Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Multi-Level Anomaly Detection on Time-Varying Graph Data

This work presents a novel modeling and analysis framework for graph sequences which addresses the challenge of detecting and contextualizing anomalies in labelled, streaming graph data. We introduce a generalization of the BTER model of Seshadhri et al. by adding flexibility to community structure, and use this model to perform multi-scale graph anomaly detection. Specifically, probability models describing coarse subgraphs are built by aggregating probabilities at finer levels, and these closely related hierarchical models simultaneously detect deviations from expectation. This technique provides insight into a graph's structure and internal context that may shed light on a detected event. Additionally, this multi-scale analysis facilitates intuitive visualizations by allowing users to narrow focus from an anomalous graph to particular subgraphs or nodes causing the anomaly. For evaluation, two hierarchical anomaly detectors are tested against a baseline Gaussian method on a series of sampled graphs. We demonstrate that our graph statistics-based approach outperforms both a distribution-based detector and the baseline in a labeled setting with community structure, and it accurately detects anomalies in synthetic and real-world datasets at the node, subgraph, and graph levels. To illustrate the accessibility of information made possible via this technique, the anomaly detector and an associated interactive visualization tool are tested on NCAA football data, where teams and conferences that moved within the league are identified with perfect recall, and precision greater than 0.786.

anomaly detection↗

Salt Sample Statistical Study

Historically there has, at times, been large variability in measured uranium concentration amongst salt samples taken at the same time from the electrorefiner with relative standard deviations ranging from 0.59% up to a high of 114%. This has led to uncertainty in the actual uranium content of the salt. A series of surrogate experiments were performed with gadolinium to study the effects of Li2O, Gd2O3, and Gd metal additions to an LiCl-KCl-GdCl3 salt on the gadolinium content of the salt. These experiments showed no increase in salt sample variability following the additions of the mentioned species, indicating that the carryover of these species from the oxide reduction process may not lead to the historic variability issues.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-C-12A-04: Diagnostic Imaging Research Using Decedents as a Proxy for the Living: Are Radiation Dosimetry and Tissue Property Measurements Affected by Post-Mortem Changes?

Purpose: Radiation dose (RD) from diagnostic imaging is a growing public health concern. Implanting dosimeters is a more accurate way to assess organ dose, relative to commonly used mathematical estimations. However, performing accurate dosimetry using live subjects is hindered by patient motion and safety considerations, which limit the RD and placement of implanted dosimeters. Performing multiple scans on the same subject would be the ideal way to assess the impact of dose reduction on image quality; however, performing multiple non-standard-of-care scans on live subjects for dosimetry and image quality measurements is generally prohibited by IRB committees. Our objective is to assess whether RD and tissue property (TP) measurements in post-mortem (PM) subjects are sufficiently similar to those in live subjects to justify the use of deceased subjects in future dosimetry and image quality studies. Methods: 4 MOSFET radiation dosimeters were placed enterically in each subject (2 sedated Rhesus Macaques) to measure the RD at 4 levels (carina, lung, heart, and liver) during CT scanning. The CT protocol was performed ante-mortem (AM) and 2 and 3 hours PM. For TP analysis, additional scans were taken at 24 hours PM. To compare AM and PM TP, regions-of-interest were drawn on selected organs and the average CT density with standard deviation (in units of HU) were taken; additionally, visual comparisons of images were made at each PM interval. Results: No significant difference was observed in 8 of 9 measurements comparing AM and PM RD. Only one measurement (liver of the first subject) showed a significant difference (7% lower on PM measurement), possibly due to subject re-positioning. Initial TP visual and quantitative analyses show little to no change PM. Conclusion: Our results suggest that realistic radiation dosimetry and image quality measurements based on tissue properties can be performed reliably on recently deceased subjects.

60 APPLIED LIFE SCIENCES↗

Electrochemical Immunoassay of Cotinine in Serum Based on Nanoparticle Probe and Immunochromatographic Strip

A disposable sensor for the determination of cotinine in human serum was developed based on immunochromatographic test strip and quantum dot label. In this assay, cotinine modified on quantum dot competes with cotinine in sample to bind to anti-cotinine antibody in the test strip and the quantum dots serve as signal vehicles for electrochemical readout. Some parameters governing the performance of the sensor were optimized. The sensor shows a wide linear range from 1 ng mL-1 to 100 ng mL-1 cotinine with a detection limit of 1.0 ng mL-1. The relative standard deviation (R.S.D.) of the sensor was less than 2% for cotinine. The sensor was validated with spiked human serum samples and it was found that this method was reliable in measuring cotinine in human serum with average recovery of 100.99%. The results demonstrate that this sensor is a rapid, clinically accurate, and less expensive and has the potential for point of care (POC) detection of cotinine and fast screening of tobacco smoke exposure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Search for single top quark production in pp collisions at {radical}(s)=1.96 TeV in the missing transverse energy plus jets topology

We report a search for single top quark production with the CDF II detector using 2.1 fb{sup -1} of integrated luminosity of pp collisions at {radical}(s)=1.96 TeV. The data selected consist of events characterized by large energy imbalance in the transverse plane and hadronic jets, and no identified electrons and muons, so the sample is enriched in W{yields}{tau}{nu} decays. In order to suppress backgrounds, additional kinematic and topological requirements are imposed through a neural network, and at least one of the jets must be identified as a b quark jet. We measure an excess of signal-like events in agreement with the standard model prediction, but inconsistent with a model without single top quark production by 2.1 standard deviations ({sigma}), with a median expected sensitivity of 1.4{sigma}. Assuming a top quark mass of 175 GeV/c{sup 2} and ascribing the excess to single top quark production, the cross section is measured to be 4.9{sub -2.2}{sup +2.5}(stat+syst) pb, consistent with measurements performed in independent data sets and with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microstructure Scale Lithium-Ion Battery Modeling, Part IV: The Representativity of Microstructure Parameters and Electrochemical Response

Lithium-ion battery electrochemical models require an accurate description of the electrodes microstructures to be predictive, that can be achieved through nanoscale imaging. Such observations are however limited by their field of view (FOV), as they provide only a subset of the whole electrode volume that does not necessarily represent the whole electrode microstructure heterogeneity, and therefore can bias the analysis. A representativity analysis has been performed on the microstructure parameters and, in a novel way, on the full cell electrochemical response to evaluate the predictions representativeness, and thus relevance, of a microstructure scale electrochemical model. The microstructure parameter deviation propagations to the electrochemical response have been quantified for different charge rates. This defines a threshold for the microstructure parameters FOV for a desired maximum deviation of the electrochemical response. Electrochemical model shows cell representative section areas are increasing with C-rate, due to higher in-plane heterogeneities, indicating larger FOVs are required specifically for fast charge modeling. Representativity analysis determines a cell FOV of 144.4 × 154.4 μm 2 is large enough to establish a convergence on the representative section areas for low-intermediate C-rate (≤2.5 C), therefore positively concludes on the model representativeness for these rates, but is not large enough to conclude for higher rates.

25 ENERGY STORAGE↗

Optimal gate-width setting for passive neutrons multiplicity counting

When setting up a passive neutron coincidence counter it is natural to ask what coincidence gate settings should be used to optimize the counting precision. If the gate width is too short then signal is lost and the precision is compromised because in a given period only a few coincidence events will be observed. On the other hand if the gate is too large the signal will be maximized but it will also be compromised by the high level of random pile-up or Accidental coincidence events which must be subtracted. In the case of shift register electronics connected to an assay chamber with an exponential dieaway profile operating in the regime where the Accidentals rate dominates the Reals coincidence rate but where dead-time is not a concern, simple arguments allow one to show that the relative precision on the net Reals rate is minimized when the coincidence gate is set to about 1.2 times the lie dieaway time of the system. In this work we show that making the same assumptions it is easy to show that the relative precision on the Triples rates is also at a minimum when the relative precision of the Doubles (or Reals) is at a minimum. Although the analysis is straightforward to our knowledge such a discussion has not been documented in the literature before. Actual measurement systems do not always behave in the ideal we choose to model them. Fortunately however the variation in the relative precision as a function of gate width is rather flat for traditional safeguards counters and so the performance is somewhat forgiving of the exact choice. The derivation further serves to delineate the important parameters which determine the relative counting precision of the Doubles and Triples rates under the regime considered. To illustrate the similarities and differences we consider the relative standard deviation that might be anticipated for a passive correlation count of an axial section of a spent nuclear fuel assembly under practically achievable conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optically read Coriolis vibratory gyroscope based on a silicon tuning fork

In this work, we describe the design, fabrication, and characterization of purely mechanical miniature resonating structures that exhibit gyroscopic performance comparable to that of more complex microelectromechanical systems. Compared to previous implementations of Coriolis vibratory gyroscopes, the present approach has the key advantage of using excitation and probing that do not require any on-chip electronics or electrical contacts near the resonating structure. More specifically, our design relies on differential optical readout, each channel of which is similar to the 'optical lever' readout used in atomic force microscopy. The piezoelectrically actuated stage provides highly efficient excitation of millimeter-scale tuning fork structures that were fabricated using widely available high-throughput wafer-level silicon processing. In our experiments, reproducible responses to rotational rates as low as 1.8 × 10 3° h –1 were demonstrated using a benchtop prototype without any additional processing of the raw signal. The noise-equivalent rate, ΩNER, derived from the Allan deviation plot, was found to be <0.5° h –1 for a time of 10 3 s. Despite the relatively low Q factors (<10 4 ) of the tuning fork structures operating under ambient pressure and temperature conditions, the measured performance was not limited by thermomechanical noise. In fact, the performance demonstrated in this proof-of-principle study is approximately four orders of magnitude away from the fundamental limit.

36 MATERIALS SCIENCE↗

Uncertainty Quantification Enabled by Automatic Differentiation for Hydrodynamic Simulation of Shock‐to‐Detonation Transition in High Explosives

Quantifying the effects of uncertainty in a reactive burn model on the run-to-detonation time in high explosives (HEs) provides a robust methodology for assessing the probability of an HE failing the IHE qualification standard. Moreover, uncertainty quantification helps evaluate whether the model calibration accurately represents data outside the calibration set. This study uses a specialized hydrodynamic simulation code for modeling detonation to determine the run-to-detonation time of the HE PBX 9502 for various impact velocities. To quickly approximate uncertainties in the model, a surrogate was constructed using a Taylor series expansion centered at the mean of the input parameters. To obtain the sensitivities required for constructing the Taylor series, HYP-percomplex Automatic Differentiation (HYPAD) was implemented. HYPAD is a methodology for infusing existing codes with automatic differentiation capabilities by augmenting variables with one or more imaginary units to compute step-size independent partial derivatives. These derivatives are accurate to machine precision with respect to the implemented numerical algorithm, meaning their accuracy reflects that of the underlying method (e.g., integration or discretization schemes). Using reduced order modeling techniques, the mean and standard deviation of the run-to-detonation time of a shock within PBX 9502 were computed for a number of initial impact velocities. A weighted least squares regression was then performed to obtain a best fit curve and prediction interval for the computed statistics. Historical data points from explosively driven wedge tests were utilized to validate the prediction interval, ensuring its reliability in predicting future outcomes. With this prediction interval and a known safety constraint curve, the most probable point of failure and the probability of failure for the HE PBX 9502 were determined.

97 MATHEMATICS AND COMPUTING↗

Diagram, valence-to-core, and hypersatellite K β X-ray transitions in metallic chromium

Here, we identify measurements of the K β diagram, valence-to-core (VtC), and hypersatellite X-ray spectra induced in metallic Cr by photon single and double K-shell ionization. The experiment was carried out at the Stanford Synchrotron Radiation Lightsource using the seven-crystal Johann-type hard X-ray spectrometer of the beamline 6-2. For the K β diagram and VtC transitions, the present study confirms the line shape features observed in previous works, whereas the K h β hypersatellite transition was found to exhibit a complex spectral line shape and a characteristic low-energy shoulder. The energy shift of the hypersatellite relative to the parent diagram line was deduced from the measurements and compared with the result of extensive multiconfiguration Dirac–Fock (MCDF) calculations. A signifcant agreement between experiment and theory was found. The MCDF calculations were also used to compute the theoretical line shape of the hypersatellite. A satisfactory agreement was obtained between the overall shapes of the experimental and theoretical spectra, but deviations were observed on the low- and high-energy flanks of the hypersatellite line. The discrepancies were explained by chemical effects, which were not considered in the MCDF calculations performed for isolated atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of proton-tagged, central (semi)exclusive production of high-mass lepton pairs in pp collisions at 13 TeV with the CMS-TOTEM precision proton spectrometer

The process pp → pℓ$^{+}$ℓ$^{−}$p$^{(*)}$, with ℓ$^{+}$ℓ$^{−}$ a muon or an electron pair produced at midrapidity with mass larger than 110 GeV, has been observed for the first time at the LHC in pp collisions at $ \sqrt{s}=13 $ TeV. One of the two scattered protons is measured in the CMS-TOTEM precision proton spectrometer (CT-PPS), which operated for the first time in 2016. The second proton either remains intact or is excited and then dissociates into a low-mass state p$^{*}$, which is undetected. The measurement is based on an integrated luminosity of 9.4 fb$^{−1}$ collected during standard, high-luminosity LHC operation. A total of 12 μ$^{+}$μ$^{−}$ and 8 e$^{+}$e$^{−}$ pairs with m(ℓ$^{+}$ℓ$^{−}$) > 110 GeV, and matching forward proton kinematics, are observed, with expected backgrounds of 1.49 ± 0.07 (stat) ± 0.53 (syst) and 2.36 ± 0.09 (stat) ± 0.47 (syst), respectively. This corresponds to an excess of more than five standard deviations over the expected background. The present result constitutes the first observation of proton-tagged γγ collisions at the electroweak scale. This measurement also demonstrates that CT-PPS performs according to the design specifications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An optimal guarding scheme for thermal conductivity measurement using a guarded cut-bar technique, part 1 experimental study

In the guarded cut-bar technique, a guard surrounding the measured sample and reference (meter) bars is temperature controlled to carefully regulate heat losses from the sample and reference bars. Guarding is typically carried out by matching the temperature profiles between the guard and the test stack of sample and meter bars. Problems arise in matching the profiles, especially when the thermal conductivitiesof the meter bars and of the sample differ, as is usually the case. In a previous numerical study, the applied guarding condition (guard temperature profile) was found to be an important factor in measurement accuracy. Different from the linear-matched or isothermal schemes recommended in literature, the optimal guarding condition is dependent on the system geometry and thermal conductivity ratio of sample to meter bar. To validate the numerical results, an experimental study was performed to investigate the resulting error under different guarding conditions using stainless steel 304 as both the sample and meter bars. The optimal guarding condition was further verified on a certified reference material, pyroceram 9606, and 99.95% pure iron whose thermal conductivities are much smaller and much larger, respectively, than that of the stainless steel meter bars. Additionally, measurements are performed using three different inert gases to show the effect of the insulation effective thermal conductivity on measurement error, revealing low conductivity, argon gas, gives the lowest error sensitivity when deviating from the optimal condition. The result of this study provides a general guideline for the specific measurement method and for methods requiring optimal guarding or insulation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Frankenstein’s ROMster: Avoiding pitfalls of reduced-order model development

Reduced-order models (ROMs) are a widely used and powerful approach to reducing the complexity of predictive physics-based numerical simulations for a wide range of applications, including electronics and fluid mechanics such as geologic CO 2 sequestration (GCS). ROMs are critical for optimization, sensitivity analysis, model calibration and uncertainty quantification where full-order models cannot be feasibly executed many times. Traditional approaches generate a single ROM for each simulated response (e.g., CO 2 injection rates, pH changes) based on a set of training simulations. Here, we demonstrate that a single ROM can display excellent overall predictive statistics, but have predictions that dramatically and unacceptably deviate from simulator responses especially when the response variable has a large range (i.e., vary over multiple orders of magnitude). For example, we show that a traditional statistically-high-performing GCS ROM (coefficient of determination R 2 of 0.99) can have average absolute relative errors of over 200%. To address this, we propose a new and novel approach where a set of sub-ROMs are generated to overcome the potential pitfalls in traditional single ROM development. The effectiveness of the proposed approach—the ROMster framework—is demonstrated using a case study of predicted CO 2 injection rates for GCS. We find our approach is a robust and general framework for ROM development, reducing the average “error” from 200% to only 4% in our case study.

54 ENVIRONMENTAL SCIENCES↗

When Is CT-Based Postoperative Seroma Most Useful to Plan Partial Breast Radiotherapy? Evaluation of Clinical Factors Affecting Seroma Volume and Clarity

Purpose: To evaluate the effect of the time from surgery and other clinical factors on seroma volume and clarity and establish the optimal time to use the computed tomography (CT)-based seroma to plan partial breast irradiation (PBI). Methods and Materials: A total of 205 women with early-stage breast cancer underwent planning CT after breast-conserving surgery. One radiation oncologist contoured the seroma volume and scored the seroma clarity, using a standardized Seroma Clarity Score scale, from 0 (not detectable) to 5 (clearest). Univariate and multivariate analyses were performed to evaluate the associations between the seroma characteristics and the interval from surgery and other clinical factors. Results: The mean interval from surgery to CT was 84 days (standard deviation 59). During postoperative Weeks 3-8, the mean seroma volume decreased from 47 to 30 cm{sup 3}, stabilized during Weeks 9-14 (mean 21) and was involuted beyond 14 weeks (mean 9 cm{sup 3}). The mean seroma clarity score was 3.4 at Weeks 3-8, 2.5 at Weeks 9-14, and 1.6 after 14 weeks. The seroma clarity was greater in patients aged {>=}70 years. The seroma volume and clarity correlated significantly with the volume of excised breast tissue but not with the maximal tumor diameter, surgical re-excision, or chemotherapy use. Conclusion: The optimal time to obtain the planning CT scan for PBI is within 8 weeks after surgery. During Weeks 9-14, the seroma might remain adequately defined in some patients; however, after 14 weeks, alternate strategies are needed to identify the PBI target. The lack of correlation between the seroma volume and tumor size suggests that the CT-based seroma should not be the sole guide for PBI target volume definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Study of Cone-Beam Computed Tomography Image-Guided Radiotherapy for Prone Accelerated Partial Breast Irradiation

Purpose: To report setup variations during prone accelerated partial breast irradiation (APBI). Methods: New York University (NYU) 07-582 is an institutional review board-approved protocol of cone-beam computed tomography (CBCT) to deliver image-guided ABPI in the prone position. Eligible are postmenopausal women with pT1 breast cancer excised with negative margins and no nodal involvement. A total dose of 30 Gy in five daily fractions of 6 Gy are delivered to the planning target volume (the tumor cavity with 1.5-cm margin) by image-guided radiotherapy. Patients are set up prone, on a dedicated mattress, used for both simulation and treatment. After positioning with skin marks and lasers, CBCTs are performed and the images are registered to the planning CT. The resulting shifts (setup corrections) are recorded in the three principal directions and applied. Portal images are taken for verification. If they differ from the planning digital reconstructed radiographs, the patient is reset, and a new CBCT is taken. Results: 70 consecutive patients have undergone a total of 343 CBCTs: 7 patients had four of five planned CBCTs performed. Seven CBCTs (2%) required to be repeated because of misalignment in the comparison between portal and digital reconstructed radiograph image after the first CBCT. The mean shifts and standard deviations in the anterior-posterior (AP), superior-inferior (SI), and medial-lateral (ML) directions were -0.19 (0.54), -0.02 (0.33), and -0.02 (0.43) cm, respectively. The average root mean squares of the daily shifts were 0.50 (0.28), 0.29 (0.17), and 0.38 (0.20). A conservative margin formula resulted in a recommended margin of 1.26, 0.73, 0.96 cm in the AP, SI, and ML directions. Conclusion: CBCTs confirmed that the NYU prone APBI setup and treatment technique are reproducible, with interfraction variation comparable to those reported for supine setup. The currently applied margin (1.5 cm) adequately compensates for the setup variation detected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of EORTC Target Definition Guidelines for Dose-Intensified Salvage Radiation Therapy for Recurrent Prostate Cancer: Results of the Quality Assurance Program of the Randomized Trial SAKK 09/10

Purpose: Different international target volume delineation guidelines exist and different treatment techniques are available for salvage radiation therapy (RT) for recurrent prostate cancer, but less is known regarding their respective applicability in clinical practice. Methods and Materials: A randomized phase III trial testing 64 Gy vs 70 Gy salvage RT was accompanied by an intense quality assurance program including a site-specific and study-specific questionnaire and a dummy run (DR). Target volume delineation was performed according to the European Organisation for the Research and Treatment of Cancer guidelines, and a DR-based treatment plan was established for 70 Gy. Major and minor protocol deviations were noted, interobserver agreement of delineated target contours was assessed, and dose-volume histogram (DVH) parameters of different treatment techniques were compared. Results: Thirty European centers participated, 43% of which were using 3-dimensional conformal RT (3D-CRT), with the remaining centers using intensity modulated RT (IMRT) or volumetric modulated arc technique (VMAT). The first submitted version of the DR contained major deviations in 21 of 30 (70%) centers, mostly caused by inappropriately defined or lack of prostate bed (PB). All but 5 centers completed the DR successfully with their second submitted version. The interobserver agreement of the PB was moderate and was improved by the DR review, as indicated by an increased κ value (0.59 vs 0.55), mean sensitivity (0.64 vs 0.58), volume of total agreement (3.9 vs 3.3 cm{sup 3}), and decrease in the union volume (79.3 vs 84.2 cm{sup 3}). Rectal and bladder wall DVH parameters of IMRT and VMAT vs 3D-CRT plans were not significantly different. Conclusions: The interobserver agreement of PB delineation was moderate but was improved by the DR. Major deviations could be identified for the majority of centers. The DR has improved the acquaintance of the participating centers with the trial protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Applied metrology in the production of superconducting model magnets for particle accelerators

The production of superconducting magnets for particle accelerators involves high precision assemblies and tight tolerances, in order to achieve the requirements for their appropriate performance. It is therefore essential to have a strict control and traceability over the geometry of each component of the system, and also to be able to compensate possible inherent deviations coming from the production process.

43 PARTICLE ACCELERATORS↗

Monte Carlo-based simulation of dynamic jaws tomotherapy

Purpose: Original TomoTherapy systems may involve a trade-off between conformity and treatment speed, the user being limited to three slice widths (1.0, 2.5, and 5.0 cm). This could be overcome by allowing the jaws to define arbitrary fields, including very small slice widths (<1 cm), which are challenging for a beam model. The aim of this work was to incorporate the dynamic jaws feature into a Monte Carlo (MC) model called TomoPen, based on the MC code PENELOPE, previously validated for the original TomoTherapy system. Methods: To keep the general structure of TomoPen and its efficiency, the simulation strategy introduces several techniques: (1) weight modifiers to account for any jaw settings using only the 5 cm phase-space file; (2) a simplified MC based model called FastStatic to compute the modifiers faster than pure MC; (3) actual simulation of dynamic jaws. Weight modifiers computed with both FastStatic and pure MC were compared. Dynamic jaws simulations were compared with the convolution/superposition (C/S) of TomoTherapy in the ''cheese'' phantom for a plan with two targets longitudinally separated by a gap of 3 cm. Optimization was performed in two modes: asymmetric jaws-constant couch speed (''running start stop,'' RSS) and symmetric jaws-variable couch speed (''symmetric running start stop,'' SRSS). Measurements with EDR2 films were also performed for RSS for the formal validation of TomoPen with dynamic jaws. Results: Weight modifiers computed with FastStatic were equivalent to pure MC within statistical uncertainties (0.5% for three standard deviations). Excellent agreement was achieved between TomoPen and C/S for both asymmetric jaw opening/constant couch speed and symmetric jaw opening/variable couch speed, with deviations well within 2%/2 mm. For RSS procedure, agreement between C/S and measurements was within 2%/2 mm for 95% of the points and 3%/3 mm for 98% of the points, where dose is greater than 30% of the prescription dose (gamma analysis). Dose profiles acquired in transverse and longitudinal directions through the center of the phantom were also compared with excellent agreement (2%/2 mm) between all modalities. Conclusions: The combination of weights modifiers and interpolation allowed implementing efficiently dynamic jaws and dynamic couch features into TomoPen at a minimal cost in terms of efficiency (simulation around 8 h on a single CPU).

62 RADIOLOGY AND NUCLEAR MEDICINE↗