Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Design of a technique to measure the density of ultracold atoms in a short-period optical lattice in three dimensions with single-atom sensitivity

A measurement technique is described that has the potential to map the atomic site occupancies of ultracold atoms in a short-period three-dimensional optical lattice. The method uses accordion and pinning lattices, together with polarization gradient cooling and fluorescence detection, to measure the positions of individual atoms within the sample in three dimensions at a resolution of around half the atomic resonant wavelength. The method measures the site occupancy, rather than the parity of the site occupancy, of atoms in the lattice. It is expected that such measurements hold significant potential for the study of ultracold quantum dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Crystal structure of the antigen-binding fragment of a monoclonal antibody specific for the multidrug-resistance-linked ABC transporter human P-glycoprotein

P-glycoprotein (P-gp) is a polyspecific ATP-dependent transporter linked to multidrug resistance in cancers that plays important roles in the pharmacokinetics of a large number of drugs. The drug-resistance phenotype of P-gp can be modulated by the monoclonal antibody UIC2, which specifically recognizes human P-gp in a conformation-dependent manner. Here, the purification, sequence determination and high-resolution structure of the Fab fragment of UIC2 (UIC2/Fab) are reported. Purified UIC2/Fab binds human P-gp with a 1:1 stoichiometry. Crystals of UIC2/Fab are triclinic (space group P 1), with unit-cell parameters a = 40.67, b = 44.91, c = 58.09 Å, α = 97.62, β = 99.10, γ = 94.09°, and diffracted X-rays to 1.6 Å resolution. The structure was determined by molecular replacement and refined to 1.65 Å resolution. The asymmetric unit contains one molecule of UIC2/Fab, which exhibits a positively charged antigen-binding surface, suggesting that it might recognize an oppositely charged extracellular epitope of P-gp.

59 BASIC BIOLOGICAL SCIENCES↗

Structure of the Bacillus anthracis dTDP- L -rhamnose-biosynthetic enzyme glucose-1-phosphate thymidylyltransferase (RfbA)

L-Rhamnose is a ubiquitous bacterial cell-wall component. The biosynthetic pathway for its precursor dTDP-L-rhamnose is not present in humans, which makes the enzymes of the pathway potential drug targets. In this study, the three-dimensional structure of the first protein of this pathway, glucose-1-phosphate thymidylyltransferase (RfbA), from Bacillus anthracis was determined. In other organisms this enzyme is referred to as RmlA. RfbA was co-crystallized with the products of the enzymatic reaction, dTDP-α-D-glucose and pyrophosphate, and its structure was determined at 2.3 Å resolution. This is the first reported thymidylyltransferase structure from a Gram-positive bacterium. RfbA shares overall structural characteristics with known RmlA homologs. However, RfbA exhibits a shorter sequence at its C-terminus, which results in the absence of three α-helices involved in allosteric site formation. Consequently, RfbA was observed to exhibit a quaternary structure that is unique among currently reported glucose-1-phosphate thymidylyltransferase bacterial homologs. These structural analyses suggest that RfbA may not be allosterically regulated in some organisms and is structurally distinct from other RmlA homologs.

59 BASIC BIOLOGICAL SCIENCES↗

Structure of NADP + -dependent glutamate dehydrogenase from Escherichia coli - reflections on the basis of coenzyme specificity in the family of glutamate dehydrogenases

Glutamate dehydrogenases catalyse the oxidative deamination of L -glutamate to α-ketoglutarate, using NAD + and/or NADP + as a cofactor. Subunits of homo-hexameric bacterial enzymes comprise a substrate-binding domain I followed by a nucleotide-binding domain II. The reaction occurs in a catalytic cleft between the two domains. Although conserved residues in the nucleotide-binding domains of various dehydrogenases have been linked to cofactor preferences, the structural basis for specificity in the GDH family remains poorly understood. Here, the refined crystal structure of Escherichia coli GDH in the absence of reactants is described at 2.5-Å resolution. Modelling of NADP + in domain II reveals the potential contribution of positively charged residues from a neighbouring α-helical hairpin to phosphate recognition. In addition, a serine that follows the P7 aspartate is presumed to form a hydrogen bond with the 2'-phosphate. Mutagenesis and kinetic analysis confirms the importance of these residues in NADP + recognition. Surprisingly, one of the positively charged residues is conserved in all sequences of NAD + -dependent enzymes, but the conformations adopted by the corresponding regions in proteins whose structure has been solved preclude their contribution to the coordination of the 2'-ribose phosphate of NADP + . These studies clarify the sequence–structure relationships in bacterial GDHs, revealing that identical residues may specify different coenzyme preferences, depending on the structural context. Primary sequence alone is therefore not a reliable guide for predicting coenzyme specificity. We also consider how it is possible for a single sequence to accommodate both coenzymes in the dual-specificity GDHs of animals.

Sharkey, Michael A.↗

A Polarized High-Energy Photon Beam for Production of Exotic Mesons

This work describes design, prototyping and testing of various components of the Jefferson Lab Hall D photon beamline. These include coherent bremsstrahlung radiators to be used in this facility for generating the photon beam, a fine resolution hodoscope for the facility's tagging spectrometer, and a photon beam position sensor for stabilizing the beam on a collimator. The principal instrumentation project was the hodoscope: its design, implementation and beam testing will be thoroughly described. Studies of the coherent bremsstrahlung radiators involved X-ray characterization of diamond crystals to identify the appropriate line of manufactured radiators and the proper techniques for thinning them to the desired specification of the beamline. The photon beam position sensor project involved completion of a designed detector and its beam test. The results of these shorter studies will also be presented. The second part of this work discusses a Monte Carlo study of a possible photo-production and decay channel in the GlueX experiment that will be housed in the Hall D facility. Specifically, the γ p → Xp → b 1 π → ω π +1 π -1 channel was studied including its Amplitude Analysis. This exercise attempted to generate a possible physics signal, complete with internal angular momentum states, and be able to reconstruct the signal in the detector and find the proper set of JPC quantum numbers through an amplitude fit. Derivation of the proper set of amplitudes in the helicity basis is described, followed by a discussion of the implementation, generation of the data sets, reconstruction techniques, the amplitude fit and results of this study.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Position Monitor and Energy Analysis at the Fermilab Accelerator Science and Technology Facility

Fermilab Accelerator Science and Technology Facility has produced its first beam with an energy of 20 MeV. This energy is obtained by the acceleration at the Electron Gun and the Capture Cavity 2 (CC2). When fully completed, the accelerator will consist of a photoinjector, one International Liner Collider (ILC)-type cryomodule, multiple accelerator R&D beamlines, and a downstream beamline to inject 300 MeV electrons into the Integrable Optics Test Accelerator (IOTA). We calculated the total energy of the beam and the corresponding energy to the Electron Gun and CC2. Subsequently, a Beam Position Monitors (BPM) error analysis was done, to calculate the device actual resolution.

43 PARTICLE ACCELERATORS↗

Dark-field laser-scattering microscope for analyzing single macromolecules

To further isolate the scattered light 112 of a specific particle from the scattered light of a different particle, a pin hole device 116 can be used. The pin hole device 116 prevents unfocused light from other particles from entering the second plane 118, thus isolating a desired, focused image of one particle 110 of the sample 106. In one embodiment, the pin hole 116 has a size of several microns. At the second plane 118, a traditional imaging detection device 120 detects the defocused light. The position of the second image plane 118 is chosen for good angular resolution of the scattered light 112, and at the same time gives enough light for the imaging detection device 120 to obtain a sufficient reading.

Wu, Sheng↗

Kelvin probe force microscopy for high-resolution imaging of hydrogen in steel alloys [Poster]

Kelvin probe force microscopy (KPFM) was used to image and co-locate the presence of hydrogen in stainless steel (SS) with microstructure. Various SS samples were investigated, including forged, welded, LENS® fabricated, and pinch welded materials. KPFM images the local work function of a surface as a function of spatial position using atomic force microscopy. KPFM is capable of delivering high spatial (~10 nm) and potential (~5mV) resolution maps characterizing the microstrucure and the locally varying work function of surfaces. Hydrogen segregated at the surface of SS increases the local work function by either reducing tensile strain or by reducing the chemical potential of surface species. In a process known as hydrogen embrittlement, hydrogen segregates to and becomes trapped at extended defects (e.g. dislocations, boundaries, pores) which leads to the initiation of cracking and can result in structural failure. Hydrogen storage necessitates a proper understanding of the mechanisms of hydrogen embrittlement in SS. Developing advanced characterization techniques for hydrogen embrittlement is critical to identify long term solutions for materials exposed to hydrogen. Current techniques of observing hydrogen embrittlement involve mechanical testing, and optical microscopy with low resolution. Advance microstructural imaging techniques capable of resolving features down to the nanometer scale are needed. KPFM provides high resolution imaging for the characterization and development of SS components for hydrogen storage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate structure prediction of peptide–MHC complexes for identifying highly immunogenic antigens

Designing an optimal HIV-1 vaccine faces the challenge of identifying antigens that induce a broad immune capacity. One factor to control the breadth of T cell responses is the surface morphology of a peptide–MHC complex. Here, we present an in silico protocol for predicting peptide–MHC structure. A robust signature of a conformational transition was identified during all-atom molecular dynamics, which results in a model with high accuracy. A large test set was used in constructing our protocol and we went another step further using a blind test with a wild-type peptide and two highly immunogenic mutants, which predicted substantial conformational changes in both mutants. The center residues at position five of the analogs were configured to be accessible to solvent, forming a prominent surface, while the residue of the wild-type peptide was to point laterally toward the side of the binding cleft. We then experimentally determined the structures of the blind test set, using high resolution of X-ray crystallography, which verified predicted conformational changes. Our observation strongly supports a positive association of the surface morphology of a peptide–MHC complex to its immunogenicity. Our study offers the prospect of enhancing immunogenicity of vaccines by identifying MHC binding immunogens.

Park, Min-Sun↗

A Proof for the Unbiased Nature of Range-Doppler Measurements in Coarse-Resolution Dechirp-on-Receive Feedback Synthetic Aperture Radar Navigation

In feedback synthetic aperture radar (SAR) navigation, observables extracted from SAR range-Doppler images correct position and velocity errors accumulated within an associated navigation system. Unlike most other sensors, which produce measurements without input from a navigation system, SARs require a prior estimate of the radar’s position and velocity to adjust the radar’s matched filter during range-Doppler image formation. Consequently, it is possible for position and velocity errors within a navigation system to manifest as additional errors (biases) in the range-Doppler measurement observables. Prior work has not tackled this possibility in the context of feedback SAR navigation with a dechirp-on-receive radar. This paper offers a proof demonstrating that range-Doppler observables extracted from coarse-resolution vertical SAR images formed with a dechirp-on-receive radar may be safely modeled as unbiased measurements of the radar’s true position and velocity despite the presence of moderate navigation errors.

dechirp-on-receive↗

Continuous motion scan ptychography: Characterization for increased speed in coherent x-ray imaging

Ptychography is a coherent diffraction imaging (CDI) method for extended objects in which diffraction patterns are acquired sequentially from overlapping coherent illumination spots. The object’s complex transmission function can be reconstructed from those diffraction patterns at a spatial resolution limited only by the scattering strength of the object and the detector geometry. Most experiments to date have positioned the illumination spots on the sample using a move-settle-measure sequence in which the move and settle steps can take longer to complete than the measure step. We describe here the use of a continuous “fly-scan” mode for ptychographic data collection in which the sample is moved continuously, so that the experiment resembles one of integrating the diffraction patterns from multiple probe positions. This allows one to use multiple probe mode reconstruction methods to obtain an image of the object and also of the illumination function. We show in simulations, and in x-ray imaging experiments, some of the characteristics of fly-scan ptychography, including a factor of 25 reduction in the data acquisition time. This approach will become increasingly important as brighter x-ray sources are developed, such as diffraction limited storage rings.

43 PARTICLE ACCELERATORS↗

Extra-light gamma-ray imager for safeguards and homeland security

Gamma-ray imaging is the most important way to identify unknown gamma-ray emitting objects in decommissioning, security, overcoming accidents. Over the past two decades a system for producing of gamma images in these conditions became more or less portable devices. But in recent years these systems have become the hand-held devices. This is very important, especially in emergency situations, and measurements for safety reasons. We describe the first integrated hand-held instrument for emergency and security applications. The device is based on the coded aperture image formation, position sensitive gamma-ray (X-ray) detector Medipix2 (detectors produces by X-ray Imaging Europe) and tablet computer. The development was aimed at creating a very low weight system with high angular resolution. We present some sample gamma-ray images by camera. Main estimated parameters of the system are the following. The field of view video channel ∼ 490 deg. The field of view gamma channel ∼ 300 deg. The sensitivity of the system with a hexagonal mask for the source of Cs-137 (Eg = 662 keV), is in units of dose D ∼ 100 mR. This option is less then order of magnitude worse than for the heavy, non-hand-held systems (e.g., gamma-camera Cartogam, by Canberra.) The angular resolution of the gamma channel for the sources of Cs-137 (Eg = 662 keV) is about 1.20 deg. (authors)

42 ENGINEERING↗

Development of Position-Sensitive Magnetic Calorimeter X-ray Detectors

We are developing arrays of position-sensitive magnetic calorimeter (PoSM) X-ray detectors for future astronomy missions. The PoSM consists of multiple absorbers thermally coupled to one magnetic sensor. Each absorber element has a different thermal coupling to the sensor. This results in a distribution of different pulse shapes and enables position discrimination between the absorber elements. PoSMs are motivated by the desire to achieve the largest possible focal plane area with the fewest number of readout channels without compromising on spatial sampling. Optimizing the performance of PoSMs requires careful design of key parameters such as the thermal conductances between the absorbers, magnetic sensor and the heat sink, as well as the absorber heat capacities. We report on the first experimental results from four-absorber PoSMs, each absorber consisting of a two layer composite of bismuth and gold. The measured energy resolution (FWHM) was less than 5 eV for 6 keV X-rays into all four absorbers. Straightforward position discrimination by means of rise-time is also demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Separation and Classification of Lipids Using Differential Ion Mobility Spectrometry

Correlations between the dimensions of a 2-D separation create trend lines that normally depend on structural or functional characteristics of the compound class and thus facilitate classification of unknowns. This broadly applies to conventional ion mobility spectrometry (IMS)/mass spectrometry (MS), where the major biomolecular classes (e.g., lipids, peptides, nucleotides) occupy different trend line domains. However, strong correlation between the IMS and MS separations for ions of same charge has impeded finer distinctions. Differential IMS (or FAIMS) is generally much less correlated to MS and thus should better separate the trend lines and associated domains. We report the first observation of chemical class separation by trend lines using FAIMS, here for lipids. For all lipids, FAIMS is indeed more independent of MS than conventional IMS, and subclasses (such as phospho-, glycero-, or sphingolipids) form distinct, often non-overlapping domains. Even finer categories with different functional groups or degrees of unsaturation are often separated. As expected, resolution improves in He-rich gases: at ~70% He, glycerolipid isomers with different positions of fatty acid attachment can be resolved. These results open the door for lipidomics application of FAIMS, particularly shotgun lipidomics and targeted analyses of bioactive lipids.

99 GENERAL AND MISCELLANEOUS↗

The impact of atmospheric dispersion in the performance of high-resolution spectrographs

ABSTRACT Differential atmospheric dispersion is a wavelength-dependent effect introduced by the atmosphere. It is one of the instrumental errors that can affect the position of the target as perceived on the sky and its flux distribution. This effect will affect the results of astronomical observations if not corrected by an atmospheric dispersion corrector (ADC). In high-resolution spectrographs, in order to reach a radial velocity (RV) precision of 10 cm s−1, an ADC is expected to return residuals at only a few tens of milliarcseconds (mas). In fact, current state-of-the-art spectrograph conservatively require this level of residuals, although no work has been done to quantify the impact of atmospheric dispersion. In this work, we test the effect of atmospheric dispersion on astronomical observations in general, and in particular on RV precision degradation and flux losses. Our scientific objective was to quantify the amount of residuals needed to fulfil the requirements set on an ADC during the design phase. We found that up to a dispersion of 100 mas, the effect on the RV is negligible. However, on the flux losses, such a dispersion can create a loss of ∼2 per cent at 380 nm, a significant value when efficiency is critical. The requirements set on ADC residuals should take into consideration the atmospheric conditions where the ADC will function, and also all the aspects related with not only the RV precision requirements but also the guiding camera used, the tolerances on the flux loss, and the different melt data of the chosen glasses.

Wehbe, B.↗

Crystallization and preliminary characterization of a novel haem-binding protein of Streptomyces reticuli

The haem-binding protein HbpS from Streptomyces reticuli was crystallized and diffraction data were collected to a maximal resolution of 2.25 Å. Streptomyces reticuli is a soil-growing Gram-positive bacteria that has been shown to secrete a novel haem-binding protein known as HbpS. Sequence analysis reveals that homologues of HbpS are found in a wide variety of bacteria, including different Actinobacteria and the Gram-negative Vibrio cholera and Klebsiella pneumoniae. The in vivo production of HbpS is greatly increased when S. reticuli is cultured in the presence of the natural antibiotic haemin (Fe{sup 3+} oxidized form of haem). Mutational analysis demonstrated that HbpS significantly increases the resistance of S. reticuli to toxic concentrations of haemin. Previous data show that the presence of the newly identified two-component sensor system SenS–SenR also considerably enhances the resistance of S. reticuli to haemin and the redox-cycling compound plumbagin, suggesting a role in the sensing of redox changes. Specific interaction between HbpS and SenS–SenR, which regulates the expression of the catalase–peroxidase CpeB, as well as HbpS, has been demonstrated in vitro. HbpS has been recombinantly overexpressed, purified and crystallized in space group P2{sub 1}3, with a cell edge of 152.5 Å. Diffraction data were recorded to a maximal resolution of 2.25 Å and phases were obtained using the SAD method from crystals briefly soaked in high concentrations of sodium bromide.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffraction imaging of crystals with focused x-ray beams

We describe an imaging technique based on diffraction of a focused x-ray beam in crystals. A focused beam is formed by a zone plate and Bragg diffracted from a crystalline sample positioned between the zone plate and the focus. The intensity pattern is recorded by a high-resolution charge-coupled-device detector placed in the focus. Diffraction images recorded from perfect Si and GaAs crystals for various reflections demonstrate the broadening of the focused beam due to a finite scattering length. The images from semiconductor epitaxial films and heterostructures show additional peaks originating from the interfaces with their spatial position corresponding to the depth from the surface. Diffraction images from isolated defects in Si crystal demonstrate capabilities to study bulk defects. Theoretical simulations for perfect crystals show excellent agreement with experiments. We demonstrate that the new imaging technique is depth sensitive and combines structural sensitivity of traditional x-ray topography methods with spatial in-plane resolution provided by focusing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗