Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

X-ray Phase Contrast analysis - Digital wavefront development

Optical schemes that enable imaging of the phase shift produced by an object have become popular in the x-ray region, where phase can be the dominant contrast mechanism. The propagation-based technique consists of recording the interference pattern produced by choosing one or several sample-to-detector distances. Pioneering studies, carried out making use of synchrotron radiation, demonstrated that this technique results in a dramatic increase of image contrast and detail visibility, allowing the detection of structures invisible with conventional techniques. An experimental and theoretical study of in-line hard x-ray phase-contrast imaging had been performed. The theoretical description of the technique is based on Fresnel diffraction. As an illustration of the potential of this quantitative imaging technique, high-resolution x-ray phase contrast images of simple objects will be presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Highly efficient electron vortex beams generated by nanofabricated phase holograms

We propose an improved type of holographic-plate suitable for the shaping of electron beams. The plate is fabricated by a focused ion beam on a silicon nitride membrane and introduces a controllable phase shift to the electron wavefunction. We adopted the optimal blazed-profile design for the phase hologram, which results in the generation of highly efficient (25%) electron vortex beams. This approach paves the route towards applications in nano-scale imaging and materials science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tunable Pseudogap Kondo Effect and Quantum Phase Transitions in Aharonov-Bohm Interferometers

We study two quantum dots embedded in the arms of an Aharonov-Bohm ring threaded by a magnetic flux. This system can be described by an effective one-impurity Anderson model with an energy- and flux- dependent density of states. For specific values of the flux, this density of states vanishes at the Fermi energy, yielding a controlled realization of the pseudogap Kondo effect. The conductance and trans- mission phase shifts reflect a nontrivial interplay between wave interference and interactions, providing clear signatures of quantum phase transitions between Kondo and non-Kondo ground states.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

On the Feasibility of Efficient Multiamplitude Communication

Bandwidth constraints in earth-satellite communication systems force consideration of uncoded M-ary modulation to obtain increased data rates. M-ary phase shift keying (MPSK) at first glance seems most promising because of the high transmitter efficiency achieved through Class C operation. Multiple phase-and-amplitude modulation candidates such as quadrature amplitude shift keying (QASK) appear less promising because the transmitter must operate at lower efficiency (in linear or multimode operation). However, initial studies indicate that QASK offers significant raw dc-power savings over MPSK, despite the reduced transmitter efficiency. For example, at S-band both solid-state and traveling wave tube (TWT) QASK transmitters can provide a 3-dB average dc-power savings over comparable 16-ary phase shift keying (PSK) for the same bit rate and error probability. The reason for this savings is that QASK requires much less average signal-to-noise ratio than 16-ary PSK for the same error rate.

Smith, J. G.↗

Influence of the antenna toroidal spectrum on ICRF heating scenarios in ITER

Owing to the features of ion cyclotron waves, kinetic full wave simulations are necessary to plan ICRH scenarios for ITER and precisely assess their respective merits, incorporating all possibly relevant physics phenomena. For instance, both experiments and numerical simulations have identified the important role of the distribution of the antenna current in the toroidal direction. However, owing to the large computational resources necessary to accurately simulate these experiments, the antenna spectrum is generally simplified, often by retaining only the dominant toroidal number. Extensive simulations of ICRF heating in the activated phase of ITER have been performed, using the multidimensional full wave code EVE. The results obtained for various inter-strap phase shifts are presented, and compared to single toroidal mode-based simulations. The impact of the antenna phasing on the power deposition profiles and power split between the plasma species is evaluated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of CO{sub 2} laser dispersion interferometer with photoelastic modulator

A dispersion interferometer is one of the promising methods of the electron density measurement on large and high density fusion devices. This paper describes development of a CO{sub 2} laser dispersion interferometer with a photoelastic modulator for phase modulation. In order to make the dispersion interferometer free from variations of the detected intensity, a new phase extraction method is introduced: The phase shift is evaluated from a ratio of amplitudes of the fundamental and the second harmonics of the phase modulation frequency in the detected interference signal. The proof-of-principle experiments demonstrate the feasibility of this method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid crystal terahertz phase shifters with functional indium-tin-oxide nanostructures for biasing and alignment

Indium Tin Oxide (ITO) nanowhiskers (NWhs) obliquely evaporated by electron-beam glancing-angle deposition can serve simultaneously as transparent electrodes and alignment layer for liquid crystal (LC) devices in the terahertz (THz) frequency range. To demonstrate, we constructed a THz LC phase shifter with ITO NWhs. Phase shift exceeding π/2 at 1.0 THz was achieved in a ∼517 μm-thick cell. The phase shifter exhibits high transmittance (∼78%). The driving voltage required for quarter-wave operation is as low as 5.66 V (rms), compatible with complementary metal-oxide-semiconductor (CMOS) and thin-film transistor (TFT) technologies.

36 MATERIALS SCIENCE↗

High harmonic phase in molecular nitrogen

Electronic structure in atoms and molecules modulates the amplitude and phase of high harmonic generation (HHG). We report measurements of the high harmonic spectral amplitude and phase in N{sub 2}. The phase is measured interferometrically by beating the N{sub 2} harmonics with those of an Ar reference oscillator in a gas mixture. A rapid phase shift of 0.2{pi} is observed in the vicinity of the HHG spectral minimum, where a shift of {pi} had been presumed [J. Itatani et al., Nature 432, 867 (2004)]. We compare the phase measurements to a simulation of the HHG recombination step in N{sub 2} that is based on a simple interference model. The results of the simulation suggest that modifications beyond the simple interference model are needed to explain HHG spectra in molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deconvolution by finite-size-source effects of x-ray phase-contrast images

Purpose: In the hard x-ray region, the cross sections for the phase shift of low-Z elements are about 1000 times larger than the absorption ones. As a consequence, phase contrast is detectable even when absorption contrast is minimal or absent. Therefore, phase-contrast imaging could become a valid alternative to absorption contrast without delivering high dose to tissue/human body parts. Methods: To enhance the quality of phase-contrast images without increasing the dose, a possible approach could be the partial deconvolution of the finite source size effects by experimental phase-contrast images. The deconvolution procedure, the authors propose, employs the acquisition of two images on a suitable well-known test sample, one in contact and the other in phase-contrast conditions. Both acquired images are used along with a simulated phase-contrast image (obtained from the test sample in ideal conditions of pointlike source illumination) to correctly retrieve the experimental source distribution function. This information allows a generic experimental phase-contrast image, acquired in the same conditions, to be partially deconvolved by finite source size effects. Results: The performed experimental tests indicate that deconvolved images are equivalent to those which would be obtained with a source 40% smaller than the actual size. In turn, this finding is equivalent to an increase of the ''effective'' lateral spatial coherence length. The corresponding quality improvement of the phase-contrast imaging is directly deducible by the presence of many Fresnel fringes, much better visible with respect to the original experimental phase-contrast images. Conclusions: The use of a test standard sample, always possible in every experimental setup, to partially deconvolve the finite-size-source blurring effects shows that higher quality phase-contrast images could be readily available, making easier diagnoses and tissue/sample analyses. The method could give, in the future, the possibility to further lower the delivered dose to patients, organs, and tissues when compact room-sized and brilliant microfocus x-ray sources will be available for clinical applications in hospitals.

60 APPLIED LIFE SCIENCES↗

Magnonic crystals-based tunable microwave phase shifters

Tunable microwave phase shifters using magnetostatic backward volume waves in yttrium iron garnet/gadolinium gallium garnet thin film-based one-dimensional (1-D) and two-dimensional (2-D) magnonic crystals (MCs) are reported in this paper. Large differential phase shifts with small insertion loss variations were achieved in the passbands neighboring the bandgaps by tuning of the bias magnetic field. Large phase tuning rates up to 13.48 °/(Oe cm) and 25.9 °/(Oe cm) together with small insertion loss variations of 2.08 dB/cm and 0.97 dB/cm were demonstrated in the 1-D and 2-D MCs, respectively. An excellent agreement between the measured and the calculated results based on Walker's equation was obtained.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Beam hardening effects in grating-based x-ray phase-contrast imaging

Purpose: In this work, the authors investigate how beam hardening affects the image formation in x-ray phase-contrast imaging and consecutively develop a correction algorithm based on the results of the analysis. Methods: The authors' approach utilizes a recently developed x-ray imaging technique using a grating interferometer capable of visualizing the differential phase shift of a wave front traversing an object. An analytical description of beam hardening is given, highlighting differences between attenuation and phase-contrast imaging. The authors present exemplary beam hardening artifacts for a number of well-defined samples in measurements at a compact laboratory setup using a polychromatic source. Results: Despite the differences in image formation, the authors show that beam hardening leads to a similar reduction of image quality in phase-contrast imaging as in conventional attenuation-contrast imaging. Additionally, the authors demonstrate that for homogeneous objects, beam hardening artifacts can be corrected by a linearization technique, applicable to all kinds of phase-contrast methods using polychromatic sources. Conclusions: The evaluated correction algorithm is shown to yield good results for a number of simple test objects and can thus be advocated in medical imaging and nondestructive testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced cross-Kerr nonlinearity via electromagnetically induced transparency in a four-level tripod atomic system

We investigate, both theoretically and experimentally, the cross-Kerr nonlinearity generated in a four-level tripod system in the {sup 87}Rb D1 line. The system exhibits simultaneous electromagnetically induced transparency (EIT) windows for two weak (probe and trigger) fields and the enhanced cross-Kerr nonlinearity by EIT. The cross-Kerr nonlinear phase shifts for probe (trigger) field are measured at several different intensities of trigger (probe) field. The results show that large cross-phase modulation (XPM) coefficients can be achieved at low light intensities.

74 ATOMIC AND MOLECULAR PHYSICS↗

Phase control of the Pancharatnam phase

We propose a method to control the atomic dynamics in the presence of electromagnetic fields. Instead of measuring the population dynamics, we focus on the possibility of controlling the Pancharatnam phase. For a two-level system we find that this phase can be optically induced and controlled by the phase shift. More importantly, the nonlinear interaction between the atom and the field leads to an enhanced sensitivity for the control of the atomic phase evolution and system dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗