does not significantly affect the probability of ductile pinching failure. Based on available train accidents data, the pinching failure probability for a 5,000 km long transportation route ranges from less than 1.62 E-7 to a value of 6.47 E-7, depending on the vacuum drying peak cladding hoop stress modelling assumptions. The pinching load amplitude is not a controlling parameter for the probability of ductile cladding pinching failure, and does not control the cladding deformations once pellet-cladding contact is established, The pellet-cladding gap width, however, plays a key role. Fuel pellet degradation only affects the deformation capacity, if the pellet stiffness is significantly reduced (more than 90%). Only highly embrittled cladding is likely to fail. The deformation demands on the cladding under pinching loading are small.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗